QUICK START
1) Plug a phone line into the jack marked LINE
2) Plug the A/C line cord into an outlet.
The MP-420 requires a 20 service feed and NEMA 5-20R outlet.
3) Connect any A/C powered devices into the outlets on the MP-415, MP-420.
The maximum current rating for all of the devices connected to the
MP-415 cannot add up to more than 12 Amps.
The maximum current rating for all of the devices connected to the
MP-420 cannot add up to more than 16 Amps.
4) Call the phone number connected to the unit. The switch will answer with “PAL READY”
5) Enter ‘1’ The MP-4xx will respond with ‘ 1 On’
6) Enter ‘#’ Outlet 1 will turn off and the MP-4xx will respond with ‘1 Off ’
7) Repeat steps 5 and 6, entering 1 -4 for the desired outlet.
8) Hang up when finished
9) Read the rest of the manual. There are many more features and options.
GENERAL DESCRIPTION
The MultiPAL Remote Controlled
Power Strip, models MP-415 and
MP-420 allow an operator with a
tone dial telephone to access,
interrogate and control four A/C
power outlets. (Except were noted
both models will be refered to as
the MP-415 in this manual) Each of
the four outlets on the MP-415 can
be independently turned on, off or
pulsed for power-on reset. The
unique MultiPAL controller allows
the switch to be placed in series with any normal telephony device (phone, fax, modem, etc.). Normal
calls can pass transparently through MP-415; only when you enter a DTMF (touch tone) code, will the MP-
415 respond and allow switch control.
To operate the MP-415, place a telephone call to the dial line connected to the unit. The MP-415 provides
three call answer modes and several security options. When the call is validated, MP-415 will read off the
current status of the switch and then prompt the caller to change the switch position. When a change is
made, the new status is repeated and additional changes can be made. When no more changes are
required, the caller can hang-up, or send an additional code to access any extension device connected to
the MP-415.
Tone Controlled Power Strip
With MultiPAL Voice Response
Model MP-415, MP-420
Dial Line
Call Pass-thru
"Switch 1
is ON"
4 Power Controlled
Devices
Expansion to 4
Additional Outlets
REF: PWR\MP-415_V030613D.DOC

Models MP-415, MP-420 Page 2
IMPORTANT SAFETY INSTRUCTIONS
When using this product, basic safety precautions should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including the following:
1. Read and understand all instructions.
2. Follow all warnings and marked on the product.
3. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol
cleaners. Use a damp cloth for cleaning.
4. Do not use this product in an outdoor environment or near water, for example, near a bath tub, wash
bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.
5. Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious
damage to the product.
6. Slots and openings in this product and the back or bottom are provided for ventilation to protect it
from overheating, these openings must not be blocked or covered. The openings should never be
blocked by placing the product on the bed, sofa, rug, or other similar surface. This product should
never be placed near or over a radiator or heat register. This product should not be placed in a built-in
installation unless proper ventilation is provided.
7. This product should be operated only from the type of power source indicated on the marking label. If
you are not sure of the type of power supply to your home, consult your dealer or local power
company.
8. This product is equipped with a three wire grounding type plug, a plug having a third (grounding) pin.
This plug will only fit into a grounding type power outlet. This is a safety feature. If you are unable to
insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the
safety purpose of the grounding type plug. Do not use a 3-to-2 prong adapter at the receptacle; use of
this type adapter may result in risk of electrical shock and/or damage to this product.
9. Do not allow anything to rest on the power cord. Do not locate this product where the cord will be
abused by persons walking on it.
10. Do not overload wall outlets and extension cords as this can result in the risk of fire or electric
shock.
11. Never push objects of any kind into this product through slots as they may touch dangerous voltage
points or short out parts that could result in a risk of fire or electrical shock. Never spill liquid of any
kind on the product.
12. To reduce the risk of electrical shock, do not disassemble this product, but take it to a qualified
serviceman when some service or repair work is required. Opening or removing covers may expose
you to dangerous voltages or other risks. Incorrect re-assembly can cause electric shock when the
appliance is subsequently used.
13. Unplug this product from the wall outlet and refer servicing to qualified service personnel under the
following conditions:
a) When the power supply cord or plug is damaged or frayed.
b) If liquid has been spilled into the product.
c) If the product has been exposed to rain or water.
d) If the product does not operate normally by following the operating instructions. Adjust only
those controls, that are covered by the operating instructions because improper adjustment of
other controls may result in damage and will often require extensive work by a qualified
technician to restore the product to normal operation.
e) If the product has been dropped or has been damaged.
f) If the product exhibits a distinct change in performance.
14. Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a
remote risk of electric shock from lightning.
15. Do not use the telephone to report a gas leak in the vicinity of the leak.
16. Do not exceed the maximum output rating of the auxiliary power receptacle.
SAVE THESE INSTRUCTIONS

Models MP-415, MP-420 Page 3
PROGRAMMING
Understanding MP-415’s Many Operational Features
All user programmable settings are made prior to placing MP-415 in service using a standard tone dial
telephone connected to MP-415’s extension port (EXT). These settings are stored in non-volatile memory
and will not be lost when power is removed. To enter the programming mode; disconnect the telephone
line, and connect a standard tone dial telephone to the extension jack (EXT). Lift the receiver and MP-415
will prompt “PAL Ready”. Now press the # key twice and MP-415 will respond with “ Program”. MP-415
is now ready and eager to be programmed. When a correct program entry is made, MP-415 responds
“OK” , if an error is made on entry, MP-415 responds “Error”
Many of Multi-Pal’s features have been pre-programmed at the factory. These can be changed by
following the instruction below and referring to the programming summary on page 4.
MP-415’s Security Modes
MP-415 canbe setto respond to calls with or without the caller entering a preset security code to gain
access to the control functions or ringing to the extension. MP-415 can be set to require a security code
for control functions only (type 1) or (type 2) security for both control and access to ring to the
extension. Type 0 is no security code required. These features are explained for each of the Call Answer
Modes listed below. In the Answer and Prompt mode, if a code is required and the wrong code is sent,
MP-415 will respond “Error”.
Call Answer Modes
MP-415 has three ways to answer incoming calls. The mode selected will depend on what you want the
caller to hear and how secure you want the system to be. In all cases, the number of rings before MP-415
answers the call, security codes required for MP-415 to accept operating commands, and how the call is
passed on to the Extension Port, can all be selected prior to use.
Normal Answer Mode, Ring Back
In this mode, MP-415 will answer the call and generate a normal ringback signal. This signal sounds like
the one you hear when the phone company is ringing any phone. A standard ringback cycle consists of 2
sec. of ring tone followed by 4 sec. of quiet. During the quiet times, between each 2 sec. ring, MP-415
listens for tone digits (DTMF) sent by the caller. If, after two ringback cycles, (12 sec.) no valid tones are
heard, MP-415 will ring the Extension Port.
Use the Normal Answer Mode if: Voice or Fax calls are being made to the device on MP-415’s
Extension Port and you don’t want the caller to know that MP-415 is there.
If no security code is required, entering any tone digit during the two quiet times will wake MP-415 up. Wait
for MP-415 to respond “PAL Ready “ before entering operating commands,see page 5. If MP-415 is set
for security on control only, type 1, the code may be entered during any of the quiet times to gain access
to MP-415’s control functions. If the correct code is entered, wait for MP-415 to respond “PAL Ready “
before entering operating codes. If the wrong code or no code is entered, MP-415 will ring to the
extension. If MP-415 is set for control and ringing to the extension security, type 2, if the wrong code, or
no code is entered, the call will be terminated, dropped by MP-415.
After placing MP-415 in the programming mode, (##) enter 6 plus 0 followed by the ‘∗’ key to set MP-415
in the Ring Back mode.
Answer and Prompt Mode (factory default)
MP-415 answers the call and issues a voice prompt “PAL Ready” if no security code is required, or if
security is required, a voice prompt “Enter Code” is sent. The caller may now enter the security code or

Models MP-415, MP-420 Page 4
any control digit if no security code is required. If no control tones are received in 6 seconds, MP-415 will
ring the Extension when no security code is required.
Use the Answer and Prompt Mode if: you want to know exactly when to enter security
and control codes.
If MP-415 is set for security on control only, type 1, the code may be entered when prompted to gain
access to MP-415’s control functions. If the correct code is entered, MP-415 will respond “PAL Ready“. If
the wrong code is entered, MP-415 responds “Error” and the sender may try once more before the
extension is rung. If MP-415 is set for control and ringing to the extension security type 2, if the wrong
code is entered twice, or no code is entered, the call will be terminated, dropped by MP-415. In the
program mode to set MP-415 for the Answer and Prompt mode, enter 6 plus 1 followed by ‘∗’key.
Answer And Quiet Mode
MP-415 will answer the call and be quiet for six seconds, waiting for control codes. If none are received
within 6 seconds, MP-415 will ring the Extension.
Use the Answer and Quiet Mode if: You want more secure control of power and the
shortest time before the extension is rung.
If MP-415 is set for security on control only, type 1, the code may be entered during the 6 sec quiet
time to gain access to MP-415’s control functions. If the correct code is entered, MP-415 will respond
“PAL Ready “. If the wrong code is entered, MP-415 does not respond, and the extension will be rung.
If MP-415 is set for control and ringing to the extension security, type 2, if the wrong code is entered,
or no code is entered, the call will be terminated, dropped by MP-415. With the right code, MP-415
answers “PAL Ready”. To program MP-415 for the Answer and Quiet mode, enter 6 plus 2 followed
the ‘∗’key.
Number of Rings before MP-415 Answers the Call (Default = 2)
MP-415 can be set to answer calls after it detects a set number of rings from 1-6. To program the number
of rings, enter 2 followed by the desired number, followed by the ‘∗’. Example . To have MP-415 answer
in 4 rings, in the program mode, enter 2 4 ‘∗’. MP-415 responds “OK” if the entry was accepted, “Error”
if not.
Number of Rings to the Extension (Default = 4)
MP-415 can be set to ring the extension a number of times before the call is terminated. Enter 7 plus the
desired number, 1-6 followed by the ‘∗’. Example : 74 ‘∗’. Will ring extension four times.
Security Mode (Default = no security)
The security modes are set by entering 5 plus 0, 1, or 2 ‘∗’. 0 = no security, 1 for control only,
and 2 for security for all functions, control and extension ring.
Example: to set for security on control only. Enter 51‘∗’.
Setting a Security Code (Default = none set)
To program a security code, enter the ‘#’ key followed by up to six number characters, followed by the
‘∗’ key. Example; to set a security code of 3451, enter #3451 ‘∗’. MP-415 responds OK if entry is
accepted or Error if not.

Models MP-415, MP-420 Page 5
Reset Time (Default = 10 seconds)
The MP-415 can provide power-on reset with a pre-set power off time. This time can be set to turn the
power off 5 to 45 sec. in 5 sec. increments. Example: to set for 15 sec. enter 9 plus 3 ‘∗’.
(3x5=15sec.)
Number of Active Ports (Default = 8)
The MP-415 has four controllable outlets. An additional four can be controlled using the K-415A-R1
expansion unit. When all eight outlets are not being used, change this setting can to limit the voice status
response to those that are active. To set the number of active ports, enter ‘1’ plus the number of active
ports (1-8 ) ‘∗’.. Example: to set the first 3 ports 1-3 as active, enter 13‘∗’.
MULTIPAL PROGRAMMING SUMMARY
Feature Enter Options & MP-415’s Response
Prompts
Lift receiver on Extension
with no phone line
connected
“ PAL Ready “
To Enter Programming Mode ## “Program”
Answer Mode 6 n «0= Normal Answer, Ringback
1= Answer & Prompt (Default)
2= Answer & Quiet
MP-415 Answers Call on # of
Rings 2 n «n = Number of Rings, 1-6 (Default
= 2)
MP-415 Rings to the
Extension 7 n «n = Number of Rings, 1-6 (Default =
4)
Security Type Select 5 n «0= Security Off (Default)
1= Security for Control functions
Only.
2= Full Security, control &
extension ring.
Security Code # n… «n… = up to six digits. Example: for
Security Code 123 enter #123*
Reset Time ( Power, Switch
Reset) 9 n «n = 1 - 9 five second increments
Default Example 92* sets pulse to
10 Sec.
Active Ports 1 n «n= number of active or in use ports.
Example: three active, enter
13*
n =The Number to Enter. «= end of this program instruction
When each full programming command is entered correctly and accepted by MP-415, MP-415 will
respond “OK“ if accepted or “ERROR“ if not accepted. If an error is made, the program step may be
repeated.
Example: To program the number of rings (from 1 to 6) before MP-415 answers a call. In the
programming mode, enter the digit 2 followed by the desired number of rings, followed by the «to end this
program instruction. ( 2 + 3 + «) will program MP-415 to answer in three rings. MP-415 will respond
“OK“.

Models MP-415, MP-420 Page 6
MULTIPAL OPERATING COMMANDS
After MP-415 has answered a call, and depending on the answer and security mode previously selected,
the following commands may be entered to operate MP-415.
1-8 Report Status of an Outlet
MP-415 will report ‘ON’ or ‘OFF’ as indicated by the current outlet status. MP-415 will also report
‘ERROR’ if the controller cannot set the switch into the desired position. Once an outlet is
selected, it can then be changed by entering a # or «to toggle or pulse.
# Change Status of an Outlet
MP-415 will toggle the currently selected (or all if 9 is used) outlet and report the new status.
«Reset an Outlet
The MP-415 will pulse the outlet for the number of seconds determined by the Reset Time setting
9 Report Status of All Outlets
MP-415 will read off the status of all outlets. The number of outlets reported is controlled by the
Active Ports setting.
91 Turn All Outlets On
MP-415 will turn all active outlets On, then read off the status of all outlets.
92 Turn All Outlets Off
MP-415 will turn all active outlets Off, then read off the status of all outlets.
0 Ring Extension
MP-415 will ring the EXT port. No additional switch commands will be accepted by MP-415
Example: You Send MP-415 Does This MP-415 Says This
1“ 1 ON ”
# Turn off Outlet 1 “ 1 OFF ”
3“ 3 ON ”
«Turn Off Outlet 3 “ 3 OFF Reset ”
Wait (Reset Time)
Turn On Outlet 3 “ 3 ON Reset ”
91 Turn On All Outlets “ 1 On, 2 On……”

Models MP-415, MP-420 Page 7
Indicators
The K-415 provides 5 indicator lamps.
POWER : Indicates that A/C power is applied to the K-415
1-4 Indicates which of the four outlets is ON
Positive Feedback
MP-415 monitors the status of the outlets and reports its actual status. If the status detected does not
match the command given over the phone, MP-415 will report an ‘ERROR’. An error will also be reported
when obtaining status of outlets 5-8 if no expansion unit is installed. To correct this, change the setting for
the number of active ports to 4.
CONNECTIONS TO MP-415
Input: MP-415 Standard NEMA 5-15 Plug on 6 foot 14/3 line cord -120VAC
MP-420 NEMA 5-20P Plug on 12/3 line cord -120 VAC. Requires 20 AMP service.
Outputs: 1-4Standard NEMA 5-15 Receptacle.
MP-415 Combined maximum load must not exceed 12 Amps.
MP-420 Combined maximum load must not exceed 16 Amps.
Line: Connect the Telephone Line
EXT: Connect any telephone device (optional)
Control Expansion for K-415 for Switched Outlets 5-8
This connection provides expansion of circuits 5-8 to Dataprobe’s K-415 four outlet power
strip. Use cable # PAL-K415, supplied with the K-415. For connection to other devices,
consult Dataprobe.
1 2 3 4
15A 1 2 3 4 EXT Line Control
MP-415
K-415
Expansion Unit
PAL-K415
Expansion Cable

Models MP-415, MP-420 Page 8
TECHNICAL SUPPORT, RETURNS & WARRANTY
Dataprobe Technical Support is available 8:30AM to 5:30PM ET to assist you in the installation and
operation of this product. To obtain Technical Support call our Tech Support Hotline at 201-967-8788, or
•Model of Product
•Serial Number
•Date of Purchase
•Name of Seller (if other than Dataprobe)
If you purchased this product through an Authorized Dataprobe Reseller, you should contact them first,
as they may have information about the application that can more quickly answer your questions.
WARRANTY
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original
defects in material and workmanship for a period of One Year from the date of initial purchase. If the
product should prove defective within that period, Seller will repair or replace the product, at its sole
discretion.
Service under this Warranty is obtained by shipping the product (with all charges prepaid) to the address
below. Seller will pay return shipping charges. Call Dataprobe Technical Service at (201) 967-8788 to
receive a Return Materials Authorization (RMA) Number prior to sending any equipment back for repair.
Include all cables, power supplies and proof of purchase with shipment.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT,
MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY
EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY LAW, ALL IMPLIED
WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANT ABILITY OR FITNESS FOR ANY PURPOSE ARE
LIMITED TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES
ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES.
Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow
the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions
may not apply to you. This warranty gives you specific legal rights, and you may have other rights which
vary from jurisdictions to jurisdiction.
WARNING: The individual user should take care to determine prior to use whether this device is suitable,
adequate or safe for the use intended. Since individual applications are subject to great variation, the
manufacturer makes no representation or warranty as to the suitability of fitness for any specific
application.
This manual suits for next models
1
Table of contents
Other Dataprobe Network Hardware manuals