DAVI & CIA CS1300C User manual

CS1300C
USER’S MANUAL
MA23-02/B
12/09/2011
www.davicia.com

USER’S MANUAL
MA23-02/B
2
INDEX
Page
1.
1.1.
1. DESCRIPTIO
DESCRIPTIODESCRIPTIO
DESCRIPTIO
3
2.
2.2.
2. I STALLATIO
I STALLATIOI STALLATIO
I STALLATIO
2.1. Scale assembly
2.2. Location and setting
2.3. Startup
4
4
5
5
3.
3.3.
3. OPERATIO
OPERATIOOPERATIO
OPERATIO
3.1. LCD symbol description
3.2. Key functions
3.3. Weighing
3.4. Taring
3.5. Hold
3.6. Body Mass Index (BMI)
3.7. Pre-Tare
6
6
7
7
7
8
8
9
4.
4.4.
4. SETUP
SETUPSETUP
SETUP
4.1. Connecting with PC
4.2. Print function
11
11
12
5.
5.5.
5. MAI TE A CE
MAI TE A CEMAI TE A CE
MAI TE A CE
A D CLEA I G
A D CLEA I GA D CLEA I G
A D CLEA I G
5.1. Instructions for charge and connect
5.2. Instructions for replacing batteries
5.3. Environmental
5.4. Equipment disposal
13
13
13
13
13
6.
6.6.
6. TROUBLESHOOTI G
TROUBLESHOOTI GTROUBLESHOOTI G
TROUBLESHOOTI G
14
7.
7.7.
7. HEIGHT
HEIGHTHEIGHT
HEIGHT ROD ACCESSORIES
ROD ACCESSORIES ROD ACCESSORIES
ROD ACCESSORIES
7.1. Height rod assembly
7.2. Battery installation
7.3. Key functions
7.4. Calibrating the height rod
7.5. Using the height rod
7.6. Technical Specifications
15
15
16
17
17
18
19
8.
8.8.
8. TECH ICAL SPECIFICATIO S
TECH ICAL SPECIFICATIO STECH ICAL SPECIFICATIO S
TECH ICAL SPECIFICATIO S
20
9.
9.9.
9. WARRA TY CERTIFICATE
WARRA TY CERTIFICATEWARRA TY CERTIFICATE
WARRA TY CERTIFICATE
21
10.
10.10.
10. CE DECLARATIO OF CO FORMITY
CE DECLARATIO OF CO FORMITYCE DECLARATIO OF CO FORMITY
CE DECLARATIO OF CO FORMITY
22

USER’S MANUAL
MA23-02/B
3
1. DESCRIPTION
(1) Display unit
(2) Mounting holes for height rod accessories
(3) Scale platform
(4) Adjustable feet
(5) Level
1
2
4
5
3

USER’S MANUAL
MA23-02/B
4
2. INSTALLATION
Before putting the device into use, please read with care the information given in the Operating Instructions.
They contain important instructions for installation, proper use and maintenance of the device.
The manufacturer shall not be liable for damages arising out of failure to heed the following instructions:
o When using electrical components under increased safety requirements, always comply with the appropriate
regulations.
o Improper installation will render the warranty null and void.
o Ensure the voltage marked on the power supply unit, matches your main power supply.
o This device is designed for use indoors.
o Observe the permissible ambient temperatures for use.
o The device meets the requirements for electromagnetic compatibility. Do not exceed the maximum values
specified in the applicable standards.
2.1
2.12.1
2.1.
. .
. SCALE ASSEMBLY
SCALE ASSEMBLYSCALE ASSEMBLY
SCALE ASSEMBLY
1. Fixing first handrail column on platform
2. Fixing second handrail column on platform
3. Fixing third handrail column on platform
4. Fixing third handrail column on platform

USER’S MANUAL
MA23-02/B
5
5. Fixing handrail
6. Assemble handrail and column
7. Fixing handrail and column with screw 8. Attention: The screws to mount handrail must be
tightly fixed
2.2
2.22.2
2.2. LOCATIO A D SETTI G
. LOCATIO A D SETTI G. LOCATIO A D SETTI G
. LOCATIO A D SETTI G
We strongly recommend you use this device on flat and hard surface. Any soft surface, like carpet will cause
inaccuracy.
2.3
2.32.3
2.3. STARTUP
. STARTUP. STARTUP
. STARTUP
o Connect the equipment to the power supply using the AC adaptor.
o Press the O /OFF button in the indicator.
o Wait until “0” appears on display.

USER’S MANUAL
MA23-02/B
6
3. OPERATION
Before reading detailed instructions on how to use all the weighing functions that are built into your scale, please
read the following important guidelines:
o Always be sure that the display shows `Zero` before use, if it does not then please press the ZERO key.
o The equipment is designed to detect when a stable weight is achieved, your reading should be taken at this
point.
3.1
3.13.1
3.1.
. .
. LCD SYMBOL
LCD SYMBOLLCD SYMBOL
LCD SYMBOL DESCRIPTIO
DESCRIPTIO DESCRIPTIO
DESCRIPTIO
Display
DisplayDisplay
Display
Description
DescriptionDescription
Description
[→ 0 ←] Zero symbol: If the scale does not show exactly zero value although the scale pan is
unloaded, press the [
[[
[→0
00
0←]
] ]
] key. After a short waiting time, the scale will be zeroed again.
Stable symbol: If the display shows the stabilization display [ο], the scale is in the stable
condition. When the scale is in the unstable condition, the stabilization display [ο]
disappears.
- Minor weight: Weight under zero.
LOW Low Battery: Battery need to change or replace.
BMI
Calculated value of the body mass index (BMI).
HOLD
Hold function / saving function is active.
PRE-TARE
Initially set tare value is active.
NET
The net weight is displayed.
WEIGHT
The present weight value is displayed.
P
RE
-
TARE Indication
kg
ET WEIGHT Indication
3
WEIGHT Indication
HOLD Indication
Stable symbol
Minor weight
Zero symbol
Low Battery

USER’S MANUAL
MA23-02/B
7
3.2
3.23.2
3.2.
. .
. KEY FU CTIO S
KEY FU CTIO SKEY FU CTIO S
KEY FU CTIO S
Designation
Designation Designation
Designation
Function
Function Function
Function
O /OFF-switch Turn O /OFF the scale
PRI T button Data transmission via interface(Print-out the results)
BMI button Determine Body Mass Index
HOLD button To hold weighing result on the display / determine stable weighing value
ZERO setting key To reset the display to 0.0kg display / Zero the scale (±2% of full capacity)
M1-5 button To store 5 pre-tare values
PRE-TARE button Setup target weight for tare before weighing
TARE button Tare weight during weighing process
CLEAR button To clear the wrong entry while entering digits
E TER-key To confirm the performing functions
umeric keys umerical value Entering digits
3.3
3.33.3
3.3.
. .
. WEIGHI G
WEIGHI GWEIGHI G
WEIGHI G
Switch on the scale with the [O /OFF]
[O /OFF] [O /OFF]
[O /OFF] key. The diagnostic scale self-check is performed and then the software
version is displayed. The scale is ready for weighing when the “0,00 kg
0,00 kg0,00 kg
0,00 kg” weight display is shown.
OTE: If “0,00 kg” won’t display on the screen, press [
[[
[
→
0
00
0
←
]
]]
] key to zero the scale, [
[[
[
→
0
00
0
←
]
] ]
] can be used any time
to zero the scale.
Place a person in the middle of the scale. Wait until the stability display (ο) is shown and then read the weighing
result.
DIRECTIO : If a person is heavier than the weighing range, the display will show the “Err” symbol (= overload).
3.4
3.43.4
3.4.
. .
. TARI G
TARI GTARI G
TARI G
Tare allows the user to zero the instrument to cancel the weight of a container/ clothes from the reading of the
instrument, thus giving the true weight of the product/ person being tested.
o Turn on the scale using [O /OFF]
[O /OFF][O /OFF]
[O /OFF] key.

USER’S MANUAL
MA23-02/B
8
o When“0,00 kg
0,00 kg0,00 kg
0,00 kg” displays on the screen and scale beeps twice, place the object (clothes) to be tared on the tray.
o Press [TARE]
[TARE][TARE]
[TARE] key after the weight stabilizes and stable sign appears on the display.
o Display will return to “0,00 kg
0,00 kg0,00 kg
0,00 kg”
o Place the item/ baby to be weighed (without removing the tare object). The weighing result is the et weight
of the item / baby.
o To delete the saved tare value, remove the tare object from the tread platform and press [TARE]
[TARE][TARE]
[TARE] key.
3.5
3.53.5
3.5.
. .
. HOLD
HOLDHOLD
HOLD
The scale is provided with the integrated hold function (determination of average value). It enables people to be
weighed accurately although they are not still on the scale plate.
OTE: Determination of average value is not possible when a person moves too much.
o Switch on the scale with the [O /OFF]
[O /OFF][O /OFF]
[O /OFF] key. The scale self-check diagnostic is performed. The scale is ready
for weighing when the “0,00 kg
0,00 kg0,00 kg
0,00 kg” weight display is shown.
o Place a person in the centre of the scale plate.
o Press the [HOLD]
[HOLD][HOLD]
[HOLD] key. When the triangle is flashing on the display, the scale takes some measuring values and
then the calculated average value is displayed.
o Remove the object/ baby from the scale platform. The object/ baby’s weight reading will remain on the
display.
o Press the [HOLD]
[HOLD][HOLD]
[HOLD] key again to return the scale to the normal weighing mode.
o HOLD function can be activated before or after putting the weight on the platform. In case of weighing babies
that move a lot, it is recommended to press [HOLD]
[HOLD][HOLD]
[HOLD] key before the person moves on the platform.
3.6
3.63.6
3.6.
. .
. BODY MASS I DEX (BMI)
BODY MASS I DEX (BMI)BODY MASS I DEX (BMI)
BODY MASS I DEX (BMI)
For BMI calculation, height is needed, therefore it is recommended to measure the height of subject before
starting weighing procedure.
o Turn O the scale using [O /OFF]
[O /OFF][O /OFF]
[O /OFF] key.
o Proceed to weigh as normal.
o After the weight is stable and stable sign displays on the screen press [BMI]
[BMI][BMI]
[BMI] key.
o Display will change to “0,00 kg
0,00 kg0,00 kg
0,00 kg”.
o Key-in the height of the person using numeric keys (0~9). Example: 186cm (the height should be in
centimeters).
o Press [E TER]
[E TER][E TER]
[E TER] to confirm, the Display will show the B.M.I. of the person.
o Press [BMI]
[BMI][BMI]
[BMI] again to return to normal mode.
Categories of BMI
Classification of weight for adults over 18 years on the basis of Body Mass Index according to WHO, 2000 EK IV
and WHO 2004 (WHO - World Health Organization).

USER’S MANUAL
MA23-02/B
9
3.7
3.73.7
3.7.
. .
. PRE
PREPRE
PRE-
--
-TARE
TARETARE
TARE
The scale can store 5 sets of pre-tare values, and there are two methods to store pre-tare value – Using Dead
Weight or Enter weight using 0~9 keys:
Using Dead Weight
Description
DescriptionDescription
Description
Example
ExampleExample
Example
Press M1-5 key after loading the weight; the display will show blinking m sign.
Press numeral key 1 ~ 5 to assign the position to pre-tare weight. For example:
Press 1 to assign position-1 to preset tare weight.
The display will blink and makea beep sound.
OTE: You can assign any other position (from 1~5) to pre-tare weight.
Enter Weight Using 0-9 Keys
Description
DescriptionDescription
Description
Example
ExampleExample
Example
Press PRE-TARE key, and the extreme left digit will blink.
Enter PRE-TARE weight using 0~9 keys. For example: 10kg
Press E TER key to confirm the pre-tare weight; the display will show the minus
sign on left of the pre-tare weight value.
Press M1-5 key; the blinking m sign will appear on the display.
Press numeral key 1 ~ 5 to assign the position to pre-tare weight.

USER’S MANUAL
MA23-02/B
10
The instrument will make flash and beep sound and will display the saved Pre-
Tare Weight.
Recall Pre-Tare Value:
Description
DescriptionDescription
Description
Ex
ExEx
Example
ampleample
ample
Long press PRE-TARE key for 3 seconds; the display will show the blinking m sign.
Press numeral key 1 ~ 5 to choose pre
Press numeral key 1 ~ 5 to choose prePress numeral key 1 ~ 5 to choose pre
Press numeral key 1 ~ 5 to choose pre-
--
-tare value
tare valuetare value
tare value
Press E TER key to confirm the pre-tare weight; the instrument will
automatically perform tare function.
Press PRE-TARE key to return to ormal Mode.

USER’S MANUAL
MA23-02/B
11
4. SETUP
Switch O the scale and long press [ZERO]
[ZERO][ZERO]
[ZERO] key for 3 seconds. First “SETUP” and then “A.OFF” will display
successively.
Auto-off time setup
This enables operator to select the auto turn OFF time of the device.
Auto off time:
Auto off time:Auto off time:
Auto off time: 120 sec/180 sec/240 sec/300 sec/Off
Buzzer on/off setup
This enables operator to select beep sound O /OFF.
Buzzer:
Buzzer:Buzzer:
Buzzer: On/Off
OTE: To confirm the settings, please press HOLD when “E D” displays on the display.
4.1
4.14.1
4.1.
. .
. CO ECTI
CO ECTICO ECTI
CO ECTI G WITH PC
G WITH PCG WITH PC
G WITH PC
The equipment can be connected to PC to transfer the weighing results.
1. Start Hyper Terminal
Start Hyper Terminal program from clicking: Start Menu → Programs → Accessories → Communication →
Hyper Terminal.
2. ew Connection Description
Give new connection a name then click OK.
3. Select Your COM Port
Click Connect to select your COM port. Usually there’s only one option for select. Then click OK.
4. Port Settings
Click Bits per second to set up rate at 9600, Data bits at 8, Parity at one, Stop bits at 1 and Flow control at
Hardware. Then click OK to complete your setting.
5. Output Data
When the patient has been weighed and BMI calculated, simply press the PRI T key to output data from scale
to PC or an Optional Printer.
Parameters of RS232 interface
Set parameters of the scale interface on the connected device. It is not possible to change the scale parameters.
o Baud rate: 9600 bps

USER’S MANUAL
MA23-02/B
12
o Parity check: one
o Data length: 8 bits
o Stop bit: 1 bit
o Handshake: RTS/CTS
o Data code: ASCII.
4.2
4.24.2
4.2.
. .
. PRI T FU CTIO
PRI T FU CTIOPRI T FU CTIO
PRI T FU CTIO
The Weighing, BMI and Height results can be printed-out for records using RS232 interface cable (included in
accessory kit), which is connected with the round plug at the back terminal.
After weighing and calculating BMI simply press PRI T
PRI TPRI T
PRI T key to print out the results.
The format presented below is the standard format of results print-out and cannot be changed.

USER’S MANUAL
MA23-02/B
13
5. MAINTENANCE AND CLEANING
The scale does not require any routine maintenance. However, we recommend checking the scale’s accuracy at
regular intervals. The regularity of these checks is dependent on the level of use and the state of the scale.
o We would recommend using alcohol based wipes or similar when cleaning the scale.
o Please do not use large amounts of water when cleaning the scale as this will cause damage to the scale’s
electronics, you should also refrain from using corrosive liquids or high pressure washers.
o Always disconnect the scale from the main power supply before cleaning.
5.1
5.15.1
5.1.
. .
. I STRUCTIO S FOR CHARGE A D CO ECT
I STRUCTIO S FOR CHARGE A D CO ECTI STRUCTIO S FOR CHARGE A D CO ECT
I STRUCTIO S FOR CHARGE A D CO ECT
If “Lo” is displayed on the LCD, you should charge scale with AC adaptor.
Locate adaptor plug at the rear of indicator.
Locate adaptor plug at the rear of indicator.Locate adaptor plug at the rear of indicator.
Locate adaptor plug at the rear of indicator.
CAUTIO :
Always connect the AC adaptor to the indicator before connecting to the main power supply. Please
disconnect the adaptor from main power supply before indicator.
5.2
5.25.2
5.2.
. .
. I STRUCTIO S FOR REPLACI G BATTERIES
I STRUCTIO S FOR REPLACI G BATTERIESI STRUCTIO S FOR REPLACI G BATTERIES
I STRUCTIO S FOR REPLACI G BATTERIES
o Remove the battery cover
o Take the battery housing out
o Replace new batteries
o Make sure batteries are well installed
o Reinstall the battery housing
1. Reinstall the battery cover
5.3
5.35.3
5.3.
. .
. E VIRO ME TAL
E VIRO ME TALE VIRO ME TAL
E VIRO ME TAL
All batteries contain toxic compounds; disposal of batteries should be delegated to a competent organization,
complying with the deposit of Poisonous Waste Regulation 1972.
Please do not incinerate batteries.
The optimum operating temperature for the scale is 5ºC to +35ºC; although it will operate at higher and lower
temperatures the scale’s battery life will adversely be affected.
5.
5.5.
5.4
44
4. EQUIPME T DISPOSAL
. EQUIPME T DISPOSAL. EQUIPME T DISPOSAL
. EQUIPME T DISPOSAL
All electrical and electronic products should be disposed of separately from the
municipal waste stream via designated collection facilities appointed by the
government or the local authorities.
This crossed-out wheeled bin symbol on the product means the product is covered
by the European Directive 2002/96/EC.
The correct disposal and separate collection of the equipment will help prevent
potential negative consequences for the environment and human health. It is a
precondition for reuse and recycling of used electrical and electronic equipment.

USER’S MANUAL
MA23-02/B
14
6. TROUBLESHOOTING
Error Message
Error MessageError Message
Error Message
Reason
ReasonReason
Reason
Action
ActionAction
Action
Low Battery: This warning shows
that the voltage of battery is too
low to use
Please replace a new battery or plug the AC
adaptor for operation
Overload: The total load exceeds
the maximum capacity of the scale
Please reduce the loading and try again
Counting error (too high): Indicates
that the signal from the load cell is
too high
This error is normally caused by a serious fault on
the scales such as faulty load cell or wiring. Please
contact the local service representative.
Counting error (too low): Indicates
that the signal from the load cell is
too low
This error is normally caused by a serious fault on
the scales such as faulty load cell or wiring. Please
contact the local service representative.
Zero count over calibration zero
range +10% while power on
Please recalibrate the instrument
Zero count under calibration zero
range -10% while power on
Please recalibrate the instrument
EEPROM Error: Indicates that
there is a fault with the scale’s
software
This error is normally caused by a serious fault on
the scales such as faulty load cell or wiring. Please
contact the local service representative.

USER’S MANUAL
MA23-02/B
15
7. HEIGHT ROD ACCESSORIES
AC1200D
AC1200D is a digital height rod to be mounted on the scale with measuring range from
(120~200cm). AC1200D have LCD display for convenient, accurate and quick height
measurement. It can be connected with the scale indicator to transfer the height
measurements directly, therefore while calculating BMI the users don’t need to enter the
height. Simply step on the weighing platform and as the weight stabilizes adjust the head
piece to measure the height, the scale will display the height and BMI results.
AC1200M
AC1200M is a mechanical height rod to be mounted on the scale with measuring range of
(120~200cm), AC1200M don’t have LCD display, instead it automatically transfers the
height measurement to weighing scale, therefore while calculating BMI the user don’t
need to enter the height. Simply step on the weighing platform and as the weight
stabilizes adjust the head piece to measure the height, the scale will display the height
and BMI results.
It can also be used as mechanical height measurement rod. For mechanical measurement
range starts from (60~200cm) making it an ideal measurement rod for measuring height
of children and adults as well.
7.1
7.17.1
7.1.
. .
. HEIGHT ROD ASSEMBLY
HEIGHT ROD ASSEMBLYHEIGHT ROD ASSEMBLY
HEIGHT ROD ASSEMBLY
1. Fixing the bracket on the column of the scale using the screws provided with the height rod.

USER’S MANUAL
MA23-02/B
16
2. Extend the height measuring rod and tighten it in the bracket with the help of the appertaining screw.
7.2
7.27.2
7.2.
. .
. BATTERY I STALLATIO
BATTERY I STALLATIOBATTERY I STALLATIO
BATTERY I STALLATIO
AC1200M don’t need batteries to operate
AC1200D
a. Remove the battery cover at the rear of indicator.
b. Install 2-AAA size batteries.
c. Put the batter cover back.
WAR I G: If the height rod is not in use for long time, take out the batteries and store them separately, in case of
any leakage from battery would damage the measuring rod.
OTE: When the new batteries have been installed, it is recommended to reset the height rod using reset key.

USER’S MANUAL
MA23-02/B
17
7.3. KEY FU CTIO S
7.3. KEY FU CTIO S7.3. KEY FU CTIO S
7.3. KEY FU CTIO S
7.4
7.47.4
7.4.
. .
. CALIBRATI G THE HEIGHT ROD
CALIBRATI G THE HEIGHT RODCALIBRATI G THE HEIGHT ROD
CALIBRATI G THE HEIGHT ROD
AC1200D
o Slide the measuring rod downward completely
o Turn O AC1200D using O /OFF key
o If the height display is not on ‘120cm’, press Reset button to calibrate the height. It will be ‘120cm’
AC1200M
o Connect AC1200M with indicator
o Turn O the scale by pressing O /OFF key
o Press BMI key to check current height
o Slide the measuring rod downward completely
o If the height display is not ‘120cm’, press Reset button to calibrate the height. It will be ‘120cm’
Keys
KeysKeys
Keys
Description
DescriptionDescription
Description
O /OFF Press to switch on and off.
U IT To select the measurement unit between cm and inch.
HOLD
To enable value store function during measuring. Current height value of user will be stored
and displayed.
Press again to disable the function.
RESET
RESET key is for user to calibrate false reading. Slide right feet piece to the left at length of
35cm. Press RESET key to calibrate the height rod. LCD will display 35.0cm which means
the height rod has been well calibrated.

USER’S MANUAL
MA23-02/B
18
7.5
7.57.5
7.5.
. .
. USI G THE HEIGHT ROD
USI G THE HEIGHT RODUSI G THE HEIGHT ROD
USI G THE HEIGHT ROD
AC1200D
AC1200M
1. Slide up the measuring rod upward.
2. Slide down the head piece until slightly touches
the head.
3. When the head piece touches the head of the
person, display will show the exact height of the
person.
4. To lock the height on the display, press HOLD key.
5. Press HOLD key again to disable the Hold
function.
***Connecting USB wire to the scale will enable height
transfer function. You can calculate BMI with height and
weight taken by height rod and scale.
1. Slide the measuring rod upward.
2. Slide down the head piece until slightly touches
the head.
3. When the head piece touches the head of the
person, display will transfer height data to the
scale.
4. You can use BMI functions of scale to recall and
calculate BMI, weight and height.
***Connecting USB wire to the scale will enable height
transfer function. You can calculate BMI with height
and weight taken by height rod and scale.
Measuring height lower than 120 cm
Please use AC1200M as a mechanical height rod and press buckle as shown in the picture below and slide the head
piece down.
Under 120cm

USER’S MANUAL
MA23-02/B
19
7.7
7.77.7
7.7.
. .
. TECH ICAL SP
TECH ICAL SPTECH ICAL SP
TECH ICAL SPECIFICATIO S
ECIFICATIO SECIFICATIO S
ECIFICATIO S
Model
ModelModel
Model AC1200D AC1200M
Type
TypeType
Type
Scale mounted digital height rod
Keys
KeysKeys
Keys
Hold, Reset, Unit Reset Button
120~200cm (Digital measuring range)
Measurement range
Measurement rangeMeasurement range
Measurement range
120~200cm 60~200cm (Mechanical measuring range)
Graduations
GraduationsGraduations
Graduations
1mm
Dimensions
DimensionsDimensions
Dimensions
40x30x1780mm
Weight
WeightWeight
Weight
0.85kg
Power Supply
Power SupplyPower Supply
Power Supply
2 * AAA-size batteries -
Temperature range
Temperature rangeTemperature range
Temperature range
+10ºC up to +40ºC

USER’S MANUAL
MA23-02/B
20
8. TECHNICAL SPECI ICATIONS
Model: CS1300C
Capacity: 300 kg x 100 g
LCD Display: 1.0 inch LCD display with 5 and 1/2 digits
Max. external dimensions: Platform size: 550 x 550 mm / Height: 1160 mm
Power supply: AC adapter 15V 300mA / Rechargeable Battery
Key Functions: O /OFF,ZERO, PRI T, BMI, HOLD, PRE-TARE,TARE, CLEAR, E TER, 0~9, M1-5
Operation temperature: 5ºC / 35ºC
Table of contents
Other DAVI & CIA Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Calira
Calira Accucare BW 35 operating instructions

TQC Sheen
TQC Sheen GLOSSMETER GL0010 user guide

Fluke
Fluke Cable Analyzer DTX-ELT Brochure & specs

Emerson
Emerson Rosemount 285 Quick installation guide

Vitrek
Vitrek 4700 Operating and maintenance manual

Prosense
Prosense FMM50-1002 operating instructions