NOTE: Keep Alive (Pin 9) is only required if alkaline AA size battery is removed. Flight Time starts with either
Pin 3 or Pin 4 – use only one pin.
SPECIFICATIONS
nGreenwich Mean Time: 24 hour format.
nLocal Time: 12 hour format.
nFlight Time: Records in 99:59 standard.
nFlight Time Alarm: Full set range flight time.
nElapsed Time Count Up: Starts in minutes,
seconds, then hours, minutes up to 99:59 hrs.
nElapsed Time Count Down: Settable from
one second to 59 minutes, 59 seconds.
nElapsed Time Alarm: Activates at zero
when counting down.
nLCD Display
nBattery Type: AA size alkaline.
nKeep Alive Current: .00004 Amps.
nInput Current: .2 Amps.
nInput Voltage: 11 to 28 volts.
nVoltage Range: 8 volts to 32 volts ±.2 volts Typ.
-55°C to +100°C ±2°C Typ.
nTemperature Range: -67°F to +212°F.
nCrystal Reference: -40C to + 60C .001%.
nWeight: 5.02 ounces.
nWarranty: 1 year.
ELECTRICAL
MECHANICAL
5
4
3
2
1
9
8
7
6
- +
+
Alarm Out
Keep Alive .00004A
Ground to start Flight Time
Dimming 5V (240ma), 14V (240ma) or 28V (100ma) lighting
4V to 28V Starts Flight Time
Temperature Sensor (White)
14 to 28 Volts, 2A
Temperature Sensor (White/Blue Stripe)
GND
Audio Alarm
.25A
Battery
(),,#2%347!9
2%$7//$#)49%MERALD(ILLS#!

WWWDAVTRONCOM
2.10
1.375
2.83
1.675
.080
M803
Alkaline “AA” Battery
Locking Connector
Positronics MD9F-20J-VL
1.875
TYP. 2.22
2.375
TYP.
Mounting Hardware 4-40x3/8
DIGITAL CLOCK
M803
LCD Display
GREENWICH MEAN TIME
LOCAL TIME
FLIGHT TIME - Flight Time Alarm
ELAPSED TIME - Count Up, Count Down, Alarm
FEATURES - O.A.T. / VOLTS
ßONE button control steps sequentially through
E, F, C:
E - Voltage
F - O.A.T. Fahrenheit
C - O.A.T. Centigrade
ßAlways selects to read voltage on power up for
battery status check.
ßInput voltage - 11 to 28 volts.
ßInternal lighting 5v,14v or 28v specify when
ordering.
ß2.25” standard mount - wt. 5.02 oz.
MODEL 803
CLOCK OPERATION
Normal Operation
The SEL button selects what is to be displayed and
the CTL button controls what is being displayed.
Pressing SEL sequentially selects Local Time, Flight
Time, Elapsed Time, and back to UT. The CTL button
resets Flight Time, FT, back to zero when held down
for 3 seconds. The CTL button also starts and resets
Elapsed Time when momentarily pushed. Normal
operation of the 803 cannot accidentally reset time.
Setting Universal Time
Select UT for display with the SEL button. Simultane-
ously press both the SEL and CTL buttons to enter the
set mode. The tens of hours digit will start flashing.
The CTL button has full control of the flashing digit,
and each button push increments the digit. Once the
tens of hour is set, the SEL button selects the next digit
to be set. After the last digit has been selected and
set with the CTL button, a final push of the SEL button
exits set mode. The lighted annunciator will resume its
normal flashing, indicting the UT clock is running.
Setting Local Time
Select Local Time, LT, using the SEL button.
Simultaneously push the SEL and CTL buttons to enter
set mode. The tens of hours digit will start flashing.
The set operation is the same as for UT, except that
minutes are already synchronized with the UT clock
and cannot be set in Local Time.
Control/Select Disable
When there is no aircraft power applied to the clock
the CTL and SEL buttons are disabled.
Setting Flight Time Alarm
When Flight Time, FT, is displayed enter the set mode
by pressing both buttons simultaneously. The alarm
time is entered identically to UT setting. When the
Flight Time equals the alarm time the display will flash
and the alarm output activated. If FT was not being
displayed at the time the alarm becomes active, the
clock automatically selects FT for display. Pressing
either the SEL or CTL button turns off the alarm and
zeroes the alarm time. Flight Time is unchanged and
continues counting.
Flight Time Reset
FT must be displayed when resetting. Hold CTL down
for 3 seconds, or until 99:59 appears on the display.
Flight Time will be zeroed upon release of the CTL
button.
Elapsed Time Count Up
Select ET for display. Pressing the CTL button will start
ET counting. Elapsed Time counts up to 59 minutes, 59
seconds, and then switches to hours and minutes. It
continues counting up to 99 hours and 59 minutes.
Pressing the CTL button again resets ET to zero.
Elapsed Time Count Down
Select ET for display and enter set mode by pressing
both buttons simultaneously. A countdown from any
time, a maximum 59 minutes, and 59 seconds, can
be set. The time is entered the same as UT setting.
Once the last digit is set, pressing the SEL button exits
the set mode and the clock is ready to start the count-
down. Pressing the CTL button starts the countdown.
The alarm becomes active at zero, flashes the displays,
and enables the external alarm. Pressing either button,
SEL or CTL, will reset the alarm. After reaching zero the
ET counter will count up.
Test Mode
Hold the SEL button down for three seconds and the
display will indicate 88:88 and activate all four annun-
ciators.
Model 803
O.A.T & Volts Operation
Universal Time Local Time
Flight Time
Temperature Fahrenheit
Elapsed Time
Temperature Centigrade
The one red button controls steps through E, F, and C
and then repeats. The initial power up will always
select voltage. One press and release selects Outside
Air Temp in Fahrenheit. The next button operation
selects Outside Air Temp in Centigrade.

Other Davtron Clock manuals

Davtron 850B User manual

Davtron

Davtron 850B User manual

Davtron M811C User manual

Davtron

Davtron M811C User manual

Davtron M811C User manual

Davtron

Davtron M811C User manual

Davtron M877 User manual

Davtron

Davtron M877 User manual

Davtron M880A User manual

Davtron

Davtron M880A User manual

Davtron M880A User manual

Davtron

Davtron M880A User manual

Davtron 811C User manual

Davtron

Davtron 811C User manual

Davtron M850B User manual

Davtron

Davtron M850B User manual

Davtron M850 User manual

Davtron

Davtron M850 User manual

Davtron MB800 User manual

Davtron

Davtron MB800 User manual

Popular Clock manuals by other brands

La Crosse Technology WT-3161BK quick start guide

La Crosse Technology

La Crosse Technology WT-3161BK quick start guide

Oregon Scientific RM308P user manual

Oregon Scientific

Oregon Scientific RM308P user manual

Oregon Scientific RAR391P user manual

Oregon Scientific

Oregon Scientific RAR391P user manual

Meinberg GPS167SV operating instructions

Meinberg

Meinberg GPS167SV operating instructions

TFA 60.3001 Instruction manuals

TFA

TFA 60.3001 Instruction manuals

Simplex SIMPLEX 500 Operation manual

Simplex

Simplex SIMPLEX 500 Operation manual

nLight nDTC quick start guide

nLight

nLight nDTC quick start guide

GRA & AFCH Divergence Meter Operating	 instruction

GRA & AFCH

GRA & AFCH Divergence Meter Operating instruction

LEXIBOOK Design TimeProjector RP170 instruction manual

LEXIBOOK

LEXIBOOK Design TimeProjector RP170 instruction manual

Brainstorm Electronics DXD-8 Operation manual

Brainstorm Electronics

Brainstorm Electronics DXD-8 Operation manual

Oregon Scientific RM313PU user manual

Oregon Scientific

Oregon Scientific RM313PU user manual

Bodet Cristalys Ellipse quick start guide

Bodet

Bodet Cristalys Ellipse quick start guide

Craig CR45372 owner's manual

Craig

Craig CR45372 owner's manual

Pyramid 4000 Installation and operation instructions

Pyramid

Pyramid 4000 Installation and operation instructions

Nixie Clock IV-22 product manual

Nixie Clock

Nixie Clock IV-22 product manual

Hama 136224 operating instructions

Hama

Hama 136224 operating instructions

La Crosse Technology WS-8157U-A instruction manual

La Crosse Technology

La Crosse Technology WS-8157U-A instruction manual

PROFICELL WT 1613 instruction manual

PROFICELL

PROFICELL WT 1613 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.