Dedrone RF-100 User manual

IM-Inst-RF10021en ENGLISH
INSTALLATION
Manual
RF-100

Dedrone
2 IM-Inst-RF10021en
Legal Provisions
The information contained in these documents is the property of Dedrone GmbH. Any
publication, whether in whole or in part, requires prior written approval by Dedrone GmbH.
Internal reproduction used solely for the purpose of product evaluation or other proper use
is allowed and does not require prior approval.
The declaration of conformity is available on request at support@dedrone.com.
Copyright
This manual is the intellectual property of Dedrone GmbH and is protected by copyright. All
rights reserved.
Dedrone GmbH
Miramstraße 87
34123 Kassel
Germany
Fon +49 561 861799-0
Fax +49 561 861799-111
Email info@dedrone.com
©2018 Dedrone GmbH. All rights reserved.

Dedrone
IM-Inst-RF10021en 3
Content
1Safety..................................................................................................................................4
1.1 Symbols........................................................................................................................................4
1.2 Intended Use ...............................................................................................................................4
1.3 Safety Information .................................................................................................................... 5
2The RF-100......................................................................................................................... 6
3Unpacking .......................................................................................................................... 7
4Scope of Delivery.............................................................................................................. 7
5Installation......................................................................................................................... 8
5.1 Select the Mounting Place .......................................................................................................8
5.1.1 Mounting Location..........................................................................................................8
5.1.2 Mounting Surface ...........................................................................................................9
5.1.3 Mounting Orientation ....................................................................................................9
5.1.4 Mounting Device .............................................................................................................9
5.2 Power Supply and Required Tools........................................................................................10
5.3 Cable Requirements and Preparation (Crimp) ....................................................................11
5.4 Installation with Pole Mount................................................................................................. 12
6Integrate RF-100 in your DroneTracker ..................................................................... 14
7Cleaning ........................................................................................................................... 15
8Decommissioning ........................................................................................................... 15
8.1 Shut Down the RF-100 ........................................................................................................... 15
8.2 Dismantling ............................................................................................................................... 15
8.3 Disposal ...................................................................................................................................... 15
9Technical Data................................................................................................................. 16

1 Safety Dedrone
4 IM-Inst-RF10021en
1Safety
1.1 Symbols
Symbol Explanation
Indicates a situation which, if not avoided, can result in property damage
Information that is important for a specific goal, but is not safety-relevant
Indicates a requirement for meeting a specific goal
Desired result
A problem that might occur
Action to resolve a problem
1.2 Intended Use
The RF-100 is a passive, network-attached sensor for the detection of radio frequencies (RF). It
supplements the DroneTracker System with another level of detection. The RF-100 detects
targeted radio signals of different drones and remote controllers and sends the data, along
with an alert, to the DroneTracker System.
The RF-100 is intended for civil commercial and private use in conjunction with a DroneTracker
System.
The RF-100 is suitable for indoor and outdoor use.
Use this product only in accordance with the information provided in the enclosed
documentation and with the locally applicable legal standards and directives. Any other
application may cause personal injury or property damage.
Any use of the product other than that described in the intended use section does not qualify
as appropriate. The enclosed documentation is an integral part of this product. Keep the
documentation in a convenient place for future reference and observe all instructions
contained therein.
The type label must remain permanently attached to the product.
FCC and IC
This device complies with Industry Canada licence-exempt RSS standard(s) and complies with
Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may
cause undesired operation.

Dedrone 1 Safety
IM-Inst-RF10021en 5
Note: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Modifications:Any modifications made to this device that are not approved by Dedrone GmbH
may void the authority granted to the user by the FCC to operate this equipment.
Caution!
To prevent permanent exposure, the device should be installed and operated
with a minimum distance of 20 cm (7.87 in) between the device and your body.
1.3 Safety Information
Read, follow and retain all of the following safety instructions. Heed all warnings on the unit
and in the operating instructions before operation.
Warning! Setup should be carried out by trained personnel only, in accordance
with the national electric code, ANSI/NSPA, and all local country codes.
Do not attempt to service this device yourself. Refer all servicing to qualified
service personnel. This device has no user-serviceable internal parts.
Whenever any damage to the device has occurred, unplug the devices from the
power source by disconnecting the patch cable and refer servicing to qualified
service personnel. Such damages can be:
•the patch cable is damaged
•an object has fallen on the device
•the device has been dropped, or its enclosure has been damaged
•the device does not operate normally when the user follows the operating
instructions correctly
Adjust only those controls specified in the operating instructions. Improper
adjustment of other controls may cause damage to the unit.
Despite careful construction, electrical devices can cause fires. Do not mount the
RF-100 in areas containing highly flammable materials or gases. Do not mount the
RF-100 in a potentially explosive atmosphere.
Do not install product near any heat sources such as radiators, heaters, exhaust air
systems or other equipment (including amplifiers) that produce heat.

2 The RF-100 Dedrone
6 IM-Inst-RF10021en
2The RF-100
The RF-100 is a passive, network-attached sensor for the detection of radio frequencies (RF).
The RF-100 detects targeted radio signals of different drones and remote controllers and
sends the data, along with an alert, to the DroneTracker System.
Parts of the RF-100
A Power button D RF Mounting Plate
B RF-100 E Network socket (covered)
C Antenna
It scans a wide frequency band for radio frequencies and classifies them. The data is recorded
and available on the DroneTracker user interface.
A
B
E
D
C

Dedrone 3 Unpacking
IM-Inst-RF10021en 7
3Unpacking
This equipment should be unpacked and handled with care. Check the exterior of the packaging
for visible damage. If an item appears to have been damaged in shipment, notify the shipper
immediately.
4Scope of Delivery
Verify that all the parts listed in the scope of delivery are included. If any items are missing,
notify your Dedrone Partner.
Do not use this product if any component appears to be damaged. Please contact Dedrone in
the event of damaged goods.
1 x RF-100
4 x Antenna (2x short, 2x long)
1 x RF Mounting Plate
1 x Pole Mount
2 x Strap
1 x Bag with 2x screws Torx M5, 4x flat washer, 2x nuts
1 x Installation manual
1 x Bag with 1x environmentally sealed Ethernet crimp connector, 1x RJ45 plug
The original packing carton is the safest container in which to transport the unit and must be
used if returning the unit for service. Save it for possible future use.

5 Installation Dedrone
8 IM-Inst-RF10021en
5Installation
5.1 Select the Mounting Place
5.1.1 Mounting Location
The position of the RF-100 has strong impacts to the detection range. The RF-100 is designed
for a mast mount. Make sure that a suitable mast is available (diameter between 1.2 in to 8.66
in (40 mm to 220 mm)).
For ideal results the location should fulfill the following conditions:
□clear view over the area
□elevated position (minimum 3 m)
Select a secure installation location and mounting position for the device. Ideally, this is a
location where the device cannot be interfered with, either intentionally or accidentally.
Do not install the device near the following objects:
•Walls because these share the detection area and prevent classification of signals behind
the wall
•Any excessive heat sources
•Any overhead power lines, power circuits, or electrical lights, or where there is a chance
of electrical discharge
•Behind metal surfaces or vaporized glass because this could reduce the detection range
Note the properties of each RF-100.This is needed for service and for correct
configuration. You can find all information on the type label on the backside of the
RF-100.
We recommend the table below. The following information is important:
•Serial number
•MAC address
•Position
Serial Number MAC Address Position

Dedrone 5 Installation
IM-Inst-RF10021en 9
Overvoltage Protection
For safe mounting in an exposed position overvoltage protection must be observed.
Ensure that the mast is connected to the lightning conductor of the building. The RF-100 itself
must not be grounded directly. The lightning conductor must be installed at least 5 ft (1.5 m)
above the RF-100.
Lightning Protection Installation with a RF-100
Ensure that the location has the appropriate clearance from power and lightning conductors,
in accordance with NEC725 and NEC800 (CEC Rule 16-224 and CEC Section 60).
5.1.2 Mounting Surface
Make sure the selected mounting surface is capable of supporting the combined weight of the
RF-100 (6.8 lb (3.1 kg)) and mounting hardware under all expected conditions of load, vibration,
and temperature.
5.1.3 Mounting Orientation
The orientation of the device itself does not have any effect for the performance. Important
for a good result is the orientation of the antenna. Both antennasshould be orientated
skywards.
5.1.4 Mounting Device
To mount the RF-100 with a mount other than the one supplied, note the following
requirements for the mounting equipment:
□licensed for outdoor use

5 Installation Dedrone
10 IM-Inst-RF10021en
□safe and stiff load of 6.8 lb (3.1 kg)
□matching for the holes of the RF Mounting Plate
Dimensioning of the holes of the RF Mounting Plate
A Holes for the Mast Mount
5.2 Power Supply and Required Tools
Power Supply
The RF-100 does not need any additional power supply connection. The power supply is
provided by the connected switch with activated active PoE+ (802.3at).
•Make sure, that your network has activated active PoE+ (802.3at).
Note: Data transfer is only possible with a suitable PoE switch.
Required Tools
•Screwdriver
•Hex key: 4 mm
•Socket wrench: 8 mm (5/16") and 7 mm ( 9/32” )
•Crimping tool
For an environmentally sealed connection to the RF-100, it's necessary to crimp the
supplied connector to the laid patch cable (see 5.3 Cable Requirements and Preparation
(Crimp), page 11).
•Ladder or lift truck, depending on the mounting location
150
95
35
80
A
A

Dedrone 5 Installation
IM-Inst-RF10021en 11
5.3 Cable Requirements and Preparation (Crimp)
Cable Requirements
Type Cat-6 Patch Cable
Recommendation: Cat-7 Patch Cable
Maximum Length 328 ft (100 m)
For longer distances a PoE extender is required
External Diameter 3.5 mm – 7.5 mm
Cable Preparation
For a weather resistant connection to the RF-100, it is necessary to crimp the supplied
environmentally sealed Ethernet connector to the patch cable.
1Cut the RJ45 plug off the laid cable. Keep the cut off plug to check the wiring
standard later.
2Screw the gland off the connector body.
3Thread the gland nut and the connector body
onto the cable.
4Remove the cable jacket carefully. Therefore take care not to damage the braid and
foil.
5Fold back the braid and foil over the cable jacket.
Note: 25 mm (1”) of free conductors are needed.
6Unravel the conductors, sort the conductors in
the required wiring standard (568-A or 568-B)
and push the conductors all the way in the plug.
The required wiring standard can be checked on
the previous cut-off RJ45 plug.
Position
568-A 568-B
1
White/Green
White/Orange
2
Green
Orange
3 White/Orange White/Green
4
Blue
Blue
5
White/Blue
White/Blue
6
Orange
Green
7 White/Brown White/Brown
8
Brown
Brown
7Crimp the RJ45 plug with the crimping tool.
8Push down the latching clip of the plug and press the connector body all the way to
the stop over the RJ45 plug.
9Put the gland nut over the connector body and screw down the gland nut on the
connector body.
1
Front Face View

5 Installation Dedrone
12 IM-Inst-RF10021en
5.4 Installation with Pole Mount
Requirements:
□Desired mounting place fulfills the requirements (see 5.1 Select the Mounting Place, page 8)
□Diameter of the pole: between 1.2 in to 8.66 in (40 mm to 220 mm)
Procedure:
1Loosen the knurled head screws on both sides of
the RF-100 and unhook the RF-100 from the RF
Mounting Plate.
2Screw the RF Mounting Plate onto the Pole Mount.
Therefore note the following:
•Use the shown holes.
•The screw guidance of the RF Mounting Plate
shows to the top.
•Put a flat washer between
oscrew head and RF Mounting Plate and
onut and Pole Mount.
•Screw down the nut with a 8 mm socket
wrench.
3Run the straps through the slashes of the Pole
Mount.
4Mount the the Pole Mount to the pole:
•Hold the Pole Mount with the RF Mounting
Plate at the desired height of the pole.

Dedrone 5 Installation
IM-Inst-RF10021en 13
•Lay the straps around the pole
•Put the strap in the slash under the screw and
tighten it with the socket wrench (7 mm)
appropriately.
5Hook the RF-100 in the screw guidance of the RF
Mounting Plate.
6Screw down the 2 knurled head screws carefully at
both sides in the lower holes.
Thereby be careful not to tighten the screws until
the RF Mounting Plate does not deform.
7Screw the antennas on the screw threads at the top
of the RF-100.
Therefor note the correct positioning of the short
and long antenna.
8Adjust the antenna of the RF-100 in the desired orientation. The antennasshould be
orientated skywards.
9Make sure that the mast is grounded (see Requirements Overvoltage Protection,
page 9).
10 Connect the patch cable to the RF-100 and turn the connector gland until it is locked
(for a correct cable preparation see 5.3 Cable Requirements and Preparation (Crimp),
page 11).
If the patch cable is connected to the network, the RF-100 boots automatically
and after approximately 1 second the blue button at the RF-100 illuminates,
indicating that the hardware is ready.
The patch cable is connected to the network and the RF-100 does not boot
automatically after approximately 1 second?
Push the blue button and wait for it to illuminate.
Make sure that active PoE+ (802.3at) is activated in your network.
short
long

6 Integrate RF-100 in your DroneTracker Dedrone
14 IM-Inst-RF10021en
6Integrate RF-100 in your DroneTracker
To connect to the RF-100, it is necessary to know the IP address of the RF-100. When the RF-
100 is connected to your network, the router or DHCP-Server automatically assigns an IP
address to the RF-100. To find out the IP address, you need two pieces of important
information:
•MAC address of the RF-100 (on the type label and should be noted in chapter
5.1.1 Mounting Location, page 8)
•The network name of the RF-100 always starts with DR…
In case of difficulties please consult your network administrator.
Requirements:
□RF-100 is installed
□RF-100 is connected to the network
□The power supply is working and the power button at the RF-100 illuminates blue
□The IP address of the RF-100 is known
Procedure:
1Start your web browser.
For an optimal use, Dedrone recommends Chrome or Firefox.
2Enter the IP address of the DroneTracker Server in the address field of your browser.
3Log in the DroneTracker UI. The default login credentials are:
User: admin Password:
dedrone
The DroneTracker user interface appears.
4Choose OPTIONS > Site Configuration.
5Choose in the Site Explorer and choose [Add] > Multi Sensor / RF Sensor.
The window Discovered Sensors appears.
6Select the desired RF-100 and choose [OK].
The RF-100 appears in the Site Explorer.
7To sort the RF-100 in the Site Explorer, drag and drop the element to the desired
position.
8Choose [Save changes].
The window Site Configuration disappears.
For further information consult chapter “First Steps” of the integrated online help in
the DroneTacker UI.

Dedrone 7 Cleaning
IM-Inst-RF10021en 15
7Cleaning
Some cleaners damages the housing
Some cleaners can damage the housing or antenna of the RF-100. Never use glass cleaner or
other solvent cleaner to clean the RF-100.
•Use solvent-free cleaner to clean the RF-100.
8Decommissioning
8.1 Shut Down the RF-100
RF-100 breaks
By disconnecting the cable without shut down the RF-100, the RF-100 could break.
•Always shut down the RF-100 in the DroneTracker UI before disconnecting the cable.
Procedure:
1Log in to the DroneTracker user interface.
2Choose OPTIONS > Site Configuration.
3Right-click on the desired RF-100.
4Choose System > Shutdown hardware.
8.2 Dismantling
Hot surface during operation
Depending on the evironment the surface of the RF-100 could get hot.
•Before dismantling the device wait 30 min after shut down the RF-100.
8.3 Disposal
Dispose the RF-100 at the end of its service life in accordance with the disposal
regulations for electronic waste which apply at the installation location at that
time. Alternatively, send it back to Dedrone GmbH with shipping paid by the
sender, and labeled "ZUR ENTSORGUNG" ("FOR DISPOSAL").

9 Technical Data Dedrone
16 IM-Inst-RF10021en
9Technical Data
L x W x H 7.7” x 3.7” x 17.3” (195 mm x 95 mm x 440 mm)
Height without antenna: 9.8” (250 mm)
Operating Temperature -4 °F to +122 °F (-20 °C to +50 °C)
Weight 6.8 lb (3.1 kg)
Ingress Protection Rating IP65 *
Connectivity Fast-Ethernet (100 Mbit/s)
Power Supply Active PoE+ (802.3at)
Power Consumption 15 W (typ.)
Range 0.65 mi (1.0 km)
in good conditions up to 1.3 mi (2 km)
Radio Frequency Omnidirectional passive detecting and classification
* No ingress of dust; complete protection against contact (dust tight). A vacuum must be applied. Water projected by a nozzle
(6.3 mm) against enclosure from any direction shall have no harmful effects.

Other manuals for RF-100
1
Table of contents
Popular Measuring Instrument manuals by other brands

CORNING
CORNING 315 installation manual

Spectrum Technologies
Spectrum Technologies LightScout 3415Z product manual

SubSurface Instruments
SubSurface Instruments LC-5000 Simple operation manual

ComSonics
ComSonics Qualifier X-Ray user guide

Rohde & Schwarz
Rohde & Schwarz R&S ZNB user manual

Hanna Instruments
Hanna Instruments HI96786C instruction manual