Defensor PH15 User manual

2526397 EN 0801
Defensor PH15/PH15A
OPERATING INSTRUCTIONS
Adiabatic Humidifiers


1 Introduction 4
1.1 To the very beginning 4
1.2 Notes on the operating instructions 4
2 For your safety 6
3 Product Overview 8
3.1 Unit versions 8
3.2 Unit construction 8
3.3 Operating panel 9
3.4 Identification of the unit 10
3.5 Functional description/Operating modes 10
3.6 Options 11
3.7 Accessories 12
3.8 Standard delivery 12
4 Commissioning 13
4.1 Unpacking the unit and checking the scope of delivery 13
4.2 Transporting/storing the unit 13
4.3 Choose location 14
4.4 Connecting the water supply (PH15A only) 15
4.5 Putting the unit into operation 16
5 Operation 17
5.1 Filling the water tank (PH15 only) 17
5.2 Switching the unit on and off 18
5.3 Menu overview 19
5.4 Unit settings (normal operating mode) 20
5.4.1 Setting the desired humidity value 20
5.4.2 Setting the fan step 21
5.4.3 Selecting the operating mode (Humidifying mode) 22
5.4.4 Switching the buzzer on and off 22
5.4.5 Calling timer level 23
5.4.6 Selecting the dialogue language 23
5.5 Program operation 24
5.5.1 Calling the timer level 24
5.5.2 Activating/Deactivating the program mode 25
5.4.3 Setting the current time 25
5.5.4 Setting the starting points and the operating programs 26
5.6 Locking/unlocking the keyboard 27
6 Maintenance 28
6.1 Maintenance intervals 28
6.2 Maintenance work 29
6.2.1 Disassembling the unit 29
6.2.2 Cleaning work 30
6.3 Notes on cleaning agent 32
6.4 Reassembly of the unit 33
6.5 Resetting the filter changing message 34
7 Fault elimination 35
7.1 Event messages 35
7.2 Warning messages 35
7.3 Error messages 36
7.4 What, if...? 37
7.5 Notes on fault elimination 38
8 Taking out of service/Disposal 39
8.1 Taking out of service 39
8.2 Disposal/Recycling 39
9 Unit specifications 40
10 Appendix 41
10.1 Wiring diagram 41
10.2 Spare parts list PH15 42
10.3 Spare parts list PH15A 44
Contents

4
Limitation
The subject of this operating instructions are the air purifiers/air humidifiers Defensor PH15
and PH15A. The various accessories are only described insofar as this is necessary for proper
operation of the equipment. Further information on accessories can be obtained in the respective
instructions.
This operating instructions are restricted to the installation, commissioning, operation, servicing
and trouble shooting of the air purifier/air humidifier Defensor PH15/PH15A and is meant for well
trained personnel being sufficiently qualified for their respective work.
The operating instructions are supplemented by various separate items of documentation (e.g. manu-
als for accessories). Where necessary, appropriate cross-references are made to these publications
in the operating instructions.
1 Introduction
We thank you for having purchased an air purifier/air humidifier Defensor PH15 or PH15A.
The air purifier/air humidifier Defensor PH15/PH15A incorporates the latest technical advances and
meets all recognized safety standards. Nevertheless, improper use of the Defensor PH15/PH15A
may result in danger to the user or third parties and/or impairment of material assets.
To ensure a safe, proper, and economical operation of the air purifier/air humidifier Defensor PH15/
PH15A, please observe and comply with all information and safety instructions contained in the
present operating instructions as well as the instructions given in the manuals for the components
used in the humidification system.
If you have questions, which are not or insufficiently answered in this documentation, please contact
your Defensor supplier. They will be glad to assist you.
1.2 Notes on the operating instructions
1.1 To the very beginning

5
Symbols used in this manual
CAUTION!
The catchword “CAUTION” designates notes in this operating instructions that, if
neglected, may cause damage and/or malfunction of the unit or other material
assets.
WARNING!
The catchword “WARNING” used in conjunction with the general caution symbol
designates safety and danger notes in this operating instructions that, if neglected,
may cause to injury to persons.
DANGER!
The catchword “DANGER”” used in conjunction with the general caution symbol
designates safety and danger notes in this operating instructions that, if neglected,
may lead to severe injury or even death of persons.
Safekeeping
Please safeguard this operating instructions in a safe place, where it can be immediately accessed.
If the equipment changes hands, the documentation should be passed on to the new operator.
If the documentation gets mislaid, please contact your Defensor supplier.
Language versions
This operating instructions are available in various languages. Please contact your Defensor supplier
for information.
Copyright protection
The present operating instructions are protected under the Copyright Act. Passing-on and reproduc-
tion of the manual (or part thereof) as well as exploitation and communication of the contents are
prohibited without written permission by the manufacturer. Violation of copyright terms is subject
to legal prosecution and arises liability for indemnification.
The manufacturer reserves the right to fully exploit commercial patent rights.

6
2 For your safety
General
Every person working with the Defensor PH15/PH15A must have read and understood the Operating
instructions before carrying out any work.
Knowing and understanding the contents of the Operating instructions is a basic requirement for
protecting the personnel against any kind of danger, to prevent faulty operation, and to operate the
unit safely and correctly.
All ideograms, signs and markings applied to the unit must be observed and kept in readable
state.
Qualification of personnel
All actions described in the present Operating instructions (installation, operation, maintenance,
etc.) must be carried out only by well trained and sufficiently qualified personnel authorised by
the owner.
For safety and warranty reasons any action beyond the scope of this manuals must be carried out
only by qualified personnel authorised by your Defensor supplier.
It is assumed that all persons working with the Defensor PH15/PH15A are familiar and comply with
the appropriate regulations on work safety and the prevention of accidents.
This unit may not be used by persons (including children) with reduced physical, sensory or mental
abilities or persons with lacking experience and/or knowledge, unless they are supervised by a person
responsible for their safety or they received instructions on how to operate the unit.
Children must be supervised to make sure that they do not play with unit.
Intended use
The air purifier/air humidifier Defensor PH15/PH15A is intended exclusively for air purification and
air humidification within the specified operating conditions (see chapter 9 “Product specifica-
tions”). Any other type of application without the express written consent of the manufacturer is
considered as not conforming with the intended purpose and may lead to the Defensor PH15/PH15A
becoming dangerous.
Operation of the equipment in the intended manner requires that all the information in these
instructions are observed (in particular the safety instructions).

7
Danger that may arise from the unit
– The Defensor PH15/PH15A is mains powered.
DANGER!
One may get in touch with live parts when the unit is open. Touching live
parts may cause severe injury or danger to life.
Prevention: Before carrying out any work set the Defensor PH15/PH15A out of operation
(switch off the unit, disconnect it from the mains, close water supply) and secure
the unit against inadvertent power-up.
– Poorly maintained humidifiers can endanger your health.
WARNING!
If the Defensor PH15/PH15A is insufficiently maintained harmful germs can
build up in the water and the filters an can affect the ambient air.
Prevention: The Defensor PH15/PH15A has to be cleaned in regular intervals according to
chapter 6 “Maintenance”. The cleaning work has to be carried out correctly and
the evaporator mat as well as the filters have to be replaced after the specified
lifetime.
Handling the mains cable
Handle the mains cable with care: keep it away from sharp edges and do not jam or strain it.
Never remove the mains plug by pulling the mains cable. Make sure your hands are absolutely dry
when pulling the plug out of the socket.
Lay out the mains cable so that it does not become a stumbling trap.
Connect mains cable only to a mains socket with protection earth. Any extension cable used must
be equipped with a protection earth too.
Behaviour in case of danger
If it is suspected that safe operation is no longer possible, then the Defensor PH15/PH15A should
immediately be disconnected from the mains (disconnect mains connector) and secured against
accidental power-up. This can be the case under the following circumstances:
– if the Defensor PH15/PH15A is damaged
– if the Defensor PH15/PH15A is no longer operating correctly
– if connections and/or piping are not sealed
– if the mains cable is damaged
All persons working with the Defensor PH15/PH15A must report any alterations to the unit that may
affect safety to the owner without delay.
Prohibited modifications to the unit
No modifications must be undertaken on the Defensor PH15/PH15A without the express written
consent of the manufacturer.
For the replacement of defective components use exclusively original accessories and spare parts
available from your Defensor supplier.

8
3 Product Overview
3.1 Unit versions
1
2
3
4
5
6
7
8
10
9
13
11
9
14
12
15
The Defensor PH15/PH15A air purifier/air humidifier is available in two basic versions:
– PH15: version with integrated water tank
– PH15A: version with inlet valve for the connection to the drinking water system
Both versions are equipped as standard with a coarse dust filter and evaporator mat to operate the
unit as a humidifier (winter time operation).
1 Air inlet lattice
2 Coarse filter
3 Radial fan
4 Centrifuge
5 Mobile base with cover
6 Flock-coated evaporator mat or activated
carbon evaporator mat
7 Droplet trap
3.2 Unit construction
PH15
8 Coarse dust filter or Quattro filter
9 Carriage with water tank
10 Operating panel with display
11 Type plate
12 3 pole mains cable
13 Silver ionisation electrodes (option)
14 Level switch
15 Safety switch

9
1 Air inlet lattice
2 Coarse filter
3 Radial fan
4 Centrifuge
5 Mobile base with cover
6 Flock-coated evaporator mat or activated
carbon evaporator mat
7 Droplet trap
8 Coarse dust filter or Quattro filter
9 Carriage
10 Operating panel
11 Type plate
12 3 pole mains cable
13 Silver ionisation electrodes (option)
14 Level switch
15 Safety switch
16 Water filter
17 Inlet valve
1
2
316
17
4
5
6
7
8
10
9
13
11
9
14
15
12
PH15A
3.3 Operating panel
1 LC display
2 <ESC> key
3 Arrow keys
4 Error indicator
5 <I/0> key (On/Off)
6 <Enter> key
ESC Enter I / 0
1
2
3
4
5
6

10
Functional description
The radial fan (1) takes in the air from the top via the coarse filter (2). After passing through the
evaporator mat (3) (or the activated carbon evaporator mat) and the coarse dust filter (4) (or the
Quattro filter) the air is blown out via the outlet lattice on both sides of the unit.
The unit continuously measures the air humidity in the room with the integrated humidity sensor
and compares it with the set reference humidity value. If the actual value (e.g. 40 %rh) is below the
reference value (e.g. 45 %rh) the centrifuge (5) starts and projects fine drops towards the evaporator
mat. The air passing through the evaporator mat absorbs the humidity.
The coarse dust filter retains dust particles up to 100 µm. If the Defensor PH15/PH15A is equipped
with a Quattro filter it can retain dust particles up to 0.1 µm. In addition the activated charcoal layer
in the Quattro filter removes unpleasant odour.
The water level in the base tub is monitored by the level regulating valve in the water tank (Defensor
PH15) or by the level controlled inlet valve (Defensor PH15A).
3.5 Functional description/Operating modes
3.4 Identification of the unit
The identification of the unit is found on the type plate (for the location of the type plate see unit
overview):
Type designation Serial number Month/Year
Unit voltage
Admissible water supply pressure
(PH15A only)
Power consumption
2
1
3
5
6
4
Walter Meier (Climate International) Ltd. 8808 Pfäffikon
PH15 XXXXXXX
AC 220...240V / 50...60 Hz max. 72 W
Made in Switzerland
02.07
Inlet pressure = 0.5...6 bar
Field with certification symbols

11
Operating modes
The Defensor PH15/PH15A can be operated in the following operating modes:
– Operation as air humidifier
In the humidifier mode the ventilator and the centrifuge are running only, if the actual humidity
value is below the set reference value.
Note: if the actual humidity value remains below the reference value for a prolonged period of
time, the fan must be switched to the next highest level.
– Operation as air purifier with humidification
In this operating mode the fan is running continuously. The centrifuge is only switched on if the
actual humidity value is below the set reference value.
– Operation as air purifier without humidification
In this operating mode the fan is running continuously. The centrifuge remains switched off.
3.6 Options
Defensor PH15 Defensor PH15A
Silver ionisation
Assembly kit to equip the unit with silver ionisation electrodes
to degerminate the water in the base tub with silver ions.
Note: The silver ionisation kit must be installed and config-
ured only by a service technician of your Defensor repre-
sentative.
• •
Radio humidistat
The radio humidistat can be used instead of the integrated
humidistat. The maximum range of the radio humidistat in
an open room is 25 m
Note: the radio humidistat as well as the receiver board must
be installed and configured only by a service technician of
your Defensor representative.
• •
Leakage sensor
Assembly kit to equip the Defensor PH15/PH15A with a
leakage sensor. If the leakage sensor detects a leakage,
the inlet valve (PH15A only) is closed and error message
is triggered.
Note:The leakage sensor must be installed and configured
only by a service technician of your Defensor representa-
tive.
• •

12
The air purifier/air humidifier Defensor PH15/PH15A is delivered in a cardboard box (B: 816 mm x H:
684 mm T: 456 mm, transport weight: 28 kg), ready for use. The standard delivery includes:
– Air purifier/Air humidifier Defensor PH15 or PH15A, equipped with the “Winter” filter set
(coarse dust filter, flock-coated evaporator mat) and the options as ordered.
– Cleaning brush
– Filling hose approx. 1,2 m (PH15 only)
– Water supply pipe with R 3/4" female connector approx. 0,3 m (PH15A only)
– Operating instructions (this document)
The ordered accessories with operating instructions according chapter 3.6 are packed separately.
3.7 Accessories
Defensor
PH15
Defensor
PH15A
Filter set “Winter”
Filter set for the operation of the unit during winter season. The
set consist of:
– Coarse filter (air intake)
– Flock-coated evaporator mat
– Coarse dust filter
• •
Filter set “Summer”
Filter set for the operation of the unit during summer season.The
set consist of:
– Coarse filter (air intake)
– Activated carbon evaporator mat
– Quattro filter
• •
Filter valve “Z261”
Filter valve to use as a shut-off valve in the water supply line
(PH15A only)
•
3.8 Standard delivery

13
4.1 Unpacking the unit and checking the scope of delivery
Unpacking the unit
Open the packing and remove the unit and the accessories. Check the delivery for completeness
(standard delivery, see chapter 3.8). Please contact your Defensor supplier in case something is
lacking, they will be glad to send you the missing part without delay.
Please check the equipment for damage. Please report any damage to your Defensor supplier and
to the carriers, as required.
Packaging
The original packaging of the Defensor PH15/PH15A was designed for optimum safety during trans-
portation. Please preserve the original packing material in case you once have to return the unit for
some reason.
In case you wish to dispose of the packaging, observe the local regulations on waste disposal. Never
dispose of the packaging to the environment.
4 Commissioning
4.2 Transporting/storing the unit
Transport
The Defensor PH15/PH15A is equipped with built-in rollers for effortless displacement. If you have
to lift the unit for displacement or relocation ask another person for assistance (weight of the empty
unit: 25 kg).
Important! To prevent the water from running out make sure the water tank and the base tub are
empty before moving the unit.
Storing
Store the unit in a protected area meeting the following requirements:
– room temperature: 1 ... 40 °C
– room humidity: 10 ... 75 %rh

14
4.3 Choose location
Please observe the following notes for the correct positioning of the Defensor PH15/PH15A:
min. 100 mm
min. 150 mm
min. 150 mm
min. 400 mm
– Place the unit on a solid horizontal surface, if possible free-standing and freely accessible (observe
minimal distances).
– A mains socket should be located close to the unit.
– To ensure the entire volume of air is fully recirculated, do not place the unit in recessed compart-
ments, closed corridors, behind curtains, etc.
– Do not place any objects on the unit (performance reduction).
– Make sure the air flow is not directed towards obstacles (pillars, furniture, etc.) or cold outer walls
(risk of condensation).
– Continuous direct sunlight is harmful for the unit and can affect the correct function of the inte-
grated humidity sensor. Therefore do not expose the unit to continuous direct sunlight.
– The unit must not be installed in hazardous locations and in rooms where water splashes may
occur.

15
1.
3.
4.
2.
After locating the unit:
• Lock the wheels of the carriage
unlock
lock
4.4 Connecting the water supply (PH15A only)
The water supply has to be connected to the unit by a qualified specialist according to the illustration
below. The installation data has to be maintained.
Important!The local regulations regarding the connection of units to drinking water systems must
be observed.
Drinking water without additives:
– Admissible water pressure: 0.5...6.0 bar
– Admissible water temperature: 5...40 °C
Plug-in coupling ø 10 mm
Filter valve (accessory “Z261”)
• Completely unwind the mains cable (at the point of the delivery the mains cable is winded up in
the unit) and take it out of the unit as shown below.
Water pipe ø 10/6 mm
with R 3/4" connector
ø 10/6 mm

16
4.5 Putting the unit into operation
Proceed as follows to put the Defensor PH15/PH15A into operation:
• PH15: fill the water tank (see chapter 5.1)
PH15A: open the shut-off valve in the water supply line.
• Connect unit to the mains.
CAUTION! Make sure the required supply voltage (see type plate) matches the local mains
voltage, otherwise do not connect the Defensor PH15/PH15A to the mains!
CAUTION! The Defensor PH15/PH15A must be connected only to grounded mains. Never
connect the unit to an outlet without protective earthing.
The Defensor PH15/PH15A is now ready for operation. The next chapter provides detailed informa-
tion on the operation of the unit.

17
2.
1. 3.
5 Operation
5.1 Filling the water tank (PH15 only)
3
1 2
4
Place an absorbent cloth below the unit.
Drinking water without additives
To maintain the monitoring
of the unit during filling,
neither switch off the unit
nor disconnect it from the
mains!
1.
3.
4.
2.
Important! Screw on tank
cap until it comes to a stop!
After reinstalling the water tank wait by the
unit until the filling sound stops.
1.
3.
4.
2.
If the lock is not released (step 3), the carriage remains
fixed to the unit in open position.

18
5.2 Switching the unit on and off
Switching the unit on
• Press the <O/I> key.
The unit loads the settings that were active when the device was shut down last. Upon completion
the operating display appears.The look of the operating display depends whether the Defensor
PH15/PH15A is operated in “Normal operating mode” or in “Program mode”.
PH 15 Mo 12:32
Act 38%rH H2
Unit designation
PH15
Day of the week (appears only in program mode)
Format: “Mo”, “Tu”, “We”, “Th”, “Fr”, “Sa”, “Su”
Hour (appears only in program mode)
Format: “hh:mm”
Fan step
1, 2, 3, 4 or A (automatic operation)
Note: If humidification is active and the fan step is set to “A”, the fan
will be controlled automatically, based on the difference between
the actual and reference humidity. If humidification is inactive the
“A” setting corresponds to fan step “1”.
Mode of operation (Humidifying mode)
H: Air humidification
P: Air purification with humidification
_: Air purification without humidification
Actual humidity value in %rh
Note: The actual humidity value is always displayed (even in air
purification mode).
The fan starts in all operating modes with a delay of approx. 1 minute. Until the fan starts the
operating mode and the fan step are blinking.
If, after switching on the unit a warning or error message is displayed, please observe the
notes in chapter 7.
Switching the unit off
• Press the <O/I> key.
The currently active settings will be stored upon shutdown.

19
Timer
On
Time
Mo 12:00
Monday 1
18:00 45%rH H3
Monday 2
--:-- 45%rH H0
Sunday 1
--:-- 45%rH H0
PH 15
Act 38%rH H2
Set value
42%rH
Fan power
1
Humidifying mode
Humidify
Buzzer
On
Timer
Adjust
Language
english
5.3 Menu overview
The following diagram shows the menu overview of the Defensor PH15/PH15A. After switching on,
the unit is in the user level.
User level Timer level
In the user level you can define the set-
tings for the normal operating mode (see
chapter 5.4).
In the timer level you can define and activate
the program mode (see chapter 5.5).
Sunday 2
22:00 45%rH H0

20
5.4 Unit settings (normal operating mode)
5.4.1 Setting the desired humidity value
modify
confirm
cancel
Note: The reference humidity value can be modified only if program mode is deactivated (see chap-
ter 5.5).
Setting range: 30...90 %rH
Factory setting: 45 %rH
Notes on setting: The optimum reference value depends on various factors. For apartments we
recommend a value of 40 – 45 %rH.
Note: After initial commissioning or replacement of the vaporizer mat the humidification perform-
ance of the Defensor PH15/PH15A will be slightly reduced because the evaporator mat takes a
few days to become fully saturated with water. Maximum performance is available after one week,
approximately.
Furthermore, the humidification performance depends on the ambient temperature.
30...90 %rH
Standard operating display
(see chapter 5.4.2)
Set value
45%rH
Set value
New Value
Set value
Old Value
Set value
45%rH
This manual suits for next models
1
Table of contents
Other Defensor Humidifier manuals