Del ozone Solar Eclipse User manual

Ozone + UV Sanitation System
Installation & Operations Manual
3580 Sueldo Street, San Luis Obispo, CA 93401 | 800.676.1335 | o3info@delozone.com | www.delozone.com
4-2005-01 Rev.A

Solar Eclipse Installation & Operations Manual
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS.
• Read this manual completely before attempting installation. Failure to install in accordance with the installation
instructions could void warranty and result in injury or death.
• All permanent electrical connections should be made by a qualified electrician.
• A pressure wire connector is provided on the outside of the unit to permit connection to a minimum No. 8 AWG (8.4
mm2) solid bonding conductor between this point and any metal equipment, metal enclosures of electrical equipment,
metal water pipes, or conduit within 10 feet (3.05 meters) of the unit as needed to comply with local requirements.
• Install at least 5 feet (3.05 meters) from wall of pool. Install ozone generator no less than one (1) foot above
maximum water level to prevent water from contacting electrical equipment. Install in accordance with the installation
instructions.
• Follow all applicable electrical codes.
• Electric shock hazard. Be sure to turn power OFF and disconnect from power source before any service work is
performed. Failure to do so could result in serious injury or death.
• The Solar Eclipse must be installed in an outdoor location, or indoors in a forced air ventilated room, and installed so
that the orientation is exactly as shown in Figure 3. Install to provide water drainage of generator to protect electrical
components.
• Mount the Solar Eclipse so that it is inaccessible to anyone in the pool. Never attempt any servicing while unit is wet.
• Warning - Short-term inhalation of high concentrations of ozone and long term inhalation of low concentrations of
ozone can cause serious harmful physiological effects. DO NOT inhale ozone gas produced by this device.
• For your safety, do not store or use gasoline, chemicals or other flammable liquids or vapors near this or any
other appliance.
• To maintain cosmetic integrity, protect this unit from direct prolonged sunlight exposure.
• ENVIRONMENTAL NOTICE - Hg-Lamp CONTAINS MERCURY. Manage in accordance with disposal laws.
See: www.lamprecycle.org
SAVE THESE INSTRUCTIONS!

Solar Eclipse Installation & Operations Manual
TABLE OF CONTENTS
SECTION 1 General Information
1A. Description ...............................................................1
1B. Specifications...........................................................1
1C. Warranty Summary ..................................................1
SECTION 2 Installation
2A. Pool Prep .................................................................1
2B. Location....................................................................1
2C. Mounting ..................................................................2
2D. Electrical ..................................................................2
2E. Plumbing ..................................................................2
SECTION 3 Operation
3A. Initial System Start-Up .............................................3
3B. Normal Operation.....................................................3
3C. System Shut-Down ..................................................3
3D. Winterizing ...............................................................3
3E. Water Chemistry ......................................................3
SECTION 4 Maintenance & Service
4A. System Electromechanical Overview...................... 3
4B. System Maintenance .............................................. 4
4C. Ozone Module Servicing......................................... 4
4D. UV Reactor Service & Maintenance ....................... 5
SECTION 5 Trouble Shooting .........................6
SECTION 6 Contact Information
6A. Contact Information................................................. 7
6B. Ordering Information ............................................... 7
6C. Standard Replacement Parts List ........................... 7
Warranty ........................................................................ 8

LAMP ACCESS
PANEL
INLET
OUTLET
INDICATOR
LIGHTS
WARNING
LABELS
GROUNDING
LUG
KNOCKOUTS
(1/2” CONDUIT)
FUSE MOUNTING FEET
KNOCKOUTS
(1/2” CONDUIT)
Figure 1: Overview
Figure 2: Wall Mounting Hole Pattern
1
Solar Eclipse Installation & Operations Manual
SECTION 1 General Information
1A. Description
The Solar Eclipse Ozone and UV Sanitation
System described in this manual is designed to
provide the benefits of ozonated and UV treated
water in an environmentally safe and effective
manner. The high quality, specially engineered
components ensure efficient water sanitation output
and reliable performance. As a result of proper use,
the Solar Eclipse virtually eliminates the unpleasant
effects of traditional chemicals. The Solar Eclipse
ozone generators are safe and harmless to your
equipment when installed properly.
1B. Specifications
Power Requirements:
240V, 60 Hz, 1Ø, 0.06 Amp
Shipping Weight:
Approx. 41 lbs / 18.6 kg
Location Requirements:
Mounting: Floor Mounted
Ambient Temp.: 30°F - 120°F (0°C - 50°C)
1C. Warranty Summary
Limited Warranty:
Two year limited warranty. See last page for details.
SECTION 2 Installation
2A. Pool Preparation
To achieve optimal performance from the ozone
system, the pool must be as clean as possible to
start with.
1. Backwash or clean filters one day before
starting the ozone generator.
2. Superchlorinate pool water using a chlorine
based shock treatment prior to ozone system
start-up.
3. Test pool chemistry and adjust pH between 7.4
and 7.6. Adjust total alkalinity between 80 and
120 ppm.
4. Run pool filtration continuously for 24 hours
prior to starting ozone system.
2B. Location
The Solar Eclipse unit is designed for floor
mounting. Locate the unit in a clean, protected
area, either indoors or outdoors (preferably out
of direct sunlight). If possible, locate the unit out
of reach of sprinklers or drainage spouts. Allow
sufficient access for maintenance (2 ft clearance
above and 1 ft around the unit) and all plumbing
and electrical hookups.

Figure 3: Solar Eclipse Location in Pool Loop
SOLAR
ECLIPSE
REAR FITTING
WATER OUT
FRONT FITTING
WATER IN
WATER BACKFLOW CHECK
VALVE (OPTIONAL)
HEATER FILTER PUMP
2
Solar Eclipse Installation & Operations Manual
2C. Mounting
2C-1. Floor Mounting
The Solar Eclipse is shipped with the Mounting
Feet installed in the floor mounting position. Adjust
the position of the feet if necessary and tighten the
screws. Mount the Solar Eclipse to the equipment
pad through the slots provided in the feet using
appropriate hardware for the mounting surface.
2C-2. Wall Mounting
The Solar Eclipse unit does not have holes for wall
mounting but can be mounted on the wall if desired.
1. Drill holes in the back of the enclosure
approximately as shown in Figure 2.
2. Remove Cover with a #2 Phillips driver and
clean out debris.
3. Install Mounting Feet in drilled holes with
hardware provided.
4. Mount unit to wall through the slots provided
in the Feet using appropriate hardware for the
mounting surface.
2D. Electrical
2D-1. Main Power
Connect the Solar Eclipse to the pool timing clock
so that the Solar Eclipse operates simultaneously
with the pool pump. The Solar Eclipse has four
available Knockouts for a 1/2” conduit fitting, two
on the back and one on each side. Remove only
the ideal Knockout for the installation and install
the proper conduit fitting. Remove the Cover (Refer
to Section 4C-1) and locate the Terminal Block
(Refer to Figure 5) on the left side of the enclosure.
Connect Line 1, Line 2, and Ground to the Terminal
Block as indicated by the label on the Generator
Bracket. Refer to the IMPORTANT SAFETY
INSTRUCTIONS at the beginning of this manual for
important wiring information.
2D-2. Grounding Lug
Using a solid copper conductor, connect to the
Grounding Lug on the left side of the Solar Eclipse
to an appropriate earth contact.
2E. Plumbing
The Solar Eclipse can easily be added into the
pool’s plumbing loop. All the components are
contained inside the enclosure so only the water
inlet and outlet need to be installed into the pool’s
return line.
2E-1. Plumbing the Solar Eclipse
The Solar Eclipse must be installed in the pool’s
main return line after all other pool equipment
(pump, filter, heater, and cleaner). Figure 3 shows
the most basic installation. For installation with
additional sanitizers and pool cleaners contact DEL
Technical Support (see Section 6A).
The Solar Eclipse will come with one half of a union
fitting installed on Inlet and Outlet, the other half of
the fittings will be located in the Solar Eclipse parts
bag. Use the union fittings provided to connect
the Solar Eclipse inlet and outlet to your pool’s

3
Solar Eclipse Installation & Operations Manual
plumbing as shown above in Figure 3.
2E-2. Water Backflow Check Valve
If the pool equipment is mounted above the water
line, a check valve must be installed between the
pump outlet and the Injector Manifold to prevent the
pump from draining and losing its prime (when not
in use).
Note: If a 1/3# DELCheckTM is used, do not install
immediately after chlorine feeders.
SECTION 3 Operation
3A. Initial System Start-Up
Upon completing all of the system connections and
cleaning the pool as outlined in Section 2, you are
ready to start the Solar Eclipse.
1. Check electrical connections.
2. Turn on pool circulation system and verify the
Solar Eclipse has power.
3. Remove cover. Confirm that fittings are not
leaking, contact Tech Support (Section 6A) if
leaks are found.
4. Replace cover.
3B. Normal Operation
Indicator Lights: The Solar Eclipse has two
external indicator lights, red and green, on its
left side. When the Solar Eclipse has power, the
green Power Light will illuminate. The red Vacuum
Indicator may be on momentarily. Once adequate
water is flowing and vacuum is established, the
red Vacuum Indicator will go out. If the red Vacuum
Indicator light is still lit after the pump has reached
steady flow, refer to Trouble Shooting (Section 5).
3C. System Shut-Down
The following sequence of steps must be followed
for servicing or for storage.
1. Shut off power at the breaker.
2. Shut off water to the unit.
3. Remove Cover if servicing.
4. Disconnect all electrical, plumbing, and
mounting connections for storage.
3D. Winterizing
If the pool will be shutting down for the winter
months and the Solar Eclipse will remain exposed
to freezing temperatures, the unit must be
drained to prevent freeze damage to the wetted
components. To drain the Solar Eclipse, follow the
steps below.
1. Remove the Cover.
2. Fully loosen the black Union Fitting at the
bottom of the UV Reactor.
3. Gently separate the Injector Manifold from the
UV Reactor to allow the water to drain out of
the drain holes in the bottom of the enclosure.
4. Allow all the water to drain from the Solar
Eclipse before tightening the black union fitting
to reconnect the Injector Manifold to the UV
Reactor. Make sure the union o-ring is properly
seated in its groove before tightening.
3E. Water Chemistry
Regular chlorine testing should be performed as
normal. Ozone will be eliminating the majority of
contaminants. Therefore, only a small amount of
chemicals will need to be added – just enough to
maintain a residual level of 0.5 - 1.0 ppm chlorine.
Ozone is pH neutral and will not cause pH or total
alkalinity fluctuations.
SECTION 4 Maintenance & Service
4A. System Electromechanical Overview
Refer to Figures 4, 5, and 6.
4A-1. Ozone Module
The Solar Eclipse is constructed with 6 Corona
Discharge Ozone Modules. Each Ozone Module
has a green light to indicate that the Ozone Power
Supply is operating properly. (Refer to Figure 5 for
a more detailed view)
4A-2. Ultraviolet Lamps
There are two lamps in the UV Reactor of the Solar
Eclipse. If the UV Lamp Access Panel is removed
while the unit is running, a slight glow can be seen
near the top of the lamps. (Refer to Figure 6 for a
more detailed view)
4A-3. Injector Manifold
Water flowing through the Injector Manifold
generates the vacuum that draws ozone into
the water. The DELCheck™ spring loaded valve
automatically adjusts for various water flow rates to
keep the Solar Eclipse operating over a wide range
of conditions.
4A-4. Ozone Gas Line
Gas from the Ozone Modules is drawn through the
Ozone Gas Line by the Injector and into the water.

OZONE
GENERATOR
ASSEMBLY
OZONE MODULE
BRACKET
POWER
CONNECTOR
TUBE FITTING
OZONE
OUTLET
MANIFOLD
OZONE GAS
LINE & OZONE
CHECK VALVE
UV REACTOR
INJECTOR TUBE
ADAPTER
INJECTOR
MANIFOLD
ORIFICE
TERMINAL
BLOCK
OZONE
MODULE
OZONE
MODULE
LIGHT
MODULE POWER
SUPPLY
FILTER
CAP
DEL CHECK
VALVE
UV LAMPS
BALLAST
Figure 4: Solar Eclipse Electro-Mechanical Overview
Figure 5: Ozone Generator Subassembly
4
Solar Eclipse Installation & Operations Manual
The Ozone Check Valve in this line prevents water
from migrating back to the Ozone Modules when
the Solar Eclipse is not running.
4A-5. Ozone Module Filters and Orifice
The air entering the Ozone Modules passes
through individual Filters and an Orifice on each
Module inlet. The Filters and Orifices are held in
place by the rubber Filter Cap. (Refer to Figure 5
for a more detailed view)
4A-6. Injector Tube Adapter
This connects the Ozone Gas Line to the Injector
Manifold. When servicing this component, do not
tighten past 10 in/lbs or the component may be
damaged.
4B. System Maintenance
All system maintenance must be performed with
either the UV Access Panel or Enclosure Cover
removed. You will need a size 2 phillips head driver
to remove these components
4B-1. Ozone Module Maintenence
The green Ozone Module Lights on the Ozone
Modules indicate that the Ozone Power Supply is
operating properly. When an indicator light goes
out, replace the corresponding Ozone Module.
4B-2. Ozone Module Replacement Interval
Ozone module life expectancy is 5 years. Even if
the Ozone Module Light(s) are glowing, the Ozone
Module may be producing little or no ozone after
this period of time due to contamination within the
corona discharge ozone chamber.
4B-4. Ozone Gasline Replacement Interval
Replace the Ozone Gas Line every year or sooner,
if needed. If there is evidence of water leaking
past the Ozone Check Valve toward the Ozone
Modules, shut down the Solar Eclipse immediately
and replace the Ozone Gas Line. If water entered
the Solar Eclipse, allow the unit to dry completely
before restarting the unit.
WARNING: Trace amounts of nitric acid may be
present in the Ozone Gas Line. Wear proper safety
equipment (gloves and eye protection) and avoid
direct contact with any condensation in the line.
4C. Ozone Module Servicing - Refer to
Figure 5

Figure 6: UV Reactor Subassembly
LAMP CONNECTOR
PLUG
COMPRESSION NUT
COMPRESSION
WASHERS
SEALING O-RING
UV LAMP
QUARTZ TUBE
UV REACTOR
LAMP
CUSHION
LAMP
O-RING
5
Solar Eclipse Installation & Operations Manual
4C-1. Removing the Cover
The Solar Eclipse may be serviced without
disconnecting any of the plumbing or wiring. Simply
remove the cover as follows:
1. Shut down the pool system power, verify that
pump is off, then disconnect power to the ozone
generator.
2. Remove the 12 screws that border the edge of
the cover.
3. Carefully lift and pull the cover off of the Solar
Eclipse.
4. The Base will remain firmly mounted with all the
components fully accessible for servicing.
4C-2. Replacing an Ozone Module
1. Open the Solar Eclipse as described in Section
4C-1.
2. Locate the Ozone Modules on the left wall of
the enclosure.
3. Remove the Filter Cap Assembly from the right
tube fitting of the Ozone Module. Make sure
you keep the Cap, Filter and Orifice together.
4. While holding the Ozone Outlet Manifold, gently
pull the left tube fitting out of the manifold
and both tube fittings through the holes in the
Ozone Module Bracket. Let the Module hang
down.
5. Locate the Power Connector (black and red
wires) from the Module Power Supply and
disconnect from the wire harness.
6. Unscrew the Ozone Module from the Module
Bracket and remove the Module assembly from
the unit.
7. Install the new Ozone Module by reversing the
above steps.
4D. UV Reactor Service and Maintenance
The UV Lamps are housed in a Quartz Tube. If the
Quartz Tube becomes dirty, its ability to transmit UV
rays from the Lamp will be diminished. The Quartz
Tube(s) should be removed from the UV Reactor
every six (6) months and cleaned if necessary.
4D-1 Lamp Removal
1. Open the Solar Eclipse as described in Section
4C-1.
2. Once the pump is turned OFF, verify that the
filter’s pressure gauge located on the filter is
indicating ZERO pressure in the circulation
system. Do not go to the next step until the
pressure gauge shows ZERO. If the pressure
does not recede, simply unscrew the Top Union
nut 1-2 turns.
Note: If your Solar Eclipse is installed below
water level, the bypass valves must all be
CLOSED to prevent water from draining into
the open unit when a Quartz Tube is removed.
3. Allow the UV Lamp to cool before handling.
Unplug the Lamp Connector Plug attached to
the top of the lamps.
4. Slowly pull the UV Lamp out of the Quartz
Tube by the white ceramic prong end. DO NOT
TOUCH THE UV LAMP GLASS WITH YOUR
BARE HANDS. Oils on your hands can cause
hot spots on the Lamp and shorten its life. Use
a soft clean cotton cloth or clean cotton gloves
to handle the UV Lamp. Note that there are two
Lamp O-Rings near the top of the UV Lamp,
and a black Lamp Cushion on the bottom.
Leaving the Lamp Cushion and Lamp O-Rings
on the lamp, carefully place the removed UV
Lamp in a clean, dry and safe location. Repeat
this process for the other UV Lamp.
4D-2 Quartz Tube Removal and Cleaning
1. Remove the plastic Compression Nut along
with the Sealing Ring.
2. Inspect the Sealing Ring for nicks or hardness
and the Compression Washers for cracks and
replace if necessary.
3. DO NOT HANDLE THE QUARTZ TUBE UNTIL
IT COOLS. Grasp the inside of the Quartz Tube
and pull straight up to remove it.
4. Clean the Quartz Tube exterior with a mild
solution of muriatic acid (available at all pool
supply stores) and water in a ratio of four parts
water to one part acid (4:1).

6
Solar Eclipse Installation & Operations Manual
CAUTION: Follow the directions for use and
handling of muriatic acid on the acid bottle
label, being careful to protect your eyes, wear
rubber gloves, and avoid breathing acid fumes.
NOTE: DO NOT USE ABRASIVE CLEANERS
as they can scratch the high quality quartz
glass. If lime or hardwater calcium deposits are
encountered, use household tub and shower
lime removal.
5. After cleaning the Quartz Tube, wash it off and
wipe dry. Inspect the Quartz Tube for cracks.
Replace if cracks are found.
6. Make sure the inside of the Quartz Tube is dry
before replacing the UV Lamp(s).
Note: DAMAGES CAUSED BY BROKEN
QUARTZ TUBES ARE NOT COVERED
UNDER YOUR LIMITED WARRANTY.
4D-3 Quartz Tube Installation
1. Place the Sealing Ring on the Quartz Tube 3/8
in. (9.5 mm) from the open end.
2. Insert the Quartz Tube into the UV Reactor
carefully until it seats in the bottom of the UV
Reactor.
Note: The Quartz Tube will rest on a spring
in the bottom of the UV Reactor. Gently press
the Quartz Tube downward and feel for the
spring to push back to confirm that it is properly
seated.
3. Place the Compression Washers on the Quartz
Tube so they sit on the Sealing Quad Ring.
4. Screw the Compression Nut into the threads till
it is finger tight. DO NOT OVERTIGHTEN.
5. Turn the circulation pump ON and check the
Quartz Tube seal for leaks.
6. Correct any leak found by carefully tightening
the Compression Nut one turn. If the leak
persists, remove the Compression Nut,
Compression Washers and the Sealing
Ring. Inspect all components and replace if
necessary.
7. Re-install the Sealing Ring, Compression
Washers, and Compression Nut and check the
unit for leaks again.
8. Turn the circulation pump OFF once you have
confirmed that the Quartz Tube is not leaking.
4D-4 Re-installing the UV Lamp(s)
Make sure to handle the lamp as described in
section 4D-1.
1. TURN OFF YOUR PUMP IF YOU HAVE NOT
DONE SO.
2. Slowly lower the UV Lamp down into the Quartz
Tube until it is seated in the bottom of the tube.
3. Connect the Lamp Connector Plug to the pins
on the lamp.
NOTE: Do not force the Lamp Connector Plug
onto the pins. If force is needed, it means that
the components are misaligned.
NOTE: To replace a UV Lamp, follow only
Sections 4D-1 and 4D-4
ENVIRONMENTAL NOTICE - Hg-Lamp
CONTAINS MERCURY. Manage in accordance
with disposal laws. See: www.lamprecycle.org
SECTION 5 Trouble Shooting
Knowledge of electrical applications is required
for trouble shooting. Contact a certified electrician
if you are unsure of your ability to service the
equipment. Improper servicing will void generator
warranty. If any condition persists contact DEL
Technical Support (see Section 6A).
Symptom: Green Indicator not lit when pool
system is on.
1. No power to the Solar Eclipse from the Power
Source:
a. Check circuit breaker at the power
distribution box.
b. Check for loose connections or wiring
breaks in the lines leading to the Terminal
Block.
c. Fuse in the unit has blown and needs to be
replaced. Fuse is an AGC-1 (1 amp ,1/4” x
1.25” long, glass fuse).
d. Indicator lights have burnt out.
Symptom: Red Indicator will not go out.
1. Insufficient flow through Solar Eclipse.
a. Verify that pump is running properly and
that filter and skimmers are clean.
b. Clear any blockages in return line.
Symptom: Green Ozone Module Light is not
illuminated when unit is running.
1. This means that the power supply of that
specific ozone module is no longer drawing
power and needs to be replaced. Refer to
Section 4C-2 for instructions on how to replace
the corresponding ozone module.

7
Solar Eclipse Installation & Operations Manual
Symptom: One or both the UV Lamps are not lit
when unit it running.
1. Check Lamp Connector Plug for complete
connection.
2. Water fouling has shorted lamp connections.
3. Bad UV Lamp.
4. Bad Ballast.
SECTION 6 Contact Information
6A. Contact Information:
For technical assistance:
Call: (805) 541-1601 ext. 293 or (800) 676-1335
ext. 293
Email: [email protected]
Or visit our website: www.delozone.com
Be prepared with the following information:
• Name
• Address
• DELModel#
• DatePurchased
6B. Ordering Information:
To locate a dealer nearest you call 1.800.676.1335,
ext. 232 or visit www.delozone.com.
6C. Standard Replacement Parts List:
1. UV Lamps (18 months)
2. Ozone Gas Line (1 year)
3. Sealing Ring (Inspect part during Quartz Tube
maintenence, replace if cracked or brittle)
4. UV Reactor Union O-ring (Inspect part during
Quartz Tube maintenence, replace if cracked or
brittle)
Note: The warranty is void if the parts listed above
are not replaced at recommended intervals.

8
Solar Eclipse Installation & Operations Manual
DEL OZONE Solar Eclipse™
LIMITED WARRANTY
The limited warranty set forth below applies to products manufactured by DEL OZONE – 3580 Sueldo Street, San Luis
Obispo, California 93401, and sold by DEL OZONE or its authorized dealers. This limited warranty is given only to the first
retail purchaser of such products and is not transferable to any subsequent owners or purchasers of such products.
DEL Ozone warrants that it or its authorized dealers will repair or replace, at its option, any part of such products proven
to be defective in materials or workmanship within:
Two (2) years from the date of retail purchase of such products, all parts except:
Eighteen (18) months on UV Lamps
Twelve (12) months on Ozone Gas Line and Ozone Check Valve assembly
ANY REPAIR OR REPLACEMENT WILL BE WARRANTED ONLY FOR THE BALANCE OF THE ORIGINAL
WARRANTY PERIOD.
NOTE: USE ONLY DEL AUTHORIZED DEL REPLACEMENT PARTS. USE OF ANY OTHER PART(S) WILL VOID
THIS WARRANTY.
Any replaced parts must be returned to DEL OZONE for warranty evaluation.
THIS LIMITED WARRANTY DOES NOT INCLUDE ANY OF THE FOLLOWING:
(a) Any repair or replacement of such parts necessitated by faulty installation, improper maintenance, improper
operation, misuse, abuse, negligence, accident, fire, flood, repair materials, and/or unauthorized accessories.
(b) Any such products installed without regard to required local codes and accepted trade practices.
(c) Damage to unit caused by water backflow;
(d) Any implied warranty of merchantability or implied warranty of fitness for particular purpose, and such
warranties are hereby disclaimed.
(e) DEL Ozone shall not be liable under any circumstances for loss of use of such product, loss of profits. direct
damages, indirect damages, consequential damages, and / or incidental damages.
This warranty gives you specific legal rights. You may have other rights which vary from state to state.
TO OBTAIN WARRANTY SERVICE:
DEL OZONE
3580 Sueldo, San Luis Obispo, CA 93401
Customer Service Number: (800) 676-1335 x 293
Fax Number: (805) 597-5452
PROVIDE:
1. Customer name, mailing address, and telephone.
2. Installer/Mechanical Contractor or Dealer name.
3. Unit Part Number, Serial Number or Manufacture Date, and date of purchase.
4. The date of failure.
5. A description of the failure.
After this information is provided, DEL Ozone may release a RETURN GOODS AUTHORIZATION (RGA) NUMBER. After receiving the RGA number
the part in question must be returned to DEL Ozone, freight prepaid, with the RGA number clearly marked on the outside of the package. All
preauthorized defective parts must be returned to DEL Ozone within thirty (30) days. Under no circumstances may any product be returned to DEL
Ozone without prior authorization. Returns without the assigned RGA number on the outside of the package will be refused and shipped back to the
sender at their expense. Upon receipt of preauthorized returned goods, DEL Ozone will repair or replace, at DEL Ozone’s option, the defective product(s)
and return them (freight prepaid for products under warranty). Buyer’s acceptance of the product and use thereof constitutes acceptance of these terms.
4-2006-01_Rev.A

3580 Sueldo Street, San Luis Obispo, CA 93401 | 800.676.1335 | o3info@delozone.com | www.delozone.com
EPA Estab. No. 071472-CA-001