Delfield 204 User manual

200 & 300 SERIES
Service and Installation Manual
Please read this manual completely before attempting to install or operate this equipment!
Notify carrier of damage! Inspect all components immediately. See page 2.
Drop In and Undercounter Products
Effective APRIL 2003
IMPORTANT INFORMATION
READ BEFORE USE
PLEASE SAVE THESE INSTRUCTIONS!
CAUTION

200 and 300 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
2
The serial number on all Model 225 and 227 units is located
on the tag affixed next to the temperature control, inside the
compressor stand at the bottom of the unit.
Always have the serial number of your unit available when call-
ing for parts or service.
©2003 The Delfield Company. All rights reserved. Reproduction without
written permission is prohibited. “Delfield” is a registered trademarks of
The Delfield Company.
CONTENTS
SERIAL NUMBER INFORMATION
SPECIFICATIONS
RECEIVING AND INSPECTING THE EQUIPMENT
RECEIVING & INSPECTING EQUIPMENT..................................2
SPECIFICATIONS........................................................................2
INSTALLATION ..........................................................................3
OPERATION................................................................................4
MAINTENANCE ..........................................................................4
WIRING DIAGRAM.....................................................................8
STANDARD LABOR GUIDELINES..............................................9
REPLACEMENT PARTS LIST..................................................5-8
STANDARD WARRANTY.....................................................10-11
PARTS DEPOTS ........................................................BACK PAGE
Even though most equipment is shipped packaged, care
should be taken during unloading so the equipment is not
damaged while being moved into the building.
1. Visually inspect the exterior of the package and skid or
container. Any damage should be noted and reported to
the delivering carrier immediately.
2. If damaged, open and inspect the contents with the
carrier.
3. In the event that the exterior is not damaged, yet upon
opening, there is concealed damage to the equipment
notify the carrier. Notification should be made verbally
as well as in written form.
4. Request an inspection by the shipping company of the
damaged equipment. This should be done within 10
days from receipt of the equipment.
5. Visually inspect the refrigeration package. Be sure lines
are secure and base is still intact.
6. Freight carriers can supply the necessary damage forms
upon request.
7. Retain all crating material until an inspection has been
made or waived.
MODEL OVERALL CUTOUT CABINET DESIGN SYSTEM
NUMBER L D H SIZE CAPACITY H.P. AMP LOAD BTU CAP. BTU
DROP-IN FREEZERS
N225
16.56” 27.87” 26.75” 25.75” x 14.62” 6 gal. 1/5 5.0 292 569
N227
30” 27.87” 26.75” 25.75” x 28.00” 12 gal. 1/5 5.0 473 661
DROP-IN FREEZERS WITH LEXAN®LID
225L
16.56” 27.87” 26.75” 25.75” x 14.62” 6 gal. 1/5 5.0 292 569
227L
30” 27.87” 26.75” 25.75” x 28.00” 12 gal. 1/5 5.0 473 661
MODEL OVERALL CUTOUT ICE
NUMBER DESCRIPTION L D H SIZE CAPACITY
DROP-IN WATER STATIONS AND ICE STORAGE
203
ice chest 20.25” 20.25” 23.25” 19.25” x 19.25” 90 lbs.
204
water and ice station 24” 21” 23.5” 21” x 17.75” 45 lbs.
240
ice chest with cover 21” 17.5” 17” — 75 lbs.
248
water and ice station 31” 15” 22.5” 28” x 12.5” 45 lbs.
305
ice chest with cover 21.25” 15.25” 13” 17.75” x 13.25” 45 lbs.
307
glass filler 12” 12” 9.5” — —
UNDERCOUNTER SINKS, WATER STATIONS AND ICE STORAGE
242
UC sink & faucet 18” 13.5” 12.75” 17” x 12.5” —
250
UC sink, ice chest 46” 14.12” 22.75” 45” x 13” 45 lbs.
and water station

200 and 300 Series Service and Installation Manual
3
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
INSTALLATION
Location
The refrigeration system has been factory tested
and should require no further adjustment during
installation.
For the most efficient refrigeration, be sure to provide
good air circulation inside and out.
Outside Cabinet: Be sure that the unit has access
to ample air. Avoid hot corners and locations near
stoves and ovens.
Counter Cutouts
For installation provide a cutout in the counter as
shown (see illustration 1 or 2). The counter must be
sturdy enough to hold the combined weight up to 300
lbs. of the drop-in and the product stored inside.
The louver provided must be installed
in front of the condensing unit’s finned
coil (see illustration 3). A second
cutout must be made at the rear or
end of the equipment to allow air flow
through the unit. No louver is provided
for the second cutout. Any restriction
to the proper air flow, total or partial,
will void the compressor warranty.
225 or 227 DROP-IN
TYPICAL
COUNTER
CABINET
LOUVER
13.00" x 24.37"
33.0cm x 61.9cm
LOUVER CUTOUT SIZE
11.50" x 23.00"
29.2cm x 58.4cm
(typical installation)
NOTE: A second cutout
(without louver) must
also be made to allow
proper air flow.
25.75"
65.4cm
28.0"
71.1cm
CUTOUT
.75"/1.9cm radius
1.00"/2.5cm (min.)
1.00"/2.5cm (min.)
COUNTERTOP
25.75"
65.4cm
14.62"
37.1cm
CUTOUT
.75"/1.9cm
radius
1.00"/2.5cm (min.)
1.00"/2.5cm (min.)
COUNTERTOP
Illustration 1. Model 225 cutout dimensions
Illustration 2. Model 227 cutout dimensions
Illustration 3. Models 225 & 227 louver installation
Electrical Connection
Refer to the amperage data on page 2, the serial tag,
your local code or the National Electrical Code to be
sure the unit is connected to the proper power source.
A protected circuit of the correct voltage and amperage
must be run for connection of the line cord.
If the unit does not operate after it is plugged in, check
the thermostat to see if it was inadvertently turned
OFF during installation.
The unit must be disconnected from
the power source whenever performing
service or maintenance functions.

200 and 300 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
4
OPERATION MODELS 225 AND 227
After installation, the unit will begin operating simply
by plugging it into the proper outlet. If the unit does
not operate after being plugged in, check to see if the
thermostat is in the OFF position.
The models 225 and 227 are designed to
hold ice cream or other frozen products at a
temperature range of 5°F to -5°F (-15°C to -
21°C). The thermostat is located in the machine
compartment.
MAINTENANCE MODELS 225 AND 227
In order to maintain proper refrigeration performance,
the condenser fins must be cleaned of dust, dirt, and
grease every three months. If conditions are such
that the condenser is totally blocked in three months,
the frequency of cleaning should be increased.
Clean the condenser with a vacuum cleaner or stiff
brush. If extremely dirty, a commercially available
condenser cleaner may be required.
Defrosting must be done manually after 3/8” of ice
accumulation.
The lid should be cleaned regularly with a soft
cloth or sponge and solution of soap and water to
maintain their ability to seal properly.
MAINTENANCE - MODELS 203, 204, 240, 242, 248, 250, 305 & 307
The interior and exterior of these models may be
cleaned using soap and warm water. If this is not
sufficient, try ammonia and water or a non-abrasive
cleaner. Be sure to rinse thoroughly with clean water
after using ammonia or a cleaner. When cleaning the
exterior, always rub with the “grain” of the stainless
steel to avoid marring the finish.
Do not use an abrasive cleaner. Abrasive
cleaners will scratch the stainless steel
and plastic.

200 and 300 Series Service and Installation Manual
5
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
PARTS LIST AND ILLUSTRATION - MODEL 225/227
1
2
13
12
11 10
9
8
7
6
5
3
4
1 3234188 Cover (solid)*
3234189 Cover (see-through)*
2 1701022 Trim gasket
3 3526996 227 Compressor, 1/4 H.P. (404A)
3526997 225 Compressor, 1/4 H.P. (404A)
4 2183349 Harness, power cord
5 3516047 Temperature control
6 3977986 Wire fan guard
7 GMK00203 Access cover
8 GMK000208 Comp. stand
9 AMK00021 Fan motor bracket
10 2162691 Fan motor
11 3516172 Fan blade
12 GMK00207 Fan baffle
13 3516067 Condensing coil
Purchase locally Capillary tube, .031” i.d. 120”
MK900086 Lid lock device 225 standard cover
MV800013 Lid lock device 227 standard cover
*Locking device for the cover is optional; the locking
device for the solid and see-through covers are
different.

200 and 300 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
6
PARTS LIST AND CUTOUT DIMENSIONS -
MODEL 203 (0762400)
PARTS LIST AND CUTOUT DIMENSIONS -
MODEL 204 (0762700)
Removable lid 00360015
Lid handle 3234110
Cutout dimensions: 19.25” x 19.25” (48.9cm x 48.9cm)
Glass filler 3234088
Drain 3234242
Grate 3978047
Removable lid 0360015
Lid handle 3234110
Cutout dimension: 21.00” x 17.75” (53.3cm x 45.1cm)
PARTS LIST AND CUTOUT DIMENSIONS -
MODEL 242 (0761600)
PARTS LIST AND CUTOUT DIMENSIONS -
MODEL 250 (0762000)
Basket Strainer 3234007
Faucet 3234076
Cutout dimensions: 17.00” x 12.50” (40.6cm x 31.8cm)
Basket strainer 3234007
Faucet 3234076
Glass filler 3234088
Drain 3234242
Grate 3978047
Removable lid 0360015
Lid handle 3234110
Cutout dimension: 45.00” x 13.00” (114.3cm x 33.0cm)
PARTS LIST AND CUTOUT DIMENSIONS -
MODEL 248 (0764900)
Glass filler 3234088
Drain 3234242
Grate 3978047
Removable lid 0360015
Lid handle 3234110
Cutout dimension:
30.00” x 13.25”
(76.2cm x 33.7cm)

200 and 300 Series Service and Installation Manual
7
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
PARTS LIST AND CUTOUT DIMENSIONS -
MODEL 305 (0764000)
PARTS LIST AND CUTOUT DIMENSIONS -
MODEL 307 (0763300)
Drain 3234242
Removable lid 0360015
Lid handle 3234110
Cutout dimensions: 17.75” x 13.25” (45.1cm x 33.7cm)
Glass filler 3234088
Grate 3978047
Cutout dimension: 8.00” (20.3cm) diameter plus
four .37” dia. (1.0cm) diameter
holes arranged in a square 10.12”
(25.7cm) on each side.
GND
CONTROL
POWER
SUPPLY
115V/60 Hz/1Ø
WHITE
GREEN
BLACK COMPRESSOR
CONDENSER
FAN
WIRING DIAGRAM MODELS 225 AND 227

200 and 300 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
8
STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT
Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.
• A maximum of 1-hour is allowed to diagnose a defective component.
• A maximum of 1-hour is allowed for retrieval of parts not in stock.
• A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
• Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or
correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work
Authorization from Delfield. You must submit the number with the service claim.
LABOR OF 1-HOUR IS ALLOWED TO REPLACE:
• Thermostat • Contactor/Relay
• Infinite Switch • Transformer
• Door Jamb Switch • Evaporator/Condenser Fan Motor and Blade
• Solenoid Coil • Circulating Fan Motor and Blade
• Hi-limit/Thermal Protector Switch • Microprocessor Control
• Fan Delay/Defrost Termination Switch • Water Level Sensor/Probe
• Compressor Start Components and Overload Protector • Door Hinges, Locks, and Gaskets
• Defrost Timer • Condensate Element
• Thermometer • Springs/Lowerator
• Gear Box
LABOR OF 2 HOURS TO REPLACE:
• Drawer Tracks/Cartridges • Defrost Element
• Pressure Control • Heating Element
• Solenoid Valve • Locate/Repair Leak
LABOR OF 3 HOURS TO REPLACE:
• EPR or CPR Valve • Condenser or Evaporator Coil
• Expansion Valve
LABOR OF 4 HOURS TO REPLACE
• Compressor
This includes recovery of refrigerant and leak check.
$35.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings,
solder, brazing rod, nitrogen, or similar fees.)
REFRIGERANTS
• R22 A maximum of $4.00/lb. or 25¢/oz. will be reimbursed.
• R134A A maximum of $5.00/lb. or 31¢/oz. will be reimbursed.
• R404A A maximum of $12.00/lb. or 75¢/oz. will be reimbursed.

200 and 300 Series Service and Installation Manual
9
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
STANDARD ONE YEAR WARRANTY(One year parts, 90 days labor.)
The Delfield Company (“Delfield”) warrants to the Original Purchaser
of the Delfield product (herein called the “Unit”) that such Unit, and all
parts thereof, will be free from defects in material and workmanship
under normal use and service for a period of one (1) year from
the date of shipment of the Unit to the Original Purchaser or, if the
Original Purchaser returns the warranty card completely filled out
including the date of installation within thirty (30) days of receipt
of the Unit, one (1) year from the date of installation. During this
one year warranty period, Delfield will repair or replace any defective
part or portion there of returned to Delfield by the Original Purchaser
which Delfield determines was defective due to faulty material or
workmanship. The Original purchaser will pay all labor, crating, freight
and related costs incurred in the removal of the Unit of defective
component and shipment to Delfield, except that during a period of
either ninety (90) days from the date of shipment of the Unit to the
Original Purchaser or, if the Original Purchaser returns the warranty
card completely filled out including the date of installation within thirty
(30) days of receipt of the Unit, ninety (90) days from the date of
installation Delfield will pay all related labor costs. Delfield will pay the
return costs if the Unit or part thereof was defective.
The term “Original Purchaser” as used herein means that person, firm,
association, or corporation for whom the Unit was originally installed.
This warranty does not apply to any Unit or part thereof that has
been subjected to misuse, neglect, alteration, or accident, such as
accidental damage to the exterior finish, operated contrary to the
recommendations specified by Delfield; or repaired or altered by anyone
other than Delfield in any way so as to, in Delfield’s sole judgement,
affect its quality or efficiency. This warranty does not apply to any Unit
that has been moved from the location where it was originally installed.
This warranty also does not cover the refrigerator drier or the light
bulbs used in the Unit. The warranty is subject to the user’s normal
maintenance and care responsibility as set forth in the Service and
Installation Manual, such as cleaning the condenser coil, and is in
lieu of all other obligations of Delfield. Delfield neither assumes, nor
authorizes any other person to assume for Delfield, any other liability
in connection with Delfield’s products.
Removal or defacement of the original Serial Number or Model Number
from any Unit shall be deemed to release Delfield from all obligations
hereunder or any other obligations, express or implied.
Parts furnished by suppliers to Delfield are guaranteed by Delfield only
to the extent of the original manufacturer’s express warranty to Delfield.
Failure of the Original Purchaser to receive such manufacturer’s express
warranty to Delfield. Failure of the Original Purchaser to receive such
manufacturers warranty shall in no way create any warranty, expressed
or implied, or any other obligation or liability on Delfield’s part in respect
thereof.
IF THE CUSTOMER IS USING A PART THAT RESULTS IN A VOIDED
WARRANTY AND A DELFIELD AUTHORIZED REPRESENTATIVE
TRAVELS TO THE INSTALLATION ADDRESS TO PERFORM WARRANTY
SERVICE, THE SERVICE REPRESENTATIVE WILL ADVISE CUSTOMER
THE WARRANTY IS VOID. SUCH SERVICE CALLS WILL BE BILLED
TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER’S THEN
APPLICABLE TIME AND MATERIALS RATES. CONSIDER: CUSTOMER
MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE.
If shipment of a replacement part is requested prior to the arrival in
the Delfield factory of the part claimed to be defective, the Original
Purchaser must accept delivery of the replacement part of a C.O.D.
basis, with credit being issued after the part has been received and
inspected at Delfield’s plant and determined by Delfield to be within
this warranty.
Under no condition does this warranty give the Original Purchaser the
right to replace the defective Unit with a complete Unit of the same
manufacturer or of another make. Unless authorized by Delfield in
writing, this warranty does not permit the replacement of any part,
including the motor-compressor, to be made with the part of another
make or manufacturer.
No claims can be made under this warranty for spoilage of any
products for any reason, including system failure.
The installation contractor shall be responsible for building access,
entrance and field conditions to insure sufficient clearance to allow
any hood(s), vent(s), or Unit(s) if necessary, to be brought into the
building. Delfield will not be responsible for structural changes
or damages incurred during installation of the Unit or any exhaust
system.
Delfield shall not be liable in any manner for any default or delay in
performance hereunder caused by or resulting from any contingency
beyond Delfield’s control, including, but not limited to, war,
governmental restrictions or restraints, strike, lockouts, injunctions,
fire, flood, acts of nature, short or reduced supply of raw materials, or
discontinuance of the parts by the original part manufacturer.
Except as provided in any Additional Four Year Protection Plan,
if applicable, and the Service Labor Contract, if applicable, the
foregoing is exclusive and in lieu of all other warranties, whether
written or oral, express or implied. This warranty supersedes
and excludes any prior oral or written representations or
warranties. Delfield expressly disclaims any implied warranties
of merchantability, fitness for a particular purpose of compliance
with any law, treaty, rule or regulation relating to the discharge of
substances into the environment. The sole and exclusive remedies
of any person relating to the Unit, and the full liability of Delfield
for any breach of this warranty, will be as provided in this warranty.
Other than this Delfield Standard One Year Limited Warranty, any
applicable Delfield Additional Four Year Protection Plan or applicable
Delfield Service Labor Contract, the Original Purchaser agrees and
acknowledges that no other warranties are offered or provided in
connection with or for the unit or any other part thereof.
In no event will Delfield be liable for special, incidental or
consequential damages, or for damages in the nature of penalties.
IF DURING THE WARRANTY PERIOD, CUSTOMER USES A PART
FOR THIS DELFIELD EQUIPMENT OTHER THAN AN UNMODIFIED
NEW OR RECYCLED PART PURCHASED DIRECTLY FROM DELFIELD
OR ANY OF ITS AUTHORIZED SERVICE CENTERS AND/OR THE PART
BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION,
THIS WARRANTY WILL BE VOID. FURTHER, DELFIELD AND ITS
AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS DAMAGES
OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE
DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE
INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED
FROM AN UNAUTHORIZED SERVICE CENTER. If the warranty
becomes void, Customer may purchase from Delfield, if available,
a Service Agreement or service at the then current time and
materials rate.
For more information on Delfield warranty’s log on and check out the
service section of our web site at www.delfield.com.

200 and 300 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
10
ADDITIONAL FOUR YEAR PROTECTION PLAN (for Motor-Compressor only)
Installation
Delfield Model# Serial # Date
In addition to the Standard One Year Warranty on the Motor-
Compressor contained in the above listed Delfield product (the
“Unit”), The Delfield Company (“Delfield”) also agrees to repair, or
exchange with similar or interchangeable parts in design and capacity
at Delfield’s option, the defective Motor-Compressor contained in the
Unit (the “Motor-Compressor), or any part thereof, for the Original
Purchaser only, at any time during the four (4) years following the
initial one (1) year period commencing on the date of installation for
the Original Purchaser. Failure of the Original Purchaser to register
the registration card containing the Original Purchasers name,
address, date of installation, model number and serial number of
the Unit containing the Motor-Compressor within 30 days from the
date of installation shall void this warranty. This additional warranty
is only available if the Motor-Compressor is inoperative due to defects
in material or factory workmanship, as determined by Delfield in
its sole judgement and discretion. The Original Purchaser shall be
responsible for returning the defective Motor-Compressor to Delfield
prepaid, F.O.B. at the address shown on the back cover of this manual.
The term “Original Purchaser” as used herein means that person, firm,
association, or corporation for whom the Unit was originally installed.
The term “Motor-Compressor” as used herein does not include unit
base, air or water cooled condenser, receiver, electrical accessories
such as relay, capacitors, refrigerant controls, or condenser fan/motor
assembly. This warranty does not cover labor charges incidental to
the replacement of parts. This warranty further does not include
any equipment to which said condensing unit is connected, such as
cooling coils, temperature controls or refrigerant metering devices.
This warranty shall be void if the Motor-Compressor, in Delfield’s
sole judgement, has been subjected to misuse, neglect, alteration
or accident, operated contrary to the recommendations specified
by the Unit manufacturer, repaired or altered by anyone other than
Delfield in any way so as, in Delfield’s sole judgment, to affect its
quality or efficiency or if the serial number has been altered, defaced
or removed. This Warranty does not apply to a Motor-Compressor in
any Unit that has been moved from the location where it was originally
installed. The addition of methyl chloride to the condensing unit or
refrigeration system shall void this warranty.
General Conditions
Delfield shall not be liable in any manner for any default or delay
in performance hereunder caused by or resulting from any
contingency beyond Delfield’s control, including, but not limited
to, war, governmental restrictions or restraints, strike, lockouts,
injunctions, fire, flood, acts of nature, short or reduced supply
of raw materials, or discontinuance of any part or the Motor-
Compressor by the unit manufacturer.
Replacement of a defective Motor-Compressor is limited to one (1)
Motor-Compressor by us during the four (4) year period. Delfield
shall replace the Motor-Compressor at no charge.
This warranty does not give the Original Purchaser of the Motor-
Compressor the right to purchase a complete replacement Motor-
Compressor of the same make or of another make. It further does
not permit the replacement to be made with a Motor-Compressor
of another kind unless authorized by Delfield. In the event Delfield
authorizes the Original Purchaser to purchase a replacement
Motor-Compressor locally, only the wholesale cost of the Motor-
Compressor is refundable.
Expressly excluded from this warranty are damages resulting from
spoilage of goods.
Except as provided in any applicable Standard One Year Limited
Warranty or applicable Service Labor Contract, the foregoing
is exclusive and in lieu of all other warranties, whether written
or oral, express or implied. This Warranty supersedes and
excludes any prior oral or written representations or warranties.
Delfield expressly disclaims any implied warranties of
merchantability, fitness for a particular purpose or compliance
with any law, treaty, rule or regulation relating to the Motor-
Compressor, and the full liability of Delfield for any breach of this
warranty, will be as provided in this warranty.
Other than any applicable Delfield Standard One year Limited
Warranty, this Delfield Additional Four Year Protection Plan and any
applicable Delfield Service Labor Contract, the Original Purchaser
agrees and acknowledges that no other warranties are offered or
provided in connection with or for the Motor-Compressor or any
part thereof.
In no event will Delfield be liable for special, incidental or
consequential damages, or for damages in the nature of penalties.

200 and 300 Series Service and Installation Manual
11
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
NOTES:

DM200_300 07/06
980 S. Isabella Rd., Mt. Pleasant, MI 48804-0470, U.S.A. • (989) 773-7981 or (800) 733-8821 • Fax (800) 669-0619 • www.delfield.com
Delfield reserves the right to make changes in design or specifications without prior notice. 2003 The Delfield Company. All rights reserved. Printed in the U.S.A.
1336 Main Street
Buffalo, NY 14209
800.722.1252
716.884.7425
716. 884.0410 FAX
serves: CT, DC, DE, MA, MD, ME,
NH, NJ, NY, PA, RI, VA, VT, WV
3) Appliance Installation Service
15024 Staff Court
Gardena, CA 90248
1.800.531.1111
1.800.782.5747
Email: [email protected]
www.pacparts.com
serves: AZ, CA, HI, NV, OR
4) Pacific Coast Parts
2916 Sidco Drive
Nashville, TN 37204
615.726.0351
800.737.0351
615.259.4100 FAX
serves: TN, AL
14) T.M.A.
14450 Ewing Ave S. #100
Burnsville, MN 55306
800.422.2823
952.894.4427
952.894.2164 FAX
serves: IA, MN, MT, ND, SD, WI
5) Contract Ice
3909 St. Timothy Lane
St. Ann, MO 63074
800.972.7670
314.427.7477
314. 427.8190 FAX
serves: AR, IA, IL, KS,
KY, MO, NE, OK, TX, NM, LA
6) E.M.C.O. Sales & Distributors
2920 N.W. 109th Avenue
Miami, FL 33172
305 994.9994
305.994.9992 FAX
International parts depot
9) Global Parts and Supplies
2120 Solona St.
PO Box 14009
Fort Worth, TX 76117-0009
1.800.433.1804 toll free
1.800.272.7358 fax
serves: AR, LA, NM, OK, TX
7) Stove Parts Supply/GCS Service
9923 S.W. 178th St.
Vashon, WA 98070
888.872.2465
206-463-1772
206.463.4431 FAX
serves: AK, HI, ID, MT, OR, WA
12) Performance Refrigeration Parts
2200 Norcross Parkway, Suite 210
Atlanta, GA 30071
800.235.6516
770.446.6177
770.446.3157 FAX
serves: FL, GA, MS, NC, SC, VA
13) Southeastern Restaurant Services
1816 West 26th Street
Erie, PA 16508-1149
800.332.3732
814.456.3732
814.452.4843 FAX
serves: MD, NJ, OH, PA, VA, WV
2) A.I.S. Commercial Parts & Service
1177 Kamato Road
Mississauga, Ontario L4W1X4
800.427.6668
800.361.7745 FAX
serves: Canada
8) Garland Group
980 South Isabella Road
Mt. Pleasant, MI 48858
800.733.8829
989.773.7981
989.773.3210 FAX
custom parts direct from Delfield
1) The Delfield Company
44792 Helm
Plymouth, MI 48170
888.828.4454
734.451.2043
734.451.3215 FAX
serves: MI, IN, WI, OH
11) MicroDine, Inc.
3000 S. Wyandot
Englewood, CO 80110
(800) 624-2117
(303) 7618861 FAX
serves: AZ, CO, KS, NE, NM, OK, UT, WY
10) Hawkins Commercial Appl. Serv.
NORTH
AMERICA
4
4
12
9
10
1
11
7
6
5
14
3
13
8
2
12
Delfield has 14 conveniently located Parts Depots to
ensure parts are handled promptly and accurately.
Delfield reserves the right to update or make changes
to this list without prior notice
Please call 1-800-733-8829 or check the web at www.delfield.com
for a list of the current Parts Depots.
AUTHORIZED PARTS DEPOTS
Other manuals for 204
2
This manual suits for next models
11
Other Delfield Ice Maker manuals
Popular Ice Maker manuals by other brands

Hoshizaki
Hoshizaki KM-650MAH-E Specifications

GE
GE Monogram Refrigerator Dimensions and installation information

Ice-O-Matic
Ice-O-Matic ICE2106 Series Specification sheet

Costway
Costway ES10127US manual

Whirlpool
Whirlpool GI15NDXTB - 15" 50 lb. Icemaker Dimensional information

Primo Water
Primo Water PR407IB manual