  9. Dell EMC PowerEdge R640 Manual

Dell EMC PowerEdge R640 Manual

Metro node
Hardware Installation Guide
Copyright © 2020 Dell Inc. or its subsidiaries. All Rights Reserved.
Dell P/N: 6Y7M8 Rev. A00
2020 - 12
Before you begin
Review the following documents:
Technical and environmental specifications
– https://topics-cdn.dell.com/pdf/poweredge-r640_reference-guide2_en-us.pdf
Dell EMC Rail Installation Guide
– https://downloads.dell.com/Manuals/all-products/esuprt_ser_stor_net/esuprt_poweredge/
poweredge-r640_Setup-Guide2_en-us.pdf
Dell EMC Cable Management Arm (CMA) Installation Guide
– For detailed information, see the guide available at Dell EMC Online Support
(https://www.dell.com/support).
• Confirm that following are available:
- metro node servers–2
- Cable Management Arm Kit–1
• Verify that the equipment is fully acclimated to the data center environment.
1Install metro node servers
1. Install the servers in the rack referencing the Dell EMC Rail Installation Guide:
a. Remove slide rails from boxes and install in two consecutive 1U locations in target rack.
b. Remove server nodes from boxes and mount them on the installed slide rails.
NOTE: Mount the server with the lower Dell Service Tag (DST) in the upper position.
2. Install one LCD bezel on each server.
3. Save 10 GbE SFP optical transceivers for installation in the next section.
2Install Cable Management Arm Kit
1. Attach the CMA attachment bracket to the server slide rails for each server.
2. Attach the CMA tray to the server slide rails for each server.
3. Attach the pre-wired Cable Management Arm Kit to the server slide rail assembly of each
server nodes.
a. Connect the inner CMA clip (1) to the left inner sliding rail.
b. Connect the outer CMA clip (2) to the left outer fixed rail.
c. Repeat for each server node.
d. Secure the cable loop and red service cable to the side of the rack with Velcro straps.
CAUTION: Ensure that the cable loop is securely supported on the rack and
does not pull on the cables in the management arms.
3Connect CMA kit cables to the Server nodes
The Port Map Label image below shows the port assignment for the following steps:
1. Install WAN SFP modules into the two WAN ports on each node.
a. Insert one 10 GbE SFP module into the port marked WAN1 on the port map.
b. Insert one 10 GbE SFP module into the port marked WAN2 on the port map.
c. To confirm that these are latched securely, pull gently on each of the
SFP I/O modules. If SFP is loose:
1. Release the spring latch.
2. Push the SFP fully in.
3. Close the spring latch.
4. Repeat for each node.
NOTE: For local system configurations: a) Install the WAN SFPs in the WAN port for
safekeeping and/or potential future use, b) Ensure that the cable plugs are in place to
protect the SFP when not in use.
2. Connect the LCOM Direct Attach Copper (DAC) cables to the two LCOM ports on
eachnode.
a. Connect the black cable labeled LCOM1 to the port marked LCOM1 on the port map.
Repeat at each node.
b. Connect the black cable labeled LCOM2 to the port marked LCOM2 on the port map.
Repeat at each node.
c. Verify that cables are seated securely by pulling lightly on the cable at each node
connection.
3. Connect the MGMT Ethernet cables to the two MGMT ports on each node.
a. Connect the green cable labeled MGMT1 to the MGMT1 port as shown on the
portmap. Repeat at each node.
b. Connect the violet cable labeled MGMT2 to the MGMT2 port as shown on the
portmap. Repeat at each node.
c. Verify that the cables are securely latched at each node connection by pulling lightly on
the cable at each node connection.
4. Connect the AC power cables to the power supply units on each node.
a. Connect the black power cable to PSU1/the black ‘AC Power’ block on the port map.
b. Connect the gray power cable to PSU2/the gray ‘AC Power’ block on the port map.
c. Repeat at each node.
d. Verify that the power cable routing allows each server node to move freely on the
sliderails.
CAUTION: Loop the power cable and secure to the PSU handle with the provided
Velcro straps as shown in the following figure. Ensure the strap lifts the power
cable to prevent binding when server is extended during service.
4Connect power cables to redundant utility power sources
Connect the black and the gray power cables to separate utility power feeds.
CAUTION: Redundant power connections are required to maintain HA.
Ensure gray and black cords connect to separate power supplies.
1. Connect the gray power cables to the utility A Power Distribution Unit (PDU).
2. Connect the black power cables to the utility B PDU.
5Check metro node interconnections and power
1. Verify that each node is getting power from BOTH power zones. Verify that the PSU
handle glows solid GREEN for both PSUs in each node.
CAUTION: If the PSU LED is OFF, check the power cable connections.If the
LED is not solid GREEN, see PowerEdge R640 Installation and Service manual
(https://topics-cdn.dell.com/pdf/poweredge-r640_Owners-Manual_en-us.pdf)
for further PSU LED status information.
2. Turn on both servers and check health status on the front left panel.
a. Verify that power switch indicator is GREEN (right front).
b. Verify that there are no AMBER health status indicator LEDs (left front).
Health Status
Power SwitchID LED
3. Verify that the LINK LED is ON solid GREEN for the MGMT1 and MGMT2 ports.
4. Verify the LINK LEDs are ON solid GREEN for the LCOM1 and LCOM2 ports.
6Establish local customer connections
For the following connections, route all cables through the CMA assembly to the side of the
cabinet. Secure the cables both in the CMA and at the side of the cabinet using Velcro straps.
CAUTION: All node connections must route through the CMA assembly to
maintain HA during service operations. Provide adequate length to maintain arm
movement and cable health.
1. Connect customer-supplied fibre-optic cables from the front-end and back-end SANs to
the appropriate metro node ports on both directors.
CAUTION: To avoid damage or contamination, do not touch the ends of any
fibre-optic cable.
CAUTION: Use redundant physical fibre channel links to connect each host to
the metro node directors, and each metro node director to the back-end storage.
To prevent data unavailability, ensure that each host in a storage view has paths
to both directors in the cluster, and that the multipathing configuration
distributes the paths evenly between directors A and B.
NOTE: The fiber-optic connections on HBA2 are inverted as compared to HBA1.
2. Connect metro node ‘CUST’ port to the customer IP network on both directors:
7Establish metro customer connections
NOTE: This section applies to dual cluster ‘metro’ system configurations only. Skip this
section for ‘local’ system configurations.
For the following connections, route all cables through the CMA assembly to the side of the
cabinet. Secure the cables both in the CMA and at the side of the cabinet using Velcro straps.
CAUTION: All node connections must route through the CMA (mechanical arm)
to maintain HA during service operations.
1. Connect the inter-cluster WAN IP connections. Ensure that each node or director has
two independent paths to each node or director in the other cluster. Metro node supports
Fibre IP WAN connections only.
8Next steps
• To configure the metro node, go to the SolVe Desktop or SolVe Online, then follow the
path VPLEX Admin Procedures → Configure → Configure metro node.
• For additional service, maintenance, and troubleshooting information, either
download the SolVe Desktop from SupportZone or go to the SolVe Online
(https://solveonline.emc.com/solve/home).
iQuick Resource Locator
To access the metro node additional documentation and videos, scan the Dell EMC QRL code
by using your smartphone.
https://www.dell.com/Storage/Metro_node

Other manuals for EMC PowerEdge R640

2

Other Dell Server manuals

Dell Wyse 5470 User manual

Dell

Dell Wyse 5470 User manual

Dell PowerEdge Operating manual

Dell

Dell PowerEdge Operating manual

Dell PowerEdge M820 Systems User manual

Dell

Dell PowerEdge M820 Systems User manual

Dell PowerEdge R200 Technical manual

Dell

Dell PowerEdge R200 Technical manual

Dell PowerEdge E07S Series User manual

Dell

Dell PowerEdge E07S Series User manual

Dell PowerEdge R420 User manual

Dell

Dell PowerEdge R420 User manual

Dell PowerEdge T710 User manual

Dell

Dell PowerEdge T710 User manual

Dell Dimension 2200 User manual

Dell

Dell Dimension 2200 User manual

Dell PowerEdge R920 Quick start guide

Dell

Dell PowerEdge R920 Quick start guide

Dell VTY3T User manual

Dell

Dell VTY3T User manual

Dell PowerEdge 2500 User manual

Dell

Dell PowerEdge 2500 User manual

Dell PowerEdge 6650 User manual

Dell

Dell PowerEdge 6650 User manual

Dell XC6320 User manual

Dell

Dell XC6320 User manual

Dell EMU01 User manual

Dell

Dell EMU01 User manual

Dell PowerEdge 1950 User manual

Dell

Dell PowerEdge 1950 User manual

Dell PowerEdge SC1420 User manual

Dell

Dell PowerEdge SC1420 User manual

Dell PS4000X User manual

Dell

Dell PS4000X User manual

Dell PowerEdge C6220 Quick start guide

Dell

Dell PowerEdge C6220 Quick start guide

Dell Active Fabric Manager Quick reference guide

Dell

Dell Active Fabric Manager Quick reference guide

Dell PowerEdge R450 Manual

Dell

Dell PowerEdge R450 Manual

Dell PowerEdge 2550 User manual

Dell

Dell PowerEdge 2550 User manual

Dell PowerEdge 1855 User manual

Dell

Dell PowerEdge 1855 User manual

Dell E56S Series Manual

Dell

Dell E56S Series Manual

Dell P72S User manual

Dell

Dell P72S User manual

Popular Server manuals by other brands

Lenovo ThinkServer TD230 manual

Lenovo

Lenovo ThinkServer TD230 manual

IntesisBox Modbus Server-Galaxy EIA232 installation manual

IntesisBox

IntesisBox Modbus Server-Galaxy EIA232 installation manual

Lenovo 70D6 User guide and hardware maintenance manual

Lenovo

Lenovo 70D6 User guide and hardware maintenance manual

IBM Power System 9009-41A manual

IBM

IBM Power System 9009-41A manual

TANDBERG S3 Administrator's guide

TANDBERG

TANDBERG S3 Administrator's guide

ANTAIRA STE-501C quick start guide

ANTAIRA

ANTAIRA STE-501C quick start guide

Dell EMC VxRail P580N owner's manual

Dell EMC

Dell EMC VxRail P580N owner's manual

Acer M19A System user guide

Acer

Acer M19A System user guide

PT MPS1000 Hardware manual

PT

PT MPS1000 Hardware manual

Fujitsu Primergy TX120 user guide

Fujitsu

Fujitsu Primergy TX120 user guide

Lenovo ThinkSystem SR630 V3 user guide

Lenovo

Lenovo ThinkSystem SR630 V3 user guide

HP ProLiant DL180 G6 Installation sheet

HP

HP ProLiant DL180 G6 Installation sheet

HP Integrity BL860c i2 User's & service guide

HP

HP Integrity BL860c i2 User's & service guide

Asus AP2500 Hardware reference guide

Asus

Asus AP2500 Hardware reference guide

Lenovo ThinkServer TS200v Informacje dotyczące gwarancji i wsparcia

Lenovo

Lenovo ThinkServer TS200v Informacje dotyczące gwarancji i wsparcia

Gigabyte R183-S97-AAD1 user manual

Gigabyte

Gigabyte R183-S97-AAD1 user manual

Supero SUPERSERVER 5016T-TB user manual

Supero

Supero SUPERSERVER 5016T-TB user manual

Amulet Hotkey DXZC series quick start guide

Amulet Hotkey

Amulet Hotkey DXZC series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.