Dell EMC PowerEdge R640 Manual

Other manuals for EMC PowerEdge R640

2

Other Dell Server manuals

Dell PowerEdge R320 Technical manual

Dell

Dell PowerEdge R320 Technical manual

Dell PowerEdge systems 6300 Service manual

Dell

Dell PowerEdge systems 6300 Service manual

Dell PowerEdge R610 User manual

Dell

Dell PowerEdge R610 User manual

Dell VxRail G560 User manual

Dell

Dell VxRail G560 User manual

Dell PowerEdge C410X User manual

Dell

Dell PowerEdge C410X User manual

Dell PowerEdge R610 User manual

Dell

Dell PowerEdge R610 User manual

Dell PowerEdge 2500SC Manual

Dell

Dell PowerEdge 2500SC Manual

Dell DX6000G User manual

Dell

Dell DX6000G User manual

Dell PowerEdge R630 Quick start guide

Dell

Dell PowerEdge R630 Quick start guide

Dell P570 User manual

Dell

Dell P570 User manual

Dell PowerEdge C6145 User manual

Dell

Dell PowerEdge C6145 User manual

Dell PowerEdge 4350 Guide

Dell

Dell PowerEdge 4350 Guide

Dell PowerEdge R810 Parts list manual

Dell

Dell PowerEdge R810 Parts list manual

Dell S5000 Series User manual

Dell

Dell S5000 Series User manual

Dell Wyse ThinOS T10 User manual

Dell

Dell Wyse ThinOS T10 User manual

Dell PowerEdge 4350 User manual

Dell

Dell PowerEdge 4350 User manual

Dell PowerEdge C8000 User manual

Dell

Dell PowerEdge C8000 User manual

Dell PowerEdge R715 User manual

Dell

Dell PowerEdge R715 User manual

Dell PowerEdge R530xd User manual

Dell

Dell PowerEdge R530xd User manual

Dell PowerEdge Operating manual

Dell

Dell PowerEdge Operating manual

Dell PowerEdge 2300 User manual

Dell

Dell PowerEdge 2300 User manual

Dell PowerEdge Cluster FE100 User manual

Dell

Dell PowerEdge Cluster FE100 User manual

Dell PowerEdge Cluster SE500W Guide

Dell

Dell PowerEdge Cluster SE500W Guide

Dell PowerEdge 6850 Technical manual

Dell

Dell PowerEdge 6850 Technical manual

Popular Server manuals by other brands

HP Tc2120 - Server - 256 MB RAM installation guide

HP

HP Tc2120 - Server - 256 MB RAM installation guide

Lenovo ThinkServer RD230 manual

Lenovo

Lenovo ThinkServer RD230 manual

Avocent CPS810 Installer/user guide

Avocent

Avocent CPS810 Installer/user guide

FreeWave HT2+ installation guide

FreeWave

FreeWave HT2+ installation guide

GIGA-BYTE TECHNOLOGY G492-Z50 user manual

GIGA-BYTE TECHNOLOGY

GIGA-BYTE TECHNOLOGY G492-Z50 user manual

Lanner HTCA-E400 user manual

Lanner

Lanner HTCA-E400 user manual

Bull NovaScale T840 E2 user guide

Bull

Bull NovaScale T840 E2 user guide

Asus RS740-E70RS24-EG Configuration guide

Asus

Asus RS740-E70RS24-EG Configuration guide

Meinberg LANTIME M300/TCR manual 

Meinberg

Meinberg LANTIME M300/TCR manual 

HP ProLiant SL335s G7 Maintenance and service guide

HP

HP ProLiant SL335s G7 Maintenance and service guide

ZyXEL Communications VANTAGE RADIUS 50 user guide

ZyXEL Communications

ZyXEL Communications VANTAGE RADIUS 50 user guide

Lantronix xDirect-IAP quick start guide

Lantronix

Lantronix xDirect-IAP quick start guide

Fujitsu PRIMEQUEST 2400E3 General description

Fujitsu

Fujitsu PRIMEQUEST 2400E3 General description

IBM 9040-MR9 manual

IBM

IBM 9040-MR9 manual

IBM 306m - eServer xSeries - 8849 user guide

IBM

IBM 306m - eServer xSeries - 8849 user guide

green hippo Hippotizer Nevis+ quick start guide

green hippo

green hippo Hippotizer Nevis+ quick start guide

IBM 8203-E4A Brochure & specs

IBM

IBM 8203-E4A Brochure & specs

Ruijie Cloud Class RCD6000E V3 Series user manual

Ruijie

Ruijie Cloud Class RCD6000E V3 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Metro node
Hardware Installation Guide
Copyright © 2020 Dell Inc. or its subsidiaries. All Rights Reserved.
Dell P/N: 6Y7M8 Rev. A00
2020 - 12
Before you begin
Review the following documents:
Technical and environmental specifications
– https://topics-cdn.dell.com/pdf/poweredge-r640_reference-guide2_en-us.pdf
Dell EMC Rail Installation Guide
– https://downloads.dell.com/Manuals/all-products/esuprt_ser_stor_net/esuprt_poweredge/
poweredge-r640_Setup-Guide2_en-us.pdf
Dell EMC Cable Management Arm (CMA) Installation Guide
– For detailed information, see the guide available at Dell EMC Online Support
(https://www.dell.com/support).
• Confirm that following are available:
- metro node servers–2
- Cable Management Arm Kit–1
• Verify that the equipment is fully acclimated to the data center environment.
1Install metro node servers
1. Install the servers in the rack referencing the Dell EMC Rail Installation Guide:
a. Remove slide rails from boxes and install in two consecutive 1U locations in target rack.
b. Remove server nodes from boxes and mount them on the installed slide rails.
NOTE: Mount the server with the lower Dell Service Tag (DST) in the upper position.
2. Install one LCD bezel on each server.
3. Save 10 GbE SFP optical transceivers for installation in the next section.
2Install Cable Management Arm Kit
1. Attach the CMA attachment bracket to the server slide rails for each server.
2. Attach the CMA tray to the server slide rails for each server.
3. Attach the pre-wired Cable Management Arm Kit to the server slide rail assembly of each
server nodes.
a. Connect the inner CMA clip (1) to the left inner sliding rail.
b. Connect the outer CMA clip (2) to the left outer fixed rail.
c. Repeat for each server node.
d. Secure the cable loop and red service cable to the side of the rack with Velcro straps.
CAUTION: Ensure that the cable loop is securely supported on the rack and
does not pull on the cables in the management arms.
3Connect CMA kit cables to the Server nodes
The Port Map Label image below shows the port assignment for the following steps:
1. Install WAN SFP modules into the two WAN ports on each node.
a. Insert one 10 GbE SFP module into the port marked WAN1 on the port map.
b. Insert one 10 GbE SFP module into the port marked WAN2 on the port map.
c. To confirm that these are latched securely, pull gently on each of the
SFP I/O modules. If SFP is loose:
1. Release the spring latch.
2. Push the SFP fully in.
3. Close the spring latch.
4. Repeat for each node.
NOTE: For local system configurations: a) Install the WAN SFPs in the WAN port for
safekeeping and/or potential future use, b) Ensure that the cable plugs are in place to
protect the SFP when not in use.
2. Connect the LCOM Direct Attach Copper (DAC) cables to the two LCOM ports on
eachnode.
a. Connect the black cable labeled LCOM1 to the port marked LCOM1 on the port map.
Repeat at each node.
b. Connect the black cable labeled LCOM2 to the port marked LCOM2 on the port map.
Repeat at each node.
c. Verify that cables are seated securely by pulling lightly on the cable at each node
connection.
3. Connect the MGMT Ethernet cables to the two MGMT ports on each node.
a. Connect the green cable labeled MGMT1 to the MGMT1 port as shown on the
portmap. Repeat at each node.
b. Connect the violet cable labeled MGMT2 to the MGMT2 port as shown on the
portmap. Repeat at each node.
c. Verify that the cables are securely latched at each node connection by pulling lightly on
the cable at each node connection.
4. Connect the AC power cables to the power supply units on each node.
a. Connect the black power cable to PSU1/the black ‘AC Power’ block on the port map.
b. Connect the gray power cable to PSU2/the gray ‘AC Power’ block on the port map.
c. Repeat at each node.
d. Verify that the power cable routing allows each server node to move freely on the
sliderails.
CAUTION: Loop the power cable and secure to the PSU handle with the provided
Velcro straps as shown in the following figure. Ensure the strap lifts the power
cable to prevent binding when server is extended during service.
4Connect power cables to redundant utility power sources
Connect the black and the gray power cables to separate utility power feeds.
CAUTION: Redundant power connections are required to maintain HA.
Ensure gray and black cords connect to separate power supplies.
1. Connect the gray power cables to the utility A Power Distribution Unit (PDU).
2. Connect the black power cables to the utility B PDU.
5Check metro node interconnections and power
1. Verify that each node is getting power from BOTH power zones. Verify that the PSU
handle glows solid GREEN for both PSUs in each node.
CAUTION: If the PSU LED is OFF, check the power cable connections.If the
LED is not solid GREEN, see PowerEdge R640 Installation and Service manual
(https://topics-cdn.dell.com/pdf/poweredge-r640_Owners-Manual_en-us.pdf)
for further PSU LED status information.
2. Turn on both servers and check health status on the front left panel.
a. Verify that power switch indicator is GREEN (right front).
b. Verify that there are no AMBER health status indicator LEDs (left front).
Health Status
Power SwitchID LED
3. Verify that the LINK LED is ON solid GREEN for the MGMT1 and MGMT2 ports.
4. Verify the LINK LEDs are ON solid GREEN for the LCOM1 and LCOM2 ports.
6Establish local customer connections
For the following connections, route all cables through the CMA assembly to the side of the
cabinet. Secure the cables both in the CMA and at the side of the cabinet using Velcro straps.
CAUTION: All node connections must route through the CMA assembly to
maintain HA during service operations. Provide adequate length to maintain arm
movement and cable health.
1. Connect customer-supplied fibre-optic cables from the front-end and back-end SANs to
the appropriate metro node ports on both directors.
CAUTION: To avoid damage or contamination, do not touch the ends of any
fibre-optic cable.
CAUTION: Use redundant physical fibre channel links to connect each host to
the metro node directors, and each metro node director to the back-end storage.
To prevent data unavailability, ensure that each host in a storage view has paths
to both directors in the cluster, and that the multipathing configuration
distributes the paths evenly between directors A and B.
NOTE: The fiber-optic connections on HBA2 are inverted as compared to HBA1.
2. Connect metro node ‘CUST’ port to the customer IP network on both directors:
7Establish metro customer connections
NOTE: This section applies to dual cluster ‘metro’ system configurations only. Skip this
section for ‘local’ system configurations.
For the following connections, route all cables through the CMA assembly to the side of the
cabinet. Secure the cables both in the CMA and at the side of the cabinet using Velcro straps.
CAUTION: All node connections must route through the CMA (mechanical arm)
to maintain HA during service operations.
1. Connect the inter-cluster WAN IP connections. Ensure that each node or director has
two independent paths to each node or director in the other cluster. Metro node supports
Fibre IP WAN connections only.
8Next steps
• To configure the metro node, go to the SolVe Desktop or SolVe Online, then follow the
path VPLEX Admin Procedures → Configure → Configure metro node.
• For additional service, maintenance, and troubleshooting information, either
download the SolVe Desktop from SupportZone or go to the SolVe Online
(https://solveonline.emc.com/solve/home).
iQuick Resource Locator
To access the metro node additional documentation and videos, scan the Dell EMC QRL code
by using your smartphone.
https://www.dell.com/Storage/Metro_node