Desisti SUPER LED F7rp User manual

This Manual is applicable to the Revised May 11st 2016
De Sisti SUPER LED F7
Pag 1.
SUPER LED F7rp
160W LED Fresnel SPOTLIGHT 90-240V 50-60 Hz
(white light, either Tungsten or Daylight balanced Correlated Color Temperature)
INSTRUCTION MANUAL
MANUFACTURER
REPRESENTATIVE
ILT Italy S.r.l.
Via Cancelliera # 10a, 00041 Albano Laziale (Rome- Italy).
Tel. +39/06/902901 Fax. +39/06/90231051
U.R.L.: www.desisti.it E-mail: desisti@desisti.it
1. INTRODUCTION
Congratulations on your purchase of a SUPER LED F7rp lighting fixture.
Our commitment to Total Customer Satisfaction and our consolidated experience and leadership in design
innovation and manufacturing of lighting products for the professional Entertainment Industry means you can
depend upon the quality of this product.
The SUPER LED F7rp is a compact, highly efficient Fresnel lens spotlight using a LED ARRAY combined with
the DE SISTI Patented optical system to optimize the photometric performances of LED ARRAYS when
utilized in combination with either Fresnels or Plano Convex lenses.
The Lighting Fixture is DMX Controlled and includes a number of parameters that can be set locally, it is
equipped with 90-240V 50-60 Hz power supply for AC feed and it is available with either Tungsten or Daylight
Balanced CCT.
It utilizes Standard accessories from the DE SISTI range of equivalent Fresnel Lens size, such as Barndoor,
Colour Frame, Cones, scrims.
Manual Operated
Pole Operated

This Manual is applicable to the Revised May 11st 2016
De Sisti SUPER LED F7
Pag 2.
2. YOKE AND ACCESSORIES ASSEMBLY
3. POWER AND DMX DAISY CHAIN
The SUPER LED F7rp permits both POWER and DMX DAISY CHAIN.
In fact each Fixture is respectively equipped with:
For DMX:
•1 XLR5 pin Panel Mount Male (DMX IN)
•1 XLR5 pin Panel Mount Female (DMX OUT)
For Mains Supply
•1 20A Powercon NAC3MPA BLUE (POWER IN)
•1 20A Powercon NAC3MPB WHITE (POWER OUT)
It is recommended to Daisy Chain a Max of 10 fixtures, even if the limitations
imposed by DMX Standards are for an higher q.ty of units and even if the
Powercon Connections are rated for 20A max.

This Manual is applicable to the Revised May 11st 2016
De Sisti SUPER LED F7
Pag 3.
4. SAFETY INSTRUCTIONS
Professional use: This luminaire has been designed for professional use and must be operated by
qualified personnel only. Not for residential use.
Grounding: WARNING: THIS LUMINAIRE MUST BE GROUNDED
WARNING: Disconnect Power CORDS before
any maintenance work or opening the FUSE HOLDER.
Risk of serious injury.
Electrical connections: IMPORTANT The cores in this mains lead are colored in accordance with the
following code:
Europe
America
Ground
Green & yellow
Green or green & yellow
Neutral
Blue
White
Live
Brown
Black
In case the colors of the cores do not correspond to the colors of the connection points on your plug, please
proceed as follows:
•the green or green and yellow core must be connected to the connection point marked with the letter E or
with the symbol or colored in green or in green - yellow;
•the blue (or white) core must be connected to the connection point marked with the letter N or colored in
black;
•the brown (or black) core must be connected to the connection point marked with the letter L or colored in
red.
Working conditions
Working Position
Lighting fixture: Max. Tilting 90° from horizontal
Ambient Temperature, ta
at the place of installation and Storage
Minimum 10°C, maximum +40°C
Humidity
at the place of installation and Storage
25-80% (not condensing)
Minimum distances from
inflammable surfaces
Top
Back
Sides
Front
0,2 m.
0,1 m.
0,1 m.
0,75 m.
The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above
table are the minimum distances recommended. Other requirements for safe use are:
A. Do not cover the apertures of the luminaire housing. They are essential for correct ventilation.
B. Use only original accessories and spares from De Sisti Lighting.
C. Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the
luminaire weight.
D. In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting.
E. A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between
the suspension point and the eyelet at the front of the body.
WARNING: DO NOT MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE.
5. INSTALLATION INSTRUCTIONS
The following procedure should be adopted:
Before connecting the luminaire to the electrical mains ensure that:
A. Earth line is present on the power socket.
B. The mains voltage is within the rated range of the luminaire (see technical data on the rating label)
C. The front safety shield is present and in good condition.
It consists of a Fresnel lens made by borosilicate un-toughened glass,
with a Diameter = 175 mm, thickness = 5 mm type ( 3 min ).
WARNINGS:
•Do not operate the product if the ambient temperature exceeds 40° C
•Provide a minimum clearance of 0,1m (4 in.) around fans and air vents.
•SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE

This Manual is applicable to the Revised May 11st 2016
De Sisti SUPER LED F7
Pag 4.
BECOME VISIBLY DAMAGED TO SUCH AN EXTENT THAT THEIR EFFECTIVENESS IS
IMPAIRED, FOR EXAMPLE BY CRACKS OR DEEP SCRATCHES.
•THE LUMINAIRE SHALL ONLY BE USED COMPLETE WITH ITS PROTECTIVE SHIELD
D. Applying power:
Never connect to dimmer power. Install a power plug on the power cable using the following pin assigment:
1 : Neutral 2 : Live Green/Yellow : Ground - This fixture must be connected to ground.
Make sure the local power voltage is within the range specified. If so; connect the power cable and turn the
power on.
E. Stand Alone operation:
Using the navigation buttons and display readout (refer to the “Local Menu” chapter)
navigate to Manual and set the desired intensity (for additional operations see “Local Menu” chapter)
F. DMX operation:
Connect a DMX cable
Navigate to Address mode (Addr) and set the desired address, (refer to the “Local Menu” chapter).
Connect to DMX controller (refer to the “Channel Setting” in the “Local Menu” chapter) and Use it.
6. LOCAL MENU
PGM PORT For Firmware Upgrade
FUNCTION 1 Scrolling UP / Increases value “function key”
ENTER Select / Confirm
FUNCTION 2 Scrolling DOWN / Decreases value “function key”
Display When the push buttons are not used for more than 15
seconds the display will go OFF. It will go ON again
anytime a push button is activated.
DMX Presence Shows the presence of DMX (LED lit = DMX present)
DEFAULT SETTINGS ARE INDICATED IN BOLD LETTERS ON THE FOLLOWING TABLE:
The following are the BASIC FUNCTIONS and COMMANDS that are provided on the LOCAL MENU of the LED
FRESNEL. The unit is provided with a USER MENU accessible instantly on the product.
The unit has also a SERVICE MENU that is only accessible through a PASSWORD and is reserved for QUALIFIED and
TRAINED PERSONNEL:
1st MENU
Displayed
(scrolling with the and the buttons)
2nd MENU
Displayed
(after pressing the Xthat stands for ENTER)
Explanation of Each MENU FUNCTION

This Manual is applicable to the Revised May 11st 2016
De Sisti SUPER LED F7
Pag 5.
DMX ADDRESS
This Function is to SET the DMX address from 1to 512 (Product is delivered with
default settingof the DMX address at 1)
Once the C001 is displayed, act on the button to increase the address to the
desired value.
Temporary push will increment the value by 1, if the button is kept pushed the
increment on numbers is getting fast.
Once the desired Address number is accomplished press X(“ENTER”) to make it
active
LOCAL DIMMING CONTROL
This Function is to LOCALLY DIM the LED INTENSITY from 0 to 100% (Product is
delivered with default setting of the DIMMER at 0) moving a Potentiometer control.
The intensity goes in increments of 1/100% so the display will show 000%with the
dimmer at 0% and FULL with the dimmer at 100%.
Once the desired Lighting Level is accomplished moving the Potentiometer control
and it is wanted to leave that level and go to other functions of the MENU, press
“ENTER”.
LOCAL OR REMOTE CONTROL SETTINGS
The LED Fresnel has the facility to block the LOCAL DIMMING SETTING and maintain
it when the POWER is turned first OFF and than ON again.
This allows for the LIGHT to be TUNED and FOCUSED locally and its dimming level
can be blocked, so that for instance a system lighting a SET can be operated by a
remote switch or simple brakers by TURNING POWER ON.
The relevant menu to access this function is CTRL, to enter in this menu press X
(“ENTER”), it is than possible to select either DMX or AUTO by acting on the or
button and than press X(“ENTER”) again. The machine is set to DMX as default.
•In DMX mode: the Fixture accepts DMX control….if in this mode the local
DIMMING CONTROL is SET to a level the Light behaviour will follow the HTP
(Highest Takes Precedence) modality, in other words it will keep the local
DIMMING setting until the DMX level of the specific channel will be higher, from
that level onwards the DMX level will take precedence. In this condition if the
DMX connection is removed, the light will keep the last level….until power is
ON. It will reset and Start at 0after Power OFF and ON again.
In AUTO mode: the light will ignore any DMX control. In this mode any local
dimming setting will be maintained and will be automatically recalled after
power off, when turning the power on again.

This Manual is applicable to the Revised May 11st 2016
De Sisti SUPER LED F7
Pag 6.
1st MENU
Displayed
(scrolling with the and the buttons)
2nd MENU
Displayed
(after pressing the Xthat stands for ENTER)
Explanation of Each MENU FUNCTION
TEMPERATURE
This function Displays in real time the LED ARRAY Case temperature in °C.
When pressing Enter again you exit from the temperature display.
The steady state TEMPERATURE of the ARRAY reaches approx. 55°C after many
hours of continuous operation with an ambient temperature of 25-30°C.
The Thermal Handling of the LED is Automatically handled by the local electronics
and the LED will operate until the ARRAY temperature reaches 80°C, that anyway is
still way within the prescribed maximum nominal prescribed by the ARRAY
manufacturer that is 105°C.
In case the ARRAY temperature reaches 80°C the unit will automatically turn off.
Even in extreme Ambient temperature conditions the LED ARRAY shall never reach
the 80°C limit.
The above protection threshold is there to protect the LED ARRAY from stressed
working conditions in case some other failures or specially critical working conditions
are causing an over-temperature.
CHANNEL SETTING (RESOLUTION & FUNCTION)
This Function is to set the DIMMING RESOLUTION either at 8 bits or at 16 bits.
Once CHAN is displayed, act on the or buttons to scroll through the following
choises:
•8D: 8 bits resolution (the display will show 8D and this is the default setting).
The Fixture utilises 1 DMX Circuit for the Light Dimming, which is the
BASE CIRCUIT set in the ADDRESS.
•8DS: NOT ACTIVE (for future use):
The foreseen function for this setting is: 8 bits resolution and STROBE (the display will show
8DS). The Fixture will utilise 2 DMX Circuits,
the BASE CIRCUIT set in the ADDRESS will be the LIGHT DIMMING
and the second circuit (BASE +1) will be the STROBE
•16D: 16 bits resolution (the display will show 16D).
The Fixture utilises 2 DMX Circuits,
the BASE CIRCUIT set in the ADDRESS is the Coarse Dimming,
the second Circuit (BASE +1) is the Fine Dimming.
•16DS: NOT ACTIVE (for future use):
The foreseen function for this setting is: 16 bits resolution and STROBE (the display will show
16DS). The Fixture will utilise 3 DMX Circuits,
the BASE CIRCUIT set in the ADDRESS will be the Coarse Dimming,
the second Circuit (BASE + 1) will be the Fine Dimming.
the third CIRCUIT (BASE + 2) will be the STROBE
Of course the 16 bits function is useful if the corresponding circuits on the DMX
LIGHTING BOARD are also set at 16 bits.
WARNING: if the LED FRESNEL is set at 16 bits, but more units are having a consecutive unitary
address (for instance first fixture set at Address 1, second fixture set at Address 2 and so forth,
the DMX Channel controlling the Coarse Dimming of the second unit, will also control the fine
dimming of the first unit. In this case it is recommended that all fixtures are set to 8 bits
resolution).
DMX LEVEL
It Shows the DMX Input level on percentage (0-99% and FULL) received effectively
from the Fixture.
Press ENTER to exit this MENU.

This Manual is applicable to the Revised May 11st 2016
De Sisti SUPER LED F7
Pag 7.
7. CHARACTERISTICS AND PERFORMANCE DATA
DESCRIPTION
VALUE
DESCRIPTION
VALUE
LED Power
160 W
Protection Type
IP 23 Rain Protected
Power
Cosumption
180W
Max Housing temperature
70 °C
DMX Data link
USITT DMX512-A
This product uses a 5-pin XLR for
DMX input and output.
Use a shielded data cables.
Do not overload the daisy chain.
Up to a maximum of 32 devices
can be used on a single DMX
chain.
Weight of Fixture
M.O.
P.O.
9,4 kg.
10,7 kg.
Weight of barndoor
4 leaf
8 leaf
0,63 kg.
0,85 kg.
DMX
Channels:
1 at 8bit: Dimmer
2 at 16bit: Dimmer
Weight of color frame
0,3 kg.
Size of scrims & color
frame
Seat Diameter
Acc.ies
Diameter
187 mm.
185 mm ( 7”1/4 )
Size of Barndoor ring
Seat Diameter
Ring Diameter
192 mm.
190 mm ( 7”1/2 )
Protection
Class
Class 1–ground connection required
Lens diameter
175 mm.
Specifications subject to change without notice.
8. DIMENSIONS
9. PERIODIC INSPECTION & MAINTENANCE
This product requires very little routine maintenance, if any, but has special cleaning instructions:
Disconnect fixture from power and allow it to cool for 10 min.
1. Vacuum or gently blow away any dust from fan blades and grills
2. Very gently clean the LED with Isopropyl alcohol.
3. Clean the lenses with a soft damp cloth.
4. Check the condition of the safety shield (see chapter: Installation Instructions) before every use.
5. Check Power supply cable and DMX control cable proper conditions

This Manual is applicable to the Revised May 11st 2016
De Sisti SUPER LED F7
Pag 8.
10.SAFETY STANDARDS
Europe: The product conforms the Applicable European Directives & Standards
Low Voltage Directive: 73/23/EEC (as amended by 93/68/EEC)
EMC Directive: 89/336/EEC (as amended by 92/31/EEC & by 93/68/EEC)
Europen Standards:: EN 60598-2-17, EN 60598-1 , EN 55015 , EN 61547
Disposing of this product:
Help preserve the environment! Ensure that this product is recycled at the end of its life.
This product is in compliance with the RoHS and WEEE directives.
This manual suits for next models
3
Table of contents
Other Desisti Spotlight manuals

Desisti
Desisti Muses of Light ERATO User manual

Desisti
Desisti Muses of Light CLIO User manual

Desisti
Desisti REMBRANDT PICCOLO 575 w SE User manual

Desisti
Desisti SOFT LED 2 XL Vari-White User manual

Desisti
Desisti Muses of Light AUREA User manual

Desisti
Desisti SUPER LED F10 VW User manual

Desisti
Desisti PICCOLETTO DIM User manual

Desisti
Desisti REMBRANDT PICCOLO 1.200 w SE User manual