Factory Default Values for Version 1.05
ADR FUNCTION Default Description D1 D2 D3 D4 D5 D6 D7 D8 D9
01 ZONE PROGRAMMING Zone1: Perimeter delayed, zone2-5:interior instant
Zone 6: 24hr 366662
02 ZONE BYPASS All zones bypassable 111111
03 ZONE ACTION Alarm on short and open all zones 000000
04 OUTPUT TYPE Steady output all zones 222222
05 ZONE RESPONSE TIME Use default response time - Set at 300 ms 000000
06 PROGRAMMED RESPONSE TM Set to 1 second 100
07 ZONE RESTORE FUNCTIONS Restore when disarmed 222222
08 OUTPUT PROGRAMMING PO1:Burg/fire alarm (siren ) PO2:Intrusion (strobe)
PO3:System reset 802
09 USER CONTROL Duress/Guest code, arm warning, disabled exit
sounder enabled 00010
10 GENERAL CONTROL 50Hz, swinger shunt disabled, residential mode,
quick arm, easy exit, force bypass enabled for all
zones
000111116
11 KEYPAD ASSIGNMENT Keypad 1: led, keypad2:disabled
Keypad 3: disabled,keypad4: disabled 1000
12 - 18 ZONE ALPHA LABELS Refer to manual for further instructions
19 SPECIAL KEYS Fire/help/panic key disabled 000
20 REPORT CONTROL Open/close report disabled, all other reports go to
phone number 1 0111
21 PHONE NUMBER CONTROL Dial tone/pulse, call back disabled, ring count=0,no
dialed delay 10000
22 DIAL ATTEMPTS Dial attempts set to 3 03
23 TIME DELAYS Entry delay = 30sec, exit delay 30secs,
Siren cutoff = 4 min 030 030 004
24 KEYPAD REPORT Keypad Emergency Key reports enabled 11 11 11 11
25 ZONE ALARM REPORT All zone alarms reported 11 11 11 11 11 11
26 ZONE ALARM RESTORAL Enabled 11 11 11 11 11 11
27 ZONE TROUBLE REPORT Disabled 00 00 00 00 00 00
28 ZONE TROUBLE RESTORAL Disabled 00 00 00 00 00 00
29 ZONE BYPASS REPORT Zones bypassed reports enabled 11 11 11 11 11 11
30 ZONE BYPASS RESTORAL Enabled 11 11 11 11 11 11
31 OPEN/CLOSE DURESS REPORT Enabled 11 11 11 11 11 11
32 BATTERY/ AC FAIL REPORT Low batt/AC fail report enabled 11 11 11 11
33 PROGRAMMINGREPORT Remote/local programming report enabled 00 00 00 00
34 SYSTEM REPORT Disabled 00 00 00 00
35 EXIT ERROR/RECENT CLOSE/COMM Disabled 00 00 00 00
36 TEST REPORTS/ SYSTEM TEST Auto test/Comm test report enabled.
System in test/restore reports disabled 11 11 00 00
37 ACCOUNT CODES Account code # one/account code # two 00000000
38 PHONE #1 FORMAT Contact ID, 10pps, 1800 data - 2300 ack 901
39 PHONE #2 FORMAT Contact ID, 10pps, 1800 data - 2300 ack 901
40-41 PHONE NUMBER #1 Central station no # 1
42-43 PHONE NUMBER #2 Central station no # 2
44-45 PHONE NUMBER #3 Remote programming number
46 PROGRAMMER/MASTER CODE Default codes are 9876 and 1234 98761234
47 DEFAULT EEPROM No action 0
48 AUTOMATIC TEST REPORT INTERVAL disabled 0
49 HOURS TO FIRST AUTO TEST REPORT Set to report 12 hours from the time the panel is
powered up 012
50 AC FAILURE REPORT DELAY 60 minutes 060
Zone Types
The zone types can be changed using the values shown below and programmed in address 01:
0. DISABLED 4. INTERIOR FOLLOWER 8. PERIMETER FOLOWER C. (*2) 24 HOUR FIRE w/VERIFY
1. PERIMETER INSTANT 5. INTERIOR HOME/AWAY 9. SILENCE AUDIBLE D. (*3) FIRE
2. 24 HOUR 6. INTERIOR INSTANT A. (*0) KEYSWITCH TOGGLE
3. PERIMETER DELAYED 7. PERIMETER HOMEGUARD B. (*1) KEYSWITCH ON/OFF
PERSONAL DIALING FORMAT
This program is specifically for those who wish to utilize the personal dialing format.
ADR FUNCTION Default Description D1 D2 D3 D4 D5 D6 D7 D8 D9
25 ZONE ALARM REPORT Zones reported 11 22 33 44 55 66
37 ACCOUNT CODES Account code # one/account code # two 1111 1111
38 PHONE #1 FORMAT Personal dialing, 10pps, 1800 data - 2300 ack C0 1
39 PHONE #2 FORMAT Personal dialing, 10pps, 1800 data - 2300 ack C0 1
40-41 PHONE NUMBER #1 Personal number no#1
42-43 PHONE NUMBER #2 Personal number no#2
Note: The program addresses that must be filled out are shown with above. When the panel is in alarm and has dialed the personal phone number, the user will hear
a number of beeps that indicates the zone number. One beep followed by another one indicates that zone one is violated. This sequence will be repeated until the user
responds by pressing either the 2,5,8 or 0 key for three seconds on the telephone handset during the three second pause between each sequence. Reporting: DS
recommends that only address 25 be enabled using the setting above. Other reports should be disabled by entering 00 in the appropriate address location.