Devatec ElectroVap MC2 Series User manual

1 Pictures for illustrating purposes only
Technical manual
Remote control
for
ElectroVap MC2 Steam Bath

2 Pictures for illustrating purposes only
Description 3 - 4
Dimensions & Installation 5
Electrical connections 6 to 8
Use & Settings 9 to 13
STEAM BATH MC REMOTE CONTROL
Contents

3 Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Description
1 2 3 4 5
6
7
1. Steam Production Power On/Off Button
2. Date / Time Access Setting Button
3. Hammam light Power On/Off Button
4. Remote Control On/Off Button
5. 12 V Power Inlet Jack (for optional AC adaptor)
6. Navigation Pad
7. OK Button

4 Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Description
The Steam Bath MC Remote Control gives you distant control over your steam bath. Two models
are available :
Model 1 : includes the remote control, a 12V supply transformer, a 3 dry contact control board
and a RS485 board.
Model 1 is capable of :
• powering manually on or off the steam production or automatically thanks to a weekly
schedule (via terminals 3 & 4 of the steam bath);
• Offering 3 dry contacts on the 3 contact control board (see under the list of possible
functions).
Model 2 : includes the remote control, a 12V supply transformer, a 8 dry contact control board
and a RS485 board.
This model is capable of :
• powering manually on or off the steam production or automatically thanks to a weekly
schedule (via terminals 3 & 4 of the steam bath);
• Offering 8 dry contacts on the 8 contact control board (see under the list of possible
functions).
Remote control 230/12V
Transformer 3 dry contact
board
Possible actions with the Steam Bath MC Remote Control :
• Switching on and off the steam bath manually or on an automatic scheduled basis;
• Pre-set the desired room temperature;
• Select the perfume intensity (in case of a perfume device installation);
• Switching on or off room light(s);
• Switching on or off musics;
• Powering ventilation or exhausting air out of the room.
8 dry contact board
RS485
board

5 Pictures for illustrating purposes only
INSTALLATION
STEAM BATH MC REMOTE CONTROL
Dimensions & Installation
95
22335
27
86
DIMENSIONS
• Weight = 370g
Remove the lateral screws of the Remote
Control and dissemble the box. Set the
bottom on wall at the desired place and
mark one of the 4 holes.
Drill a ø 3 or 4mm hole, insert peg and
secure the bottom on wall with a screw.
1
Make sure that the box is at level and mark
up the other 3 holes. Take the bottom off
wall and drill the holes, insert pegs and
screws and screw them up .
Set back the Remote Control front panel
and screw back the two lateral screws.
The installation of the Remote Control is now completed.
Please now wire and set the Steam Bath MC Remote Control.

6 Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Electrical connexions
220V
0 0
12V
Transformer
220V/12V
100VA
Remote control board Ref: 500650/03
The wiring of the equipment described under must be made with a 0.75 mm2 maximum
flexible wire.
STEAMBATH12VTRANSFORMER
230/12V ACADAPTOR
Mains socket
230V
N L
Terminals on DIN
rail of the steam
generator
• Attach the 230/12V transformer inside the
electrical compartment of the steam generator
with the supplied set of bolts and nuts.
• Connect transformer wires as per attached
drawing.
61
Red terminal to plug on
On/Off switch
Black terminal to plug
on red terminal (s.a.
attached picture)
60
Red terminal

7 Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Electrical connexions
RS485board
RS485 board
Ref: 500800/01
Steam generator main board
Ref: 500101/05
The wiring of the equipment described under must be made with a 0.75 mm2 maximum
flexible wire.
• Clamp the RS485 board onto the DIN
rail of the steam generator.
• Connect the RS485 grey ply to the
steam generator board
• Wire the RS485 3 pin connector to the
Remote Control board J11 connector
with reinforced wire as follows :
485+ on 2
485– on 1
GND on 3
Remote control board Ref: 500650/03
GND
(reinforced)
GND
(reinforced)
Reinforced wire

8 Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Electrical connexions
3CONTACTBOARD
The wiring of the equipment described under must be made with a 0.75 mm2 maximum
flexible wire.
8CONTACTBOARD
X12
678
X2
F1:
2 A
11
12
DEVATEC
Réf:500101-05
X18
X1
910
F4:50mA
Transformer
115/15V
15V
X3 14
13
X4
17
16
15
Réf.: 500400-03
31
31
X23
30
30 38
X22
33
34
X20
32 33 34
36
37
36
X21
35 37
K22
K20 K21
• Attach the 3 contact board onto the stand-offs
located under the steam generator main board with
M4 8mm long screws.
• Connect the grey ply of the 3 contact board to the
connector X18 of the steam generator main board.
• The 3 contact board makes possible to connect
three optional devices on terminals : 30-31, 33-34
and 36-37 (NO contact) or terminals : 31-32, 34-35
and 37-38 (NF contact) (perfume device,
disinfectant device, ventilation or other… )
1 2
NO
• Attach the 8 contact board onto the stand-offs
located under the steam generator main board
with M4 8mm long screws.
• Connect the grey plies of the 8 contact board to
the connectors X16 & X18 of the steam generator
main board.
• The 8 contact board makes possible to connect
eight optional devices on terminals : 1-2, 4-5, 7-8,
10-11, 13-14, 16-1/, 19-20 and 22-23 (NO contact)
or terminals : 8-9, 11-12, 14-15 or 17-18 (NF
contact) (perfume and disinfectant devices,
ventilation, air exhaust, urgent stop or other… )
12 8
457 9 10 12
11 13
X1
RL1
X2 X3
RL2
X4 X5
RL3
X12 X9
RL4
16
14 15 17 18 20
19 23
22
X7
X6 X8
RL7 RL8
RL5 RL6
X10
X18
X16
DEVATEC
REF: 500101_05
X11 DEVATEC
REF: 500660/01
NO
4 5 19 20
NO NO
22 23
30 31 32
NO NF
33 34 35
NO NF
36 37 38
NO NF
10 11 12
NO NF
16 17 18
NO NF
13 14 15
NO NF
7 8 9
NO NF

9 Pictures for illustrating purposes only
DISPLAYSYMBOLS
STEAM BATH MC REMOTE CONTROL
Use & Settings
DISPLAYREADING
45°C
Mo 00:00
45°C - +
Steam generator in run Hammam lighting on
Steam generator on halt Hammam lighting off
Perfume on Music (option)
Pre-set temperature Auto-timer
Steam generator on-line Steam generator off-line
Room temperature
45°C

10 Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Use & Settings
Day / time settings
45°C
Mo 00:00
45°C - +
2
Pressing button 2 highlights the day and hour information. Press the « OK » button and set the
day by pressing the up or down arrows of the navigation pad.
Then use the right side arrow for selecting the hour digits and set the time with the up and down
arrows of the navigation pad.
Finally, use again the right side arrow for selecting the minute digits. Use the up and down arrows
for increasing or decreasing the time. Press the « OK » button for validation and press again on
button 2 for validation of the day and hour.
Auto timer
Your steam generator can be weekly programmed to work on for a certain time at different time of
a day and any day of the week.
The following information will guide you on how to program your steam generator.
1. For entering the schedule menu, press both the
right and left side arrows simultaneously.

11 Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Use & Settings
2. The first day is illuminated : press the down arrow to select the
humidifier status.
: On
Mo Tu Fr Sa
We Th Su
10:00 to 15:00
Th 15:12
Auto timer setting
Day
Steam unit status
Working period time
3. The status line is illuminated : press the left or right arrow for setting
the humidifier on on or off position.
4. Press the down arrow for setting the working time.
5. The working time is now illuminated : press the « OK » button.
6. For setting the period of time, press the up or down arrow.
7. For selecting the minutes, press the right side arrow.
8. For setting the minutes, press the up or down arrow.
9. Once the working time has been set, press the « OK » button and then
press the down arrow. The working time is no longer illuminated. You
can now set the working time for the following day by pressing the right
side arrow.
10. Process the same way as above for programming the other days.
11.Press Button 2 to exit the program.
2
ou
ou
ou

12 Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Use & Settings
Temperature setting point
Menu scrolling
Number of lamps
Perfume intensity
22°C
Mo 09:00
45°C - +
or
or
22°C
Mo 09:00
1
22°C
Mo 09:00
- +
Music on or off
22°C
Mo 09:00
Off
o
u
or
or or

13 Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Use & Settings
Option 1 setting
22°C
Mo 09:00
Off
Opt 1
Option 2 setting
22°C
Mo 09:00
Off
Opt 2
Option 3 setting
22°C
Mo 09:00
Off
Opt 3
Remote control nb
(if several remote controls)
22°C
Mo 09:00
1
Unit n°
or or
or or

14 Pictures for illustrating purposes only
Rue Feu St Eloi
76550 Ambrumesnil - France
Export Division: tel. +33 (0)2 35 83 06 44 ou +33 (0)2 35 83 03 86
fax. +33 (0)2 35 85 36 72
devatec reserves the right to change specifications or design of the equipment described in this borchure
without prior notice.
LR 94104-2
Other manuals for ElectroVap MC2 Series
1
Table of contents