DeVillbiss Air Power Company DAD-504 User manual

Risk of explosion or fire.
Improper use can cause
personal injury.
•This product is designed and in-
tended for use in industrial com-
pressed air systems only. Do not use
for liquids or gasses other than air.
•Do not use where pressure or tem-
perature can exceed rated operating
conditions (see specifications).
•Regulated outlet pressure must
never be set higher than the maxi-
mum operating pressure of the
downstream air tool or equipment.
An outlet pressure gauge should
always be used.
Risk of illness or death. Carbon mon-
oxide can cause nausea, fainting or
death. Stop using if carbon monox-
ide is present. This unit does not
remove carbon monoxide. A carbon
monoxide monitor should be incor-
porated into your air supply line
to warn of the presence of carbon
monoxide.
Risk of injury. Do not place unit in
service without metal bowl guard
installed. Filter units are sold only
with metal bowl guards. To mini-
mize the danger of flying fragments
in the event of plastic bowl failure,
guard must not be removed. If the
unit is in service without the metal
bowl guard installed, manufacturer’s
warranties are void and the manu-
facturer assumes no responsibility
for any resulting loss. If unit has
been in service and does not have a
metal bowl guard, order one and
install before placing back in service.
Certain compressor oils, cleaning
agents and solvents may attack the
plastic and rubber components used
in the construction of this product.
This product should not be used in
conjunciton with or in the vicinity of
these materials. Read and follow
material labels carefully. Please con-
sult DeVilbiss if in doubt.
SB-6-176
SERVICE BULLETIN
DAD-504 (13-0096) BREATHABLE AIR RETRO FIT KIT
IMPORTANT: Read and follow all IN-
STRUCTIONS and SAFETY PRECAU-
TIONS before installing, operating or main-
taining this equipment. Keep this manual
for future reference.
DESCRIPTION
The DAD-504 is designed to attach to an
existing DeVilbiss DAD-500 Desiccant Air
Dryer. The DAD-504 offers appropriate
filtration and a connection for the attach-
ment of a DeVilbiss Breathable Air Hose
and Air VizorTM supplied air breathing
system.
SPECIFICATIONS
Charcoal Filter:
Air Inlet 1/2" NPT(F)
Air Outlet 1/2" NPT(F)
Air Flow Capacity 75 CFM
Maximum Operating
Pressure 150 PSIG (10.3 Bar)
Maximum Temperature 150°F (65.6°C)
Manual Mechanical Drain Standard
Pressure Differential
Indicator Standard
Aerosol Filter .003 ppm./wt.
Particulate Filter 3.0 micron
Flow Thru Regulator:
Flow Thru Ports 1/2" NPT(F)
Regulated Ports 1/4" NPT(F)
Air Flow Capacity (regulated)
with 100 PSI Inlet 28 CFM @ 60 PSI
Maximum Inlet Pressure 300 PSIG
Regulated Pressure 0-125 PSIG
Maximum Temperature 175°F (79.4°C)
SAFETY PRECAUTIONS
This manual contains important information that all users must know and understand before using the equipment. This
information relates to USER SAFETY and PREVENTING EQUIPMENT PROBLEMS.
To help you recognize this information, we use the following terms to draw your attention to certain equipment labels and
portions of this manual. Please pay special attention to any label or information that is highlighted by one of these terms:
Note
Information that you should pay special
attention to.
Important information that tells how to
prevent damage to equipment, or how to
avoid a situation that might cause minor
injury.
Important information to alert you to a
situation that might cause serious injury
if instructions are not followed.

Page 2 SB-6-176
MAINTENANCE
Risk of injury. Components un-
der pressure. Relieve air pres-
sure before performing any
maintenance.
1. Check system at least once per shift
to insure proper drainage. Look for
water in the drain tubing.
2. Before performing maintenance on
system, close main shut-off valve
located upstream. Bleed off residual
air in system.
Figure 1 DAD-500 /DAD-504
Replace-
I
nd.
Ref.
ment
Parts
No. Part No. Description Req.
1HAF-517 Charcoal Filter 1
2SSP-456 Nipple 1
3HAR-508 Flow-Thru Regulator 1
4GA-316 Gauge 1
5MPV-424 Breathable Air Quick 1
Release Socket
PARTS LIST
INSTALLATION – RETRO FIT KIT
1. Be sure to read all "Cautions" and
"Warnings" in this manual and on the
unit before installation or using this
equipment.
2. This unit is designed to fit a DeVilbiss
DAD-500 desiccant air dryer. Installa-
tion on non-DeVilbiss desiccant dryers
is not recommended, as we cannot
assure the performance of those
devices.
3. Shut off the air supply to the DAD-500
and bleed air from the system.
4. Separate the air filter, coalescing filter
and nipple from the desiccant tank.
(This might be a good time to change
the desiccant beads, Part No. DAD-1).
5. Attach retro fit kit (DAD-504) to desic-
cant tank. Reattach air filter, coalesc-
ing filter and nipple to retro fit kit.
6. Position the filters in line with the des-
iccant tank, with the regulator gauge
facing straight forward.
Note
Use Teflon tape on pipe plug threads
and all threaded fittings to facilitate
removal in the future. Do not use
loctite or any material that may bond
and make removal difficult.
OPERATION
After the system is installed and ready
to use;
1. Attach breathable air hose to Q.D. on
flow-thru regulator.
2. Attach air hose(s) to outlet valve.
3. Open main shut-off valve upstream of
system.
1
2
5
Existing DAD-500
Existing DAD-500
4
Existing DAD-500 DAD-504
WITH RETRO FIT KIT
4. Attach breathable air hose to supplied
air respirator.
5. Adjust regulator (3) to read 60 PSIG
(flowing air to the visor). The pressure
should never be allowed to drop below
50 PSI in a flowing condition.
3

SB-6-176 Page 3
MAINTENANCE – FLOW-THRU
REGULATOR
Do not submerge regulator or
components in solvent or use
solvent to clean regulator parts.
Damage may occur to regulator
and components. Use a cloth
dampened in warm, soapy wa-
ter to clean exterior of regulator.
Note
This unit may be serviced with-
out removing the unit from the
compressed air line.
1. Frequency of servicing depends largely
on the condition of the compressed air
system and the degree of contamina-
tion in the system.
2. Before attempting to service this
product in-line, depressurize both
the upstream and downstream sides
of regulator.
3. Remove the bottom plug, valve spring
and valve assembly. Inspect all seals
and components for damage and re-
place as required. Clean seals and
components with mild detergent and
water. Use a clean, dry cloth to wipe
any contamination from valve seal
inside the body. Lubricate the valve
stem and lower valve "O"ring seal
with a light coat of MAGNALUBE-G
Figure 3 – HAR-508 Regulator
MAINTENANCE – HAF-517
CHARCOAL FILTER
1. Before performing maintenance on
unit, close any main shut-off valve
located upstream of filter. Bleed off
residual air in unit.
2. To open filter, press button located
on clamp ring and rotate ring either
clockwise or counterclockwise while
pulling down on ring. The metal bowl
guard and plastic bowl can then be
removed from the filter body.
3. Remove the filter element by loosen-
ing counterclockwise. Clean or replace
the filter element. Replace the char-
coal element when it no longer re-
moves oil vapor odors or when the
red indicator is visible.
4. Inspect "O"ring for damage. Replace
if necessary.
5. Inspect plastic bowl for signs of dam-
age such as cracks, crazing or deterio-
ration. Replace if necessary.
HAF-517 Parts List
Replace- Ind.
Ref. ment Parts
No. Part No. Description Req.
1HAF-404 Filter Change Ind. 1
(Not shown)
1A --- Body 1
2 --- O-Ring 1
3HAF-36 Filter Element and 1
O-Ring Kit
4HAF-11 Manual Drain 1
5HAF-8 Plastic Bowl 1
6HAF-19 Metal Bowl Guard 1
7HAF-409 Clamp Ring 1
Figure 2 – HAF-517
1 (not shown)
5
6
7
1A
3
2
4
or similar lubricant. Reassemble.
Bottom plug torque should not exceed
25 in./lbs.(2.8 N-m).
4. To replace main spring or diaphragm,
turn adjusting knob counterclockwise
to remove all spring force, then re-
move bonnet. Remove the adjusting
screw assembly, main spring, slip ring
and diaphragm assembly. Inspect the
diaphragm and the relief seat for dam-
age and contamination. Replace dia-
phragm assembly if necessary. Clean
the relief seat with a soft dry cloth.
Reassemble in reverse order making
sure the slip ring is properly posi-
tioned on top of the diaphragm.
Bonnet torque should not exceed
120 in./lbs. (13.6 N-m).
5. Before returning unit to service, en-
sure that all seals have been properly
reinstalled or replaced and compo-
nents requiring torque values have
been properly set.
6. If regulated pressure begins to creep
(an uncontrolled rise in regulated
pressure), it will most likely be caused
by contamination on the valve seat.
7. If the unit leaks from the vent holes in
the bonnet, it may be caused by con-
tamination, deterioration or damage
to the valve seat or diaphragm relief
seat. Replace any damaged or worn
components.
Knob
*Adjusting
Screw
Assembly
*KK-5045
Diaphragm
Repair Kit
Body
Cover
Panel
Nut
Bonnet
*Thrust
Washer
*Main
Spring
*Slip
Ring
*Diaphragm
Assembly
*Valve
Assembly
*Valve
Spring
*Bottom
Plug
O-Ring
Bottom
Plug
Body
Assembly

Page 4 SB-6-176
MAINTENANCE – DESICCANT DAD-1
1. Replace the desiccant when the hu-
midity indicator changes to a pink
color. Remove the pipe plug at the
bottom of the tank. Allow the mate-
rial to drain into a two (2) gallon or
larger container.
2. Once all the material has been re-
moved, replace the pipe plug (see
"Note" following) and tighten securely
(air tight).
Note
Use Teflon tape on pipe plug
threads and all threaded fittings
to facilitate removal in the fu-
ture. Do not use loctite or any
material that may bond and make
removal difficult.
WARRANTY
This product is covered by DeVilbiss' 1 Year Limited Warranty. See SB-1-000 which is
available upon request.
3. Replace the DAD-3 humidity indica-
tor paper (supplied with DAD-1 Des-
iccant) by removing the DAD-400
humidity indicator. Pry out the old
paper and push in the new paper
(printed side facing away from the
glass).
4. Remove the pipe plug on top of the
unit.
5. Using a funnel (suppplied with desic-
cant), fill the unit using DeVilbiss
Desiccant Material Part No. DAD-1
(19-0831) until full.
6. Replace the pipe plug (see "Note"
above) and tighten until air tight.
7. The humidity indicator will return to
a blue color within five minutes.
8. The desiccant material should be dis-
posed of properly.
9. Refer to the appropriate service
bulletin for checking the filters and
components.
Note
A desiccant Tune-Up Kit Part No.
DAD-600, is available. Contains the
following parts to completely
recondition a desiccant air station:
Part No. Description Qty.
Supplied
DAD-1 Desiccant 1
DAD-3 Humidity Indicator 1
HAF-6 #1 Filter Element 1
and O-Ring
HAF-507 Whirlwind Filter 1
DEVILBISS WORLDWIDE SALES AND SERVICE LISTING - www.devilbiss.com
INDUSTRIAL FINISHING
DeVilbiss has authorized distributors throughout the world. FOR TECHNICAL ASSISTANCE OR THE DISTRIBUTOR NEAREST YOU,
CALL TOLL FREE 1-888-992-4657 (U.S. AND CANADA ONLY). FOR LOCAL CALLS, SEE LISTING BELOW.
U.S./Canada Sales & Customer Service Office Address Telephone No.
Glendale Heights, IL 60139 195 Internationale Blvd. (630) 237-5000
Toll Free Fax No. 1-877-790-6965
AUTOMOTIVE FINISHING
DeVilbiss has authorized distributors throughout the world. For equipment, parts and service, check the Yellow Pages under "Auto-
mobile Body Shop Equipment and Supplies". FOR TECHNICAL ASSISTANCE OR THE DISTRIBUTOR NEAREST YOU, CALL TOLL
FREE 1-800-445-3988 (U.S. ONLY). FOR LOCAL CALLS, SEE LISTING BELOW.
U.S. Customer Service Office Address Telephone No.
Maumee, OH 43537 1724 Indian Wood Circle General Inquiry (419) 891-8100
Toll Free Fax No. 1-800-445-6643
2/01 ©Copyright 2001, DeVilbiss Printed in U.S.A.
This manual suits for next models
1
Popular Water Filtration System manuals by other brands

Atlantic Ultraviolet
Atlantic Ultraviolet Mighty Pure MP16A owner's manual

SunSun
SunSun CBG-500 Operation manual

Hayward
Hayward XStream Filtration Series owner's manual

Contech
Contech DownSpout StormFilter Operation and maintenance

Teka
Teka Airfilter MINI operating instructions

Wisy
Wisy LineAir 100 Installation and operating instructions

Schaffner
Schaffner Ecosine FN3446 Series User and installation manual

Pentair
Pentair FLECK 4600 SXT Installer manual

H2O International
H2O International H20-500 product manual

Renkforce
Renkforce 2306241 operating instructions

Neo-Pure
Neo-Pure TL3-A502 manual

STA-RITE