Dewetron DEWE-50-USB2-16-NI Product manual

Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H.
This document contains information which is protected by copyright. All rights are reserved. Reproduction,
adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws.
All trademarks and registered trademarks are acknowledged to be the property of their owners.

3
DE-M071203E • DEWE-50-USB2-16-NI • Technical Reference Manual • Printing version 1.0.0 • Dec. 17, 2007
Technical Reference
Content
General Information, Safety Instructions 5
Warranty Information ……………………………………………………………………… 5
Support ……………………………………………………………………………………… 5
Printing History……………………………………………………………………………… 5
Safety symbols in the manual …………………………………………………………… 6
Safety instructions for all DEWETRON systems ……………………………………… 7
Environmental Considerations …………………………………………………………… 8
Main System 9
DEWE-50-USB2-16-NI …………………………………………………………………… 9
System specications ……………………………………………………………………… 9
A/D & D/A Conversion A1
Internal Wiring B1
Declaration of conformity C1

4
Technical Reference

5
DE-M071203E • DEWE-50-USB2-16-NI • Technical Reference Manual • Printing version 1.0.0 • Dec. 17, 2007
The information contained in this document is subject to change without notice.
DEWETRON elektronische Messgeraete Ges.m.b.H. (DEWETRON) shall not be liable for any errors
contained in this document. DEWETRON MAKES NO WARRANTIES OF ANY KIND WITH REGARD
TO THIS DOCUMENT, WHETHER EXPRESS OR IMPLIED. DEWETRON SPECIFICALLY DISCLAIMS
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
DEWETRON shall not be liable for any direct, indirect, special, incidental, or consequential damages,
whether based on contract, tort, or any other legal theory, in connection with the furnishing of this document
or the use of the information in this document.
Warranty Information
A copy of the specic warranty terms applicable to your DEWETRON product and replacement parts can be
obtained from your local sales and service ofce.
Support
For any support please contact your local distributor rst or DEWETRON directly.
For Asia and Europe, please contact: For the Americas, please contact:
DEWETRON Ges.m.b.H.
Parkring 4
A-8074 Graz-Grambach
AUSTRIA
Tel.: +43 316 3070
Fax: +43 316 307090
Email: [email protected]
Web: http://www.dewamerica.com
The telephone hotline is available The telephone hotline is available
Monday to Friday between Monday to Friday between
08:00 and 17:00 CET (GMT +1:00) 08:00 and 17:00 GST (GMT -5:00)
Restricted Rights Legend
Use austrian law for duplication or disclosure.
DEWETRON GesmbH
Parkring 4
A-8074 Graz-Grambach / Austria
Printing History
Please refer to the page bottom for printing version.
Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H.
This document contains information which is protected by copyright. All rights are reserved. Reproduction,
adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright
laws.
All trademarks and registered trademarks are acknowledged to be the property of their owners.
Notice
General Information, Safety Instructions
DEWETRON, Inc.
10 High Street, Suite K
Wakeeld, RI 02879
U.S.A.
Tel.: +1 401 284 3750
Toll-free: +1 877 431 5166
Fax: +1 401 284 3755

6
Safety symbols in the manual
Indicates hazardous voltages.
WARNING Calls attention to a procedure, practice, or condition that could cause bodily
injury or death.
CAUTION Calls attention to a procedure, practice, or condition that could possibly cause
damage to equipment or permanent loss of data.
WARNINGS
The following general safety precautions must be observed during all phases of operation, service, and
repair of this product. Failure to comply with these precautions or with specic warnings elsewhere in this
manual violates safety standards of design, manufacture, and intended use of the product. DEWETRON
Elektronische Messgeraete Ges.m.b.H. assumes no liability for the customer’s failure to comply with these
requirements.
All accessories shown in this document are available as option
and will not be shipped as standard parts.
For safety reasons max. 50 V may be applied to the BNC input-connectors!
Refer to the regulation of maximum allowable touch potential.
Safety instructions

7
DE-M071203E • DEWE-50-USB2-16-NI • Technical Reference Manual • Printing version 1.0.0 • Dec. 17, 2007
Safety instructions for all DEWETRON systems
The DEWETRON data acquisition systems may only be installed by experts.
Read your manual before operating the system.
Observe local laws when using the instrument.
Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth terminal),
a non interruptible safety earth ground must be provided from the mains power source to the product
input wiring terminals or supplied power cable.
DO NOT operate the product in an explosive atmosphere or in the presence of ammable gases or
fumes and do not bring the system in contact with water.
DO NOT operate damaged equipment: Whenever it is possible that the safety protection features built
into this product have been impaired, either through physical damage, excessive moisture, or any
other reason, REMOVE POWER and do not use the product until safe operation can be veried by
service-trained personnel. If necessary, return the product to a DEWETRON sales and service ofce
for service and repair to ensure that safety features are maintained.
Keep away from live circuits: Operating personnel must not remove equipment covers or shields.
Procedures involving the removal of covers or shields are for use by service-trained personnel only.
Under certain conditions, dangerous voltages may exist even with the equipment switched off. To
avoid dangerous electrical shock, DO NOT perform procedures involving cover or shield removal
unless you are qualied to do so.
No modications are allowed at the instrument. The fuse in the power module has to be replaced by
the same type. For continued protection against re, replace the line fuse(s) only with fuse(s) of the
same voltage and current rating and type. DO NOT use repaired fuses or short-circuited fuse holder
labels and print on the power module may not be removed.
DO NOT service or adjust alone. Do not attempt internal service or adjustment unless another person,
capable of rendering rst aid and resuscitation, is present.
DO NOT substitute parts or modify equipment: Because of the danger of introducing additional
hazards, do not install substitute parts or perform any unauthorized modication to the product. Return
the product to a DEWETRON sales and service ofce for service and repair to ensure that safety
features are maintained.
Before opening the instrument (experts only) or exchanging the fuse in the power module disconnect
power!
Don’t touch internal wiring!
Don’t use higher supply voltage than specied and take care of the correct polarity, otherwise the
system will be damaged!
Use only original plugs and cables for harnessing.
Install ller-panels in unused slots.
The power-cable and -connector serve as Power-Breaker. The cable must not exceed 10 feet,
disconnect function must be possible without tools.
Keep the ventilation slots free and check them frequently to avoid an overheating of the system. The
cleaning interval of the lter pads depends on the environmental conditions.
Safety of the operator and the unit depend on following these rules.
DEWETRON is not responsible for any damage or injury that could result from improper connection or
misuse!
Safety instructions

8
CAUTION
The system BIOS is protected by password. Any change in the BIOS may cause a system crash.
When the system is booting, do not press ESC-button on keyboard. This may clear the BIOS settings
and cause system faults.
Any change in the le structure as deleting or adding les or directories might cause a system crash.
Before installing software updates contact DEWETRON or your local distributor. Use only software
packages which are released by DEWETRON. Further informations are also available in the internet
(http://www.dewetron.com).
After power off the system wait at least 10 seconds before switching the system on again. Otherwise
the system may not boot correct. This prolongs also the life of all system components.
General Information
Environmental Considerations
Information about the environmental impact of the product.
Product End-of-Life Handling
Observe the following guidelines when recycling a DEWETRON system:
System and Components Recycling
Production of these components required the extraction and use of natural resources. The substances
contained in the system could be harmful to your health and to the environment if the system is improperly
handled at it's end of life! Please recycle this product in an appropriate way to avoid an unnecessary pollution
of the environment and to keep natural resources.
This symbol indicates that this system complies with the European Union’s requirements
according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE).
Please nd further informations about recycling on the DEWETRON web site
www.dewetron.com
Restriction of Hazardous Substances
This product has been classied as Monitoring and Control equipment, and is outside the scope of the
2002/95/EC RoHS Directive. This product is known to contain lead.

9
253 mm
438,5 mm
132,5 mm3,3
Main System
DE-M071203E • DEWE-50-USB2-16-NI • Technical Reference Manual • Printing version 1.0.0 • Dec. 17, 2007
System specications
DEWE-50-USB2-16-NI
16 slot signal conditioning with system isolation
(in conjunction with DEWE-DAQ modules)
A/D converter specs: see appendix A
Wiring to A/D converter: see appendix B
DEWE-50-xx
A/D converter interface:
�USB 2.0�USB 1.x
�IEEE 1394 (FireWire
®
)
Power supply:
�230 V
AC
�115 / 230 V
AC
(switchable)
�100 to 250 V
AC
�9 to 40 V
DC
�10 to 32 V
DC
with UPS battery and external 115 / 230 V
AC
power supply
RS232 / 485 interface:
�yes
�no
Motherboard:
�DAQ-MOTH-16-DE-x �5 V �10 V
�DAQ-MOTH-16-NI-x-x �5 V �10 V �USB interface on-board
Operating temperature: 0 °C to 50 °C (standard)
Storage temperature: -20 °C to +60 °C
Humidity (operating): 10 % to 80 %, non condensing
5 % to 95 %, rel. humidity
Vibration: MIL-STD 810F 514.5 procedure I
operating test procedure
frequency range: 5 to 200 to 5 Hz; 5 x 12 min each direction
displacement amplitude ±3.5 mm (5 to 8.45 Hz)
acceleration amplitude 1 g (8.45 to 92 Hz)
displacement amplitude 92 to 113 Hz: ±0.029 mm
acceleration amplitude 1.5 g (113 to 200 Hz)
Shock: MIL-STD 810F 516.5 procedure I
non operating test procedure
½ sinus 11 ms 10 g, 3 shocks positive, 3 shocks negative
Dimensions (W x D x H):approx. 438 x 253 x 133 mm (17.2 x 10 x 5.2 in.)
with 50-MK option(3U 19" mountingrack): 513 x 256 x 133 (20.2 x 10.1 x 5.2 in.)
Weight:
typ. 5.5 kg (7 lbs), depending on configuration
Dimensions*
* Dimensions in mm
(1 inch = 25.4 mm)
Main System

10
Main System

A1
DE-M071203E • DEWE-50-USB2-16-NI • Technical Reference Manual • Printing version 1.0.0 • Dec. 17, 2007
A/D & D/A Conversion
A/D Conversion
Detailed information about the A/D card are not included in this manual.
For detailed information see the manufacturer’s A/D card manual.
D/A Conversion
Detailed information about the D/A card are not included in this manual.
For detailed information see the manufacturer’s D/A card manual.
A/D & D/A Conversion

A2
A/D & D/A Conversion
Notes

B1
12345
6789
W2 W3
W4
W6
W7 W1
W8
W9
W10
W11
W5
W1
W2
W3
W4
W5
W6
W7
W8
W9
W10
W11
CH 1
CH 2
CH 3
CH 4
CH 5
CH 6
CH 7
CH 8
CH 9
CH 10
CH 11
CH 12
CH 13
CH 14
CH 15
USB
DM
DP
GNDC
RX
TX
RS-485
GNDC
B
B
A
A
POWER
+V
+12 V
GNDP
-12 V
-V
A (RS-485)
GNDC
B (RS-485)
GNDP
+V
+12 V
-12 V
-V
GNDC
GNDC
TX
RX
GND
POWER RS-485 RS-232 RES
GND
Indicator
+9 V
-9 V
CH 0
GND
DE-M071203E • DEWE-50-USB2-16-NI • Technical Reference Manual • Printing version 1.0.0 • Dec. 17, 2007
Internal Wiring
16 slot DEWE-MOTHERBOARD DAQ-MOTH-16-DE-x
Internal Wiring
Front viewRear view
9-pin SUB-D pin assignment:
1 Module input (±5 V)
2 RS-485 (A)
3 RS-485 (B)
4 GND
5 +9 V power supply
6 +12 V power (default) /
+V sensor supply
7 Module output
(from A/D board)
8 -V sensor supply
9 -9 V power supply
The 16 slot DEWE-MOTHERBOARD receives the ±12 VDC power supply via a DC/DC converter from the
internal power supply.
5 V ORION
Ext. CLK
Ext. TRIG
DGND ORION
Ext. CLK 2 OUT
Ext. CLK 1 OUT (CAMERA TRIGGER)
DGND ORION
16x GND
16 x analog OUT (resistance 50 Ohm)
GND
+15 V ORION
-15 V ORION
16 channels single ended
analog output
(output resistance 15 Ohm)
Please nd the pin-assignment
on the next page!
5 = 5 V output; 330 kHz lter
10 = 10 V output; 330 kHz lter
Terminate RS-485
Connect GND to GNDP
Connect +12 V to +V (pin 6)
Terminate RS-485
Connect chassis to GND
Connect chassis to GND
Connect chassis to GND
Activate ORION RS-485 (A)
Activate ORION RS-485 (B)
Activate analog output 0 on CH 14
Activate analog output 1 on CH 15
Note: If you connect signals to these
contacts you have to open the solder
jumpers W10 and W11 rst!
Connection to CH14 (pin 7)
Connection to CH15 (pin 7)

B2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
-15 V
AGND
AGND
CH15+
CH14+
CH13+
CH12+
CH11+
CH10+
CH9+
CH8+
CH7+
CH6+
CH5+
CH4+
CH3+
CH2+
CH1+
CH0+
AGND
DI0/Source(0)
DI1/Gate(0)
DI2/AUX_U_D(0)
DI3/Source(1)
DI4/Gate(1)
DI5/AUX_U_D(1)
RS-485A
RS-485B
DI 6
DI 7
EXT_CLK
EXT_Trigger
EXT_CLK1
EXT_CLK2
+15 V
AGND
AGND
AGND
AGND
AGND
AGND
AGND
AGND
AGND
AISENSE2
AGND
AGND
AGND
AGND
AGND
AGND
AGND
AISENSE1
AGND
DI8/DO0
DI9/DO1
DI10/DO2
DI11/DO3
DI12/DO4
DI13/DO5
DI14/DO6
DI15/DO7
+5 V
DGND
DGND
+5 V
DGND
DGND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
-15 V
AGND
CH. 15+
AGND
NC.
RES.*
EXT-TRIGGER
SAMPLE CLOCK
* DONT CONNECT
AGND
CH. 14+
CH. 13+
CH. 12+
CH. 11+
CH. 10+
CH. 9+
CH. 8+
CH. 7+
CH. 6+
CH. 5+
CH. 4+
CH. 3+
CH. 2+
CH. 1+
CH. 0+
NC.
NC.
NC.
NC.
NC.
RES.*
RES.*
RES.*
RES.*
NC.
+15V
AGND
CH. 15-
CH. 14-
CH. 13-
CH. 12-
CH. 11-
CH. 10-
CH. 9-
CH. 8-
CH. 7-
CH. 6-
CH. 5-
CH. 4-
CH. 3-
CH. 2-
CH. 1-
CH. 0-
AGND
NC.
NC.
NC.
NC.
NC.
NC.
NC.
DGND
DGND
+5 V
DGND
GND
AGND
NC.
+5 V
D
W7 W1
W1
W2
W3
W4
W5
W6
W7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
PFI 14/P2.6
PFI 112/P2.4
PFI 9/P2.1
DGND
PFI 6/P1.6
PFI 5/P1.5
DGND
+5 V
DGND
PFI 1/P1.1
PFI 0/P1.0
DGND
DGND
+5 V
DGND
P0.6
P0.1
DGND
P0.4
APFI 0
AO 1
AO 0
AI 15
AI GND
AI 6
AI 13
AI GND
AI 4
AI GND
AI 3
AI 10
AI GND
AI 1
AI 8
DGND
DGND
PFI 8/P2.0
PFI 7/P1.7
PFI 15/P2.7
PFI 13/P2.5
PFI 4/P1.4
PFI 3/P1.3
PFI 2/P1.2
DGND
PFI 10/P2.2
PFI 11/P2.3
P0.3
P0.7
P0.2
DGND
P0.5
P0.0
DGND
AO GND
AO GND
AI GND
AI 7
AI 14
AI GND
AI 5
AI 12
AI Sense
AI 11
AI GND
AI 2
AI 9
AI GND
AI 0
GND
DGND
Analog OUT Ch. 1
Analog OUT Ch. 0
Internal Wiring
Analog output connector pin-assignment
68-pin high density connector 68-pin high density connector
Connector for DEWE-ORION-1616 cards Connector for DEWE-ORION-1624 cards
Rear view DGND
16 channels single ended
analog output
(output resistance 15 Ohm)
Please nd the pin-assignment
on the next page!
Terminate RS-485
Connect GND to GNDP
Connect +12 V to +V (pin 6)
Terminate RS-485
Connect chassis to GND
Connect chassis to GND
Connect chassis to GND
68-pin high density connector
Connector for National InstrumentsTM A/D cards
16 slot DEWE-MOTHERBOARD DAQ-MOTH-16-NI-x-U
5 = 5 V output; 330 kHz lter
10 = 10 V output; 330 kHz lter
USB interface on-board

C1
L
E
V
M
C
Dipl.-Ing. Roland Jeutter / Managing director
Manufacturer:
Address:
Name of product:
Kind of product:
CE-Certicate of conformity
Graz, October 14, 2008
Place / Date of the CE-marking
DEWETRON Elektronische Messgeraete Ges.m.b.H.
Parkring 4
A-8074 Graz-Grambach Austria
Tel.: +43 316 3070 0
Fax: +43 316 3070 90
e-mail: [email protected]
http://www.dewetron.com
DEWE-50-USB2-16-NI
Data acquisition instrument
The product meets the regulations of the following EC-directives:
73/23/EEC
"Directive on the approximation of the laws of the Member States relating to
electrical equipment designed for use within certain voltage limits amended by
the directive 93/68/EEC"
89/336/EEC
"Directive on the approximation of the laws of the Member States relating to
electromagnetic compatibility amended by the directives 91/263/EEC, 92/31/
EEC, 93/68/EEC and 93/97/EEC
The accordance is proved by the observance of the following standards:
Safety
Emissions
Immunity
IEC/EN 61010-1:1992/93 IEC 61010-1:1992/300 V CATIII Pol. D. 2
IEC/EN 61010-2-031 IEC 1010-2-031
EN 61000-6-4 EN 55011 Class B
EN 61000-6-2 Group standard
CE-Certicate of conformity

C2
Notes
Table of contents
Popular Industrial Electrical manuals by other brands

Murata
Murata GRM31MR72A683KA01 Series Reference sheet

Murata
Murata GRM0225C1E3R4CA03 Series Reference sheet

OEZ
OEZ CS-BH-JX75 Instructions for use

Vahle
Vahle SLS Translation of the original operating instructions

Murata
Murata GRM0335C1E3R0BA01 Series Reference sheet

Murata
Murata GRM0225C1C150JD05 Series Reference sheet