Dexing Fiber Labs NDS3542D User manual

NDS3542D Multi-input Modulator
User’s Manual
Web-NMS Version: 1.08 Build 100 Nov 4 2015
Software: 1.30
Hardware:1.04
Chengdu Dexin Digital Technology Co., Ltd.
WWW.KONTURM.RU

DIRECTORY
Chapter 1 Product Outline................................................................................1
1.1 Outline...................................................................................................................1
1.2 Features .................................................................................................................1
1.3 Principle Chart........................................................................................................2
1.4 Technical Specifications ..........................................................................................2
1.5 Appearance and description......................................................................................3
Chapter 2 Installation Guide.............................................................................5
2.1 Acquisition Check................................................................................................... 5
2.2 Installation Preparation ............................................................................................5
2.3 Wire’s Connection ..................................................................................................7
2.4 Signal Cable Connection..........................................................................................8
Chapter 3 Operation.........................................................................................9
3.1 LCD Menu Tree....................................................................................................10
3.2 General Setting .....................................................................................................13
Chapter 4 Web-based NMS Management........................................................27
4.1 login ....................................................................................................................27
4.2 Operation ............................................................................................................. 27
Chapter 5 Troubleshooting .............................................................................41
Chapter 6 Packing List ...................................................................................42
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
1
Chapter 1 Product Outline
1.1 Outline
NDS3542D multi-input modulator is DEXIN’s all-in-one device which integrates
demodulation, trans-mux and modulation in one case to convert signals into RF
output. It is a 1-U case which supports 4 tuner inputs to receive signal from satellite,
cable or terrestrial. To meet customers’ various requirements, NDS3542D is also
equipped with 2 ASI input, and output with 2 groups separate ASI ports and 4 MPTS
UDP IP port. The output modulated signals are to be received by TVs, STB and etc.
The USB port is designed to record encoded video (TS) and save it in ts files in the
USB Keys or Hard Disks, and then the ts files can be playback through the USB port.
The four CAMs/CIs accompanied and BISS modules can descramble the programs
input from 4 Tuner inputs. Its pluggable structure design greatly facilitates the
change of modules (demodulator) as needed.
1.2 Features
Support 4 DVB-C/T/T2/S/S2 Tuner and 2 ASI input ports
Support accurate PCR adjusting
Support PSI/SI editing and inserting
PID Remapping
Excellent RF output performance index, MER≥42db
4*DVB-C RF out
2 separate ASI&IP (4*MPTS over UDP) mirror 4 RF output
4 CAM decrypt multiple programs from 4 Tuner input
Support BISS descrambling
Record encoded TS and playback TS files (*.ts) through USB port
Support LCD display and keyboard
Support Web management, Updates via web and USB
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
1.3 Principle Chart
1.4 Technical Specifications
Input 4 S/S2 Tuner and 2 ASI input
Input Frequency 950-2150MHz
Symbol rate 1~45Mbauds
Signal Strength -65~-25dBm
DVB-S
FEC Demodulation 1/2, 2/3, 3/4, 5/6, 7/8 QPSK
Input Frequency 950-2150MHz
Symbol rate QPSK/8PSK: 1~45Mbauds
Code rate 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
Tuner
Section
DVB-S2
Demodulation Mode QPSK, 8PSK
Maximum PID
Remapping 128per input channel
PID remapping (automatically or manually)
Accurate PCR adjusting
Multiplexing
Function
Generate PSI/SI table automatically
Standard J.83A, J.83B, J.83C
MER ≥42dB
RF frequency 30~950MHz, 1KHz step
RF output level -30.0~ 0.0 dbm (77~107 dbµV), 0.1db
step
Symbol rate 2.5 – 4.66 Msps, 5.0 - 8.0 Msps
Constellation 16/32/64/128/256QAM
J.83A bandwidth 8M
Constellation 64QAM, 256QAM
J.83B bandwidth 6M
Constellation 64QAM, 256QAM
Modulation DVB-C
J.83C bandwidth 6M
2
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
Local interface LCD + control buttons
Remote
management Web NMS
2 ASI out(BNC type)
Stream Out IP (4*MPTS over UDP) out (RJ45, 1000M)
System
Upgrading Web and USB
Dimension 482mm×300mm×44.5mm(W*D*H)
Weight 3.7kg
Temperature 0~45℃(Operation) ; -20~80℃(Storage)
Power AC 100V±1050/60Hz; AC 220V±10%, 50/60HZ
General
Consumption 25W
1.5 Appearance and description
Front Panel Illustration:
1 LCD Display
2 Indicator Area
3 Control Buttons
4 DATA port
5 NMS port for network management connection
6 USB port for upgrade/record encoded TS/playback TS files
(*.ts).
Rear Panel Illustration:
3
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
4
1 Module 1: with 2 CAMs /Smart card slots and 2 RF signal input and
loop-through
2 Module 2: with 2 CAMs /Smart card slots and 2 RF signal input and
loop-through
3 2 separate ASI input Interface
4 2 separate groups of ASI output
5 RF out Interface
6 Power switch/Fuse/Socket
7 Grounding Wire
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
Chapter 2 Installation Guide
2.1 Acquisition Check
When user opens the package of the device, it is necessary to check items according to
packing list. Normally it should include the following items:
NDS3542D Multi-input Modulator 1pcs
User’sManual 1pcs
RF/Loopout Cables 4 PCs
ASICable 1pcs
PowerCord 1pcs
2.2 Installation Preparation
When users install device, please follow the below steps. The details of installation will
be described at the rest part of this chapter. Users can also refer rear panel chart during
the installation.
The main content of this chapter including:
Checking the possible device missing or damage during the transportation
Preparing relevant environment for installation
Installing modulator
Connecting signal cables
Connecting communication port (if it is necessary)
2.2.1 Device's Installation Flow Chart Illustrated as following:
5
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
6
2.2.2 Environment Requirement
Item Requirement
Machine Hall Space
When user installs machine frame array in one machine
hall, the distance between 2 rows of machine frames
should be 1.2~1.5m and the distance against wall should
be no less than 0.8m.
Machine Hall Floor
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material:
1X107~1X1010,Grounding current limiting resistance:
1M (Floor bearing should be greater than 450Kg/㎡)
Environment
Temperature
5~40℃(sustainable ),0~45℃(short time),
installing air-conditioning is recommended
Relative Humidity 20%~80% sustainable 10%~90% short time
Pressure 86~105KPa
Door & Window Installing rubber strip for sealing door-gaps and dual level
glasses for window
Wall It can be covered with wallpaper, or brightness less paint.
Fire Protection Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and
lighting power are independent to each other. Device
power requires AC power 100-240V 50-60Hz. Please
carefully check before running.
2.2.3 Grounding Requirement
All function modules’ good grounding is the basis of reliability and stability of
devices. Also, they are the most important guarantee of lightning arresting and
interference rejection. Therefore, the system must follow this rule.
Coaxial cables outer conductor and isolation layer should keep proper electric
conducting with the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
7
Users should make sure the 2 ends of grounding wire well electric conducted and be
antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should be no
less than 25mm2.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The grounding
wire should be as short as possible and avoid circling. The area of the conduction
between grounding wire and grounding strip should be no less than 25mm2.
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and the
power switch, fuse, power supply socket is just beside ,whose order goes like this, power
switch is on the left ,power supply socket is on the right and the fuse is just between
them.
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC
power.
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent
way, say, share the same ground with other devices. When the device adopts united
way, the grounding resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to NDS3542D Modulator, user should set the power
switch to “OFF”.
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
2.4 Signal Cable Connection
The signal connections include the connection of input signal cable and the connection of
output signal cable. The details are as follows:
NDS3542D Modulator Cable Illustration:
NMS Cable illustration (CAT5):
RF Input/Loop Cable Illustration:
ASI Input Cable Illustration:
8
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
9
Chapter 3 Operation
The front panel of NDS3542D is the user-operating interface and the equipment can be
easily operated and managed by user according to the procedures displayed on the LCD:
Keyboard Function Description:
MENU: Cancel current entered value, resume previous setting; Return to previous menu.
ENTER: Activate the parameters which need modifications, or confirm the change after
modification.
LEFT/RIGHT: Choose and set the parameters.
UP/DOWN: Modify activated parameter or paging up/down when parameter is
inactivated.
LOCK: Lock the screen/cancel the lock state. After pressing the lock key, the LCD will
display the current configuring state.
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
3.1 LCD Menu Tree
10
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
11
Main Menu:
TS Config
Channel A:
TSID
Channel A:
ONID
Channel A:
Output Mode
Channel A:
NIT Insert
TS Config:
Channel A
TS Config:
Channel D
Main Menu:
Modulator
Modulator:
Constellation
Modulator:
Symbol rate
Modulator:
Standard
Modulator:
RF ON
Modulator:
Bitrate
Standard (1/3)
►J.83A
Constellation(1/2)
►64QAM
Symbol rate
5310Ksps
RF On
Off *On
Bit Rate(act/max)
6.986M/31.668M
Modulator:
Channel A
Modulate setting:
Channel D (Same submenus with Channel A )
(Same submenus with Channel A )
Main Menu
CI Card
CI Card:
Card A
CI Card:
Card D
Card A:
Max Birate
Input TS Mode
Card Error Check
Parse Program
Descramble Program
Rom Version
Card Status
Descramble Error
(Same content with Card A above)
Main Menu:
BISS Descrambling
BISS A :
Input TS Mode
Word Mode
Burned Key
Descrambler Key
SK
TS Lock
Parse Program
Descramble Program
(Same content with BISS A above)
BISS Descrambling:
BISS A
BISS Descrambling:
BISS D
Modulator:
RF frequency
Modulator:
RF level
RF frequency
730MHz
RF level
-10.0 dBm
Channel A:
ASI 1 Out Select
Channel A:
ASI 2 Out Select
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
12
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
3.2 General Setting
Switch on the device and after a few seconds’ initialization, it presents start-up pictures as
below:
13
Dexin NDS3542D Modulator
Start OK…
Start up… A Bitrate xx.xxMbps
Indicate the Real-time output bitrate
of the 2 carriers, which shows in turn.
Press ‘LOCK’ key on the front panel to enter the main menu. The LCD will display the
following pages where user can configure the parameters for the device:
Main menu
Status
Input Sets
CI Card
BISS descrambling
TS config
Modulator
IP Stream
USB Device
Network
System
User could do all the settings according to the 8 directions displayed on the LCD. User
can press UP/DOWN buttons to specify menu item, and then press ENTER to enter the
submenus as below:
3.2.1 Status
Alarm
The alarm indicator will turn on if there is no A/V signals inputting or outputting bit rate
overflows. User then can enter this menu to check the error type. Otherwise it shows the
‘system run normal’.
Alarm
System run normal
Uptime
Press Enter to enter “Status” and it displays the working time duration of the device. It
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
times upon power on
14
3.2.2 Input Sets
NDS3542D supports 4 tuner inputs and 2 ASI input. Users can connect the signals to the
input interfaces and enter ‘Input Sets’ to configure the tuner and ASI input parameters. It
displays as below:
Tuner DVB S/S2 1~4
Press ENTER key to enter ‘Tuner DVB S2 1’ to configure tuner 1 input parameters, and
it displays as below. The setting principle for the 4 tuner is the same as ‘Tuner DVB S2
1’.
Tuner parameters: Users can enter this menu to configure the each parameter according
to your signal source to receive TS. (Make sure the responding RF cable is properly
connected.)
1: Tuner DVB S2 1
Tuner parameters
Mux program
Uptime
2 Days-10:30:20
Input Sets
1: Tuner DVB S2 1
2: Tuner DVB S2 2
T
o confi
g
ure 4 Tuner in
p
ut
3: Tuner DVB S2 3
4: Tuner DVB S2 4
5: ASI 1 To configure 2 ASI input
6: ASI 2
7: USB To configure USB input
Tuner parameters:
Satellite frequency
LNB frequency
Symbol rate
LNB voltage
22K
Signal Lock
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
Mux Program: Users can parse the Tuner input program list and select programs to mux
out via the 4 carriers in this menu.
For reading the input bitrate
of corresponding channel
15
ASI 1~2/USB
Press ENTER key to enter ‘ASI/USB’ to select ASI/USB input program(s) to mux out.
The setting principle for the 2 ASI and USB are the same.
The operation method is the same as described as tuner input above.
3.2.3 CI Card
NDS3542D supports 4 CI cards to descramble programs from Tuner input. One CI card
can be applied to descramble one Tuner input signal sources. Users can press ENTER key
to enter ‘CI Card’ to configure the 4 cards respectively.
TS Locked
Bitrate: 4.040 Mb
p
s
Searching Program
Get 4 Programs
For reading the number
of programs from
corresponding channel
Mux Program (0/4)
1:DTV X
Mux Program (0/4)
1:DTV [←]
Mux Program (0/4)
1:DTV [→]
Mux Program (1/4)
1:DTV √
Mux Program
TS Lock
Parse Program
Mux to channel A
A/B: Represent the 2 output carriers.
Process of selecting programs to output
through front panel:
[←]: to cancel program output;
[→]: to output the program
“√”: a symbol indicating the
corresponding program has been selected
to output;
“X”: a symbol indicating the corresponding
program has not been selected to output
Press ENTER key
Press RIGHT/LEFT
key to shift arrow
Press ENTER key to
confirm
Mux to channel D
To choose the
out
p
ut carrier
ASI/USB
TS Lock
Parse Program
Select Program A
Select Program B
Select Program C
Select Program D
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
CI Card
Card A
Card B
Card C
Card D
Press ENTER key to enter Card A (or Card B/C/D), the setting principle is the same.
Card A
Max Bitrate
Input TS Mode
16
Card Error Check
Parse Program
Descramble Program
Rom Version
Card Status
Descramble Error
Max Bit rate
CI Max Bitrate options range from 48-108Mbps. Move the triangle to select a value as
principle: Actual Input Bitrate≤Max Bitrate≤CI Max decrypting capacity
Max Bitrate(1/5)
►48 Mbps
Input TS Mode
One CI card can be applied to descramble Tuner 1 or Tuner 2 input signal sources. ‘Skip
CI card’ means to skip the card which is used for FTA stream.
Input TS Mode (1/2)
►Skip CI Card
Tuner 1
Tuner 2
Card Error Check
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
Users can decide whether to enable or disable the card error check function in this menu.
Card Error Check (1/2)
►Enable
Parse Program
Users can read the quantity of programs parsed from the de-scrambled channel.
Searching Program
Get 8 Programs
Descramble Program
Users can select program(s) from the searched out programs to descramble. The quantity
to be descrambled will depend on the CAM/CI performance you apply to.
►1 CETV 1 √
2
CCTV4A X
Rom Version/Card Status/Descramble Error
Users can read the other info about the CI card in the following menus.
Rom Version
X.X.X.X
Card Status
Normal
Descramble Error
Normal
3.2.4 BISS Descrambling
NDS3542D also supports BISS to descramble encrypted programs from Tuner input.
Users can enter 4 BISS descrambling to configure the 4 BISS respectively. One BISS can
be applied to descramble one corresponding Tuner input signal sources.
CI Card
BISS A
BISS B
BISS C
17
BISS D
WWW.KONTURM.RU

NDS3542D Multi-input Modulator User’s Manual
Press ENTER key to enter BISS A (or BISS B/C/D), the setting principle is the same:
BISS A
Input TS Mode
Word Mode
Burned Key
Descrambler Key
SK
TS Lock
Parse Program
Descramble Program
Input TS Mode
One BISS can be applied to descramble one corresponding Tuner input signal sources.
‘Skip BISS’ means to skip the card which is used for FTA stream.
Input TS Mode
►Skip BISS
Tuner 1
Word Mode / Burned Key /Descrambler Key/SK
Users need to input keys to descramble programs as per the BISS scrambling side which
usually is DVB-S/S2 modulator.
The descrambling principle is as following chart:
Modulating Side (BISS SCR) Receiving Side (BISS DESCR) Digit (0x----)
Mode 1+SW Data Mode 1+Descrambler Key 12
Mode E+ESW Data + Device Mode E + Descrambler Key + Burned Key 16
Mode E+ESW Data + Input ID Mode E + Descrambler Key + SK 14
TS Lock
Users can read the real-time bitrate of the corresponding channel.
TS Locked
Bitrate: 34.662 Mbps 18
WWW.KONTURM.RU
Table of contents
Other Dexing Modulator manuals
Popular Modulator manuals by other brands

Lumantek
Lumantek AMIGO User's operation manual

Blankom
Blankom STR 821 operating instructions

Fracarro
Fracarro Head Line SIG7280 operating instructions

Edision
Edision HDMI Modulator single DVB-T user manual

Philips
Philips SWS2104W Specifications