Dexing FiberLabs NDS3107C User manual

NDS3107C Multiplexer
User’s Manual
Dexin Digital Technology Corp. Ltd.

NDS3107C Multiplexer User Manual
DIRECTORY
CHAPTER 1 PRODUCT OUTLINE......................................................1
1.1 OUTLINE ...............................................................................................1
1.2 FEATURES.............................................................................................1
1.3 SPECIFICATIONS...............................................................................1
1.4 PRINCIPLE CHART...........................................................................2
1.5 APPEARANCE AND DESCRIPTION.............................................2
CHAPTER 2 INSTALLATION GUIDE.................................................4
2.1 ACQUISITION CHECK.....................................................................4
2.2 INSTALLATION PREPARATION...................................................4
2.3 WIRE’S CONNECTION.....................................................................6
2.4 SIGNAL CABLE CONNECTION....................................................6
CHAPTER 3 OPERATION.......................................................................8
3.1 LCD MENU............................................................................................8
3.2 INITIAL STATUS .................................................................................9
3.3 GENERAL SETTINGS........................................................................9
CHAPTER 4 WEB NMS OPERATION.............................................. 13
CHAPTER 5 TROUBLE SHOOTING................................................ 20
CHAPTER 6 PACKING LIST............................................................... 21

NDS3107C Multiplexer User Manual
1
Chapter 1 Product Outline
1.1 Outline
NDS3107Cmultiplexer is an enhanced TS re-multiplexer for digital TV broadcasting
head-end system. It can multiplex up to 8 ASI and 512 IP input and output TS through 2
groups of separate ASI output port and two GE port for two separate IP outputs. The
multiplexer has all the functions of normal TS multiplexer, including programs
multiplexing, PID re-mapping etc. Also the multiplexer can insert EPG (Electronic Program
Guide), and data casting information into each output stream. In conclusion, its high
integration and cost effective design make this device widely used in the CATV
Broadcasting system.
1.2 Features
Fully complying with ISO13818 and EN300 468 standard
Support 8 ASI input for re-multiplexing
Support 512 IP input through DATA1 and DATA2 over UDP protocol
Support accurate PCR adjusting/ PID re-mapping/PSI/SI rebuilding and editing
Two groups (each group has 2 channels)separate ASI outputs
IP (2 MPTS) over UDP, RTP/RTSP output as mirror of ASI output (RJ45), GE Port,
DATA1 and DATA 2
Huge buffer memory for saving the overflowing code stream
Support to multiplex one program to all outputs
LCD/keyboard and Web-based NMS management
1.3 Specifications
Input 8 ASI input+512 IP input DATA 1 and DATA 2 over UDP protocol
PID re-mapping
PCR accurate adjusting
Re-multiplex
PSI/SI (PAT, PMT) tables auto generation and edition
ASI 2 groups separate outputs (each group has 2
channels)
Output port
IP MPTS over UDP, RTP/RTSP output (RJ45),
1000Mbps Ethernet, DATA 1 and DATA 2
Output range 0x0000—0x1FFFPID
PID transparent Any PID transparent and mapping achievable

NDS3107C Multiplexer User Manual
Amount of output
PID 180
NMS port Ethernet port 10/100M/1000M self adaption
Dimensions 482mm×300mm×44mm (WxLxH)
Weight 3.5kg
Temperature 0~45℃(operation), -20~80℃(storage)
General
Power supply AC 110V±10%, 50/60Hz Or AC 220V±10%,
50/60Hz
1.4 Principle Chart
1.5 Appearance and Description
Front panel Illustration:
1 2 3 4 5 6
Indicator area: All the indicators will light on when NDS3107C multiplexer works at its current
mode.
1 LCD Display
Power Indicator
Alarm Indicator
2 ASI 1~ASI 8: when the input signal of ASI is locked, the light is green.
Otherwise it becomes red.
2

NDS3107C Multiplexer User Manual
3 UP/ DOWN /LEFT/RIGHT Key
4 Enter: Confirmation key
5 MENU Key
6 LOCK Key
Rear panel Illustration:
3
7 8 9 1011 12
7 ASI IN1~8: TS input
ASI OUT 1: TS output
ASI OUT 2: TS output ( as mirror of ASI 1)
ASI OUT 3: TS output
8
ASI OUT 4: TS output( as mirror of ASI 3)
9 NMS Ethernet Port ( 10/100/1000Mbps)
10 Data port: two Gigabits IP outputs port
11 Power switch, fuse, socket
12 Grounding pole

NDS3107C Multiplexer User Manual
Chapter 2 Installation Guide
2.1 Acquisition Check
When user opens the package of the device, it is necessary to check items according to packing
list. Normally it should include the following items:
NDS3107C Multiplexer
User’s Manual
ASI Cable
Power Cord
If any item is missing or mismatching with the list above, please contact local dealer.
2.2 Installation Preparation
When users install device, please follow the below steps. The details of installation will be
described at the rest part of this chapter. Users can also refer rear panel chart during the
installation.
The main content of this chapter includes:
Checking the possible device missing or damage during the transportation
Preparing relevant environment for installation
Installing multiplexer
Connecting signal cables
Connecting communication port (if it is necessary)
2.2.1 Device’s Installation Flow Chart Illustrated as following:
2.2.2 Environment Requirement
Item Requirement
Machine Hall Space When user installs machine frame array in one machine hall, the
distance between 2 rows of machine frames should be 1.2~1.5m
4

NDS3107C Multiplexer User Manual
5
and the distance against wall should be no less than 0.8m.
Machine Hall Floor
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material:
1X107~1X1010,Grounding current limiting resistance: 1M
(Floor bearing should be greater than 450Kg/㎡)
Environment
Temperature
5~40℃(sustainable ),0~45℃(short time),
installing air-conditioning is recommended
Relative Humidity 20%~80% sustainable 10%~90% short time
Pressure 86~105KPa
Door & Window Installing rubber strip for sealing door-gaps and dual level glasses
for window
Wall It can be covered with wallpaper, or brightness less paint.
Fire Protection Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and lighting
power are independent to each other. Device power requires AC
power 220V 50Hz. Please carefully check before running.
2.2.3 Grounding Requirement
All function modules’ good grounding is the basis of reliability and stability of devices. Also,
they are the most important guarantee of lightning arresting and interference rejection.
Therefore, the system must follow this rule.
ASI cable’s outer conductor and isolation layer should keep proper electric conducting with
the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.
Users should make sure the 2 ends of grounding wire well electric conducted and be antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should be no less
than 25mm2.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The grounding wire
should be as short as possible and avoid circling. The area of the conduction between grounding

NDS3107C Multiplexer User Manual
6
wire and grounding strip should be no less than 25mm2.
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and the power
switch, fuse, power supply socket is just beside ,whose order goes like this, power switch is on
the left ,power supply socket is on the right and the fuse is just between them.
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC power.
Connecting Grounding Wire
When the device is solely connected to protective ground, it should adopt independent way,
say, share the same ground with other devices. When the device adopts united way, the
grounding resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to NDS3107C multiplexer, user should set the power switch
to “OFF”.
2.4 Signal Cable Connection
The signal connections include the connection of input signal cable and the connection of
output signal cable. The details are as follows:
2.4.1 ASI In and ASI out connection:
ASI Input Connection
User can find ASI input port on the device according to connector mark described in the rear
panel illustration, and then connect the ASI cable (in the accessories). One end is connected to
the Multiplexer’s ASI input port, while the other end is connected to Encoder’s ASI output port
or ASI output port of other equipment.
ASI Output Connection

NDS3107C Multiplexer User Manual
User can find ASI output port on the device according to connector mark described in the rear
panel illustration, and then connect the ASI cable (in the accessories); one end is connected to the
Multiplexer’s ASI output port and the other end to the Modulator’s ASI input port or ASI input
of other equipment. Multiplexer’s ASI cable illustrated as follows:
2.4.2 Network cable (Category 5) illustration:
7

NDS3107C Multiplexer User Manual
Chapter 3 Operation
NDS3107C multiplexer’s front panel is user operation interface. The detailed operations go as
follows:
Keyboard Function Description:
MENU: Canceling presently entered value, resuming previous setting; Return to previous menu.
ENTER: Activating the parameters which need modifications, or confirming the change after
modification.
LEFT/RIGHT: To choose and set the parameters.
UP/DOWN: Modifying activated parameter or paging up/down when parameter is inactivated.
LOCK: Locking the screen / canceling the lock state. After pressing lock key, the system will
question the users to save present setting or not. If not, the LCD will display the current
configuration state.
At the page of 5.2 “Load default CFG”, user can firstly press “ENTER” key, consequently
system resumes factory parameter setting.
3.1 LCD Menu
An overview of the LCD menus:
Initializing
Current General
Working Status
1 Status 1.1 Uptime
2 TS Config 2.1 Out 1
PMT Interval
SDT Interval
SDT Insert
Packet Mode
Out Bit Rate
Original Net ID
Transport Stream
Same contents as Out 1
1.2 Alarm
2.1 Out 2
PAT Interval
8

NDS3107C Multiplexer User Manual
3.2 Initial Status
After powering on the device it will take a few seconds to initialize the system, and then the
LCD will show the device name and output valid and total bit-rate in the first row, while the 8
channels’ respective serial number, input real-time encoding bit-rate in the second row in turn.
It shows as below:
Dexin MUX3107C
P1:55.999Mbps P2:55.999Mbps
3.3 General Settings
By pressing LOCK key, users can enter in the main menu and set the input and output
parameters in the following editing interfaces, the LCD will display the following pages:
9

NDS3107C Multiplexer User Manual
►1.Status 2.TSconfig
3. IP output 4. Network Setting
►5.Configsetting 6.Version
7. Language
The option with “►” is the current selection, users can press the ENTER key to enter the
specified submenu to modify the parameters.
3.3.1 Run Status
Alarm status
The alarm indicator will turn on if there is no A/V signals inputting or outputting bit rate
overflows. User then can enter this menu to check the error type. Otherwise it shows the ‘No
warning’.
Alarm status
No warning
Up time
Press Enter to enter “Up time” and it displays the working time duration of the device. It times
upon power on.
Uptime
00:37:54 up
3.3.2 TS Config
NDS3107C is equipped with 2 groups of ASI output, each groups have 2 channels. Under this
menu, users can enter the corresponding channels to set the relevant ASI output parameters. The
setting principle is the same for out 1 and 2, so here this manual just takes one channel as the
example to explain. After pressing the enter key, the LCD will display the following pages:
2.2.3 SDT Interval 2.2.4 SDT Insert
2.2.1 PAT Interval 2.2.2 PMT Intervel
10

NDS3107C Multiplexer User Manual
2.2.5 Packet Mode 2.2.6 Out Bit rate
2.2.7 Original Net ID 2.2.8 Transport Stream ID
3.3.3 IP output
NDS3107C supports 2 MPTS output through Data1 and Data2, the setting principle is the same
for Data1 and Data2, so here this manual just takes Data1 setting as the example to explain. After
pressing the enter key, the LCD will display the following pages:
3.1 DATA1 3.2 DATA2
3.1.1 Output Protocol 3.1.2 MPTS1
3.1.3 MPTS2
3.1.1.1 Output Mode 3.1.1.2 Filter Null PKT
3.1.1.3 Reset IP Address 3.1.1.4 Destination Port
3.3.4 Network Setting
After enter Network Setting, users can set the parameters of NMS interface and DATA interface
parameters, the setting principle is the same for NMS interface and DATA interface, so here this
manual just takes one as the example to explain, and the submenus shows as the following LCD
displays.
192.168.000.136
Submask
255.255.255.000
IPAddr
DefaultGateway
000. 000.000.001
MACAddress
02:A1:A2:A3:A4:A5
3.3.5 Config Setting
11

NDS3107C Multiplexer User Manual
Save Config
Users can enter Saving Configuration submenu for saving settings. Choose yes and press
ENTER to confirm.
Save Configuration
►YES NO
Restore Configuration
At this menu, user can choose yes to restore the device into the last saved configuration.
Restore Configuration
►YES NO
Factory Set
Choose yes to restore the device into factory’s default configuration.
12
Reset Web Login Password
Choose yes to reset the web login password.
Version
User can check the software version and hardware version of this equipment under this
submenu.
Language
User can select the needed language under this submenu for the system:
SW:X.XX HW:X.X
ResetWebLoginPassword
►YES NO
►YES NO
Set Chinese/English
►YES NO
Factory Configuration

NDS3107C Multiplexer User Manual
Chapter 4 WEB NMS Operation
User not only can use front buttons to set configuration, but also can control and set the
configuration in computer by connecting the device to web NMS Port. User should ensure that
the computer’s IP address is different from this device IP address; otherwise, it would cause IP
conflict.
4.1 login
The default IP address of this device is 192.168.2.136. (We can modify the IP through the front
panel.)
Connect the PC (Personal Computer) and the device with net cable, and use ping command to
confirm they are on the same network segment.
I.G. the PC IP address is 192.168.99.252, we then change the device IP to 192.168.99.xxx (xxx
can be 0 to 255 except 252 to avoid IP conflict).
Use web browser to connect the device with PC by inputting the Encoder’s IP address in the
browser’s address bar and press Enter.
It will display the Login interface as Figure-1. Input the Username and Password (Both the
default Username and Password are “admin”.) and then click “LOGIN” to start the device
setting.
Figure-1
4.2 Operation
When we confirm the login, it displays the WELCOME interface as Figure-2.
13

NDS3107C Multiplexer User Manual
User can click any item here to enter the
corresponding interface to check
information or set the
p
arameters.
It automatically identifies and displays the
signal source interface and real-time bit
rate of corresponding input channel.
TS indicators—Green light indicates the
TS is normal, which otherwise turns to
red.
Figure-2
Input:
From the menu on left side of the webpage, clicking “Input”, it displays the interface where
users can configure the 512 IP input parameters of DATA 1 and DATA 2. (Figure-3)
Figure-3
Function→Mux:
From the menu on left side of the webpage, clicking “Mux”, it displays the interface where
users can choose the input programs to mux out separately. (Figure-4)
14

NDS3107C Multiplexer User Manual
Output channel select
Input channel select
Input Area Output Area
Operation Area
Figure-4
Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as
below:
: To automatically refresh the input and output program information
:Enable/disable the CA Filter function. Clicking the box, user can filter the input CA to
avoid disturbing with the device scrambling function.
: To enable/disable the PID remapping
To refresh the input program information
To refresh the output program information
Select one input program first and click this button to transfer the selected program
to the right box to output.
Similarly, user can cancel the multiplexed programs from the right box.
To parse programs time limitation of parsing input programs
Program Modification:
The multiplexed program information can be modified by clicking , it triggers a
dialog box (Figure-5) where users can input new information.
15

NDS3107C Multiplexer User Manual
Figure-5
Input new data and click ‘OK’ button at last to confirm the modification.
Function →TS Config:
Clicking “TS Config”, it displays the interface where users can configure the output TS.
(Figure-6)
Output channel select
Click this button to effect the
configurations at last.
Figure-6
Function →IP Output:
NDS3107C supports TS output in IP (2*MPTS) format through the DATA port. The 2*MPTS
mirror the two ASI output.
Click ‘IP Stream’, it displays the interface as Figure-7 where to set IP out parameters.
16

NDS3107C Multiplexer User Manual
Figure-7
System →IP Configuration:
Click ‘IP Configuration’, it displays the interface as Figure-8 where to set NMS and DATA port
parameters.
Figure-8
System →Upgrade:
Clicking “upgrade”, it displays the screen as Figure-9 where to update the device by using the
update file. After updating the device, user needs to restart the device by using Reboot option.
17

NDS3107C Multiplexer User Manual
Figure-9
System →Password:
Clicking “Password”, it displays the screen as Figure-10 where to set the login account and
password for the web NMS.
Figure-10
System →Log:
Clicking “Log”, it displays the screen as Figure-11 where to check the log of this device.
18