Page 1.2 POWER & SENSE MULTIPLEXER MODULE 40-658
pickering
SECTION 1 - TECHNICAL SPECIFICATION
Power & Sense MUX – 40-658
pickeringtest.com
Specifications
Switching Specification - Power MUX
Switch Type: Ruthenium Reed Relay
Max Switch Voltage: 200VDC/240VAC*
Max Switch Current:
Max Carry Current:
Max Switching Power:
1A
2A Continuous,
2.8A Peak (50% duty cycle)
40W
Initial On Path Resistance:
Off Path Resistance:
<250mΩ
>109Ω
Operating Time: 1ms typical,
500µs for multichannel mode
Expected Life, low power load:
Expected Life, full power load:
>108 operations
>106 operations
* For full voltage rating, signal sources to be switched must be fully
isolated from mains supply and safety earth.
Power Requirements
+3.3V +5V +12V -12V
0150mA 70mA 0
Operating/Storage Conditions
Operating Conditions
Operating Temperature:
Humidity:
Altitude:
0°C to +55°C
Up to 90% non-condensing
5000m
Storage and Transport Conditions
Storage Temperature:
Humidity:
Altitude:
-20°C to +75°C
Up to 90% non-condensing
15000m
PXI & CompactPCI Compliance
The module is compliant with the PXI Specication 2.2. Local Bus,
Trigger Bus and Star Trigger are not implemented.
Uses a 33MHz 32-bit backplane interface.
Safety & CE Compliance
All modules are fully CE compliant and meet applicable EU
directives: Low-voltage safety EN61010-1:2010, EMC Immunity
EN61326-1:2013, Emissions EN55011:2009+A1:2010.
Mechanical Characteristics
Single slot 3U PXI (CompactPCI card).
3D models for all versions in a variety of popular le formats are
available on request.
Connectors
PXI bus via 32-bit P1/J1 backplane connector.
Signals via front panel 78-pin male D-type connector, for pin outs
please refer to the operating manual.
Relay Type
The 40-658 is tted with ruthenium reed relays, these offer very
long life with good low level switching performance and excellent
contact resistance stability.
All reed relays are manufactured by our sister company Pickering
Electronics: pickeringrelay.com
Switching Specification - Sense MUX
Switch Type: Ruthenium Reed Relay
Max Switch Voltage: 200VDC*
Max Switch Current:
Max Carry Current:
Max Switching Power:
1A
1.2A
20W
Initial On Path Resistance:
Off Path Resistance:
<150mΩ
>109Ω
Operating Time: 1ms typical,
500µs for multichannel mode
Expected Life, low power load:
Expected Life, full power load:
>108 operations
5x106 operations
* For full voltage rating, signal sources to be switched must be fully
isolated from mains supply and safety earth.