DeZurik APCO DAT User manual

DeZURIK
Instruction and Operating Manual Page 2 © 2022 DeZURIK, Inc.
Instructions
These instructions are for use by personnel who are responsible for the installation, operation and
maintenance of DeZURIK valves, actuators or accessories.
Safety Messages
All safety messages in the instructions are identified by a general warning sign and the signal word CAUTION,
WARNING or DANGER. These messages indicate procedures to avoid injury or death.
Safety label(s) on the product indicate hazards that can cause injury or death. If a safety label becomes difficult
to see or read, or if a label has been removed, please contact DeZURIK for replacement label(s).
Personnel involved in the installation or maintenance of valves should be constantly alert to potential
emission of pipeline material and take appropriate safety precautions. Always wear suitable protection
when dealing with hazardous pipeline materials. Handle valves which have been removed from service
with suitable protection for any potential pipeline material in the valve.
Inspection
Your DeZURIK product has been packaged to provide protection during shipment; however, items can be
damaged in transport. Carefully inspect the unit for damage upon arrival and file a claim with the carrier if
damage is apparent.
Parts
Replaceable wear parts are listed on the assembly drawing. These parts can be stocked to minimize
downtime. Order parts from your local DeZURIK sales representative or directly from DeZURIK. When ordering
parts please provide the following information:
If the valve has a data plate: please include the 7-digit part number with either 4-digit revision number
(example: 9999999R000) or 8-digit serial number (example: S1900001) whichever is applicable. The
data plate will be attached to the valve assembly. Also, include the part name, the assembly drawing
number, the balloon number and the quantity stated on the assembly drawing.
If there isn't any data plate visible on the valve: please include valve model number, part name, and
item number from the assembly drawing. You may contact your local DeZURIK Representative to help
you identify your valve.
DeZURIK Service
DeZURIK service personnel are available to maintain and repair all DeZURIK products. DeZURIK also offers
customized training programs and consultation services. For more information, contact your local DeZURIK
sales representative or visit our website at DeZURIK.com.

DeZURIK
June 2014 Page 3 D12029
Table of Contents
Description - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3
Adjustment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
4

DeZURIK
June 2014 Page 4 D12029
Description
The DAT Double Acting Throttling Device is used to throttle exhausting air and allow large amount of air
to enter the system in a vacuum condition.
The DAT is used to regulate (adjust) the air exhaust on pump start-up to attain a smooth pressure
transition between the exhausting air and the operating pressure. During pump shut-off, the device will
automatically allow a large amount of air in during vacuum to protect against pipe collapse.
NOTE: The DAT is not a stand-alone device and cannot be installed directly to the pipeline. The
DAT must be installed in the outlet port (top) of the Air/Vacuum Valve or Combination Air
Valve.

DeZURIK
June 2014 Page 5 D12029
Adjustment
See Figure 1 for part identification.
The setting on the Double Acting Throttling Device must be tolerable to the collapsing
pressure on the system.
Confirm that the DAT is firmly screwed to the valve outlet (top).
To adjust the DAT, close the Teflon plug (5) by turning the adjustable stem (3) clockwise to be fully
extended. Note that the device is designed so as it cannot completely close. Open the Teflon plug by
turning the adjustment stem counter clockwise, three (3) full turns.
Start pump. Listen and observe the Air/Vacuum Valve closing when water column reaches the valve. If
the valve gently closes and no surge is apparent, lock the position setting in by turning the lock nut (6)
against the cover (2).
If there is a "thunk" when valve is closing, turn the adjustable stem (3) one full turn clockwise to farther
close the devise and restrict the amount of air evacuating. Depending on the application, more than one
turn towards the closed position may be necessary. This will establish a back pressure on the rising
column of liquid to reduce shock, pressure surge and water hammer to the system.
NO
DESCRIPTION
1
Housing
2
Cover
3
Adjustable Stem
4
Spring
5
Plug
6
Lock Nut
7
Nipple
Figure 1: DAT Double Acting Throttling Device

Limited Warranty
DeZURIK, Inc. (“Seller”) manufactured products, auxiliaries and parts for a period of twenty-four (24) months from date of shipment from
Seller’s factory, are warranted to the original purchaser only against defective workmanship and material, but only if properly stored, installed,
operated, and serviced in accordance with Seller’s recommendations and instructions.
For items proven to be defective within the warranty period, your exclusive remedy under this limited warranty is repair or replacement of
the defective item, at Seller’s option, FCA Incoterms 2020 Seller’s facility with removal, transportation, and installation at your cost.
Products or parts manufactured by others but furnished by Seller are not covered by this limited warranty. Seller will provide repair or
replacement for other’s products or parts only to the extent provided in and honored by the original manufacturer’s warranty to Seller, in
each case subject to the limitations contained in the original manufacturer’s warranty.
No claim for transportation, labor, or special or consequential damages or any other loss, cost or damage is being provided in this limited
warranty. You shall be solely responsible for determining suitability for use and in no event shall Seller be liable in this respect.
This limited warranty does not warrant that any Seller product or part is resistant to corrosion, erosion, abrasion or other sources of failure,
nor does Seller warrant a minimum length of service.
Your failure to give written notice to us of any alleged defect under this warranty within twenty (20) days of its discovery, or attempts by
someone other than Seller or its authorized representatives to remedy the alleged defects therein, or failure to return product or parts for
repair or replacement as herein provided, or failure to store, install, or operate said products and parts according to the recommendations
and instructions furnished by Seller shall be a waiver by you of all rights under this limited warranty.
This limited warranty is voided by any misuse, modification, abuse or alteration of Seller’s product, accident, fire, flood or other Act of God,
or your failure to pay entire contract price when due.
The foregoing limited warranty shall be null and void if, after shipment from our factory, the item is modified in any way or a component of
another manufacturer, such as but not limited to, an actuator is attached to the item by anyone other than a Seller factory authorized service
personnel.
All orders accepted shall be deemed accepted subject to this limited warranty, which shall be exclusive of any other or previous Warranty,
and this shall be the only effective guarantee or warranty binding on Seller, despite anything to the contrary contained in the purchase order
or represented by any agent or employee of Seller in writing or otherwise, notwithstanding, including but not limited to implied warranties.
THE FOREGOING REPAIR AND REPLACEMENT LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS AND
LIABILITIES, INCLUDING ALL WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR OF MERCHANTABILITY OR
OTHERWISE, EXPRESSED OR IMPLIED IN FACT OR BY LAW, AND STATE SELLER’S ENTIRE AND EXCLUSIVE LIABILITY AND YOUR
EXCLUSIVE REMEDY FOR ANY CLAIM IN CONNECTION WITH THE SALE AND FURNISHING OF SERVICES, GOODS OR PARTS,
THEIR DESIGN, SUITABILITY FOR USE, INSTALLATION OR OPERATIONS.
Disclaimer
Metric fasteners should not be used with ASME Class 150/300 bolt holes and flange bolt patterns. If you use metric fasteners with ASME
Class 150/300 bolt holes and flange bolt patterns, it may lead to product failure, injury, and loss of life. DeZURIK Inc. disclaims all liability
associated with the use of metric fasteners with ASME Class 150/300 bolt holes and flange patterns, including but not limited to personal
injury, loss of life, loss of product, production time, equipment, property damage, lost profits, consequential damages of any kind and
environment damage and/or cleanup. Use of metric fasteners with ASME Class 150/300 bolt holes and flange bolt patterns is a misuse that
voids all warranties and contractual assurances. If you use metric fasteners with ASME Class 150/300 bolt holes and flange bolt patterns,
you do so at your sole risk and any liability associated with such use shall not be the responsibility of DeZURIK, Inc. In addition to the
foregoing, DeZURIK’s Manufacturer’s Conditions apply.
Limitation of Liability
IN NO EVENT SHALL SELLER BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES
WHATSOEVER, AND SELLER’S LIABILITY, UNDER NO CIRCUMSTANCES, WILL EXCEED THE CONTRACT PRICE FOR THE GOODS
AND/OR SERVICES FOR WHICH LIABILITY IS CLAIMED. ANY ACTION FOR BREACH OF CONTRACT BY YOU, OTHER THAN RIGHTS
RESPECTING OUR LIMITED WARRANTY DESCRIBED ABOVE, MUST BE COMMENCED WITHIN 12 MONTHS AFTER THE DATE OF
SALE. Sales and Service
For information about our worldwide locations, approvals, certifications and local representative:
250 Riverside Ave. N., Sartell, MN 56377 ● Phone: 320-259-2000 ● Fax: 320-259-2227
DeZURIK, Inc. reserves the right to incorporate our latest design and material changes without notice or obligation.
Design features, materials of construction and dimensional data, as described in this manual, are provided for your information only
and should not be relied upon unless confirmed in writing by DeZURIK, Inc. Certified drawings are available upon request.
Printed in U.S.A.
October 2021
Table of contents
Other DeZurik Controllers manuals

DeZurik
DeZurik G-SERIES User manual

DeZurik
DeZurik G-SERIES User manual

DeZurik
DeZurik G-SERIES User manual

DeZurik
DeZurik LA Series User manual

DeZurik
DeZurik POWERRAC R3 User manual

DeZurik
DeZurik POWERRAC R1 User manual

DeZurik
DeZurik G-SERIES User manual

DeZurik
DeZurik T Series User manual

DeZurik
DeZurik G-SERIES User manual

DeZurik
DeZurik AFR2 User manual

DeZurik
DeZurik G-SERIES User manual

DeZurik
DeZurik G-SERIES User manual

DeZurik
DeZurik 145 User manual

DeZurik
DeZurik M Series User manual

DeZurik
DeZurik MO User manual

DeZurik
DeZurik AFR3 User manual

DeZurik
DeZurik G-SERIES User manual

DeZurik
DeZurik G-SERIES User manual

DeZurik
DeZurik KSL User manual

DeZurik
DeZurik POWERRAC R1 User manual