manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Controllers
  8. •
  9. Honeywell Ex-Or MLS Installation and operation manual

Honeywell Ex-Or MLS Installation and operation manual

This manual suits for next models

3

Other Honeywell Controllers manuals

Honeywell N20 Series User manual

Honeywell

Honeywell N20 Series User manual

Honeywell LP1501 Operator's manual

Honeywell

Honeywell LP1501 Operator's manual

Honeywell CIPer 50 Installation and operation manual

Honeywell

Honeywell CIPer 50 Installation and operation manual

Honeywell L4188 User manual

Honeywell

Honeywell L4188 User manual

Honeywell UDC 2300 User manual

Honeywell

Honeywell UDC 2300 User manual

Honeywell ScanDome HTX-5000 User manual

Honeywell

Honeywell ScanDome HTX-5000 User manual

Honeywell Spyder 5 User manual

Honeywell

Honeywell Spyder 5 User manual

Honeywell SP10K User manual

Honeywell

Honeywell SP10K User manual

Honeywell M7410E Operation manual

Honeywell

Honeywell M7410E Operation manual

Honeywell VC2 Series, VC4 Series, VC60 Series,... User manual

Honeywell

Honeywell VC2 Series, VC4 Series, VC60 Series,... User manual

Honeywell T775U2006 User manual

Honeywell

Honeywell T775U2006 User manual

Honeywell WEB-300E Series User manual

Honeywell

Honeywell WEB-300E Series User manual

Honeywell T775 Series User guide

Honeywell

Honeywell T775 Series User guide

Honeywell R7284B User manual

Honeywell

Honeywell R7284B User manual

Honeywell FR124 User manual

Honeywell

Honeywell FR124 User manual

Honeywell ML7999C Operation manual

Honeywell

Honeywell ML7999C Operation manual

Honeywell V4600 User guide

Honeywell

Honeywell V4600 User guide

Honeywell M847D User manual

Honeywell

Honeywell M847D User manual

Honeywell KromSchroder IC 40 Manual

Honeywell

Honeywell KromSchroder IC 40 Manual

Honeywell HVC0001 User manual

Honeywell

Honeywell HVC0001 User manual

Honeywell V9055A User manual

Honeywell

Honeywell V9055A User manual

Honeywell SEC-H-602 User manual

Honeywell

Honeywell SEC-H-602 User manual

Honeywell SSW2-1M User manual

Honeywell

Honeywell SSW2-1M User manual

Honeywell T775A/B/M 2000 Series User manual

Honeywell

Honeywell T775A/B/M 2000 Series User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

MLS Digital Luminaire Controllers
MLSM2000D/DALI - Digital Control Module
DHW/DHS - Mini Detector Head
Installation and Commissioning
Instructions
Note: QuickSet Pro required for commissioning
Electrical Connections
Mounting Details
The MLSM2000 Control Module is designed to be mounted within a luminaire on fixing centres of 135mm.
2
Connections to the control module as shown above should be made using solid strand wire (0.5-1.5mm ).
The interconnect cable between the detector head and the control module should be routed away from other
luminaire internal wiring and away from the lamp end-caps.
The recommended position for the detector is in the middle of the luminaire. Where this is not possible and the
detector is fitted near one end of the lamps, please ensure that the detector is at the ‘cold’ end of the lamps.
The DHW/S Mini Detector Head should be mounted such that only the raised front section of the bezel protrudes
through the cut out in the louvre or infill panel, constructed in accordance with the dimensions above.
Installation Guidelines
1. The Mini Detector Head must be mounted within the luminaire. Do not mount remotely.
2. The connecting cable must not be extended.
3. Artificial light illuminating the Mini Detector Head must only be reflected from the room, i.e. there must be no
direct illumination.
4. In order to achieve satisfactory light-level regulating operation, a detector must observe a substantially
greater proportion of artificial light from the luminaire(s) under its control than from neighbouring luminaires
not under its control. This is particularly important when planning the installed layout of linear luminaires that
have an integral detector positioned at one end.
800mm
Flying Lead RJ12
Plug
MSM2000D
DHW/DHS
Connection
}
Polarity-free
Digital Output
Neutral
Live
Digital Control Module
Operating voltage 230V 50Hz 10%
Control output: Digital
Max 4 x DSI Ballast
Power consumption: <2W
tc 70 C
Read instructions prior to installation
Made in the EC
+
-
0.5 - 1.5
Neutral
OneSwitch Input
N/C
Live IN
Detector
Connection
}
MLS Bus
Polarity Free
TM
0.5 - 1.5
Polarity-free
Digital Output
Operating voltage 230V 50Hz 10%
Control output: Digital
Max 4 x DSI or DALI Ballast
Power consumption: <2W
tc 70 C
+
-
Ex-Or
Haydock Lane, Haydock
Merseyside, WA11 9UJ
Tel. 01942 719229
Fax. 01942 272767
Control Module Part No
Please read instructions
prior to installation
Made in the EC
MLSM2000D
MSM2000D
MLSM2000DALI
MSM2000DALI
Neutral
OneSwitch Input
N/C
Live IN
}
Polarity-free
Digital Output
TM
Neutral
Live IN
}
Digital Regulating Ballast(s)
OneSwitch Input
for manual control
Mains Supply
D1
D2
MLS Bus
Polarity-free To next MLS device
(Please refer to
Application Note
AN4001 for MLS
cable specification)
DSI/DALI Ballast
Polarity-free Digital Input
E
N
L
14.9mm
21.5mm
TOP VIEW
SIDE VIEW
135mm
32mm
21.5mm
147.5mm
18.8mm 17.5mm 21.3mm
(Height = 21mm)
Digital Control
Module
Mini Detector
Head
30mm
Commissioning
Detectors are supplied factory pre-set which ensures the lighting will switch on automatically as soon as power is
applied. Final commissioning of the detectors requires the use of the QuickSet Pro Programmer.
Commissioning Detectors using the QuickSet Pro Programmer
It is important that the Programmer be held perpendicular and a distance of between 0.5m and 2m from the sensor.
1. Switch on by pressing any button (and unlock with top left rectangular button).
2. Point the programmer at detector and press the DOWNLOAD button. The programmer will confirm the
product’s identity and call up the correct menu of parameters and their current settings.
3. Use a combination of UP, DOWN, FORWARD and BACK buttons to navigate the parameter menu, selecting
options for each shown.
4. When options for all parameters have been selected, point the programmer at the detector and press the
UPLOAD button. The luminaire(s) will switch off briefly during the programming process.
5. After a short period of inactivity (default 5 minutes), the programmer hibernates retaining the most recent
settings.
OneSwitch Dimming
OneSwitch dimming affords local control to the end-user whereby a simple, momentary, push-to-make wallswitch
can be used to raise or lower the lighting level or to toggle the output ON/OFF. A press of less than 1 second will
toggle the output status while a longer press will raise or lower the output. Each time the switch is pressed, the
direction of dimming reverses. If the switch has not been pressed for 5 seconds, the direction will be up (brighter) -
unless the output is already above 90% in which case the direction is down. A wiring diagram is shown left.
To Test with HC5A Hand-held Controller
Once the MLS Luminaire Controllers have been installed within the luminaires, the HC5A may be used to dim and
brighten luminaires and to switch them ON and OFF. One of 6 different lighting scenes can also be recalled.
Important Additional Notes
1. A means for disconnection must be incorporated in the fixed wiring in accordance with the current wiring regulations.
2. Although nominally 12V, the dimming output is not SELV and therefore should be treated with the same respect as
mains with regard to wiring practice. The 0V line of the dimming output is almost at Neutral potential.
3. The dimming control output should be connected only to the control input of the ballasts - never to other detectors.
4. This equipment should be used to control only those ballasts powered from the same phase as the detector.
5. Do not connect mains to the MLS bus.
2
6. It is imperative that the MLS bus is wired with the correct type of cable; normally it should be 1.5mm unscreened
twisted pair. Please read Application Note AN4001 for more details.
7. Due to the fact that the photocell is on the ceiling looking down, it is not possible for measurements made with a lux
meter on the working plane to remain constant when daylight illuminates the ceiling and the working plane to a
differing extent. Therefore, products of this type should be regarded as capable of maintaining an APPROXIMATE
light level only.
8. This equipment switches lights no more frequently than would a responsible human occupant. However,
manufacturers of some particular lighting types (e.g. ‘2D’ luminaires) may specify a maximum number of switching
cycles in order to achieve a predicted lamp life. Please check with the manufacturer of the luminaires to ensure that
they are compatible with automatic controls in this respect.
9. Some devices in this product range feature a silvered surface finish; this is intended for decorative purposes only.
Care should be taken to avoid accidental separation of the silvered coating from the product. If the unit is built into a
luminaire that is subsequently wrapped in film having adhesive properties, it is recommended that a layer of suitable
packaging material be used to protect the silvered area.
Honeywell Ex-Or
Albery House, Springfield Road,
Horsham, West Sussex RH12 2PQ
Tel: +44 (0)1942 719229
Fax: +44 (0)1942 508753
Email: technicalsales.ex-or@honeywell.com
www.ex-or.com
At the end of their useful life
the packaging and product
should be disposed of via a
suitable recycling centre.
Do not dispose of with normal
household waste.
Do not burn.
6.0m
2.5m
Technical Data
2
MLS CABLE: 1.5mm unscreened twisted-pair : see Application Note AN4001
MAXIMUM RECOMMENDED MOUNTING HEIGHT: 3.0m
RANGE: Cone-shaped detection pattern, diameter (at floor level) = 2.4 x mounting height
OPERATING VOLTAGE: 230V 50Hz (UK & Europe)
o
ta = 0 - 50 C
CAPACITY: Max 4 x DSI or DALI ballasts
o
INTERCONNECT CABLE TEMPERATURE RATING: 60 C
COLOUR: White RAL9010 or silver bezel (DHW = White, DHS = Silver)
MATERIAL: UV stabilised polycarbonate (DHW/DHS)
Flame retardant PC/ABS (MLSM2000D/DALI)
IP RATING: 20
OVERALL DIMENSIONS: 32 (l) x 21.5 (w) x 21.3 (h) mm (DHW/DHS)
147.5 (l) x 30 (w) x 21 (h) mm (MLSM2000D/DALI)
WEIGHT: 32g (DHW/DHS)
48g (MLSM2000D/DALI)
W4265F