manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DH Instruments
  6. •
  7. Control Unit
  8. •
  9. DH Instruments CONSTANT VOLUME VALVE User manual

DH Instruments CONSTANT VOLUME VALVE User manual

Document 560076 050216
DH Instruments, Inc.
4765 East Beautiful Lane
Phoenix AZ 85044-5318
USA
Tel 602.431.9100
Fax 602.431.9559
[email protected]
www.dhinstruments.com
Constant Volume Valve
P/N 402151
Installation Instructions
CONSTANT VOLUME VALVE, P/N 402151,
INCLUDES:
QTY PART NO DESCRIPTION
1 402177 Valve, constant volume
2 103686 DH500 F x DH200-2 M adaptor
1 102159 10-32 UNF M x 1/8 in. barb adaptor
1 103426 10-32 UNF M x 1/8 in. quick connector
1 560076 Instruction Sheet
INTRODUCTION
The constant volume valve is a pneumatically
actuated needle valve with a return line connecting the
inlet to a coaxial compensator. Needle displacement is
matched by an equal and opposite volume
displacement on the compensator.
SPECIFICATIONS
Port A connection: DH200-2*
Port B connection: DH200-2*
Drive air connection (to open valve): 10-32 UNF F
Operating fluid: Oil
Maximum line pressure: 200 MPa (30 000 psi)
Maximum differential pressure on Port A or Port B:
200 MPa (30 000 psi)
Drive air pressure required to open valve:
- With zero differential: <500 kPa (70 psi)
- With 200 MPa differential, Port A:<400 kPa (60 psi)
- With 200 MPa differential, Port B: 750 kPa (110 psi)
Maximum drive air pressure: 850 kPa (125 psi)
Typical change in volume on port A or B when the
valve is opened or closed: <0.2 mm3
* DH200-2 is equivalent to HIP HF2 for 1/8 in. OD, coned and
threaded stainless steel tube
INSTALLATION
Connect the valve between the two pressure
systems to be isolated using ports A and B. Use
the DH200-2 M x DH500 F adaptors supplied if
desired. To install the adaptors, remove the
DH200-2 glands and collars from the DH200-2
connections.
Connect a drive air supply to the drive air connection.
Use the 10-32 UNF M x barb adaptor or 10-32 UNF
M x quick connector supplied if desired.
Figure 1. Constant volume valve cutaway view
APPLICATION NOTES
• To open the valve, supply drive air pressure to the
drive air port. To close the valve, vent the drive air
pressure.
• To reduce the opening/closing speed of the valve,
put an adjustable restriction or fixed orifice on the
drive air supply and exhaust. This can be useful
to reduce pressure perturbations from the valve
opening/closing.
• To automate opening and closing of the valve, use
a three way, low pressure solenoid valve to control
drive air/vent supply to the valve actuator.
• To reduce the relative effect of the small change in
volume due to deformation of the valve seat after the
valve closes, add volume to the pressurized system.
• After the valve closes, a small volume change
occurs from elastic deformation of the seat. The
deformation can be reduced by special shimming
to reduce the force of the needle on the seat when
the valve is closed, but the maximum differential
pressure on port A is reduced.

This manual suits for next models

1

Other DH Instruments Control Unit manuals

DH Instruments PG7600 User manual

DH Instruments

DH Instruments PG7600 User manual

DH Instruments MPC1 VARIABLE VOLUME REPAIR KIT User manual

DH Instruments

DH Instruments MPC1 VARIABLE VOLUME REPAIR KIT User manual

DH Instruments PK-7600-VAC-VENT User manual

DH Instruments

DH Instruments PK-7600-VAC-VENT User manual

DH Instruments PPCH User manual

DH Instruments

DH Instruments PPCH User manual

DH Instruments MFC-CB User manual

DH Instruments

DH Instruments MFC-CB User manual

Popular Control Unit manuals by other brands

United Technologies Interlogix  ATS7310 Installation sheet

United Technologies

United Technologies Interlogix ATS7310 Installation sheet

MG R3-CT4B instruction manual

MG

MG R3-CT4B instruction manual

Johnson Controls VP140 L Series installation instructions

Johnson Controls

Johnson Controls VP140 L Series installation instructions

Konica Minolta IP-411 user guide

Konica Minolta

Konica Minolta IP-411 user guide

iRex IRM72S1-400 installation manual

iRex

iRex IRM72S1-400 installation manual

Ebyte E31-433T30D user manual

Ebyte

Ebyte E31-433T30D user manual

CLA-VAL 90-01 Installation operation & maintenance

CLA-VAL

CLA-VAL 90-01 Installation operation & maintenance

HKC APL-5 Series Installation, operation & maintenance manual

HKC

HKC APL-5 Series Installation, operation & maintenance manual

Moxa Technologies CA Series user manual

Moxa Technologies

Moxa Technologies CA Series user manual

Drayton TRV4 operating instructions

Drayton

Drayton TRV4 operating instructions

ARAG 853 Series Installation, use and maintenance

ARAG

ARAG 853 Series Installation, use and maintenance

DSC PowerSeries PC585 installation manual

DSC

DSC PowerSeries PC585 installation manual

Cepex PVC-U Series manual

Cepex

Cepex PVC-U Series manual

Aim APE429-32 Hardware manual

Aim

Aim APE429-32 Hardware manual

Norgren VP60 Series Operation manual

Norgren

Norgren VP60 Series Operation manual

GE Baker Hughes 2900-40 Series Maintenance manual

GE

GE Baker Hughes 2900-40 Series Maintenance manual

Hewlett Packard Enterprise Synergy 660 Gen10 user guide

Hewlett Packard Enterprise

Hewlett Packard Enterprise Synergy 660 Gen10 user guide

EWM T4.06-Tetrix AC/DC Smart 2.0 operating instructions

EWM

EWM T4.06-Tetrix AC/DC Smart 2.0 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.