7 8
Operation
How to work as a Humidier
Make sure the CEF is securely in place and the
CEF lid is turned so that the AquaSolvo logo is
aligned with the control panel
Close the top cover
Pour 2500ml/84.54oz. fresh
tap water into the water tank
Press ON/OFF button to
start working and toggle
the HOCI air disinfection
button off to start
humidier function
12
3 4
Maintenance
Only use genuine D&HLifelabs CleVaFilter&AquaSoFilter with your AquaSolvo
Eco Air Sterilizer with Humidier. Use of any other lters may compromise the
proper operation of your lter and potentially void your warranty.
Pre-Filter: Part Number AS05FT-1
Clean every month, or more frequently depending on your usage
Cold evaporation lter (CEF) : Part Number AS05FT-2
Replace every 6 months
To purchase replacement lters, please visit: www.DHLifelabs.com
Cleaning
• We recommend that you clean the machine at least weekly. Clean the water
tank with fresh tap water to get rid of odors. Use a clean dry cloth to wipe
the external surfaces of the machine.
• It is highly recommended to soak the cold evaporation lter (CEF) in cool
clean tap water for 1 hour each month to minimize odors.
• If the water stays in the tank for 7 days, pour out the residual water in the
tank and prepare a fresh salt water mixture to continue operation.
• Remove and clean the pre-lter every month. Use cool clean tap water and
a dry cloth to clean the pre-lter.
• Do not use wax, furniture polish, or any chemical solution to clean the
sterilizer.