DIEL me 100 V2 Quick guide

ME 100 V2
4-20 mA
MANUALE DI INSTALLAZIONE ED USO
INSTALLATION AND INSTRUCTIONS MANUAL
MANUAL DE INSTALACION Y USO


ITALIANO
-
3
-
CARATTERISTICHE TECNICHE
Dimensioni
• Contenitore 90x90x130 mm incluse morsettiere.
• Pannello frontale 96x96 mm.
• Peso 0.6 Kg.
Alimentazione
• Alimentazione universale (24÷240) Volt AC/DC ± 10% 50/60 Hz senza rispetto
della polarità, assorbimento massimo 4 VA.
Ingressi
• Otto ingressi analogici, rilevamento e controllo temperatura con sensori PT100
a tre fili nel range da -10 a +200 °C.
Uscite
• Cinque relè 250V AC 10 A massimi (carico resistivo), 1 contatto pulito.
• Uscita analogica 4-20mA riferita al canale più caldo galvanicamente isolata.
Caratteristiche
• Contenitore in NORYL auto estinguente.
• Grado di protezione pannello frontale in policarbonato: IP65 (IP66 a richiesta)
• Grado di protezione pannello posteriore lato morsettiere: IP20
• Display a segmenti luminosi.
• Visualizzazione automatica della temperatura più elevata e del relativo numero
di canale.
• Segnalazioni di pre-allarme, allarme, guasto sonde, ventilazione, funzionamento
manuale, massimi storici.
• Accesso alla programmazione della centralina direttamente da pannello frontale.
• Possibilità di selezionare indipendentemente ogni singolo canale.
• Soglia di allarme e preallarme impostabile nel range (-9°C ÷ 199°C).
• Precisione: ±1% riferito al fondo scala ±1 digit.
• Gestione del ventilatore di raffreddamento su tutti i canali.
• Controllo del ventilatore mediante isteresi con due valori di temperatura (H e L).

ITALIANO
-
4
-
• Quattro modalità di funzionamento selezionabili.
• Riconoscimento sonde in avaria, massima flessibilità di gestione e semplicità di
programmazione, controllo della validità dei dati introdotti in fase di
programmazione.
• Memorizzazione permanente dei valori programmati e dei dati raggiunti da
ciascun canale (soglie e massimi storici).
• Rigidità dielettrica tra i contatti dei relè e linea di alimentazione 2.5 KV AC per
60".
• Possibilità di utilizzare le sonde per termostatare l'ambiente.
• Risoluzione 1°C.
• Temperatura di lavoro (-20°C ÷ 60°C).
• Umidità massima ammessa: 90% senza condensa.
• Collegamento mediante morsettiere estraibili polarizzate.
• Possibilità di commutare manualmente i relè mediante il menù di test relè per
simulare o controllare l’affidabilità del contatto.
• Manuale tecnico in tre lingue (altre lingue a richiesta).
• Costruzione in accordo alle normative .
• Filtro d' ingresso contro i disturbi a normativa .
• Tropicalizzazione (opzionale).
MONTAGGIO
Eseguire nel pannello un foro da 91X91 mm, fissare la centralina con i ganci in
dotazione.
ALIMENTAZIONE
La centralina può essere alimentata con (24÷240) Volt AC/DC ±10% 50-60 Hz
senza rispetto di polarità.
I morsetti di alimentazione sono indicati con la sigla AL1-AL2 e sono inoltre riportati
in tabella TAB 1 alla fine del manuale.

ITALIANO
-
5
-
COLLEGAMENTI ELETTRICI
Eseguire i collegamenti sulle morsettiere estraibili seguendo lo schema riportato in
tabella TAB 1 alla fine del manuale.
Il relè di FAULT risulta normalmente eccitato durante il funzionamento della
centralina (FAULT STATUS A, TAB 1), in caso di guasto alle sonde o di mancanza
di alimentazione il relè si diseccita (FAULT STATUS B, TAB 1).
I relè FNA e FNB sono preposti alla gestione dei ventilatori di raffreddamento delle
macchine elettriche oppure per il condizionamento del locale dove sono situate le
macchine stesse.
I relè ALARM e PRE AL vengono eccitati al superamento di un grado delle rispettive
soglie impostate.
Ogni sonda PT100 standard è dotata di tre fili, uno bianco e due rossi.
Collegare il filo bianco nei morsetti contrassegnati dal simbolo del sensore nella
serigrafia, morsetti (3,6,9,12,15,18,21,24).
I ventiquattro morsetti di ingresso relativi alle otto sonde sono così predisposti:
Sonda N. 1 morsetti 1-2-3, Sonda N. 2 morsetti 4-5-6.
Sonda N. 3 morsetti 7-8-9, Sonda N. 4 morsetti 10,11,12.
Sonda N. 5 morsetti 13-14-15, Sonda N. 6 morsetti 16-17-18.
Sonda N. 7 morsetti 19-20-21, Sonda N. 8 morsetti 22,23,24.
Porta analogica 4-20 mA:
• Positivo: morsetto 25
• Negativo: morsetto 26
• Impedenza massima ammessa 500 Ohm
Range di temperature:
• Scala 4-20mA (-10°C 4mA - 200°C 20mA)
• Formula di trasformazione: Iout = (T+10)/210*16 + 4 (corr. in mA, temperature
in °C)
Tutti i cavi di trasporto dei segnali di misura dovrebbero preferibilmente essere:
• separati da quelli di potenza,
• schermati, meglio se anche cordati,
• di sezione non inferiore a 0.5 mm².

ITALIANO
-
6
-
DESCRIZIONE SEGNALAZIONI
Le lettere che compaiono sul display a singola cifra assumono il seguente
significato:
F: modo di funzionamento, assume valori da zero fino a tre.
P: soglia di preallarme oltre la quale si eccita il relativo relè
A: soglia di allarme oltre la quale si eccita il relativo relè
L: soglia inferiore sotto la quale si diseccita il relè di ventilazione.
H: soglia superiore oltre la quale si eccita il relè di ventilazione.
t: tempo minimo di attivazione ventilazione espresso in minuti che intercorre tra una
accensione ed il successivo eventuale spegnimento.
Le scritte che compaiono sul display a tre cifre assumono il seguente significato:
ICF: sonda PT100 in avaria (interruzione oppure assenza di sonda)
SCF: sonda PT100 in avaria (corto circuito)
rES: azzeramento memoria guasto sonde avvenuto
FnA, Fnb: ventilazione relativa ad uno specifico canale e ventilatore
CH(n): stato di uno specifico canale n (1-8)
PrE: relè di preallarme
ALL: relè di allarme
FnA: primo relè ventilazione.
Fnb: secondo relè ventilazione.
FLt: relè di guasto
PROGRAMMAZIONE DELLA CENTRALINA
Premendo a lungo e contemporaneamente i tasti UP/DOWN si entra in modalità
programmazione.
I tasti, in questa fase assumono le seguenti funzioni:
Tasto UP incrementa il valore proposto, tasto DOWN decrementa il valore
proposto, tasto ENTER conferma il valore e passa al parametro successivo.
La programmazione inizia dalla scelta del modo di funzionamento F.
F=0: gruppo di otto canali attivi, una sola soglia di allarme e preallarme valida per
tutti i canali, funzione di ventilazione disattivata. Con F=0 si impostano solo i due
parametri P ed A.

ITALIANO
-
7
-
F=1: gruppo di otto canali attivi, una sola soglia di allarme e preallarme valida per
tutti i canali, funzione di ventilazione attiva con una sola soglia di accensione e
spegnimento ventilazione valida per tutti i canali.
Con F=1 si impostano solo i quattro parametri P, A, L, H.
F=2: gruppo di otto canali attivi, una sola soglia di allarme e preallarme valida per
tutti i canali, funzione di ventilazione attiva, una sola soglia di accensione e
spegnimento ventilazione valida per tutti i canali, controllo ventilazione anche a
tempo (parametro t).
Con F=2 oltre ai parametri impostati con F=1 si imposta il parametro t in minuti cioè
il tempo in minuti che deve restare comunque attiva la ventilazione prima di
intervenire sullo spegnimento. Questo garantisce un tempo minimo di attivazione
ventilazione indipendentemente dal valore impostato dalla soglia L.
F=3: programmazione indipendente per ogni canale di tutte le soglie di allarme,
preallarme, accensione e spegnimento ventilatore; Con F=3 vengono chiesti in
successione i seguenti parametri: Tempo t in minuti, cioè il tempo che deve restare
comunque attiva la ventilazione prima di intervenire sullo spegnimento. Questo
garantisce un tempo minimo di attivazione ventilazione indipendentemente dal
valore impostato dalla soglia L.
Per ogni canale appare poi la scritta CH(n) con n (1-8), tramite i tasti UP/DOWN è
necessario decidere se rendere il canale attivo oppure no, in caso affermativo,
viene chiesto di introdurre le soglie P e A.
Appare di seguito la scritta FnA, tramite i tasti UP/DOWN è necessario decidere se
si desidera controllare la ventilazione su quel canale oppure no, se affermativo,
viene inoltre chiesto di introdurre le soglie L e H di ventilazione, in caso il canale
non sia attivo o nel caso non si desideri la ventilazione, viene proposta la scelta per
il secondo ventilatore Fnb con la stessa procedura utilizzata per FnA si procede
alla configurazione del secondo ventilatore, in caso di esclusione verrà proposta la
configurazione del canale successivo. Confermare infine i successivi parametri non
rilevanti in questa versione per terminare la programmazione.
Configurazione di default:
F=0, P=140, A=160, L=90, H=100, t=0.
Per motivi di sicurezza viene in ogni caso controllato il tempo necessario per la
programmazione. Oltre un minuto dall’inizio della fase di programmazione, la
stessa viene interrotta e non salvata

ITALIANO
-
8
-
(restano attivi pertanto i parametri precedentemente presenti in memoria). Alla fine
della programmazione, vengono salvati i nuovi dati in memoria, viene effettuato un
test dei display, la centralina si porta quindi in modalità di visualizzazione
automatica.
VISUALIZZAZIONE DATI
Contestualmente alla modalità di funzionamento F si possono visualizzare tutti i
parametri di interesse mediante i tasti UP/DOWN. Per visualizzare costantemente
un dato oppure la lettura di un canale, posizionarsi sullo stesso e premere il tasto
AUTO/MANUAL, il led MANUAL si accenderà segnalando lo stato di
funzionamento manuale. Per ritornare a visualizzare il canale più caldo in
automatico premere nuovamente il tasto AUTO/MANUAL. Per accedere alla
visualizzazione dei massimi valori storici registrati premere contemporaneamente
ed a lungo i tasti AUTO/MANUAL e ENTER/TEST, il led T MAX - PROGRAM
segnalerà l’ingresso nel relativo menù. Sempre utilizzando i tasti UP/DOWN si
potranno vedere i massimi relativi ai canali attivi. Per ritornare alla visualizzazione
normale premere AUTO/MANUAL. La memorizzazione dei massimi viene
cancellata ogni volta che si effettua una nuova programmazione della centralina.
TEST DEI RELE’
Premendo il tasto ENTER/TEST viene effettuato il test del display, tenendolo
premuto a lungo si entra nel menù di test relè. Utilizzando i tasti UP/DOWN si
possono far commutare i relè. Per passare ai successivi relè premere
ENTER/TEST, per uscire dal menù premere AUTO/MANUAL.
DIAGNOSTICA SONDE TERMOMETRICHE
Gli stati di anomalia delle sonde sono segnalati nel seguente modo:
• commutazione del relè FLt (guasto)
• accensione del led di FAULT,
• lampeggio del led relativo al canale guasto e memorizzazione permanente dello
stesso.

ITALIANO
-
9
-
In tali casi è possibile conoscere la natura dei guasti nel seguente modo:
• se la sonda PT100 risulta essere interrotta, viene visualizzata la scritta
lampeggiante ICF con relativo numero di canale
• se la sonda PT100 risulta essere in corto circuito, viene visualizzata la scritta
lampeggiante SCF con relativo numero di canale.
Quando una sonda attiva viene rilevata guasta il dispositivo memorizza il fenomeno
mantenendo lampeggiante il relativo led anche se questa ultima ripristina il normale
funzionamento; per cancellare la memoria di guasto premere a lungo il tasto
AUTO/MANUAL fino al comparire della scritta rES sul display.
Lo stato dei relè di ventilazione è segnalato nel seguente modo:
• Led FAN spento: nessuna ventilazione.
• Led FAN acceso fisso: almeno un ventilatore acceso.
• Led FAN acceso lampeggiante: entrambi i ventilatori accesi.
MODALITA' DEGLI INTERVENTI
Quando una delle sonde termometriche supera di 1 grado centigrado il valore
prefissato dai limiti, dopo circa 1 secondo avviene la commutazione del relè e del
diodo led corrispondente.
Appena i valori di temperatura scendono di un grado centigrado sotto i valori
impostati i relè ed i led ricommutano.
NORME DI GARANZIA
La centralina è coperta da garanzia per un periodo di 3 anni dalla data di collaudo
posta sia sull’etichetta che sul manuale allegato. La garanzia è ritenuta valida
quando è stato accertato che le cause del guasto sono imputabili a difetti di
fabbricazione o ad errata taratura delle sonde.
Non si risponde invece per guasti dovuti ad errato cablaggio delle sonde o errata
tensione di alimentazione (es. 400 Volt AC).
Non si risponde in ogni caso per danni provocati dal mal funzionamento della
centralina stessa.
Le riparazioni in garanzia, salvo diverso accordo tra le parti sono effettuate presso
la nostra sede di Montecchio Maggiore (VI).

ITALIANO
-
10
-
ATTENZIONE
Non effettuare prove di rigidità dielettrica o di scariche parziali sulle macchine
elettriche con la centralina inserita, evitare se possibile di collegare direttamente la
centralina al secondario del trasformatore da proteggere, può accadere che, senza
protezione, alla chiusura dell'interruttore a valle del trasformatore, si presentino
sovratensioni che possono danneggiare l'apparecchiatura. Questo è tanto più
evidente se la tensione di alimentazione della centralina, è di 230 V AC e se
esistono condensatori di rifasamento.

ENGLISH
-
11
-
TECHNICAL FEATURES
Dimensions
• Box 90x90X130 mm included terminal blocks.
• Front panel 96X96 mm.
• Weight 0,6 Kg.
Power Supply
• Power supply (24÷240) Volt AC/DC ± 10% 50/60 Hz without polarity respect,
maximum absorption 4 VA.
Inputs
• Eight analogical inputs, temperature control and mapping with PT100 sensor at
three wires inside range from -10 °C to +200 °C.
Outputs
• Five relays 250V AC, 10 A max (resistive load), one free switch contact.
• Galvanically insulated analogical output 4-20mA referred to the channel with the
highest temperature.
Characteristics
• Self-extinguishable NORYL Box.
• Protection degree front panel in polycarbonate: IP65 (IP66 on request)
• Protection degree of rear panel on terminal board side: IP20
• Display with light segments.
• Visualisation of max temperature and the relevant channel in the automatic
mode.
• Alerts of pre-alarm, alarm, probes fault, fanning, manual function, historic highs.
• System programming directly by frontal panel.
• Possibility to select independently each channel.
• Limit of alarm and pre-alarm settable in the range (-9°C ÷ 199°C).
• Precision ± 1% on full scale ± 1 digit.
• Management of the cooling fan on all channels.
• Comparison of temperature for cooling fan between two different levels (L and

ENGLISH
-
12
-
H).
• Four selectable operating modes.
• Detection of fault probes, maximum flexibility of managing and semplicity of
programming, checking of validity of the insert data during programming phase.
• Continuos storage of planned and reached values by each channel (limits and
historic highs).
• Dielectric isolation: 2.5 KV AC for 60”.
• Software configuration to control the environment temperature.
• Resolution 1° C.
• Working temperature of device from -20°C to 60°C.
• Max allowed dampness in the room 90% not condensing.
• Electrical connections with fast polarised connectors.
• Possibility of manual relays switch through menu test relays to simulate and
check the reliability of contact.
• Technical manual in three languages (and more on request).
• Construction in accordance with rules .
• Input filter for power supply in accordance with rules .
• Tropicalization (optional).
ASSEMBLY
Perform a square hole measuring 91x91 mm, fasten the ME100 V2 through the
special hooks.
POWER SUPPLY
The device can be supplied with (24÷240) Volt AC/DC ± 10% 50/60 Hz without
respect of polarity.
The power supply terminals are indicated with the abbreviation AL1-AL2 and are
also shown in table TAB 1 at the end of the manual.
ELECTRICAL CONNECTIONS
Perform the connections on the terminal board following the scheme on TAB1 at

ENGLISH
-
13
-
the end of this manual.
FAULT relay usually results excited during normal working of device (FAULT
STATUS A, TAB 1), in case of failure of probes or feeding absence, the relay
switches off (FAULT STATUS B, TAB 1).
FNA and FNB relays are used for drive fan cooling systems of electric machines or
for the conditioning of the environment where the machines are situated.
FAN relay is dedicated to the management of the fans of cooling of the transformer
or for the conditioning of the environment where the transformer is installed.
The ALARM and PRE AL relays switch on when the temperature is higher than one
degree of set level.
Each probe type PT100 is gifted with three wires, one of them is white and the other
two are red.
Connect the white wire to the terminal board marked whit sensor logo on plugs (3-
6-9-12-15-18-21-24).
The twenty-four connectors relevant to the eight probes are divided as follows:
Probe N. 1 connectors 1-2-3, Probe N. 2 connectors 4-5-6.
Probe N. 3 connectors 7-8-9, Probe N. 4 connectors 10-11-12.
Probe N. 5 connectors 13-14-15, Probe N. 6 connectors 16-17-18.
Probe N. 7 connectors 19-20-21, Probe N. 8 connectors 22-23-24.
Analogic port 4-20 mA:
• Positive TX+: connector 25.
• Negative TX-: connector 26.
• Maximum permissible impedance 500 Ohm.
Temperature range:
• Scale 4-20 mA (-10°C 4 mA - 200°C 20 mA)
• Transformation formula: Iout = (T+10)/210*16 + 4 (current in mA, temperature in
°C)
All measured signals cables must preferably be:
• Separated from the power cables
• shielded, better if also stranded
• With a section of not less than 0.5 mm
2

ENGLISH
-
14
-
MESSAGES DESCRIPTION
The letters that appear on single digit display assume the following meaning:
F: function mode (range 0-3)
P: pre alarm level, the PrE relay switch on when the temperature exceeds the level
set
A: alarm level, the ALL relay switch on when the temperature exceeds the level set
L: low level for cooling system switch off, the FAN relay switches off when the
temperature gets lower than all L values
H: High level for cooling system switch on, the FAN relay switch on when the
temperature gets higher than any H value
t: min. time that must elapse before the device turn off the fan cooling system (see
programming details for more information)
The words that appear on three-digit display assume the following meaning:
ICF: PT100 probe failure due to interruption or absence of probe.
SCF: PT100 probe failure due to electrical short circuit.
rES: memory resetting of the failure probe effected.
FnA, FnB: cooling system status referring to a specific channel or fan.
CH(n): State of a specific channel n (1-8).
PrE: pre alarm relay.
ALL: alarm relay.
FnA: first fan relay.
FnB: second fan relay.
FLt: FAULT relay.
PROGRAMMING
Push and hold together the buttons UP/DOWN for programming menu.
The functions of the buttons in this phase are indicated as follow: button UP
increases the proposed value, button DOWN decreases the proposed value, button
ENTER/TEST confirms and switches to the next step.
The programming procedure begins with the choice of F parameter.
F=0: group of eight active channels, only one level for alarm and pre alarm valid for
all channels, fan cooling system function deactivated. With F=0 is possible to set

ENGLISH
-
15
-
only P and A parameters.
F=1: group of eight active channels, only one level for alarm and pre alarm valid for
all channels, active fan cooling system with only one level valid for lighting H and
swithing off L.
With F=1 is possible to set only four parameters: P, A, L, H.
F=2: group of eight active channels, only one level for alarm and pre alarm valid for
all channels, active fan cooling system with only one level valid for lighting H and
switching off L, control of fan cooling system also with time parameter t.
With F=2, in addition to the parameters set with F=1, is possible to set a parameter
t in minutes, t is the minimum time that must elapse before the device turn off the
fan cooling system. This guarantees a minimum time of activation for fan cooling
system independently from the value of L.
F=3: Independent programming for each channel of all levels P, A, L, H; in this
mode it is also possible to accede to RS485 section. With F=3 the device asks in
sequence the following parameters: Time t in minute, t is the minimum time that
must elaps before the device turn off the fan cooling system. This guarantees a
minimum time of activation for fan cooling system independently from the value of
L. For each channel appears the word CH(n) with n (1-8), by means of the buttons
UP/DOWN you choose if a channel is active or not, in affirmative case, it is asked
to put the P and A parameters.
Afterwards the word FnA appears, with the buttons UP/DOWN you choose if fan
cooling system is active or not for that channel, in affirmative case, it is asked to
put the L and H parameters, in case the channel is not active or fan cooling system
is deactivated for that channel the device asks the choice for the next channel,
using the same procedure for FnA, on set the second fan, in case of exclusion will
be proposed the set-up of next channel, after that, confirm all proposed parameter
(not relevant in this configuration) to finish the program procedure.
Default configurations: F=0, P=140, A=160, L=90, H=100, t=0.
Anyway, the necessary time for programming is checked.
Over 1 minute from beginning of the programming phase, the same is interrupted
and not saved. (the previous set limits remain active). At the end of programming
the new data will be saved in memory, the device executes a display test and the
system is prearranged in automatic way and visualises the maximum measured
temperature and the relative channel.

ENGLISH
-
16
-
DATA VISUALIZATION
Referring to F it is possible to show all parameters of interest by buttons UP/DOWN.
To show one specific parameter, or one specific measure of temperature, select it
and push the button AUTO/MANUAL, the MANUAL led turns on to flag a manual
status mode. To return to the normal automatic mode push again AUTO/MANUAL
button.
During automatic working the higher temperature and the relative channel number
appear on the display. To visualize the maximum values of the machine push and
hold the buttons AUTO/MANUAL and ENTER/TEST at the same time. The
visualisation of the maximum temperatures is signalised through the T MAX -
PROGRAM led which is placed on the front-end panel.
With the buttons UP/DOWN it is possible to see the historical maximum
temperature achieved by all active channels. For exit push button AUTO/MANUAL.
Please note that the maximum values are reset every time you confirm a new
program sequence.
TEST RELAYS
Pushing ENTER/TEST, the device performs a display test, pushing and holding the
same buttons, the device enters in test relays mode.
With the buttons UP/DOWN it is possible to switch a relays state. To test the other
relays, push ENTER/TEST button, to exit push AUTO/MANUAL button.
THERMOMETRICAL PROBES DIAGNOSTIC
Errors on probes are indicated as follows:
• FLt relay (FAULT relay) switch off,
• FAULT led turns on,
• led of the relative channel blinks and the fault state is stored.
In these cases, it is possible to know the type of failure:
• If PT100 probe is interrupted, the blinking word ICF appears on display together
with the number of the channel
• If PT100 probe is in short circuit state, the blinking word SCF appears on display

ENGLISH
-
17
-
together with the number of the channel. When the device detects one channel
in failure state, it stores the situation and holds blinking the relative led.
To clean the failure state in memory, keep pushed the AUTO/MANUAL button until
a rES word appears on display.
The-cooling status is shoed as following:
• Led FAN off: all cooling systems are off.
• Led FAN on: one cooling system is active.
• Led FAN blink: all cooling systems are active.
MODALITY OF THE INTERVENTIONS
When one of the thermometric probes detects a temperature over 1 degree
centigrade to the prefixed value, after approx. 1 the relevant relay and led switch.
As soon as the surveyed temperature descents under 1 degree centigrade the relay
and the led changes again.
WARRANTY RULES
The device has a warranty period time of 3 years from test date marked on the label
and at the end of this manual.
The warranty is valid only whether damages are due to manufacturing defects or to
an incorrect calibration of the probes.
We aren't liable for damages due to a wrong wiring of probes or to a wrong power
supply voltage (for example 400 Volt AC).
At any rate we aren't liable for damages due to the bad working of the equipment.
The reparations in guarantee, except different accord among the parts, will be
carried out in our factory in Montecchio Maggiore (VI).
ATTENTION
Do not carry out dielectrical test or partial discharge on the electric machine with
the device inserted, if possible avoid connecting the device directly to the
secondary of the transformer to protect, otherwise the transient overvoltage can
damage the device.

ENGLISH
-
18
-
This is always clearer if the power supply voltage of the device is 230 VAC and in
case of condensers for the remaking.

ESPAÑOL
-
19
-
CARACTERÍSTICAS TÉCNICAS
Dimensiones
• Contenedor 90x90X130 mm, terminales incluidos.
• Frontal 96X96 mm.
• Peso: 0,6 Kg.
Alimentación
• Alimentación universal (24÷240) Volt AC/DC ±10% 50/60 Hz, sin respetar la
polaridad, absorción máximo 4 VA.
Entradas
• Ocho entradas análogicas, detección de temperatura con sensores PT100 à tres
cables en el intervalo de -10 ºC a +200 ºC.
• RS422-485 Half/Full duplex protocolo ASCII de propiedad.
Salida
• Cinco relé 250 VAC 10 A (carga resistive), 1 contacto de intercambio.
• Salida analogica 4-20 mA referida al canal mas caliente galvánicamiente aislada.
Caracterìsticas
• Contenedor en NORYL auto extinguible.
• Panel frontal de grado de protección en policarbonato: IP65 (IP66 bajo pedido)
• Grado de protección del panel posterior en el lado del tablero de terminales: IP20
• Pantalla de segmento luminoso.
• Visualización automática de la temperatura máxima y del canal relativo.
• Señales de prealarma, alarma, mal funcionamento de las sondas, ventilación,
funcione manual, máximos históricos.
• Programación centralita directamente en el panel frontal.
• Posibilidad de seleccionar de manera independiente cada canal.
• Umbral de alarma y prealarma configurable en el intervalo (-9 ° C ÷ 199 ° C).
• Precisión ± 1% escala completa ± 1 digit.
• Gestión del ventilador de enfriamiento en todos los canales.
• Control del ventilador por histéresis con 2 valores de temperatura (H y L).

ESPAÑOL
-
20
-
• Cuatro modos de operación seleccionables.
• Reconocimiento de mal funcionamento de las sondas, máxima flexibilidad de
gestión y simplicidad de programación, control de la validez de los datos
introducidos en la fase de programación.
• Almacenamiento permanente de los valores programados y los datos
alcanzados por cada canal (valores históricos y máximos).
• Resistencia dieléctrica entre los contactos del relé y la línea de alimentación de
2,5 KV AC para 60 ".
• Prueba de rigidez dieléctrica 2.5 KV AC para 60”.
• Posibilidad de uso de las sondas para termostar el ambiente.
• Resolucion 1° C.
• Temperatura de trabajo de la centralita de -20 ºC a 60 ºC.
• Máxima humedad ambiental admitida 90% sin condensación.
• Conexiones eléctricas en bornas extraibles polarizadas.
• Posibilidad de cambiar manualmente los relés usando el menú de prueba de
relés para simular o verificar la confiabilidad del contacto.
• Manual técnico en tres idiomas (otros idiomas a petición).
• Construcción de acuerdo a las normas .
• Filtro de ingreso contra disturbios de acuerdo a las normas .
• Tropicalización (opcional).
MONTAJE
Realizar en el panel un orificio de 91X91 mm, fijar la centralita con los ganchos
suministrados.
ALIMENTACIÓN
La centralita puede ser alimentada por (24÷240) voltios AC/DC ±10%, 50-60 Hz
sin tener en cuenta la polaridad.
Los terminales de alimentación se indican con la abreviatura AL1-AL2 y también
se reportan en le tabla TAB 1 al final del manual.
Table of contents
Languages:
Other DIEL Controllers manuals