User Manual for QM-7300 Fuel Cell Digital Alcohol Analyzer
Page 2 FiT239-LC-09Y03555 (2009-08-03)
Alert Signals
QM-7300 is designed to alert user as following:
I) Low Level – “LO” will be shown on display if the concentration detected is less than 0.005%BAC.
II) Safety Level – For measurements between 0.005%BAC and Alert Level, the alcohol concentration level shows on
the display with backlight turn on.
IV) Alert Level – The analyzer beeps 30 times together with “HI” flashes alternatively. Red backlight flashes alternatively.
The LCD will keep the RED backlight.
DON’T DRIVE: You exceed the alert level
V) Exceed Level – For measurements higher than the alert concentration level, the analyzer beeps together with RED
backlight flashes for 20 seconds. The digital alcohol concentration reading displays on the screen. If
reading greater than 0.4%BAC, “HI” flashes together with RED backlight. Press any key can stop the
alert sound.
YOU ARE PROHIBITED TO DRIVE since you already exceed the alert level.
Note:
1) fter any 5 consecutive tests, allow the device to rest for 2 minutes.
A
2
) When the product is unused, please store in a dry environment.
3
) When battery energy not enough to do the alcohol testing, Please replace the batteries immediately.
) If the difference between two successive reading >0.01%BAC, user should test again.4
5
) During the breath sampling, user should NOT block the gas outlet. Otherwise, the reading will be affected.
6) Recalibration:According to the international standard (e.g. DIN31051), all measurement instrument should be
recalibrated every 6 months.
Battery Charge:
Step1. Please connect the USB cable to the socket of FiT239-LC, press the ◀key for 3 seconds to turn on the machine and
activate battery charging.
Step2. When charging, the will flashes.
It will take 4-5 hours to charge full. After charge full, the not flashes.
Product Specifications:
1. Display Range:
Low,0.005 ~ 0.4% BAC, Hi
2. Memory: 25 memories
3. Power Input: 3.7V Li-batteries
4. Display: Digital display with Bi-color backlighting
5. Power save: Auto OFF, 2 minutes after any key in
6. Breath sampling: About 5 seconds continuous breath sample
7. Cycle time: ~30 seconds
8. Dimensions: 125.7*63.2*27.8 mm
9. Weight: 85g (without batteries)
10. Alert level calibrated: 0.05%BAC
11. Agency Approval: CE
12. Accessories: 2 pcs blowing tubes
13. Operating temperature: -0℃ to +40℃
The QM-7300 Digital Alcohol Computer should be used as a general guide to the level of alcohol in your body.
Many factors (e.g. environment gas residue, smoke & various smell in human mouth, etc…)
may affect the BAC level, so the Readings are For Reference Only.
Neither the reseller nor manufacturer accept any liability arising from the use of this unit
D
DO
O
N
NO
OT
T
d
dr
ri
in
nk
k
b
be
ef
fo
or
re
e
y
yo
ou
u
d
dr
ri
iv
ve
e!
!
Specifications are subject to change without notice
Made in China