Digikeijs DR 4088 series User manual

DR4088CS / GND / OPTO 2021-08-11
P 1
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
DR 4088xx
Instrucon manual
(2021-08-11)
© Copyright 2005 – 2018 digikeijs, the Netherlands. All
rights reserved. No informaon, images or any part of
this document may be copied without the prior wrien
permission of Digikeijs.

DR4088CS / GND / OPTO 2021-08-11
P 2
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
1 Index
1.0 General informaon 2
1.1 Index 2
1.2 Warranty and warranty condions 3
1.3 Legal informaon 3
2.0 Product overview 4
2.1 General product informaon 4
2.2 Technical Specicaons 4
2.3 Hardware Overview 5
3.0 Programming 6
3.1 DR4088xx programming (start address in the
DR500xx assigned 6
3.2 DR4088xx reset 7
4.0 Connecon examples 7
4.1 Feedback modules DR4088CS; 2-wire track 8
4.2 Feedback modules DR4088CS and DR5033
Booster; 2-wire track 9
4.2 Feedback modules DR4088OPTO; Hall sensors,
3-wire track 10
4.3 Feedback modules DR4088OPTO; Hall sensors,
2-wire track 11
4.4 Feedback modules DR4088GND
3-wire track 12
1 General Informaon

DR4088CS / GND / OPTO 2021-08-11
P 3
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
1.2 Warranty and warranty condions
All our products come with a 24-month manufacturer's warranty. Please read these operang instrucons carefully.
Damage to the product caused by non-compliance with these instrucons will invalidate the warranty.
ATTENTION: The warranty is void if the housing of the product is opened.
1.3 Legal informaon
Prinng errors and mistakes, technical or other changes as well as changes in the availability of individual products are expressly reserved.
Data and illustraons are non-binding. All changes to hardware, rmware and soware are reserved.
We reserve the right to change the design of the product, the soware and / or the rmware without prior noce.
Copyright
All Digikeijs operang instrucons and other wrien instrucons supplied and/or downloadable are protected by copyright.
Reproducon is not permied without the wrien permission of Digikeijs.

DR4088CS / GND / OPTO 2021-08-11
P 4
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
2.0 Product overview
2.1 General product informaon
The DR4088xx is a feedback module that can be connected to the central unit via the S88(N)®.
The DR4088-xx has 16 feedback inputs.
The DR4088xx is available as CS version (current sensor 2-wire track), as OPTO version (connecon of reed contacts, 3-wire track signal to track ground) and as
GND version (3-wire track).
2.2 Technical specicaons
The connecon terminals of the 16 feedback units are designed for a cross-secon of 0.5mm², the two terminals for "C" are designed for a cross-secon of
0.75mm².
Number of
inputs
Suitable
for
Minimum load for safe
reporng
Max. load per
contact Load
per contact
Max. load per con-
tact Load capacity
per contact for
max. 100 ms
Peak load for 8 feedbacks at
"C" total.
DR4088CS 2 x 8 2 conductors 2 mA 2 A 5 A 6 A an „C“
DR4088OPTO 2 x 8 3 conductors
when using the
DR50xx
- - -
DR4088GND 2 x 8 3 conductors
Important! DR4088GND 3-wire operaon:
Due to the H-bridge (track output) in the DR50xx, feedback devices in the DR4088GND version must not be used against track ground, as
is usually the case with 3-wire tracks. This inevitably leads to the destrucon of the DR50xx.
If a 3-wire driver sll wants to drive with the DR50xx and report back against track ground, the DR4088OPTO
can be used.

DR4088CS / GND / OPTO 2021-08-11
P 5
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
2.3 Hardware Overview
1Connecon feedback 1 to 8
2Common connecon "C" for the right or le detector group.
3Connecon feedback 9 bis16
4S88® OUT connecon
(connue to the next DR4088xx)
5S88® OUT connecon
(to central or previous DR4088xx)
6red LED
(ashing during load or acvity at S88N connecon)
7S88N® IN connector (standard RJ45 patch cable).
(connue to next DR4088xx)
8S88® IN connecon
(connue to the next DR4088xx)
123
45678

DR4088CS / GND / OPTO 2021-08-11
P 6
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
3.0 Programming
First, something fundamental about the S88(N) Bus®:
• The S88(N)® bus is a universal bus system.
• The S88(N)® bus supports a maximum of 256 feedback addresses.
• The addresses are always assigned automacally and connuously. No universal and unique addressing is possible because the S88(N)® bus is not desig-
ned for individual address assignment!
• The S88(N)® can only be set up as a bus (line) network. This always means from 1. feedback to 2. feedback, etc.
3.1 Programming DR4088xx (Assign start address in DR50xx)
The S88(N)® bus system does not provide programming in the actual sense. It only has to be dened in the central with which address the S88(N)® bus starts
and how many modules are located on the bus.
Programming the start address in the DR50xx
1. Start the DR50xx tool.
2. Call up the sengs for the S88(N)® bus with the buon in the ext88N tool.
3. The start address and the number of modules must now be entered in this input mask.

DR4088CS / GND / OPTO 2021-08-11
P 7
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
4.0 Connecon examples
In this chapter you will nd some connecon examples for the DR4088xx. Please note that we are not able to show all possibilies.
3.2 Reset DR4088xx
Important! The DR4088xx The DR4088xx has no funcon for reseng to factory sengs!
Since no sengs or funcons are stored in the feedback module, this is not necessary!
Important! DR4088GND 3-wire operaon:
Due to the H-bridge (track output) in the DR50xx, feedback devices in the DR4088GND version must not be used against track ground, as is usu-
ally the case with 3-wire tracks. This inevitably leads to the destrucon of the DR50xx.
If a 3-wire driver sll wants to drive with the DR50xx and report back against track ground, the DR4088OPTO
can be used.

DR4088CS / GND / OPTO 2021-08-11
P 8
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
4.1 Feedback modules DR4088CS; 2-wire track
® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
DR5000 in conjuncon with S88N® feedback modules
The ext88N connector of the DR5000 is a compable S88N® bus.
In this example the feedback modules DR4088CS (current sensors) are used. These feed-
back modules are connected to the DR5000 and to each other with normal RJ45 cables. A
maximum of 16 S88N® modules with 16 inputs each can be connected to the central unit. A
total of 256 feedback modules (S88N®/ext88N ) can be managed by the DR5000.

DR4088CS / GND / OPTO 2021-08-11
P 9
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
4.2 Feedback modules DR4088CS and DR5033 Booster; 2-wire track
Both sides
track isolaon

DR4088CS / GND / OPTO 2021-08-11
P 10
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
power supply
4.3 Feedback modules DR4088OPTO; Hall sensors, 3-wire track
Light barrier, Hall sensors or
the like
(posive switching PNP)
5V-20V
DC/AC
Feedback "Track mass" switch track reed contact
DR4088OPTO
More DR4088xx
feedback unit

DR4088CS / GND / OPTO 2021-08-11
P 11
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
4.4 Feedback modules DR4088OPTO; switch track, 2-wire track
More DR4088xx
feedback unit
switch track Light barrier, Hall sensors or
the like
(posive switching PNP)
power supply
5V-20V
DC/AC
reed contact push Boon Switch
DR4088OPTO

DR4088CS / GND / OPTO 2021-08-11
P 12
www.digikeijs.com ® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
4.5 Feedback modules DR4088GND;switches, buons, reed contacts
push buon switches reed contacts
Feedback "Track mass" switch track reed contact
Track Out
Central
S88(N)®
Zentrale
Important! DR4088GND 3-wire operaon:
Due to the H-bridge (track output) in the DR50xx, feedback devices in the DR4088GND version must not be used against track ground, as
is usually the case with 3-wire tracks. This inevitably leads to the destrucon of the DR50xx.
If a 3-wire driver sll wants to drive with the DR50xx and report back against track ground, the DR4088OPTO
can be used.
DR4088GND
More DR4088xx
feedback unit
Other manuals for DR 4088 series
1
This manual suits for next models
3
Table of contents
Other Digikeijs Control Unit manuals