manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Dinam Led
  6. •
  7. Temperature Controllers
  8. •
  9. Dinam Led Dn-T2M User manual

Dinam Led Dn-T2M User manual

Dn-T2M
2.4G LED Color Temperature Controller
12
T2M is the 2.4GHz RF wireless synchronization/zone color temperature controller which adopts Dinam multiple
global initiate technology. The control system consists of two parts, the RF remote control and receiver, realize the
signal synchronization on multiple receivers, zone controlled arbitrarily (no more than 8 zones) within effective
distance, a very good solution for the LED project needs sync/zone control wirelessly.
1. Technical Specs:
4. Components Description for Receiver and Remote Control:
Can RF remote the functions of color temperature touch adjustment, brightness adjustment, and DIY scene
modes. User-friendly color wheel for color temperature adjustment, unique LED state light for sync change
indicated, user can simply know the LED working state from distance by checking the remote.
Input Voltage: DC5V Built-in Lithium Battery
Working Current: ≤30mA
Working Frequency: 2.4GHz
RF Remote Distance: 30m
Remote Option: Sync or Zone Control
T2M Remote Control
Standby Time: ≤6 Months
Battery Capacity: 1000mAh
Dimensions: L145×W55×H22(mm)
Package Size: L168×W102×H28(mm)
Weight (G.W.): 200g
T3-CV T3-CC
T2M
Input voltage: DC12V-DC48V
Output voltage: DC3V-DC46V
Output current: CC 350/700/1050mA ×3CH
Output power: 1.05W~48.3W ×3CH Max 144.9W
Compatible remote control: T1/T2/T2M/T3/T3M/T3X
Working temperature: -30℃~55℃
Dimension: L175×W44×H30(mm)
Package size: L178×W48×H33mm
Weight (G.W.): 110g
T3-CC Receiving controller (current 3 in 1)
Input voltage: DC5V-DC24V
Max current load: 6A×3CH Max 18A
Max output power: 90W/216W/432W(5V/12V/24V)
Compatible remote control: T1/T2/T2M/T3/T3M/T3X
Working temperature: -30℃~55℃
Dimension: L175×W44×H30(mm)
Package size: L178×W48×H33mm
Weight (G.W.): 110g
T3-CV Receiving controller
2. Product Size:
55mm
145mm
22mm
44mm
30mm
175mm
170mm
27mm
60mm
86mm
65mm
T2M RF remote control
T3-CV/T3-CC Remote holder
3. The learning ID method of remote control:
If installing multiple receivers in one zone, repeat the above steps, choose the same area key when ID learning.
Learning ID:
Cancelling ID:
1. Turn on the receiver and remote control
Short press "ID learning button" on the receiver, the running light keeps on, then long press 1-8 zone-selection
keys on the remote, the running light returns to flash (the buzzer long beep, the indicator light flashes 3 times),
activated successful.
2.
1. Turn on the receiver and remote control.
2. Press “ID learning button” on the receiver more than 8 seconds, the buzzer beep twice, delete all the learned remote.
DC12V~48V
T3-CC
Current selection switch
(Method of operation see below form)
Remote ID
Learning Button
Power Input Socket
LED Lamp Connected Socket
DC5V~24V
T3-CV
CV receiver
CC receiver
Remote ID
Learning Button
Power Input Socket LED Lamp Connected Socket
warranty
5 years
34
6. System Diagram:
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
zone 1
zone 8
zone 7
zone 6
zone 5
zone 4
zone 3
zone 2
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
n
e
1
z
o
e
n
5
o
z
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
zone 2
zone 1
zone 4
zone 3
zone 2
zone 1
zone 4
zone 3
zone 2
zone 1
zone 4
zone 3
zone 2
zone 1
zone 4
zone 3
zone 2
zone 1
zone 4
zone 3
zone 2
zone 1
zone 4
zone 3
Spacing zone-division
Centralized zone-division
The receivers can be divided into 1~8 zones within effective distance(1pc receiver per zone), no wiring needed
between the receivers.
If you don't need color temperature smooth mode by pressing the , , each zone can set up unlimited
receivers and achieve brightness, color temperature adjustment synchronously.
Receiver
Rec eiver
Receiver
Rece ive r
Recei ver
Rec eiv er
Recei ver
Receiv er
Receiver
Recei ver
Rec eiv er
Rec eiv er
Receiver
Receiv er
Rec eiv er
Receiv er
Rec eiver
Rec eiv er
Rece iver
Receiver
Receiver
Rec eiv er
Rec eiver
Rec eiv er
Receiver
Receiver
Receiver
Receiver
Receiver
Rec eiv er
Recei ver
Rec eiver
Rece iver
Receiver
Receive r
Rec eiv er
Receiver
Rece iver
Receiver
Rece iver
Receive r
Rec eiv er
Receiver
Rec eiv er
Receiver
Receiv er
Rec eiv er
Rec eiv er
Receiver
Receiver
Receiver
Receiver
Receiver
Receiver
Receiver
Receiver
Touch Color Circle
Speed+/Speed-
CT+/CT-
BRT+/BRT-
Sync Status Indicator Light
Scene-saved Keys
On/Off
Zone Selection Keys
M1 M2
(Press for 3 seconds, can save the
scene mode in the 8 current
zone control)
(Keep pressing to adjust
brightness continuously)
Zoning Instructions:
●
●
●
●
Select one of the zone: Press keys 1-8 on the remote control.
Select zone control arbitrarily: press" +any number+ ",
eg: take 456 as a zone, should press " 456 ".
All choose(8 zones): press " " twice.
when a zone is under inactive state, press “Zone selection keys”
to light up that zone.
★Press “Zone Selection Keys” in 3 seconds, the buzzer can be on or off.
5. Other Special Functions:
Turn on the remote, long press the on/off key for 5 seconds until the green light flashes 3 times, and then the
green light flashes, the numbers of the green flash will be the frequency point of the remote. you can only edit the
frequency point after 3 seconds.
Method 2: long press “on/off” key over 5 seconds, the green light flashes, the flash times plus 1 means the
frequency point accumulate 1. In short, long press the “on/off” key 5 seconds each time, the frequency
point will accumulate 1, which will again become value 1 when added to 12, and that cycle repeats.
A. Reset Function:
B. Check and Edit the Frequency Point on the Remote:
Long press simultaneously, release the 2 keys after 3 seconds, the remote will auto off,
means reset completed. and then could restart the remote.
Feature: Reset function is available when remote operates abnormally.
Operation:
a.
Multiple remotes sync-control becomes available when they use the same frequency point.
Revising the frequency point to eliminate the external disturbance. 12 revisable frequency points for user.
b.
After reset or revised the frequency points in the remote, receivers only can be used after relearn the ID. Attn:
Feature:
Check the Frequency Point on the Remote:
Edit the Frequency Point on the Remote: In frequency changing state
Method 1: short press any key from 1-8 and key, the frequency point will be 1-9 correspondingly( represent 9),
the green light will flash in the same numbers. Press again any key or touch the color circle to exit the
frequency edit state.
56
7. Wiring Diagram:
10. Warranty Agreement:
9. Attention:
1. The product shall be installed and serviced by a qualified person.
7. If a fault occurs please return the product to your supplier. Do not attempt to fix this product by yourself.
6. Ensure all wire connections and polarities are correct before applying power to avoid any damages to the LED lights.
5. Please ensure that adequate sized cable is used from the controller to the LED lights to carry the current.
Please also ensure that the cable is secured tightly in the connector.
4. Please check if the output voltage of any LED power supplies used comply with the working voltage of the product.
3. Good heat dissipation will prolong the working life of the controller. Please ensure good ventilation.
2. This product is non-waterproof. Please avoid the sun and rain. When installed outdoors please ensure it is
mounted in a water proof enclosure.
1. We provide lifelong technical assistance with this product:
★This manual only applies to this model. Dinam reserves the right to make changes without prior notice.
4. Any amendment or adjustment to this warranty must be approved in writing by Dinam only.
3. Repair or replacement as provided under this warranty is the exclusive remedy to the customer. Dinam shall
not be liable for any incidental or consequential damages for breach of any stipulation in this warranty.
2. Warranty exclusions below:
For faults beyond the 5-year warranty we reserve the right to charge for time and parts.
A 5-year warranty is given from the date of purchase. The warranty is for free repair or replacement and
covers manufacturing faults only.
Any man-made damages caused from improper operation, or connecting to excess voltage and overloading.
The product appears to have excessive physical damage.
Damage due to natural disasters and force majeure.
Warranty label, fragile label and unique barcode label have been damaged.
The product has been replaced by a brand new product.
……
CV
CC
350mA 700mA 1050mA
T3-CV
121
121
121
121
121
121
w
ww
CV receiver
DC5V-24V
T3-CV
121
121
121
121
121
121
w
ww
CV receiver
DC5V-24V
T3-CV
121
121
121
121
121
121
w
ww
CV receiver
DC5V-24V DC12V-48V
T3-CC
CC receiver
DC12V-48V
T3-CC
CC receiver
DC12V-48V
T3-CC
CC receiver
White/Warm White LED Strip
White/Warm White LED Strip
White/Warm White LED Strip
LED
Panel Light
LED
Panel Light
Round LED
Panel Light
8. The Charging Methods for Remote Control:
1. When charging, please connect USB cable to the mobile charger or computer with the USB interface.
5. The remote should be full charged and stored under low cold drying while a long time without being operated.
And please full recharge every 3 months.
4. Red indicator light flickers meaning low battery and need to be charged. Charging in low battery will affect life
of battery.
3. No memory effect in the lithium battery of remote control. Follow the standard charging procedure even for the
first three times, no need over charge.
2. The blue indicator light flickers while charging, and turns green means the charging is completed. The remote
control can be chargeable even at the OFF state, on which the indicator light is black.

This manual suits for next models

2

Popular Temperature Controllers manuals by other brands

WIKA Obsolete CF1M operating instructions

WIKA

WIKA Obsolete CF1M operating instructions

S+S Regeltechnik HYGRASGARD RFTF Series Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik HYGRASGARD RFTF Series Operating Instructions, Mounting & Installation

nilan Combi 302Polar user manual

nilan

nilan Combi 302Polar user manual

Shinko DSW-100-TH Installation instructions manual

Shinko

Shinko DSW-100-TH Installation instructions manual

Stanford Research Systems PTC10 user manual

Stanford Research Systems

Stanford Research Systems PTC10 user manual

Honeywell W7100 manual

Honeywell

Honeywell W7100 manual

Omron EJ1 EtherCAT user manual

Omron

Omron EJ1 EtherCAT user manual

Eltako PL-SAMTEMP quick start guide

Eltako

Eltako PL-SAMTEMP quick start guide

IVT PRINETO manual

IVT

IVT PRINETO manual

Worcester DT20RF instruction manual

Worcester

Worcester DT20RF instruction manual

nvent Raychem RTD4AL installation instructions

nvent

nvent Raychem RTD4AL installation instructions

Myron L ULTRAPEN PTBT2 manual

Myron L

Myron L ULTRAPEN PTBT2 manual

Danfoss 102 Installation & user's instructions

Danfoss

Danfoss 102 Installation & user's instructions

Opt Lasers TEC-8A-24V-PID-HC operating manual

Opt Lasers

Opt Lasers TEC-8A-24V-PID-HC operating manual

Tekmar 479 user manual

Tekmar

Tekmar 479 user manual

Ogden ETR-901 instruction manual

Ogden

Ogden ETR-901 instruction manual

Ropex RESISTRON RES-5027 operating instructions

Ropex

Ropex RESISTRON RES-5027 operating instructions

Hobo S-THB-M002 manual

Hobo

Hobo S-THB-M002 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.