DIODE LED DI-DMX-WIFI-WMUS-3Z-WH User manual

DRY LOCATION
1 OF 5 IG050919-4.0
DMX ZONE CONTROLLER INSTALLATION GUIDE
®
COLOR-CHANGING
INSTALLATION GUIDE
DMX WALL MOUNT ZONE CONTROLLER
24VDC
12VDC
COMPATIBLE
DMX
SAFETY & WARNINGS
QUICK SPECS / MODELS
TOOLS FOR INSTALL
Phillips-head screwdriver
INSTALLATION
DI-DMX-WIFI-WMUS-3Z-WH
Input Voltage 12 - 24VDC Constant Voltage
Output Signal DMX512
WiFi Transming
Distance 40 .
®
1 2
3
Flat-head screwdriver
Mini at-head screwdriver Wire stripper
1
TURN POWER OFF AT CIRCUIT BREAKER
SHOCK HAZARD! May result in serious injury or death.
Turn power OFF at circuit breaker prior to installaon.
2
DETERMINE LOCATION TO INSTALL COMPONENTS
®
1 2 3
V+
V-
V+
CH1 - R
CH2 - G
CH3 - B
CH4 - W
0-5 0-9 0-9
Data IN
Data OUT
LED Driver(s) Controller DMX Decoder Luminaire
See SYSTEM DIAGRAM for more informaon. DMX luminaires can be
connected directly to controller. DMX Decoders are only ulized to
control Non-DMX type luminaires.
3
If system remains unresponsive or is working improperly, turn OFF main
power at breaker and verify all connecons.
4
CONNECT COMPONENTS
Only use copper wiring. Reference WIRING CONNECTIONS and SYSTEM
DIAGRAM further in this guide for visuals.
TURN POWER ON AT CIRCUIT BREAKER
1. Install in accordance with naonal and local electrical code
regulaons.
2. This product is intended to be installed and serviced by a qualied,
licensed electrician.
3. DO NOT connect directly to high voltage power. Install with a
compable Class 2 constant voltage LED driver (power supply).
4. Only install compable 12V and 24VDC constant voltage luminaires.
5. This product is rated for indoor installaon and is not protected
against moisture.
6. Do not modify product beyond instrucons or warranty will be void.

2 OF 5 IG050919-4.0
DMX ZONE CONTROLLER INSTALLATION GUIDE
®
1 2 3
Dynamic Mode
Short press changes mode/pauses
mode. Long press adjusts speed of
dynamic mode. See ‘Dynamic Mode
Chart’ for mode descripons.
Power
Short press to turn ALL zones and
channels ON/OFF.
RGB Brightness
Long press to adjust brightness of
RGB colors simultaneously (7 steps
of brightness). Adjust W (4CH)
channel seperately to adjust tone. Zone Control
Short press to conrtol zones 1, 2, or 3.
Long press to turn individual zone
ON/OFF.
Color Wheel
Adjust RGB color mixing. RGB ‘White’ Presets
Short press for 3 types of ‘White’ RGB presets:
warm white, neutral white, cool white. Useful
for applicaons that don’t ulize W (CH4) for
RGBW applicaons.
Power Indicator
Red indicates unit is OFF.
Blue indicates unit is ON.
Blue flash indicates DATA is transming.
R, G, B, W Channel Adjustment
Short press to turn channel ON/OFF.
Long press to adjust brightness.
MOBILE DEVICE OPERATION
The DMX controller can also be controlled remotely via WiFi with a
compable IOS/Android mobile device. Go to iOS or Google Play App
Store. Search for “EasyColor Pro” and download applicaon.
WIRING CONNECTIONS
INSTALLATION CONT.
DO NOT connect directly to 120VAC.
See ‘System Diagram’ for a general system design.
To DMX Decoder
or DMX Fixture
From 12-24V Driver
Reset
MOUNTING
Pop o faceplate with
a athead screwdriver.
Mount to a standard switchbox.
PAIRING CONTROLLER TO MOBILE DEVICE
1. Go to WiFi sengs of mobile device.
2. Connect to WiFi Network ‘EasyLighng’.
3. Type in Password ‘0123456789’.
4. Open EasyColor Pro Applicaon.

3 OF 5 IG050919-4.0
DMX ZONE CONTROLLER INSTALLATION GUIDE
PINOUT CONNECTION GUIDE
DYNAMIC MODE CHART
SETTING DMX ADDRESS
Each DMX decoder or DMX luminaire needs to be addressed correctly so the controller
can disnguish between each decoder. To pair a DMX decoder or luminaire to a specic
zone of the controller (1-3), set each decoder/luminaire to one of the following addresses:
• Zone 1: Set to address ‘001’ (will be xed to address 001 – 004)
• Zone 2: Set to address ‘005’ (will be xed to address 005 – 008)
• Zone 3: Set to address ‘009’ (will be xed to address 009 – 012)
Each zone of the controller is xed with 4 DMX addresses to control the 4 channels:
CH1 – Red, CH2 – Green, CH3 – Blue, CH4 – White or X.
Example of DMX Addressing Display
Digital Display
The following diagrams/tables indicate the appropriate connecons for patching your own CAT5/RJ45, and XLR-3 splice cables. These diagrams
are for general reference and may slightly dier between dierent cable manufacturers.
1 2 3 4 5 6 7 8
The Dynamic Mode tool plays factory-programmed
scenes. Choose up to 10 dierent scenes. Short
press switches/pauses the mode. Long press
adjusts speed of the dynamic mode.
Mode Descripon
1Fade 1 - B M R O Y G C
2Fade 2 - B G O W C M B
3Fade 3 - R W C G C W B W
4Skip 1 - R Y W C G W B M W Y
5RGB Fade In/Out
6RGB Fade In
7 RGB Fade Out
8 RGB Skip
9 Fade 4 - B M O G C
10 Fade 5 - W Y W M C W G W M C
11 All Channels O
Pin No. Wire Color Funcon
1White/Orange Data +
2 Orange Data -
3White/Green None
4Blue None
5White/Blue None
6Green None
7 White/Brown May be used as 2nd ground
8 Brown Ground
Pin No. Funcon
1Ground
2 Data -
3 Data +
Once DMX address is set on luminaire or DMX decoder, ensure to Press Zone 1, 2, or 3 on the controller to control desired zone.

4 OF 5 IG050919-4.0
DMX ZONE CONTROLLER INSTALLATION GUIDE
SYSTEM DIAGRAM
The following diagram is provided as an example system design. CAT5 (RJ45 connecons) data cables are the most cost-eecve soluon for
transming DMX-512 signals. XLR-3 cables may also be installed but require an addional adapter for connecng to DMX decoders. Always review
each component installaon guide for detailed and up-to-date wiring instrucons. Install in accordance with NEC and local regulaons.
AC Power
50/60Hz
L
N
Class 2 12-24VDC Driver**
Installed in Junction Box‡
G*
N
L
Input
Output
V+
V-
V+
V-
V+
CH1 - R
CH2 - G
CH3 - B
CH4 - W
0-5 0-9 0-9
Data IN
Data OUT
V+
V-
V+
CH1 - R
CH2 - G
CH3 - B
CH4 - W
0-5 0-9 0-9
Data IN
Data OUT
AC Power
50/60Hz
L
N
Class 2 12-24VDC Driver**
Installed in Junction Box‡
G*
N
L
Input
Output
V+
V-
CAT5 / Ethernet Cable (RJ45 Connections)
DMX Decoder
DMX Decoder
V- V+
V- V+
RGBW Tape Light / Fixture‡‡
V+ V+
CH1 R
CH2 G
CH3 B
CH4 W
V+ V+
CH1 R
CH2 G
CH3 B
Install applicable wire gauge / type
CH4 - W connection only utilized for RGBW / RGB(X) installation.
Wall Washer / DMX-512 Fixture‡‡
AC Power
50/60Hz
RJ45 / XLR-3
Adapter Connector
RGB Tape Light / Fixture‡‡
RJ45 Splice Cable
Wiring Connections
Brown Ground
White/Orange Data +
Orange Data -
White/Brown wire may be used as
an additional ground.
G
+
-
DMX Data
Output
RJ45 Coupler
DMX Controller
Installed in Wall Box‡
®
1 2 3
V+
V -
* Driver may not require a fault ground connecon. Refer to driver specicaons for addional informaon.
** Install a compable Class 2 constant voltage driver. It is recommended to load the driver no more than 80% its labeled rang for maximum longevity.
‡ Refer to driver specicaons for a compable juncon box.
‡‡ See luminaire specicaons for maximum series run limits.

5 OF 5
®Toll Free: 877.817.6028 | Fax: 415.592.1596 | www.DiodeLED.com | info@DiodeLED.com
© 2019 Elemental LED Inc. All rights reserved. Specicaons are subject to change without noce.
IG050919-4.0DMX ZONE CONTROLLER INSTALLATION GUIDE
TROUBLESHOOTING
For thorough troubleshoong of LED strip light and luminaires, see LED luminaire installaon guides.
LED luminaires not responding to touch
1. Ensure the blue indicator light is on by pressing ‘Power.’ A red indicator signies the device is o. The blue indicator light will blink rapidly when
pressing/holding any key on the touch pad.
2. Ensure the appropriate zone number was pressed prior to controlling the DMX decoder/luminaire. For example, if you know the luminaire is
addressed to zone 1, press ‘1’ prior to controlling.
3. Ensure the individual zone has not been turned o. Long pressing zones 1-3 will turn the specic zone ON/OFF. Addionally, long pressing R, G,
B, W will increase/decrease individual brightness and short pressing will turn R, G, B, W ON/OFF.
4. Ensure the DMX decoder/luminaire is addressed properly. For example, address ‘001’ will respond to zone 1 of the controller. See ‘Seng the
DMX Address’ for addional addressing informaon.
LED luminaire responding incorrectly
Ensure all wiring connecons are correct. Reversing the Data + and Data - will cause lights to icker and not respond to controller.
1. Check power connecons of all components (drivers, DMX decoders/luminaires, DMX controller).
2. Check DMX Data connecons - See Pinout Connecon Guide and System Diagram for RJ45 hard-wiring connecons.
3. Check DMX decoder connecons – See System Diagram for CH 1-4 connecons.
Visit the online product page at www.DiodeLED.com for addional product specicaons & warranty informaon.
• DMX WALL MOUNT ZONE CONTROLLER SPECIFICATION SHEET
For full specicaons.
• VOLTAGE DROP CHARTS
Use to specify appropriate wire gauge for installaon. Available at the ‘Resources’ page at www.DiodeLED.com.
ADDITIONAL RESOURCES
Table of contents
Other DIODE LED Controllers manuals
Popular Controllers manuals by other brands

National Instruments
National Instruments cRIO-9034 Getting started guide

Texas Instruments
Texas Instruments TUSB5052 user guide

National Instruments
National Instruments NI cDAQTM-9138 user manual

Panasonic
Panasonic CZ-ANC2 installation instructions

Norac
Norac UC4+ installation manual

Siemens
Siemens SINUMERIK 802D sl Operator's manual