Divis 26X User manual

v DiViS 2
www.DiViS DVR.com
1. Indoor Model 3
2. Outdoor Model 4
3. General Features 5
4. Camera Description 6
5. Installation 7
5-1. Camera Setup 7
5-2. Standard Connection 8
5-3. Universal Cable – DiViS DVR 9
5-4. Celling Mount Type 10
5-5. Embedded Mount Type 11
5-6. WallMount Type 12
5-7. Corner Mount Type 13
6. Ouick Operating Keys 14
7. Diagnostic 15
8. OSD Menu Setting 16
8-1. OSD Menu Table 16
8-2. DOME SET 17
8-3. CAMERA SET 23
8-4. PRESET SET 25
8-5. AUTO SCAN SET 26
8-6. TOUR SET 27
8-7. PRIVACY SET 28
8-8. PATTERN SET 29
8-9. ALARM SET 30
8-10. SECTOR SET 31
9. DIP Switch Setting 32
9-1. ID Setting 32
9-2. 485 Termination 34
9-3. Protocol 34
9-4. Baud Rate Setting 34
10. Trouble shooting 35
11. Specification 36
11-1. Indoor Model 36
11-2. Outdoor Model 37
12. Dimensions 38
12-1. Indoor Model 38
12-2. Outdoor Model 39
12-3. Fan / Heater 39
CONTENTS

v DiViS 3
www.DiViS DVR.com
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
1. WARNING & CAUTION (For Indoor Models Only)
If you fail to read this information
and handle the product inproperly,
death or serious injury may occur.
This unit should be installed by a trained
Personnel.
This symbol is intended to alert the user to
the presence of uninsulated "dangerous
voltage" within the product's enclosure that
may be of sufficient magnitude to constitute a
risk of electric shock to persons.
This symbol is intended to alert the user to
the presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
Qty Description
(1) Camera
(1) Ceiling Mount Bracket
(1) Wrench
(2) Screw Ø 0.11in (Ø3mm) x 6 screw
(5) Screw Ø 0.15in (Ø4mm) x 16 screw
(1) Safety Wire
(1) Manual
(1) Ceiling Cover
(5) Cable ties
(2) Terminal Block 2PIN
(1) 3 Pin Terminal Block
(1) 5 Pin Terminal Block
(1) 6 Pin Terminal Block
What's in the Box ?
Turn off immediately if this unit emits
smoke or abnormal heat.
Do not install this unit in an area exposed
to oil or gas.
Do not install this unit on a ceiling that
cannot hold its weight.
Do not touch the power cord with wet
hands.
Clean only with dry cloth.
Do not install this unit in a place of
extremely high or low temperature.
Do not drop, hit, or shake the unit.
Do not expose this product to direct
sunlight or severe ray.
Do not touch the front glass of this unit.
Do not install this unit in areas exposed to
rain or water.

v DiViS 4
www.DiViS DVR.com
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
2. WARNING & CAUTION (For Outdoor Models Only)
If you fail to read this information and
handle the product incorrectly, death or
serious injury may occur.
Input power : With Camera - 24V AC
18wattsat24VAC
Heater : 18 watts
Fan : 2 watts
The heater: activates at +59ºF(10ºC)(±41ºF(±5ºC))
deactivates at +59ºF(15ºC) (±41ºF(±5ºC))
The fan : activates at +113ºF(45ºC)(±41ºF(±5ºC))
deactivates at +95 ºF(35ºC)( ±41ºF(±5ºC))
Do not install the product on a ceiling/wall that cannot
hold its weight.
Do not touch the power cord with wet hands.
Do not install the product in area exposed water, oil, or
gas.
This unit should be installed by a trained
Personnel.
●IP 66
Outdoor Housing acquires
weatherproof capacity Ip66.
●Various Mount Brackets
Available in Wall, Pipe, Gooseneck Mount Brackets
and Corner mount adaptor, Pole mount adaptor
●Built-in Fan / Heater
●Luxury and Classic design
General Features
This symbol is intended to alert the user to
the presence of uninsulated "dangerous
voltage" within the product's enclosure that
may be of sufficient magnitude to constitute a
risk of electric shock to persons.
This symbol is intended to alert the user to
the presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
Qty Description
(1) Outdoor Housing
(1) Camera
(1) Wall Mount Bracket
(2) Screw Ø 0.11in (Ø3mm) x 6 screw
(5) Screw Ø 0.15in (Ø4mm) x 16 screw
(5) Screw (M4x16 screw)
(1) Manual
(10) Cable ties
(1) Wrench
(2) Screws(M3x6)
(2) Screws (M3.5 x 22)
(2) Terminal Block 2PIN
(1) 3 Pin Terminal Block
(1) 5 Pin Terminal Block
(1) 6 Pin Terminal Block
(2) Safety wire (One of them is already attched
to the outdoor housing)
What's in the Box ?

v DiViS 5
www.DiViS DVR.com
3. GENERAL FEATURES
World most silent speed dome camera
Equipped with silent and smooth timing belt and
special gear, low-noisy-technology enhances durable
quality of the camera by reducing the mechanical
vibration. This camera, both indoor and outdoor, is a
perfect match for demanding security and monitoring
burglars.
0.024º dome system accuracy with 1/8 micro step
With 0.024º technical accuracy, this camera provides
an excellent sensitive and delicate controlling on
preset mode by adapting 1/8 micro step and twin gear
system.
Reliable RAM-Material
The mechanical stabilization improves the durability
and long life-time of the camera by using reliable
materials especially, stepping motor, slip ring, timing
belt, and power condenser. The case of this camera
is made of fire resisting material with UL94V-0 grade. It
is useful for indoor environment concerning about fire
accidents.
Compensation function: preset position
The function provides absolute preset position even in
difficult applications where vibration and strong winds
may otherwise affect dome performance.
High quality Slip Ring for longer life-time
This unit has passed 20 million rotations test within 6
months.
Power misconnection protection on 485 terminals
This protection function prevents the communication
terminal from causing problem when power source is
inproperly connected to the RS-485 terminals. Hi-
Speed Dome received a patent for power
misconnection protection on RS-485 terminal
Filter changeable True Day/Night
Top quality images are assured under day and night
conditions with true day / night camera with IR cut filter.
Low light sensitivity is further increased by the digital
slow shutter.
Quick Operation Keys
This camera provides quick function keys to support
most keyboards and DVRs with Pelco protocol
support.
Various Surveillance Functions
Auto Scan repeats pan and tilt between two preset
positions with different speed and dwell time.
165 Preset positions up to 165 programmable preset
positions are available.
8 Group Tour up to 8 programmable Group tours are
available, and each group consists of up to 60 preset
steps with different speed and dwell time.
8 Patterns up to 8 programmable Patterns are
available, each with dwell time of up to 50 seconds,
totalling 400 seconds
8 Sectors up to 8 programmable user-defined sectors
are available.
24 Privacy Masking Zones up to 24 programmable
user-defined privacy masking zones are available.
(26X only)
4 Alarm inputs and 2 Relay outputs up to 4 alarms
inputs and 2 relay outputs are available, and they can
be linked with presets, tours, or patterns.
300º/S 200O/S on Preset speed
The 360º full pan function moves through a maximum
of 350º /sec., enabling you to quickly pinpoint the spot
you want to watch. Tilt speed provides through a
maximum 250º /sec on preset. On preset mode, the
camera is set up to 300º /sec
200º /S Manual speed
This camera provides up to 200º /sec of manual speed
and it is adjustable from 100º /sec to 200º /sec
1/4'' Sony Ex-View CCD
Equipped with Sony Ex-view HAD CCD technology,
these particular cameras provide excellent sensitivity
and low smear levels (26X only)
Multiple languages and protocols
It provides several languages and protocols including
English, Italian, and Polish and Pelco D, Pelco P, and
Maxpro protocol
Intelligent Pan/Tilt Controlling
Pan and tilt speed compensation function linked to
zoom position

v DiViS 6
www.DiViS DVR.com
4. CAMERA DESCRIPTION
FIG. 1
1. Bubble
2. Lock Screw
3. DIP Switch 1
4. DIP Switch 2
5. Camera
6. Lock Holder
7. Power
8. Video Output
9. Loop RX
10. Loop TX
11. Power LED
12. Aux
13. Alarm
14. Mount Holder

v DiViS 7
www.DiViS DVR.com
FIG.4
FIG.3
FIG.2
UNLOCK
5. INSTALLATION
5-1. CAMERA SETUP
1) To separate camera body
Loosen Lock Screw 0.07in (2mm) using wrench. (Don't pull out the screw) (FIG. 2)
Separate the upper body from the lower body by rotating counterclockwise. (FIG. 3, 4)
2) After separating, set DIP switches. (Refer to the page 32, 33, and 34)
3) To assemble camera body
Rotate the upper body clockwise to assemble both bodies (FIG. 5, 6)
Screw up the Lock Screw using wrench. (FIG. 7)
●Don't screw too tight.
LOCK
FIG. 5 FIG. 6 FIG. 7
Screw up to lock the camera body
0.08in (2mm)

v DiViS 8
www.DiViS DVR.com
5. INSTALLATION
5-2. STANDARD CONNECTION
1) Alarm: 4 Alarm input
2) AUX: DC 24V 1A can be used as an AUX terminal.
AUX can be used to turn on the light and control remotely.
3) TX: TX terminal transmits data signal received from RX terminal to other equipment.
TX terminal can be used for daisy chaining.
4) RX: RX terminal receives control signals from a DVR or controller.
5) Video out: BNC connector
6) Power: 18~32V AC, 60~50Hz, 850mA
●Don't connect the power source to the middle terminal of power (Ground).
7)Power On : LED
Sensor (if any)
A
UX 1
SIGNAL
GND
TERMINAL BLOCK
(
FEMALE
)
A
UX 2
MONITOR
TERMINAL BLOCK
(
MALE
)
AC
220/110V
A
C24V ADAPTER
CONTROLLER or DVR
OTHER CAMERA / DEVICE
FIG. 8

v DiViS 9
www.DiViS DVR.com
5. INSTALLATION
5-3. Universal Cable - DiViS DVR
1) Alarm: 4 Alarm input
2) AUX: DC 24V 1A can be used as an AUX terminal.
AUX can be used to turn on the light and control remotely.
3) TX: TX terminal transmits data signal received from RX terminal to other equipment.
TX terminal can be used for daisy chaining.
4) RX: RX terminal receives control signals from a DVR.
5) Video out: BNC connector
6) Power: 18~32V AC, 60~50Hz, 850mA
●Don't connect the power source to the middle terminal of power (Ground).
7) Power On : LED
FIG. 8-1

v DiViS 10
www.DiViS DVR.com
5. INSTALLATION
5-4. CEILING MOUNT TYPE
1) When installing the camera, make sure to install it on a ceiling that is strong enough to
support its weight, approx. 4.41lb (2kg).
2) Make a hole, Ø 5.71in (Ø145mm), on the ceiling. (FIG. 9)
Hook the safety wire to suspension and to the safety wire hold on the bracket. (FIG. 10)
3) Install the ceiling mount bracket using 4 screws – Ø 0.16in (Ø4mm) tapping screws. (FIG. 11)
4) Fix wires using cable ties. (FIG. 12)
5) Make the wires go though the square hole.
Insert mount holder and twist the camera counterclockwise. (FIG. 13)
6) Fix the camera by screwing through Lock Holder1 and Holder2. (FIG. 14)
7) Install the cover by inserting cover lock and twisting clockwise. (FIG. 15)
1 CEILING MOUNT BRACKET
CONTENTS
SUSPENSION
SAFETY WIRE
COVER HOLE
LOCK HOLDER 1
SCREW (
Ø
4.0)
CEILING BRACKET
SAFETY WIRE HOLE MOUNTING HOLE
LOCK HOLDER 1
CABLE TIE
LOCK HOLDER 2.
MOUNT HOLDER
FIG. 10
FIG. 9 FIG. 11 FIG. 12
SCREW (M3.0)
COVER
COVER HOLE
COVER LOCK
FIG. 13 FIG. 14 FIG. 15
Ø5.71in(Ø145mm)

v DiViS 11
www.DiViS DVR.com
5. INSTALLATION
5-5. EMBEDDED MOUNT TYPE
1) Prepare a Ø 7.48in (Ø190mm) hole in the ceiling board.
Fix the safety wire to a suspension to prevent camera from falling.
Other side of safety wire is fixed to the safety wire hole. (FIG. 16)
2) Fold the Lock Levers then insert the Bracket into the Ceiling Hole.
Fix the Bracket to the ceiling using screw driver. (FIG. 17)
3) Hereafter installation process is the same as the Ceiling Mount Type. (Refer to the page 10)
1 EMBEDDED MOUNT BRACKET
CONTENTS
SAFETY WIRE HOLE
FIG. 16
LOCK LEVER
LOCK LEVER
LOCK LEVER
EMBEDED MOUNT
LOCK LEVER
FIG. 17
FIG. 18
SCREW (M3.0)
Ø7.48in(Ø195mm)

v DiViS 12
www.DiViS DVR.com
5. INSTALLATION
5-6. WALL MOUNT TYPE
1) If you want to install the speed dome on the concrete wall, you need to make
4 holes with 0.49in (12.5mm) diameter by drilling as in FIG. 30. (Depth 1.46in(37mm))
2) Install SET ANCHOR BOLT on the holes.
3) Fix SET ANCHOR BOLT of the bracket using nut.
ToinstallWallMountBracket.
Tip> Select a ceiling board strong enough to hold 4 times the total weight of camera.
(Weight combined camera: approx. 11lb(5kg))
4) Screw the Bracket tightly using the wrench(M4.0) after putting the rising into the hole. (FIG. 31)
FIG. 30
4- Ø0.49in
(Ø12.5mm) Hole
<The cable into ceilin
g
> <The cable out of ceilin
g
>
FIG. 31
1 WALL MOUNT BRACKET
4 SET ANCHOR BOLT (W5/16)
CONTENTS

v DiViS 13
www.DiViS DVR.com
5. INSTALLATION
5-7. CORNER MOUNT TYPE
1) First mark the position of holes placing the corner mount bracket.
Make Ø 0.49in (Ø12.5mm) 4 holes by drill. (Depth 1.46in (37mm))
2) Install SET ANCHOR BOLT on the holes.
3) Fix the wanted bracket (wall mount bracket, gooseneck mount bracket) on the corner
mount bracket with 4ea of M10 bolt before you Install the corner mount bracket.
4) Screw the set anchor bolt of the bracket using nut on the wall.
1 CORNER MOUNT BRACKET
4 SET ANCHOR BOLT (W5/16)
4 M10 BOLT & NUT
CONTENTS
CORNER MOUNT

v DiViS 14
www.DiViS DVR.com
6. QUICK OPERATING KEYS
The dome supports Pelco-D/P and Maxpro protocols. For DiViS DVR products, please select DiViS-D
protocol for full compatibility. The dome may be used with any controllers or DVRs that support the
Pelco D and Pelco P protocols. The default setting of the dome is Pelco D / P (auto detection) with 2400
bps (baud rate).
[PELCO D/P PROTOCOLS]
The comprehensive set of features of the dome camera can be accessed with Pelco compatible
controllers via quick operation keys as defined below.
1~64 + preset and 100~200 + preset are used for normal user presets.
65-99 + preset buttons are reserved for special functions.
For example, to enter OSD MENU, press 95 + PRESET buttons
<Quick Operation Key Table 1>
Number Note Function
1~64,100~200 +Preset Preset Execute Preset 1 ~ 64, 100~200
65 +Preset Preset Status Display Preset Status
66 +Preset Auto Scan Execute Auto Scan
67 +Preset Auto Flip Toggle Auto Flip Mode(On/Off)
70 + Preset VIB CORR Toggle Picture Stabilization function (On/Off)
71~78 + Preset Group Tour Execute Group Tour #1 ~ #8
81~88 + Preset Pattern Execute Pattern #1 ~ #8
91 + Preset Zero Position Search Pan / Tilt Zero Position
92 + Preset Freeze Freeze image when camera is operating
93 + Preset BLC Toggle BLC function(On/Off)
94 + Preset Day / Night Toggle Day & Night Mode (Day / Night / Auto Mode)
95 + Preset OSD Display OSD Main Menu
96 + Preset Focus Adjust Adjust Focus
97 +Preset Alarm Toggle Alarm (Enable/Disable)
98 +Preset AUX 1 Toggle Aux1 (On/Off)
99 +Preset AUX 2 Toggle Aux2 (On/Off)
<Quick Operation Keys Table 2> : Use these function keys if these keys are available on the controller.
Menu Function
Tilt Up / Down Move sub menu cursor up / down
Pan Left / Right Enter the sub menu or change value
Focus Near Used as an Enter key.
Focus Far Used as a function changing key (usually to set coordinate)
Zoom Tele Move the status cursor to the right
Zoom Wide Move the status cursor to the left
●65 + PRESET : "Preset Status" is displayed, to exit from this screen, press Focus Near button.
●70 + PRESET : Enable / Disable picture stabilization image feature.
This feature can be only operated by preset number, and it is not included in OSD main menu.

v DiViS 15
www.DiViS DVR.com
7. DIAGNOSTIC
Standard diagnostic will be performed automatically on every camera startup.
1. PAN ORIGIN TEST
Zero point of Pan is located during the Panning test.
2. TILT ORIGIN TEST
Zero point of Tilt is located during the Tilt test.
3. TX CONNECTION TEST
The camera checks the connection with external devices such as DVR or Controller for 60 seconds.
“Ok” message will appear if it passes the TX Connection Test.
* If "Not Tested" message is displayed, some possible causes are :
- No signal has been transmitted from the DVR or Controller.
- Wrong connection configuration such as protocol, baud rate, or RS-485 connection. Check
whether or not the camera is set up properly.
4. CAMERA COMM TEST
Camera communication is also checked.
OK should be displayed in these four tests before installation.
If the camera passes all the above Tests, “NOW EEPROM CHECKING” and “ALL DATA INITIALIZING”
messages will appear, and the camera should be ready to operate.
CAMERA ID : 001
BAUD RATE : 2400 BPS
WAITING………
PAN ORIGIN TEST OK
TILT ORIGIN TEST OK
TX CONNECTION TEST OK
CAMERA COMM TEST OK

v DiViS 16
www.DiViS DVR.com
8. OSD MENU SETTING
8-1. OSD MENU TABLE
AUTO SCAN SET
START ANGLE : XXX.X.XX.X
END ANGLE : XXX.X.XX.X
DIRECTION : CW
ENDLESS : OFF/ON
SPEED : 10º/s
DWELL TIME : 03
SAVE AND EXIT
EXIT
PRESET SET
PRESET NO: 001
PRESET ID: PRESET01□□□□□□
PAN:XXX.X TILT:XX.X
SAVE
EXIT
CAMERA SET
FLICKER : OFF/ON
MIRROR : OFF/ON
APERT URE : 10
D ZOOM : OFF/ON
WBMODE : AWB MODE
PIC FLIP : OFF/ON
BLC : OFF/ON
D/N MODE : AUTO
DSS MODE : OFF/ON
EXIT
DOME SET
CAMERA ID : CAM1□□□□□□□□□
RECOVER : OFF
MANUAL SPEED : 150°/S
AUTO FLIP : OFF
ZOOM SPEED : FAST
ALARM : DISABLE
LANGUAGE : ENGLISH
[NEXT PAGE]
SAVE AND EXIT
EXIT
MAIN MENU
DOME SETUP
CAMERA SET
PRESET
AUTO SCAN
TOUR
PRAVACY
PATTERN
ALARM
SECTOR
EXIT
SECTOR SET
SECTOR NO : 01
SECTOR ID :
SECTOR01□□□
SECTOR START : XXX.X.XX.X
SECTOR END : XXX.X.XX.X
SAVE
EXIT
ALARM SET
ALARM NO. : 01
ALARM INPUT : OFF/NO/NC
ALARM ACT : 001
SAVE
EXIT
PATTERN SET
PATT NO. : 01
PATT TITLE PATTERN 01□□□
DATA FILL : 100%
SAVE
EXIT
PRIVACY SET
PRIVACY NO. : 01
DISPLAY : ON/OFF
ACTION : MOVE/ADJUST
SAVE
EXIT
TOUR SET
TOUR NO. : 01
TOUR TITLE : TOUR01□□□□□□
TOUR STEP : 01
PRESET NO : 01
DWELL TIME : 3
SPEED : 300º/S
SAVE AND EXIT
EXIT
[INITIALIZATION]
[TOUR CLEAR]
[PRESET CLEAR]
[SECTOR CLEAR]
[PRIVACY CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAULT]
[REVIOUS PAGE]
[SYSTEM STATUS]
PROTOCOL : PELCO D,P
BAUD RATE : 2400BPS
FIRMWARE VER. : X.XX
UPGRADED DATE: YY.MM.DD
CAMERA MODULE: XXXXXXXXX
[PREVIOUS PAGE]
OSD DISPLAY
CAMERA ID : OFF/ON
PRESET ID : OFF/ON
SECTOR ID : OFF ON
COORDINATE :ON/OFF
[PREVIOUS PAGE]
N
EXT PAGE
SYSTEM LOCK : OFF
[PASS WORD]
[OSD DISPLY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]

v DiViS 17
www.DiViS DVR.com
8. OSD MENU SETTING
To enter OSD Menu, press 95+PRESET buttons.
●Tilt up and down to navigate the menu, and pan left and right to make selection.
8-2. DOME SET
To enter Dome setup, move the cursor over DOME SETUP and pan left/right.
1) DOME SET - CAMERA ID
To set a camera id, move the cursor over CAMERA ID and assign a name up to 16 characters
by panning left/right. Press ZOOM TELE button to move to the status cursor to the right or
ZOOM WIDE button to move to the left. (Spaces will be displayed as )
MAIN MENU
DOME SETUP
CAMERA SET
PRESET
AUTO SCAN
TOUR
PRIVACY
PATTERN
ALARM
SECTOR
EXIT
DEFAULT SETTING
DOME SET
CAMERA ID : CAM1□□□□□□□□□□□□
RECOVER : OFF
MANUAL SPEED : 150°/S
AUTO FLIP : OFF
ZOOM SPEED : FAST
ALARM : DISABLE
LANGUAGE : ENGLISH
[NEXT PAGE]
SAVE AND EXIT
EXIT

v DiViS 18
www.DiViS DVR.com
8. OSD MENU SETTING
2) DOME SET - RECOVER
This feature allows the dome to revert to a specific programmed action when the dome stays
inactive during the recover time. These actions may be auto scan, group tour, preset, and pattern.
The recover time can be programmed from 15 second to 90 seconds. The default setting is OFF.
3) DOME SET - MANUAL SPEED
Pan/Tilt speed can be configured manually from 100º/sec up to 200º /sec.
The default setting is 150º/sec
4) DOME SET - AUTO FLIP
Auto Flip feature can be turned on/off. Pan left/right to change the setting.
This feature can also be toggled by pressing 67 + PRESET buttons.
The default setting is OFF
5) DOME SET - ZOOM SPEED
Zoom speed can be set to FAST/SLOW mode. Pan left/right to change the setting.
The default setting is FAST
6) DOME SET - ALARM
Alarms can be enabled or disabled. Pan left/right to change the setting.
This feature can be toggled by pressing 97 + PRESET buttons.
The default setting is DISABLED
7) DOME SET - LANGUAGE
Different language can be selected (English, Italian, Polish). Pan left/right to change the setting.
The default setting is ENGLISH.
8) DOME SET - [NEXT PAGE]
8-a) DOME SET - [NEXT PAGE] - SYSTEM LOCK
Configurations for the dome camera can be password protected to prevent unauthorized changes.
In order to activate [PASSWORD] page, SYSTEM LOCK must be set to ON.
The default setting is OFF.
DEFAULT SETTING
DOME SET
SYSTEM LOCK : OFF
[PASS WORD]
[OSD DISPLAY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]

v DiViS 19
www.DiViS DVR.com
8. OSD MENU SETTING
8-b) DOME SET - [NEXT PAGE] – [PASSWORD]
To enter this page to set password, pan left/right
The password must be set using preset number between 1 to 255 (Default 99)
Enter any number between 1~255 on the password area and confirm it again. If the pasword has
been properly set, “CONFIRMED” message will be displayed, and it will return to the previous
menu automatically.
<CONFIRMED> <CANCELLED>
If PASSWORD and CONFIRM do not match, “CANCELLED” message will be displayed on the
screen when you press FOCUS FAR key, “CANCELLED” will be displayed on the monitor, and it
will return to the previous page automatically.
* After a password has been set, the operator must enter the correct password in order to access
OSD MAIN MENU or to change any configurations of the camera.
* Make sure to keep record of the password as it cannot be recovered.
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM *** CONFIRMED
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM *** NOT CORRECT
DEFAULT SETTING
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***

v DiViS 20
www.DiViS DVR.com
8. OSD MENU SETTING
8-c) DOME SET - [NEXT PAGE] - [OSD DISPLAY]
This page defines which information of the camera will be displayed on OSD.
8-d) DOME SET - [NEXT PAGE] - [SYSTEM STATUS]
This page displays System information of the camera.
- Protocol and baud rate reflect current dip switch settings. (Refer to page 32, 33, and 34)
- Firmware version and Upgraded Date will be updated automatically on firmware update.
DEFAULT SETTING
OSD DISPLAY
CAMERA ID : OFF
PRESET ID : OFF
SECTOR ID : OFF
COORDINATE : ON
[PREVIOUS PAGE]
DEFAULT SETTING
SYSTEM STATUS
PROTOCOL : PELCO D, P
BAUD RATE : 2400 BPS
FIRMWARE VER. : X.XX
UPGRADED DATE : YY.MM.DD
CAMERA MODULE : XXXXXXXXX
[PREVIOUS PAGE]
Table of contents