dixell XWEB 3000 User manual

INSTALLATION GUIDE
Ver 1.1


WARNING: Use only modems supported by this monitoring
units. Dixell S.p.a can accept no responsibility for
possible damage due the usage of not supported
modems.
WARNING: Dixell S.p.a. reserves itself the right to alter this
manual without notice. The last version available
can be downloaded from the website.

INDEX
1 CHECK LIST.............................................................................5
2 TO DO LIST ..............................................................................6
3 RS 485 CONNECTION .............................................................7
3.1 The TTL output......................................................................9
3.2 Serial address of the instruments ..........................................9
4 Local connection with monitor, mouse and keyboard..............10
4.1 HOW TO SETUP YOUR NETWORK CARD .......................12
4.1.1 Windows 98 and ME TCP/IP Setup..............................12
4.1.2 Windows 2000 TCP/IP Setup .......................................16
4.1.3 Windows XP TCP/IP Setup ..........................................18
5 Modem connection (“or point to point connection”) .................23
5.1 HOW TO SETUP a dial-up connection................................25
5.1.1 Setting up dial-up connection for windows 98 ..............25
5.1.2 Setting up dial-up connection for windows me .............31
5.1.3 setting up dial-up connection for windows 2000 ...........39
5.1.4 SETTING UP dial-up connection for windows XP ........52
6 Intranet / ethernet connection .................................................66

XWEB SERIES Installation Guide
04/11/2004 1592017000 Pg. 5/74
1 CHECK LIST
•The XWEB 3000 server unit.
•One power cord for power supply connection.
•A couple of brackets.
•Quick reference manual (Fast installation).
•One serial line adapter
•One CD Rom containing the Operating manual and software

XWEB SERIES Installation Guide
Pg. 6/74 1592017000 04/11/2004
2 TO DO LIST
•Check if the power supply line match the XWEB 3000
specification (90~264 VAC 50~60Hz.).
•Connect the serial line RS 485 with the adapter provided.
•Plug-in monitor, keyboard and mouse (if needed) before turning
on the unit.
•Plug-in RJ 45 network cable (not provided).

XWEB SERIES Installation Guide
04/11/2004 1592017000 Pg. 7/74
3 RS 485 CONNECTION
To be connected to the serial line all the Dixell Modbus instruments
must be provided with direct RS485 terminals or the “TTL”-RS485
interface (XJRS485 or XJ485). Check the instrument manuals for
more information. The RS485 line is mainly based on two polarised
terminals. Please beware to respect the right sequence for all the
devices connected to the serial line.
Follow these important advises:
•The RS485 serial line must reach all the instruments where they
are installed.
•Beware to the wire polarities when screwing them into the
instrument terminals.
•The cable must have 2 or 3 wires with shield, minimum section
0,5mm2(eg. the BELDEN 8772).
•From the XWEB 3000 position the cable reaches all the
instrument positions.
•Do not execute loops or derivations:

XWEB SERIES Installation Guide
Pg. 8/74 1592017000 04/11/2004
Right connection:
Wrong connection:
•Always keep the serial cable away from power cables.
•Always keep the serial cable away from Electro-magnetic or
frequency sources.
•Do not connect shield to ground.
•Do not connect the “Gnd” terminal.
•Remember to draw a map of the line. This will help you to find
errors if something is wrong.
•The instrument with RS485 have “+” and “-“ terminals, respect
the polarity.
•To keep the line balanced it is necessary a 100 Ohm resistor at
the end of the line (you ca use the RS 485+ and RS 485-
terminals of the last instrument connected).

XWEB SERIES Installation Guide
04/11/2004 1592017000 Pg. 9/74
3.1 The TTL output
The instrument with RS485 on board do not need any kind of
external interface module. For instruments with external interface:
keep the TTL cable away from power cables or frequency sources.
The XJ485 external interface must be connected with TTL cable to
the instrument with TTL compatibility.
3.2 Serial address of the instruments
Each instrument must be defined by its unique address.
Check the address into the Adr parameter value. Take reference to
the instruction manual of the instrument itself to find the right
procedure to enter the programming and set the value.
The easiest way to work with the category functions is to set the
addresses progressively for similar groups of instruments which
have the same application.

XWEB SERIES Installation Guide
Pg. 10/74 1592017000 04/11/2004
4 Local connection with monitor, mouse
and keyboard
On the back side, the XWEB 3000 is provided with the sockets for a
monitor, a mouse and a keyboard. Please connect all the
peripherals before powering-on the unit otherwise the system may
fails to recognise them. This means that , for example, if you do not
plug the monitor cable now, you won’t see anything displayed on it
later.
The unit can also work without these three elements therefore if the
user intend to work just with the remote, he can definitively remove
them after the setup operations. In any case inside XWEB 3000 is
loaded a standard browser to allow the user setting up the unit.
If necessary check the instructions manual of each device
connected to the unit.
The operative procedure to work with XWEB 3000 is the same for
all connection method.

XWEB SERIES Installation Guide
04/11/2004 1592017000 Pg. 11/74
It is possible to connect to the unit via a single PC provided with
LAN card, by using the net connector RJ 45 (LAN). Due to the PC-
client power, this kind of connection is more suitable for the setup
procedures.
IMPORTANT: the cable between the Server and the PC must be
with crossing wires (“Bridge Cable”).
The connection procedure from the remote PC is describe in deep
in this guide. You may need some changes to your PC network
card, then you will be able to connect to XWEB 3000 via Ethernet
line. Once you have finished setting up your network card,
connection to XWEB 3000 is established simply by launching the
Browser and inserting the default IP number of the unit
http://192.168.0.200 into the address bar.
Before going on reading, please take some moments to write down
your PC network setup, may be we are going to change it. If the IP
address of your PC belong to the hierarchy 192.168.0.XYZ (where
XYZ represent a number between 1 and 254), you can reach XWEB
3000 simply plugging in the network cable.

XWEB SERIES Installation Guide
Pg. 12/74 1592017000 04/11/2004
4.1 HOW TO SETUP YOUR NETWORK CARD
Windows 98 and ME TCP/IP Setup pg.12
Windows 2000 TCP/IP Setup pg.16
Windows XP TCP/IP Setup pg.18
4.1.1 WINDOWS 98 AND ME TCP/IP SETUP
On the desktop, select My Computer -> Control Panel -> Network.
Choose the Configuration tab.
Highlight the TCP/IP associated with your Ethernet card and choose
Properties. The TCP/IP Properties window will open. On each tab,

XWEB SERIES Installation Guide
04/11/2004 1592017000 Pg. 13/74
make the following settings.
Choose the IP Address tab.
Select radio button “Specify an IP address” and compile the fields
as the image above. Then go to the DNS tab an choose the radio
button “Disable DNS”.

XWEB SERIES Installation Guide
Pg. 14/74 1592017000 04/11/2004
Go to gateway and delete any entry.

Push Ok button, Windows will ask you to make a reboot. Choose ok
and wait while system is rebooting.

4.1.2 WINDOWS 2000 TCP/IP SETUP
Go to Start -> Settings -> Network and Dial-up Connections:
following window should appear:

XWEB SERIES Installation Guide
04/11/2004 1592017000 Pg. 17/74
Right-click the network connection associated with your network
card, and then click Properties. The following window should
appear:
Select “Internet Protocol (TCP/IP)”, then properties. The following
window should appear:

XWEB SERIES Installation Guide
Pg. 18/74 1592017000 04/11/2004
Select radio button “Use the following IP address” and compile the
fields as the image above. Push “OK” button
4.1.3 WINDOWS XP TCP/IP SETUP

XWEB SERIES Installation Guide
04/11/2004 1592017000 Pg. 19/74
Click on Start button, chose Control panel, click on “Network and
internet connections” icon:
Then chose “Network connections”:
The following windows will appear:
Right mouse click on network interface icon, then chose
“Properties”:

XWEB SERIES Installation Guide
Pg. 20/74 1592017000 04/11/2004
The following windows will appear:
Other manuals for XWEB 3000
3
Table of contents
Other dixell Server manuals
Popular Server manuals by other brands

IBM
IBM x3550 - System - 7978 Problem determination and service guide

Hypermedia
Hypermedia HG9000 product manual

HP
HP t5740e - Thin Client Hardware reference guide

Nortel
Nortel 1000 Con?guration guide Installation and commissioning

HP
HP ProLiant DL385 G5p Maintenance and service guide

disguise