dixell XWEB3000 EVO User manual

QUICK INSTALLATION GUIDE

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
2/67
WARNING:
Use only modems supported by this monitoring unit. Dixell S.p.a
can accept no responsibility for possible damage due the usage
of not supported modems.
WARNING:
Dixell S.p.a. reserves itself th
e right to alter this manual without
notice. The last version available can be downloaded from the
website.
WARNING:
This is a class A product. In a domestic environment this product
may cause radio interference in which case the user may be
required to take adequate measures.

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
3/67
INDICE
1. CHECK LIST.......................................................................................... 4
2. TO DO LIST........................................................................................... 5
3. RS 485 CONNECTION ........................................................................... 5
The TTL output ........................................................................................... 7
Serial address of the instruments................................................................. 7
4. Local connection with monitor, mouse and keyboard................................. 7
HOW TO SETUP YOUR NETWORK CARD................................................. 8
Windows 98 and ME TCP/IP Setup.......................................................... 8
Windows 2000 TCP/IP Setup..................................................................13
Windows XP TCP/IP Setup.....................................................................17
5. Modem connection (“or point to point connection”) ...................................21
HOW TO SETUP a dial-up connection ........................................................22
Setting up dial-up connection for windows 98...........................................22
Setting up dial-up connection for windows me..........................................28
setting up dial-up connection for windows 2000........................................36
SETTING UP dial-up connection for windows XP .....................................49
6. Intranet / ethernet connection .................................................................63
7. Troubleshooting Guide ...........................................................................65
8. Unit Setup Reminder..............................................................................65

Quick Installation Guide
1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
4/67
1. CHECK LIST
The XWEB3000 server unit.
One power cord for power supply connection.
2 mounting brackets.
Quick reference manual (Fast installation).
One serial line adapter
One CD Rom containing the Operating manual and software

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
5/67
2. TO DO LIST
Check if the power supply line matches the XWEB3000 specification (90~264
VAC 50~60Hz.).
Connect the serial line RS 485 with the adapter provided.
Plug-in monitor, keyboard and mouse (if required) before turning on the unit.
Plug-in RJ 45 network cable (not provided).
3. RS 485 CONNECTION
To be connected to the serial line all the Dixell Modbus instruments must be
provided with direct RS485 terminals or the “TTL”-RS485 interface (XJRS485 or
XJ485). Check the instrument manuals for more information. The RS485 line is
mainly based on two polarised terminals. Please pay respect to the right
sequence for all the devices connected to the serial line.
Follow these important instructions:
The RS485 serial line must reach all the instruments where they are installed.
Make sure of the wire polarities when screwing them into the instrument
terminals.
The cable must have 2 or 3 wires with shield, minimum section 0,5mm2(eg. the
BELDEN 8772).
From the XWEB3000 position the cable reaches all the instrument positions.
Do not execute loops or derivations:

Quick Installation Guide
1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
6/67
Right connection:
Wrong connection:
Always keep the serial cable away from power cables.
Always keep the serial cable away from Electro-magnetic or frequency sources.
Do not connect shield to ground.
Do not connect the “Gnd (ground)” terminal.
Remember to draw a map of the line. This will help you to find errors if something
is wrong.
The instrument with RS485 have “+” and “-“ terminals, respect the polarity.
To keep the line balanced it is necessary a 100 Ohm resistor at the end of the line
(you ca use the RS 485+ and RS 485-terminals of the last instrument
connected).

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
7/67
The TTL output
The instrument with RS485 on board does not need any kind of external interface
module. For instruments with an external interface: keep the TTL cable away from
power cables or frequency sources.
The XJ485 external interface must be connected with a TTL cable to the
instrument with TTL compatibility.
Serial address of the instruments
Each instrument must be defined by its unique address.
Check the address into the Adr parameter value of each instruments. Take
reference to the instruction manual of the instrument itself to find the right
procedure to enter the programming and set the value.
The easiest way to work with the category functions is to set the addresses
progressively for similar groups of instruments which have the same application.
4. Local connection with monitor, mouse and
keyboard
On rear of the XWEB3000 sockets are provided for a monitor, a mouse and a
keyboard. Please connect all the peripherals before powering-on the unit
otherwise the system may fails to recognise them. This means that , for example,
if you do not plug the monitor cable in now, you won’t see anything displayed on it
later.
The unit can also work without these three elements therefore if the user intends
to work just with the remote, he can definitively remove them after the setup
operations. In any case inside the of XWEB3000 is loaded a standard browser to
allow the user setting up the unit.
If necessary check the instructions manual of each device connected to the unit.

Quick Installation Guide
1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
8/67
The operative procedure to work with XWEB3000 is the same for all connection
methods.
It is possible to connect to the unit via a single PC provided with LAN card, by
using the net connector RJ 45 (LAN). Due to the PC-client power, this kind of
connection is more suitable for the setup procedures.
IMPORTANT: the cable between the Server and the PC must be with crossing
wires (“Bridge Cable”).
The connection procedure from the remote PC is described in deep in this guide.
You may need some changes to your PC network card, then you will be able to
connect to XWEB3000 via Ethernet/ Internet line. Once you have finished setting
up your network card, connection to XWEB3000 is established simply by
launching the Browser and inserting the default IP number of the unit
http://192.168.0.200 into the address bar.
Before reading on, please take a few moments to write down your PC network
setup, there may be a need to change it. If the IP address of your PC belong to
the hierarchy 192.168.0.XYZ (where XYZ represent a number between 1 and
254), you can reach XWEB3000 simply plugging in the network cable.
HOW TO SETUP YOUR NETWORK CARD
Windows 98 and ME TCP/IP Setup pg.8
Windows 2000 TCP/IP Setup pg.13
Windows XP TCP/IP Setup pg.17
WINDOWS 98 AND ME TCP/IP SETUP
On the desktop, select My Computer -> Control Panel -> Network.
Choose the Configuration tab.

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
9/67
Highlight the TCP/IP associated with your Ethernet card and choose Properties.
The TCP/IP Properties window will open. On each tab, make the following
settings.
Choose the IP Address tab.

Quick Installation Guide
1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
10/67
Highlight as shown above, “Specify an IP address”. Then go to the DNS
configuration tab and highlight “Disable DNS”.

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
11/67
Go to gateway tab and delete any entry as shown below.

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
12/67
Push Ok button, Windows will ask you to make a reboot. Choose ok and wait for
the system to reboot.

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
13/67
WINDOWS 2000 TCP/IP SETUP
Go to Start -> Settings -> Network and Dial-up Connections:
The following window should appear:

Quick Installation Guide
1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
14/67
Right-click the network connection associated with your network card, and then
click Properties. The following window should appear:

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
15/67
Select “Internet Protocol (TCP/IP)”, then properties. The following window should
appear:

Quick Installation Guide
1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
16/67
Highlight “Use the following IP address” and compile the fields as the image
above. Push “OK” button

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
17/67
WINDOWS XP TCP/IP SETUP
Click on Start button, chose Control panel, click on “Network and internet
connections” icon:
Then chose “Network connections”:
The following windows will appear:
Right mouse click on network interface icon, then chose “Properties”:

Quick Installation Guide
1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
18/67
The following windows will appear:

1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
19/67
Select “Internet Protocol (TCP/IP)”, then click on Properties. The following
windows will appear:

Quick Installation Guide
1592010660 XWEB3000 stp GB r1.0 2009.05.08.doc dIXEL
20/67
Table of contents
Other dixell Server manuals