Designed, engineered, and
manufactured in Springfield, MO
using U.S. and global components.
LT-0842 1.03 20021
341 ENCLOSURE
Specifications
Model 341 Enclosure:
13-1/4”W x 7”H x 3-1/2”D
Optional Model 341B Battery Bracket:
5-7/8”W x 4-5/16”H x 4”D
Certifications
XT30/XT50 Series (Excludes Model 364 Battery)
ANSI/UL 1610 Central Station Burglar
ANSI/UL 1635 Digital Burglar
XT30/XT50 Series (Using Model 364 Battery and 341B Bracket)
ANSI/UL 1610 Central Station Burglar (Mercantile only)
ANSI/UL 1635 Digital Burglar (Mercantile only)
XR150/XR550 Series (Excludes Model 364 Battery)
ANSI/UL 294 Access Control System Units
ANSI/UL 636 Holdup Alarm Units and Systems Accessory
ANSI/UL 1076 Proprietary Burglar
ANSI/UL 1610 Central Station Burglar
ANSI/UL 1635 Digital Burglar
ULC/ORD-C1076 Proprietary Burglar
ULC S304 Central Station Burglar
XR150/XR550 Series (Using Model 364 Battery and 341B Bracket)
ANSI/UL 294 Access Control System Units
ANSI/UL 1610 Central Station Burglar (Mercantile only)
ANSI/UL 1635 Digital Burglar (Mercantile Only)
INTRUSION • FIRE• ACCESS• NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
800-641-4282 | DMP.com
2. Connect the 318T Black battery lead to Terminal 4 and the negative battery terminal. The negative
terminal connects to the enclosure ground internally through the panel to the circuit board.
3. Connect the 318T Red battery lead to Terminal 3 and the positive battery terminal. Observe polarity
when connecting the battery.
Note: Use sealed lead-acid batteries only. Use 12 VDC sealed lead-acid rechargeable battery. Batteries
supplied by DMP have been tested to ensure proper charging with DMP products.
The 341 enclosure can be used as a system enclosure when the XR150/XR550 or XT30/XT50 Series panel is installed.
AC
1 2 3 4
+BAC –B
318T Battery
Harness
Red and
Black Battery Cables
Model 364
Battery
Model 364
Battery
5 6
BELL GND
To AC
14 AWG to
Earth Ground
Panel
PTC
To Bell
Circuit
Figure 4: Wiring Multiple Batteries
LISTED COMPLIANCE SPECIFICATIONS
31. Connect the two batteries using the DMP Model 318T Dual Battery Harness.
Caution: DMP requires each battery be separated by a PTC in the battery harness wiring to protect each
battery from a reversal or short within the circuit. See Figure 4 for proper wiring.
CONNECT THE BATTERIES TO THE PANEL