About this quick guide
Validity
This quick guide describes the product:
Product designation dormakaba registration unit 90 01
Product ID 9001-K6
Item number 04079003
Date of manufacture From February 2020
Target group
This quick guide should only be used by skilled persons trained by
the manufacturer.
Supplementary documentation
The registration unit operates as a peripheral component to a par-
ent control unit. The essential system functions can therefore be
found in the technical manual for the parent unit.
Additional documentation is available on the Internet at the
dormakaba website. The technical manuals are located in a protec-
ted area. They can be accessed via the user account of trained pro-
fessionals. However, you can also create a temporary account.
https://www.dormakaba.com/extranet-emea-en
Safety instructions
Designated use
This product is intended for use as specified and explained in the
Product description section only. Any other use is considered non-
designated use. The manufacturer is not liable for any damage or
injury due to non-designated use. The user/facility operator is the
sole person to bear risks for non-designated use.
Staff qualification
The actions described in this quick start guide must only be carried
out by skilled persons in accordance with EN 62368-1.
Skilled person is the designation for people who have the appropri-
ate technical training and experience in setting up the equipment.
Skilled persons are expected to use their training and experience to
identify any risks to themselves and others that may arise while
carrying out these activities, and to minimise these risks as far as
possible. It is the skilled person’s responsibility to ensure that the
conditions stated by the manufacturer and the applicable regula-
tions and standards are complied with when carrying out these ac-
tions.
Assembly and installation
The product should only be installed in locations which fulfil the en-
vironmental and technical conditions specified by the manufac-
turer.
The manufacturer is not liable for damage arising due to improper
handling or incorrect installation.
Environmental protection
Do not dispose of the product in your domestic waste, but have it
recycled.
ESD protective measures
NOTICE
Danger for electronic components due to electrostatic discharge.
Improper handling of printed circuit boards and components may
cause damage leading to complete failure or malfunction of the
device.
• Applicable ESD protective measures must be observed and ap-
plied when using electronic components.
Product description
The registration unit is a remote reader for authorization checking
within an access control system.
The registration unit enables the contactless reading and writing of
RFID media as well as access via a smartphone (Mobile Access).
The registration unit supports the following technologies:
• RFID MIFARE DESFire/Classic
• RFID LEGIC advant/prime
• NFC (Android Smartphone)
• Bluetooth Low Energy (Android Smartphone + iPhone)
The actually usable technologies depend on the system solution in
which the registration unit is integrated.
The registration unit is connected to a superior control device using
a coaxial cable.
The registration unit is installed directly on the wall in the door
area.
The registration unit is equipped with a light icon (red/green) and a
buzzer for optical and acoustic signalling.
Product versions
The product is available for the following installation variants:
• back housing (19,4 mm) for flush cable mounting
• back housing with spacer frame (26,4 mm) for surface cable
mounting
The product is available in the following color variants:
• Black/white aluminum (RAL9005/9006)
• White/white aluminum (RAL9016/9006)

dormakaba registration unit 90 01Quick Guide
2/4 04047655 - 01/2020
Technical data
Power supply
The registration unit is supplied with power by the superior control
device via the coaxial cable.
The power supply source of the superior device must meet the fol-
lowing requirements: LPS (Limited Power Source) and SELV
(Safety Extra Low Voltage) in accordance with IEC/EN/UL/CSA
60950-1 or ES1 and PS1 in accordance with IEC/EN/UL/CSA
62368-1.
Interface
• Encrypted data transfer
Connecting cable
• Coaxial type RG 174/U
• Impedance 50 Ohm
• Cable length: min. 1 m; max. 30 m
Dimensions
Dimensions in millimetres
Ambient conditions
• Ingress protection according to IEC 60529:
– IP40 for surface cable mounting with spacer frame
– IP54 for flush cable mounting with back housing and seal-
ing mat
• Relative humidity: 5% - 85%, non-condensing
• Ambient temperature:
– -30 °C – +70 °C (operation)
– -40 °C – +85 °C (storage)
Conformity
The product complies with the provisions of the EU directives
2014/53/EU - Radio Equipment Directive (RED)
2011/65/EU - Restriction of Hazardous Substances (RoHS)
You can download the original declaration of conformity in
PDF format at www.dormakaba.com/conformity.
Installation
Installation conditions
Installation site
The registration unit is installed in an ergonomically suitable posi-
tion, for example in the access area (door). The registration unit is
mounted to a socket for flush mounting or cavity wall mounting
with a screw distance of 60 mm. The cable entry takes place from
the back. The optional back housing with spacer frame allows sur-
face cable mounting with cable entry from below or from the side.
When installed on a metallic surface, the higher back housing with
spacer frame must be used.
The product is designed for the stationary use in buildings. The
product is not suitable for the use in vehicles.
Distances
RFID fields which are close together can influence one another,
thereby reducing the reading and writing distances. A distance of
20 cm must be maintained on all sides between two registration
units which are not in operation on the same control unit.
In Mobile Access systems, minimum distances between registration
units and other Mobile Access components must be observed in or-
der to avoid overlapping the Bluetooth coverage. Details can be
found in the Mobile Access Planning Guideline (04046728).
Installation height
The recommended installation height is 110 cm from the top edge
of the registration unit.
The mounted height for the terminal should not be higher than 2
meters.
Electromagnetic fields
Do not install the registration unit in the vicinity of strong electro-
magnetic fields caused, for example, by switched-mode power sup-
plies, electric power lines, phase control etc. Electromagnetic fields
can adversely affect read performance or cause malfunctions, es-
pecially in the case of contactless RFID readers.
Connecting cable
Permissible length of the coaxial cable to the parent control unit:
• minimum 1 m
• maximum 30 m
The installation cables must be flush-mounted or mounted in the
tamper-proof area.
To avoid external interferences, the coaxial cable must not be laid
parallel to power lines or other sources which are prone to disturb-
ance.
Fastening the registration unit
Principle
The registration unit consists of a back housing and an operating
unit with electronics. The back housing is mounted on surface. The
plug-in terminal is located on the back housing. Thanks to the
quickwire technology, the complete wiring is separated from the
electronics on the back housing. The electronics is placed on the
back housing prior to start-up.

dormakaba registration unit 90 01 Quick Guide
04047655 - 01/2020 3/4
Flush cable mounting
To achieve the ingress protection to IEC 60529 specified in the
technical data, the back housing must be mounted to the de-
livered black sealing mat (2). It is used to balance out any un-
evenness and to improve water resistance.
The back housing (1) is mounted on a flush-mounted or cavity wall
switch box using suitable fastening screws (not included in the
scope of delivery). The cable entry takes place from the back.
Surface cable mounting
For surface cable mounting, the cable entry can take place from
below or from the side. First the respective cut-outs in the back
housing with spacer frame (1) must be produced. A loop (siphon)
should be provided, so that no water can enter. The back housing
with spacer frame (1) can be screwed or glued to the surface.
Connecting the coaxial cable
Terminal Connection
6 Shield of coaxial cable (S)
7 Central conductor of coaxial cable (+)
Switch settings
On the back of the front panel there is a switch bank for setting
the received signal strength (RSSI value).
This switch bank can be used to set or limit the range of Mobile Ac-
cess via Bluetooth Low Energy (BLE).
1 2 3 4 RSSI [dBm]
OFF OFF OFF OFF BLE OFF
ON OFF OFF OFF -30
OFF ON OFF OFF -32
ON ON OFF OFF -34
OFF OFF ON OFF -35
ON OFF ON OFF -36
OFF ON ON OFF -37
ON ON ON OFF -39
OFF OFF OFF ON -42
ON OFF OFF ON -47
OFF ON OFF ON -53
ON ON OFF ON -60
OFF OFF ON ON -74
ON OFF ON ON -94
OFF ON ON ON -111
ON ON ON ON -128
The RSSI value can be changed if necessary. Higher values allow
the recognition of smartphones over longer distances. Smaller val-
ues reduce the range and increase safety. A compromise between
security requirements and operability is recommended.
Final mounting
Place the front panel with electronics on the back housing as fol-
lows:
NOTICE! If proceeding incorrectly, the pin header may become
damaged!
1. Slide front panel in parallel onto the back housing.
2. Press the front panel against the back housing, until it audibly
locks into place at the top and bottom.
3. Remove the protective film.

dormakaba registration unit 90 01Quick Guide
4/4 04047655 - 01/2020
dormakaba EAD GmbH | Albertistraße 3 | 78056 Villingen-Schwenningen | Germany
T: +49 7720 603-0 | www.dormakaba.com | Company headquarters: Villingen-Schwenningen
Removing the registration unit
The snap-lock connection allows you to quickly remove the front
panel from the back housing.
NOTICE! If proceeding incorrectly, the pin header may become
damaged!
1. Insert a screwdriver with a narrow blade (no. 1) into the open-
ing below the frame and press it upwards.
ðThe snap lock disconnects.
2. Swing the front panel slightly open at the bottom (max. 10°).
3. Pull the front panel in parallel away from the back housing.
Putting into operation
Put into operation and carry out the functional test in accordance
with the control unit instructions.
Operating elements
1 Acoustic signal transmitter
2 Optical signal transmitter
(illuminated ring)
3 Input area RFID / NFC
Operating sequences
The exact operating sequences are determined by the higher-level
control system. The following descriptions refer to default settings.
Signaling
The operator is guided by optical and acoustic signals.
Signaling Meaning
green permanent in attendance
red permanent access blocked
green
short acoustic signal access authorised
red flashing
short acoustic signals access not authorised
Booking with RFID media
The contactless media are held in front of the input field as follows.
Access with Smartphone (Mobile Access)
Start 'dormakaba mobile access' app on the smartphone and
touch the key.
Bluetooth applications NFC applications
Bring smartphone into the
Bluetooth range. Hold the smartphone in front of
the input field.
Observe the position of the NFC
antenna in the smartphone (see
manual of the Smartphone).
Cleaning the housing
To clean the housing, use a soft, lint-free cloth and a mild window
cleaning agent!
NOTICE
Damage to the housing because of inappropriate cleaning agents
Observe the following instructions in order to avoid damaging the
housing during the cleaning process:
• Do not use alcohol, such as ethanol or isopropanol
• Do not use aggressive solvents
• Do not use cleaning agents with added powder
• Avoid scratching and abrasive movements