Drainvac Atomik User manual

*** Open the lid of the vacuum cleaner before using.***
OWNER’S MANUAL

1
INTRODUCTION
We take this opportunity to express our gratitude and extend our
congratulations for your decision to purchase a Drainvac product.
There’s a judicious investment you will enjoy for many years. The Drainvac
Atomik central vacuum cleaner is built with the bests components available
on the market. They are manufactured and tested in our plant by a qualified
and specially trained staff. However some installation and operation
procedures must be followed to insure maximum performance and to avoid
needless service calls. Please read the following carefully.
REGISTRATION
You must register your Drainvac Atomik vacuum cleaner on our
website at this following address (www.drainvac.com/registration) to
cover your warranty.
WARNING
Owner read carefully
· Disconnect all electrical power to the wall area before installing!
· Unplug before attempting maintenance or cleaning.
· Unplug from electrical outlet when not in use and before servicing.
· Do not use with damaged cord or plug.
· Do not operate the vacuum cleaner if damaged.
· Do not modify any part of the vacuum cleaner.
· This vacuum cleaner is intended to be in a vertical position or floor
mount position.
· Never vacuum flammable matters, gaseous or liquid, with your system.
· Never vacuum ash from your fire place and from ashtrays.
· Do not pick up anything that is burning or smoking, such as cigarettes,
matches or hot ashes.
· Keep away from rain, snow or excessive moisture.
· Filter and dust bag must be installed in the unit all the times.
· Use only the manufacturer’s attachments, filters and dust bags.
· Do not place objects in front of the vacuum cleaner.
· This vacuum cleaner should not be used by children without supervision.
Drainvac International Inc accepts no responsibility if you contravene
these directives.

2
TABLE OF CONTENTS
Tools required page 3
Equipment page 4
STEP 1 : Remove the unit from the packaging page 5
Unit dimensions page 6
Minimum space required page 7
Unit installation page 8
Installation of the Activac1 exhaust filter page 9
Installation, ready to use page 10
Installation on a piping network page 11
Electrical installation page 12
Maintenance & cleaning procedures page 13
WEEE directives page 14
Trouble shooting page 15
Kits A-B-C page 16
Accessories - Filters - Dust bags page 17
Warranty page 18

3
TOOLS REQUIRED
Phillips screw driver (star) Flat screw driver
2.25 ’’ – 57 mm 0.5’’ – 12,5 mm
Measuring tape Hole saw Hand drill
Mitre box & saw or Pipe cutter
Pair of pliers Pair of cutters

EQUIPMENT
4
Entry
Exhaust
Power cord
North America 120V
International 240V
Breaker - Fuse
North America 120V
International 240V
GreenLED
On/Off button
On ‘’I’’ position
Off ‘’O’’ position
24 volt
Clamps
2 x Dust bags
(One without zipper
& one with zipper)
8’’(20cm) diam.
Polyester filter
4 x collar
Activac 1
exhaust filter
Utility inlet
PVC coupling
90˚medium
ABS elbow
Owner’s
manual
4 x #1 screws
1 foot (30cm)
24 volt wire with
connectors
Wall bracket

5
STEP 1
1 - Detach the clamps, remove the lid and take off the plastic bag.
(The plastic bag included equipment for the installation of the unit. Keep it near the unit).
2 - Make sure the polyester filter and dust bag are properly installed.
3 - Replace the lid on the unit and attach the clamps.
*** Open the vacuum cleaner before using.***
*** Remove the Drainvac Atomik vacuum cleaner
and the equipment from the packaging.***

6
15.5’’
(39.5cm)
9.75’’
(24.75cm)
11’’
(28cm)
UNIT DIMENSIONS
Front view
Side view

7
Min.1’’
(2.5cm)
Min.12’’
(30.5cm)
Min.9’’
(22.75cm)
Min.12’’
(30.5cm)
Min.18’’
(45.75cm)
MINIMUM SPACE REQUIRED TO INSTALL THE UNIT
Front view
Side view
Install the unit near
an electrical outlet.
120 volt, 15amps
240 volt, 16amps

8
#1 ( 1.25’’ - 30mm )
A
B
Wall hanger
UNIT INSTALLATION
How to install the unit?
1- Remove the wall plate that is attached to the back of the unit using the
pair of cutters.
2- Fasten the wall plate to the wall using the 4 x #1 screws included
with the unit.
3- Lift the unit and install the top part (A) of the unit bracket behind the
top part of the wall plate. At the same time, install the bottom part (B)
of the unit bracket inside of the bottom part of the wall plate.
Cut strap
with the pair of cutters
Phillips screw driver (star)

9
INSTALLATION OF THE EXHAUST FILTER
Flat screw
driver
90˚ medium
abs elbow
Activac 1
exhaust filter
Flat screw
driver
Collar
Collar

1
2
10
PVC coupling
DRAINVAC ATOMIK, READY TO USE
2 x Collar
Utility inlet
1 foot (30cm)
24 volt wire with connectors.
Flat screw driver
Phillips screw driver (star)

11
INSTALLATION ON A PIPING NETWORK
In a condo, in a garage, in a RV, in the mecanic room...
24 volt wire
Example : RV installation
Power outlet

12
Type B
Type I
Nema 6-15(220v)
Type G
Type E
The Drainvac Atomik vacuum cleaner is equipped with one electrical cord.
An adequate electrical power outlet must be installed close to the unit.
We strongly recommend installing an electrical circuit that will be used
only by the unit.
North American model : ATOMIK6 require an 15 amps/120 volt circuit.
International model : ATOMIK60 require an 16 amps/240 volt circuit.
Also plan the 24 volt between the unit, the piping system and the inlets.
ELECTRICAL INSTALLATION

13
Image A
Image B
Image B
MAINTENANCE AND CLEANING PROCEDURE
All mechanical systems require a minimum of maintenance, your system is
not an exception. Beyond the occasional external cleaning, we recommend
a complete inspection of the motor brushes after 500 hours of usage.
(1000ft /100 m2 represents 1 hour of usage for each use).
For a house approximately 2500 sq. ft./ 250 sq. m.
On average, the frequency of inspection is once every 3 to 5 years.
Also you must change the polyester filter & the dust bag periodically. This
will stabilise the efficiency of the unit and will cut down from 5 to 6 times
the maintenance of your unit.
Cleaning procedure :
1 - Detach the clamps, remove the lid from the unit.
2 - Remove and discard the dust bag and the polyester filter.
If you use a dust bag with a zipper, you can re-use it a few time all depending on the use
(Image A). The misuse of this bag may invalidate the warranty.
3 - Install a new dust bag & polyester filter (Image B).
You can install the zipper bag if the above conditions are respected.
4 - Reattach the lid to the main unit.
* IF THE UNIT IS USED WITHOUT ITS FILTERS, THE WARRANTY WILL BE VOID.
Lid
Dust bag
(With or without zipper)
Polyester filter
Clamps
Main unit

WEEE DIRECTIVE
14
WEEE
This appliance has been assessed in accordance with the European
Parliament Directive on Waste Electrical and Electronic Equipment,
usually referred to as the WEEE Directive.
The WEEE Directive requires that the appliance be disposed of at the end
of its useful life an in environmentally responsible manner. Parts and
materials should be re-used or re-cycled in order that the use of new
resources and amount of waste going for landfill be minimized.
The WEEE Directive stipulates that the supplier should collect the used
item without cost to you. Please inform the supplier of your wish to have
the old appliance collected when ordering the new replacement.
If you wish to dispose of the appliance yourself, do not mix it with unsorted
municipal waste. The crossed-out wheeled bin symbol on the unit label
indicates this requirement. You must ensure that the appliance is
disposed of at an authorized treatment facility. Details can be obtained
from your local council.

15
IMAGE D IMAGE E
IMAGE C
TROUBLE SHOOTING
PROBLEM : The unit will not start
1 - Check the circuit breaker on your electrical panel.
2 - Check the circuit breaker of the unit. ( Image C1 )
3 - Check the 24 volt circuit:
To check the 24 volt circuit, proceed as follow ;
- Establish the contact between the two ports of a wall mounted air inlet
valve with a piece of metal (ex. coin ( Image D )). If the system starts, the
suction hose is defective. See your dealer.
- If the system does not start check the 24 volt wires on the unit ( Image C2 );
Establish the contact between the two screws of the 24 volts circuit plate
using a piece of metal (ex. Screw driver ( Image E )). If the unit starts,
the 24 volt wire is either cut OR unplugged from one of the wall mounted
air inlet valves.
- If the system still do not start after steps 1, 2 and 3, the printed circuit is
defective. Call your dealer.
PROBLEM : The unit will not stop
Check the 24 volt circuit as follows ;
- Disconnect one of the two 24 volt wires on the unit ( Image C2 ). If the
unit stops, the two wires are in contact somewhere in the circuit OR
a wall mounted air inlet valve is defective.
If the unit does not stop, the printed circuit is defective. Call your dealer.
NOTE : If you notice a vibration coming from the motor, call your dealer.
Coin
24 volt wire
(2) Breaker
(1)

KITS
16
ZIP1021 ZIPBROOM kit
TGA30-6 Econo kit
KIT130C DELUXE kit
20’ (6m) extensible hose
+ tools, hose hanger and handle
30’ (9m) regular hose
+ brush, tools kit, hose hanger
& telescopic handle
30’ (9m) on/off hose
+ brush, tools kit, accessory hanger
& telescopic handle

17
ACCESSORIES
• Rotating carpet brush
• 1 x Polyester filter &
3 x Dust bags by pck.
(Choice with or without zipper)
• 1,2 or 3 inlet installation kit
• Utility inlet
• Hose cover
• Activac 1 filter
• Dustpan installation kit
• Extra screws & wall hanger
#1 screws
( 1.25’’ - 30mm )
All illustrations, specifications, colors and photographs shown may vary. While Drainvac International takes
care to ensure that the information contained in this publication is accurate, it cannot guarantee complete
accuracy. Drainvac International is not responsible for errors or omissions contained in this publication.

COMMERCIAL *see conditions
1 year for : Motor - Parts - Caissing - Labor
1 year for accessories
18
WARRANTY
RESIDENTIAL *see conditions
5 years for : Motor - Parts - Caissing - Labor
3 years for accessories
* Conditions for the residential warranty :
- Excludes the motor brushes.
- Labor at the dealer store or plant
- Freight at the customer’s expense
- Have purchase invoice
* Warning, the service call made by dealer is at the customers expense.
* Conditions for the commercial warranty :
- Excludes the motor brushes.
- Labor at the dealer store or plant
- Freight at the customer’s expense
- Have purchase invoice
* Warning, the service call made by dealer is at the customers expense.
If you wish to speak to a service agent, please contact your retailer
or Drainvac International Inc
Monday to Friday from 9am to 4pm (eastern time) at :
T : 1 800 408-1448 • (450) 467-1448
F : 1 877 408-2225 • (450) 467-2225
info@drainvac.com • www.drainvac.com
http://www.youtube.com/drainvacchannel
Warranty covers any defect in material or workmanship produces
by Drainvac International Inc. It excludes damage caused by normal
wear and tear, misuse & modification.

.com
OWNER’S MANUAL
DRAINVAC ATOMIK • PRINTED APRIL 4 -2011
th
Other manuals for Atomik
1
Table of contents
Other Drainvac Vacuum Cleaner manuals