DRI BEAST SIM Series User manual

Dri Beast
DRI BEAST
LGR DEHUMIDIFIER OWNER’S MANUAL
SIM SERIES

English
-1-
Dri Beast - LGR dehumidifier
Operation and Service Instruction SIM-75, SIM-95, SIM-110
Owner's Manual
Dri Beast LGR Dehumidifier
SIM Series
115-volt model
Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to
comply with instructions could result in personal injury and/or property damage!
Retain instructions for future reference.
If the unit needs repair, have the repairs fixed by a qualified
technician; problems caused by an unauthorized person will void the warranty.
Never attempt to disassemble or alter the unit in any way not instructed
by this manual. Electric shock may occur, resulting in injury or death.
IMPORTANT!
DANGER!
DANGER!
Do not handle the plug with wet hands. Electric shock may occur,
resulting in injury or death.
CAUTION!
Do not block the grids when the unit is in use. Keep metal objects away
from the unit. Bodily injury or property damage may occur.
WARNING! Humidity sensor is easily damaged when used in gaseous locations.
READ AND UNDERSTAND THESE INSTRUCTIONS
1. Read all instructions before using this unit. Save these instructions for reference.
2. Do not use this unit outdoors. It is intended for indoor use only.
3. Do not allow children to play near the unit.
4. Do not use adaptors.
5. Inspect the power cord before use. If cord is damaged, do not use. Always grasp the plug
(not the cord) to unplug.
6. Always unplug the power cord from the receptacle when the unit is not in use, before
cleaning, replacing parts, etc.
7. Keep motor and wiring dry.
8. The maximum temperature indicated on the rating plate is relative to measurements made
in normal operating conditions. These must be observed.
9. When the unit is set up for continuous drainage, make sure the hose is connected properly
and is able to flow freely.
10. Continuous drainage is not recommended when the temperature is below freezing.
11. Do not use the unit as a bench or table.
12. It must always be used in the upright position.
INFORMATION EMAIL: info@dri-beast.com

-2-
English
INTRODUCTION
The Dri Beast LGR dehumidifier series is designed with the end user in mind and provides
outstanding performance. Our LGR technology helps remove moisture, eliminate mildew,
musty odors, sweating on walls and windows, in the most demanding of environments.
We offer three different size beasts which help you to solve your most demanding problems
in any size room or building.
What's in the box
1. Dri Beast LGR SIM Dehumidifier
2. 20-foot drainage hose
3. 10-foot power cord
4. Owner's manual
Unpacking and Inspection
Handle carefully. Check the packing list to account for all items. Visually inspect for
shipping damage. If damaged, immediately file a claim with the carrier.
FRONT OF THE UNIT(Figure 1)
1. Filter
2.Wheel
3. Base
4. Front Panel
5. Inlet grid
BACK OF THE UNIT (Figure 2)
1. Handle
2. Air outlet
3. Water outlet
4. Power plug
5. Power cord storage
6. Control panel
5
4
3
1
2
Figure 1
6
3
1
5
42
Figure 2
Dri Beast - LGR dehumidifier

English
Specification
SIM-75
SIM-95
SIM-110
Rated Voltage
Capacity
Model Temperature Range Rated Power
760W
910W
1100W
860W
1030W
1220W
1140W
1380W
1650W
SIM-75
SIM-95
SIM-110
Model Rate Amps
6.9A
8.3A
10.1A
7.8A
9.5A
11.1A
10.2A
12.5A
14.8A
Display Range
30-90%RH
30-90%RH
30-90%RH
24.0"x23.0"x37.7"
(610x584x957mm)
24.0"x23.0"x37.7"
(610x584x957mm)
24.0"x23.0"x37.7"
(610x584x957mm)
Dimensions (WxDxH)
119lbs(54kgs)
128lbs(58kgs)
130lb(59kgs)
Weight
Dri Beast refrigerant dehumidifiers operate by pulling moist air in across a very cold
evaporator core. The moisture condenses (freezes) on the coil. At intervals, the machine will go
into defrost mode, warming the frost back to water. The water collects in a tray and leaves the
unit through a drain hose or pump.
HOW THE LGR UNIT WORKS
IMPORTANT! Before moving the unit, make sure there's no water in the pump.
For best results, operate your dehumidifiers in an enclosed area, as this creates a drying
chamber. Close all doors and windows that open to the outside to maximize the unit's water
removal efficiency. Also, keep traffic though the drying chamber to a minimum. Place your
dehumidifier against a wall, away from obstructions, and keep it away from anything that
could block airflow into and out of the unit.
POSITIONING THE LGR UNIT
-3-
Dri Beast - LGR dehumidifier
75Pt(36L)(80℉/26.7℃/60%RH)
130Pt(62L)(86℉/30℃/80%RH)
180Pt(85L)(86℉/30℃/100%RH)
95Pt(45L)(80℉/26.7℃/60%RH)
160Pt(76L)(86℉/30℃/80%RH)
228Pt(108L)(86℉/30℃/100%RH)
110Pt(52L)(80℉/26.7℃/60%RH)
187Pt(88L)(86℉/30℃/80%RH)
288Pt(136L)(86℉/30℃/100%RH)
41℉~90℉
5℃~ 3 2℃
41℉~90℉
5℃~ 3 2℃
41℉~90℉
5℃~ 3 2℃
115V/60Hz
115V/60Hz
115V/60Hz

English
1. Your dehumidifier is designed for easy use and maintenance. Make sure that the filter is
properly installed before use.
2. Keep the unit's air inlet and outlet grids at least 4 inches away from any wall.
3. Select a flat, stable surface to place the unit. Do not place on or near heat sources such as
stoves, radiators, or heaters, or in direct sunlight.
4. Do not use the unit in places where chemicals are stored. Volatile chemicals might damage
the unit and make the pump leak.
NOTE: Do not tilt the unit move than 45 degrees to avoid damaging the compressor.
NOTE: If you transport an SIM-Series dehumidifier in a horizontal position, set it upright and
let it stand for at least 30 minutes before you turn it on. When the machine is horizontal, the oil
from the compressor flows into the refrigerant coils reducing the ability of the dehumidifier to
function. Letting the unit stand upright for 30 minutes allows the oil to flow back into the
compressor.
SET UP YOUR LGR DEHUMIDIFIER
1. Dehumidify indicator
2. Tank full indicator
3. Defrost indicator
4. Fan indicator
5. Accumulative run time
6. Drain button
7. Humidity up and down buttons
8. On/Off button
9. Humidity% display
CONTROL PANEL
-4-
Dri Beast - LGR dehumidifier

English
-5-
Dri Beast - LGR dehumidifier
OPERATING YOUR DEHUMIDIFIER
IMPORTANT: Always unplug the unit before moving or servicing. Use only the
ON/OFF button to turn the unit on and off.
1. Plug the power cord into a power outlet. Di appears on the HUMIDITY% display.
2. Press the ON/OFF button to turn the unit on. The previous humidity setting appears
on the display, then the current humidity appears.
3. Press the HUMIDITY UP or DOWN button to choose the desired humidity. Pressing
the button for 1 second raises the setting in increments of 1%; holding for 2 seconds
or more raises the setting in increments of 5% every second. If the humidity setting is
less than 30%, the unit runs constantly and CO appears on the display.
4. Press the drain button to empty water automatically from pump reservoir.
OPERATING TIPS
1. When the humidity setting is higher than the current room humidity, the unit will not
run. Maintaining the humidity between 45-65% is suggested for best results.
2. When dehumidifying, the fan motor and compressor must run for at least 3 minutes.
NEVER attempt to restart the compressor again within 3 minutes after shutting the
unit off.
3. When operating in low temperatures, the unit automatically determines when it needs
to defrost. When defrosting, the DEFROST indicator comes on and the compressor runs.
The fan motor is not used for defrost.
4. The pump automatically removes the water if the tank is full.
5. Accumulative work time on the display indicates the total number of hours the unit
has been operated.
MAINTENANCE
WARNING! ELECTRIC SHOCK HAZARD.
Unplug the dehumidifier
before performing any maintenance. Do not immerse in water or any other liquids.
Before Each Use
Inspect the electrical cord for damage. Look for fraying, cuts, etc. Do not use the unit if
you find any. Call your supplier for the nearest Service Center.
Inspect filter. Look for accumulated dust and dirt that would restrict airflow through the
filter into the unit. If any is visible, vacuum out the debris. Do not wash the filter, as it will
reduce the effectiveness of the electrostatic material.

English
-6-
Storage/ After Each Use
Wipe the enclosure, control panel, and cord with a damp cloth or sponge.
The outlet grid should simply be dusted. It should not be immersed in water.
Use pump Drain button to empty water.
Walk out the hose to drain it completely.
Remove the inlet filter and using gas to blow off the dust on the surface. Do not
rinse or wash the filter. Make sure the filter is completely dry before reinstalling.
Take out the filter
1. Screw out two nuts from front housing, and take off inlet
grid to get the filter. (Figure 3)
2. Clean the filter with a vacuum cleaner.
3. Place the filer back in the unit.
Cleaning The Filter
Filter should be cleaned once for a month and replace the filter after using for 12 months.
Only need to blow off the dust to cleaning the filter.
To extend the life of the filter when the unit is not sued for a long time, put the filter in a
plastic sealable bag.
ERROR MESSAGES REQUIRING SERVICE
The following table lists possible error codes that may appear in the HUMIDITY% display
if the unit detects a problem. In this event, the unit may need service.
Humidity sensor may need service
Pump may need service
Defrost sensor may need service
Malfunction display
E3
E4
E5
Problem
Figure 3
Screw out two nuts
Dri Beast - LGR dehumidifier

English
-7-
Dri Beast - LGR dehumidifier
Please provide following information:
- Model number
- Serial number
- Part description and number as shown in parts list
Repair Parts List
Filter
Humidity sensor
Pump
Wheel
Reference # Description Part Number Quantity
11
36
26
28
1
1
1
1
Replacement Parts - call your Supplier
SGD-LGR-A011
SGD-LGR-A036
SGD-LGR-A026
SGD-LGR-A028

English
-8-
TROUBLESHOOTING
When the above malfunctions occur and the unit must be repaired please contact your
supplier - do not disassemble the unit.
Hot wind from the air outlet is normal.
Symptom
The dehumidifier will
not turn on
Reduced air flow or poor
dehumidifying efficiency
Water leaks from the unit
Possible Causse(s)
1. Bad fuse
2. No Power
1. Inlet grid or outlet grid may be
blocked
2. The filter may be clogged
3. Doors or windows in the room
are open
4. There is a leak in the refrigerant
1. The unit may be unstable or not
upright
2. The pump or draining hose is
clogged
Corrective Action
Replace the fuse
Check power supply to the
unit
Check that nothing is in front of
or in back of the dehumidifier
Clean the filter or replace it, if
necessary
Close the doors and windows
The unit may need service
Make sure the unit is stable and
level
Check the pump or draining hose
M5 nuts (pre-installed)
Duct ring
M5X12screws
OPTIONAL PARTS - Air outlet duct ring
Dri Beast - LGR dehumidifier

-9-
Dri Beast - LGR dehumidifier
NOTES
English

-10-
Dri Beast - LGR dehumidifier
NOTES
English

This manual suits for next models
3
Table of contents