Thank you for purchasing the Dryco Drain Kit.
Unlike conventional pool covers, it is very important that you do not lower the water level in your pool before
installing the Dryco Drain Pool Cover. The water level must be kept higher than the inlet in the side of the pool.
If you are in an area where freezing conditions might occur, you will have to winterize your skimmer basket. There are
many ways to achieve this. You will need to consult your pool store to see which way is best for you. The Dryco Drain
does not protect your skimmer basket from freezing and possibly bursting.
Leaves may fall onto the cover. Normally, since the cover stays dry, the wind will blow the leaves off. If your cover
should collect leaves, you may use your pool brush with an extension pole to remove them.
Warning:
After installing the Dryco Pool Cover Drain in your cover, please follow the
safety guidelines that come with the cover.
If the drain should collect leaves or debris, DO NOT ATTEMPT TO
CRAWL ON, LEAN ON OR REACH OUT OVER THE COVER TO
REMOVE IT. Use the pool brush with extension pole to remove them.
The Dryco Pool Cover drain is not intended to be used for any other
application other than installation in a pool cover.
Following these guidelines will ensure that you will enjoy the use of your Dryco Drain for many years to come.

Installation
Instructions for
Dryco Pool Cover
Drain Into Cover
Step 1: Find and mark the center
of the cover
Step 2: Position the rubber gasket on
top of the drain. The gasket has
alignment studs that fit into the drain
body
Step 3: Position the drain with
the silicone gasket under the
center of the cover.
Step 4: With the center punch,
find one of the 10 holes in the
drain body and puncture only
one hole through the cover.
Step 5: Position the rigid ring and
fiber gasket over the cover, aligning
the holes in the drain. Do not
completely tighten the screw down at
this time. This will allow the rigid ring
to pivot and line up with the other
screws.
Step 6: Align the rigid ring and
fiber gasket with the body of the
drain. Make sure that the cover
lays flat on the drain body and
gasket. Locate the screw hole on
the opposite side of the first
screw and puncture the cover for
the next screw.
Step 7: Insert the second screw.
Do not completely tighten the
screw this time.
Step 8: Keeping the cover pulled tight
over the drain, punch the remaining
holes. Insert the remaining screws.
Step 9: Once all the screws are
installed, tighten them down.

Step 10: Using a utility knife,
carefully cut the cover from
inside the reservoir and discard.
Step 11: Take the drain guard and
install it on the reservoir with the two
long stainless screws. Tighten the
screws down and then back them out a
half turn. This will allow room for
expansion in freezing conditions.
Step 12: Fold the cover back to
expose the bottom of the drain.
Take the 1” flexible pipe and
screw the end with the male
adapter into the threaded port in
the reservoir. Do not cross
thread. Teflon tape has been
installed on the threads to seal
the connection. If the hose is
removed at anytime from the
reservoir, the tape must be
reapplied.
Step 13: Do not over tighten this
connection. Make sure that the
pipe is heading down toward the
bottom of the drain like shown.

Warranty Information
R& R of Mid-America, LLC takes great pride in the quality products we sell. The company maintains high standards
for the material and workmanship invested in its products. R&R of Mid-America, LLC warrants its product as follows:
R&R of Mid-America, LLC warrants its product to be free of defects in material and workmanship. Should any part of
the drain kit body become defective within one year from the date of original purchase.
This warranty extends to the party making the original purchase of the products from R&R of Mid-America, LLC and
is not enforceable by any other party. The forgoing warranty does not apply to components manufactured by others;
for such products, the warranty established by the respective manufacturer, if any, will apply.
R&R of Mid-America, LLC will not be liable for shipping of the warrantee item to or from R&R of Mid America,
LLC. This product does not protect pools or covers against freezing. Any damage caused by freezing will not be
covered by the warranty. It is the responsibility of the end user to protect the pool and cover from freezing.
This warranty does not cover failure in service due to improper installation, improper operation, improper
environment, negligence, accidents, wreckage, freezing, improper repacking or damage incurred during shipping.
R&R of Mid-America, LLC shall not be liable for any injury, loss or damage, direct or consequential arising from the
use of its products.
This warranty gives you specific legal rights. You may also have other rights, which vary from state to state.
For communication related to replacement products or other warranty issues, pleas contact:
R&R of Mid-America, LLC
2805 Grover Hall Road – Wingo, Kentucky 42088
Phone: 270 – 376 – 3284 Fax: 270 – 376 – 3285

Dryco Pool Cover
Drain Kit
Important
When connecting drain hose to inlet in step 3 of the installation instructions for pool cover, it is
extremely important that the hose does not have any loops or kinks in it as shown below in
figure 1.
You must loosen the union, and twist the pipe to work the loops and kinks out. While the union
is loose let the water fill the pipe. This will allow the pipe to sink towards the bottom of the
pool. When finished the pipe should hang straight as shown in figure 2.
Be sure to tighten the union completely when done.
Failure to do this will result in a leak and pool water will drain out of the pool.
Figure 1 – Wrong Figure 2 - Right

Installation Instructions for Pool Cover with Dryco
Drain on Above Ground Pools
STEP 1:
Remove the eyeball diverter from the inlet water return
STEP 2:
Separate the union that is attached to the hose and screw
it in the bulkhead. An adapter will be needed for the
bulkhead fittings other than the 1-1/2” female threads.
Assure that the o-ring is installed on the union as shown.
Tighten until o-ring is seated and sealed.
STEP 3:
Before stretching the cover over the pool, connect the
hose with the union to pool inlet. Make sure the o-ring
seal remains seated in the union. Union must have a
watertight seal to prevent loss of any pool water.
Install the cover as normal. Make sure that the drain hose is aligned with the outlet. Twisting the cover may be
required to assure proper alignment.
The hose should drop down toward the bottom of the pool. If the flexible pipe has twisted while being installed, loosen
the union to adjust. The union must be tightened completely to assure a proper seal.
Table of contents
Popular Lighting Equipment manuals by other brands

Feit Electric
Feit Electric OneSync UCL24/5CCT Important Safety Instructions and Installation Guide

Beamz Pro
Beamz Pro 150.164 V1.0 user manual

Bardic
Bardic Fast LG1LF Installation - Maintenance Testing Instructions and Warranty

Light Sky
Light Sky TourPro s500 Hybrid user manual

Blizzard Lighting
Blizzard Lighting Switch Blade X3 Manuals

PLG
PLG APOLLO DEEP user manual