OPERATION
1. Make BGM signalinputfrom Aterminalwhile EMC signalinputfrom Bterminalontherearpanel.
Wealsocanmake A, B togetherwithshortcircuit ifthereisnoneof BGM amplifier.
2. Press downany Distributorkey toswitchonchannelswhichyouwant.
3. Click All call button withitsLEDlit and all Switchindicators lit. Inthiscase, all Switchingkeys
areno use. Click All call button againanditsLEDgoneoff, Inthiscase, all Switching keys areuse.
4. Pin1-10 of ALARMIN”portare live terminalsof CH1-CH10 respectivelywhilepin14-25 are
com. Everychannelwill beswitchto Bwhilealarmsignal(shortcircuit signal)isfedto ALARMIN.
5. Angrounded Alarm signalwillbesendoutfrom ALARMOUT”whileanyalarmsignal
appearson“ALARMIN”.
SPECIFICATIONS
Channels 10, switchable
Inputcapacity 70-100V ,10A
Channelcapacity 70-100V ,5A/CH
ALM0/+24V, 0 shortcircuit)isValid
Protection ACfuse
PowerRequirement AC220-240V/50-60Hz
OuterPacking Size(mm) L×W×H)530×440×195
Unit Size(mm) L×W×H)484×365×88
Gross weight 8.3kg
Netweight 6.5kg
Specificationsaresubjecttobechangedwithoutnotice.
CAUTION
●Whenthe Powerswitcher”isoff, pleasepull outthepowercordfromthesocket.
Pleasekeeptheequipmentoutofwater.
●Toreduce theriskofelectricshock, donotremovethecover.
●Nouserpartsinside. Referservicing toqualifiedservice personnel.
GuangzhouDSPPAAudio Co., Ltd.