Product handleiding
RUKRA GSM/PSTN Interface_NL_V1.2
Artikelnummer: RK-1240
KENMERKEN:
230 VAC / 12VDC powersupply with integreted backup battery
Call by VoLTE possible
3G / 2G fallback
Phone line for up to 5 RUKRA Elevator Phones or other brands elevator phones
Automatic control of the capacity of the backup battery
Roaming can be switched off (Roaming is communication between different networks abroad)
Send SMS on the status of the power supply and battery status (power, voltage, capacity and battery defect)
INTERNAL CONNECIONS
1. Antenne aansluiting
2. Simkaart slot
3. Connection battery 7,2 V / 800 Mah
4. Connection power supply 12Vdc
5. Connection phone line RJ-11 connector
6. Indication Led‘s
Installation:
Only use the supplied 230VAC/12VDC power adapter and the supplied 2-wire telephone cord.
Use the supplied magnets or screws to fix the GSM module (see image page 3 for placement of magnets).
The RUKRA 4G GSM/PSTN interface is preferably placed in the machine room, but can also be mounted in the elevator shaft or on
the roof of the elevator cabin. Always connect the 230VAC adapter to a fixed voltage (never to the cabin lighting), always check
whether the RUKRA 4G GSM/PSTN interface only works on the power supply from the battery and on the 12VDC power adapter.
Always install the GSM/PSTN interface and the antenna as far away from the RUKRA Liftphone as possible.
SIM card
Make sure that the SIM card pin code is free! Insert the SIM card into a regular mobile phone. Turn it on and check whether it asks
for a PIN code. If you are asked for a PIN code, go to the menu “Security settings” and set the option “PIN code request” to “OFF”.
Before inserting or replacing the SIM card, always ensure that the GSM is disconnected from the power supply and battery. As soon
as the voltage is reconnected, the unit will search for the network again, as soon as the green and red LED start flashing, the unit is
connected to the network again.
Note! When inserting a SIM card, make sure that it is placed with the edge side facing the antenna connection, and then close the
slide.