The system adopts wireless digital coding, high-frequency emission and receiving, and the repetitive code rate is
very little, it adopts MCU control and on technology adopts SMT , it can connect all kinds of detectors our company
produce, for example PIR detector, door magnetism, smoke alarm, out-connected alarm, out-connected dial number
equipment, at the same time it gather wireless doorbell, tamper protection, low-voltage indicate. It has two remote
controllers, its operation is very convenient, it can guard your family from multi-orientation.
SPECIFICATION
1 voltage(power adapter convert):110VAC 230VAC
2 standby power:9V/DC(6×AA)
3 operate frequency: 433MHz 315 MHz
4 operate channel:6(wireless channel has 6, 2 of 6 are also wire channels)
5 alarm method:sound and light alarm indicator
6 alarm current:150mA
7 out power static current: 26 mA
8 standby power static current:16 mA(when out power cut)
9 alarm time:3Min 30seconds
10 alarm sonority:90db
11 remote control distance: ≥30m( wide place)
12 battery low-voltage alarm:7.5V~7.9V
13 the system include unit: general controller(with power adapter)、single doorbell remote controller(battery
included) 、4-key remote controller(battery included) 、power adapter(input voltage 110VAC/230VAC, output voltage
10~12V/DC, current 1A) 、DPS-55 PIR detector(battery included)、door
magnetism(battery included). The unit for choosen: other type detector、
smoke alarm with RF、dial number equipment etc.
14 working LEDs:
Ch1~Ch4: red, wireless detector channel LED;
Ch5~Ch6: red, both wireless and wire detector channel LED;
Fortify: green, fortify LED;
Low-battery: green, battery low-voltage LED;
Power LED&Panic key: green, out power LED. when out power is
connected, it lights. At the same time, the key is panic key, press
the key, the general controller give panic alarm.
SUMMARY
1. channel indicate: when detector working, general controller
alarm and corresponding channel LED should light.
2. low-voltage indicate: when standby power is below set value, cut off out power, you can see Low-battery LED
flashing and remind you to replace battery in time.
3. tamper protection: when front cover is opened, general controller will give alarm, the 8 LEDs on the left and
right all flash.
4. two remote controllers:
zsingle-key doorbell remote controller: power voltage DC12V, it can be installed out of the door and
used as remote control doorbell;
z4-key remote controller: power voltage DC12V, it is used for panic alarm, time-delay fortify, quick fortify,
cancel.
5. fortify: when host leave home, use remote controller to set general controller on fortify state, when someone
enter its detection field, general controller will give alarm (>90db), if connect dial number implement of our company,
general controller will also give alarm weft, for example 110 or your home’s telephone.
6. cancel: after host come back home and cancel the general controller’s fortify state, when host enter detection
field, the general controller will not alarm.
Ch6
Ch5
Low-battery
Fortify
Power LED&Panic key
Ch4
Ch3
Ch1
Ch2
GENERAL CONTROLLER

+
12V/OUT
_CN5 CN6
-
LED-POW
LED--6
LED
LED--5
PANIC ALARM SWTICH
PCB
LED
LED--6
LED
PT2272-M4
LED--POW
LED--5
DIP
8
7654
ON
LED--4
321
PIC16C57C
MICROCHIP
LED
LED--3
LED--2
LED--1
DIP SWTICH
LED--4
LED--1
LED--3
LED--2
TAMPER SWITCH
BATTERY CONTAINER
+-
RT0302
ALARM/OUT
GND
-+
SONLE
SRS-12VDC-SL
+
_
12V/IN
+
RELAY
CN5 CN6
_12V/OUT
+
RELAY
ALARM/OUT +
12V/IN
_
BUZZER
CONNECTION COLUMN
BOTTOM COVER
123 456 78910 11 12
_+
7. panic alarm: when danger occur in your home, you can prees the panic key to give panic asking for help
signal to neighbor or others and obtain other’s help.
8. alarm memory: on fortify state, when host isn’t at home there is person enter detection field, general controller
alarm, after the alarm stops, the corresponding LED still light to indicate that channel ever had danger, only after
using remote controller to reset, the LED will be off.
GENERAL CONTROLLER
1.Connection-wire figure:
1.1. terminal 1&2: output voltage, connect 1
with “-“,connect 2 with “+“;
1.2. terminal 3&4 can connect with wire
detector, is 5th channel CN5,
corresponding indicator is Ch5;
1.3. terminal 5&6 can connect with wire
detector, is 6th channel CN6,
corresponding indicator is Ch6;
1.4. terminal 7&8: alarm output, when it alarm,
other alarm connected with it also
alarm,7connect with “-“, 8 with “+”;
1.5. terminal 9&10: other output;
1.6. terminal 11&12 input voltage , connect 11
with “-“, connect 12 with “+“.
2.operation
2.1 install detector on selected position;
2.2 connect wire according to connection-wire
figure: connect “-” and “+” of power adapter to
terminal 11&12, and the polarity can not be
connected oppositely, connect CN5 and CN6 with
wire detector, they are two wire channels, the
correspondinng indicator separately is Ch5 and Ch6, NOTE: if CN5 or CN6 is not connected, general controller
will alarm and corresponding channel LED (Ch5 or Ch6) will light, so when no wire detector connected, CN5
and CN6 shoud be short connected avoiding unwanted alarm;
2.3 install 6 AAbatteries into battery container according to right polarity;
2.4 plug power adapter into power socket, power LED should light, Fortify and Low-battery LEDs flash once 0.5
second, after 60s, general controller give one DI sound, Fortify LED flashes once 2s and Low-batter4y LED stop
flashing and remain on. NOTE: during this 60s, any operation is not effect.
2.5 close front cover. NOTE: after power is on, there is 60s to wait you close front cover avoiding tamper
alarm.
2.6 press the panic key on general controller, it give panic alarm and all LEDs light, the alarm time is 3Min 30s(press
the cancel key on 4-key remote controller to stop alarming quickly);
2.7 press fortify key on 4-key remote controller, set general controller on fortify state;
2.8 test every detector one by one, when wire detector work, general controller alarm, the alarm time is 3Min 30s,
the corresponding channel LED(Ch5 or Ch6)should light. When wireless detector work, general controller
should alarm, alarm time is 3Min 30s, corresponding channel LED(Ch1 or Ch2,3,4,5,6)should light.
3. attention:
avoid installing the unit on metal base;
when general controller alarming, the sound is very high, so when alarm occur, you should eliminate it in
time avoiding affecting others.
if power adapter need replacing, the replacing adapter’s standard should be: input voltage
110VAC/230VAC, output voltage 10~12V/DC, current 1A. suggest you contacts with supplier and use original
adapter.
if the power adapter is connected oppositely, the unit will not work, but it will not be damaged;

the connection line between wire detector and general controller should not exceed 3m, and should
install detector out of the way.
DOORBELL REMOTE
CONTROLLER
1. operation: install it out of the door and use it as remote control doorbell, press the key,
general controller will give Dingdong Dingdong to remind host open door. It can not
operate other function of the general controller.
2
.
Attention: avoid installing the unit on metal base.
4-KEY REMOTE CONTROLLER
1.operation
1.1 press the panic alarm key, general controller will give panic alarm and the 8 LEDs on
the left and light all light.
1.2 press time-delay fortify key, general controller will give DI…
DI……, Fortify LED flash once a second, after 60s, it give DI DI DI
then sound stop, it enter fortify state, Fortify LED flash once 2s.
1.3 press quick fortify key, general controller give DI and it enter
fortify state, Fortify LED flash once 2s.
1.4 press cancel key, you can cancel above operation, general
controller give DI DI, that indicate operation has been canceled.
2
.
Attention: avoid installing the unit on metal base.
WIRELESS DETECTOR DPS-55
1.Jumper setting (like right
figure)
1.1 Sense once to emit:
sense once, the sensor emit
signal , 15S later after it emit
signal, sense once again, the
sensor emit signal again.
1.2 Sense twice to emit:
sense twice, the sensor emit signal , 15S later after it emit signal,
sense twice again, the sensor emit signal again. This setting
enhance its preventing false-alarm and preventing-pet
function.
2. test
2.1 press the fortify key on 4-key remote controller, set the general controller on fortify state.
2.2 set the jumper on needed position;
2.3 install 9V battery, after 60s the sensor enter stable working state;
2.4 move along the tangent of the lens, sense it, the sense LED light and then it emit signal to general controller, the
emission LED light;
2.5 after receiving emission signal, general controller give alarm(>90db), the alarm time delay is 3Min 30s, provided
that its corresponding channel is channel 3, the Ch3 should light(press cancel key on 4-key remote controller to stop
alarm quickly).
EMISSION
LED
BATTERY
COVER
PANIC ALARM
TIME-DELAY FORTIFY
QUICK FORTIFY
CANCEL
4-KEY REMOTE CONTROLLER
EMISSION LED
EMISSION KEY
DOORBELL REMOTE CONTROLLER
BOTTOM COVER
INSTALLING HOLE
INSTALLING HOLE
CROSSING-LINE
HIDDEN HOLE
INSTALLING HOLE
INSTALLING HOLE
CROSSING-LINE
HIDDEN HOLE
PRESS HIDDEN HOLE WITH POWER TO OPEN
BOTTOM COVER FIGURE(BACK)
2
3
OPEN FRONT COVER FIGURE
FRONT COVER
TIGHTEN OFF
SCREW
1
PUSH BACK THE
FRONT FCOVER
PULL UP THE
FRONT COVER
AUTO
DIP switch Sense LED
PIR
Jumper
AUTO / 1 AUTO / 1
1
Emit LED
Sense
once to
emit
Sense
twice to
emit
Low-battery LED

3. Attention:
3.1 Low-battery indicate: when the battery energy is below 7V, the low-battery LED in crystal board will flash
once a second and you should replace the battery;
3.2 Avoid installing the unit on metal base;
3.3 Avoid installing the unit where sun shine or temperature change obviously, for example: air conditioning,
heater etc.
DOOR MAGNETISM
1. install magnetism and emitter on upright position of door lock, the
distance between them is 3mm~5mm and triangle on emitter aim at
triangle on magnetism(like right figure);
2. install DC12V battery into emitter;
3. press fortify key on 4-key remote controller, set general controller on
fortify state;
4. Open door, the emitter is triggered and its LED light, then emit signal
to general controller, the general controller alarm, provided that its
corresponding channel is channel 5, the Ch5 should light.
5. Tamper design: Under the condition that the triangle on emitter aim at triangle on magnetism, when emitter’s
battery lid is removed, it will emit signal and its LED light.
6. Attention: the magnetism should be on the left of the emitter(like following figure).
THE SYSTEM CONFIGURATION
Basic
configuration
General controller*1 doorbell remote controller*1 4-key remote controller*1 DPS-55 PIR detector*1 door magnetism*1
The units for your
choosing at will
Wire detector:
DOOR
DOOR FRAME
DOOR LOCK
695
PIR detector
TK-5
glass-break detector DD
T
-15 glass-break&
PIR detector double detecto
r
Incorrect position
Correct position

wireless detector:
wire or wireless detector:
DSW-98
A
Smoke detector Smoke detecto
r
TK-9
PIR detector
Table of contents
Other DSW Security System manuals
Popular Security System manuals by other brands

Pima
Pima Hunter-Pro 832 user guide

Ecco
Ecco 7965 Series Installation and operation instructions

Heathkit
Heathkit Heathkit GD-1183 Operation manual

Quell
Quell Q7DCO User and installer guide

Whelen Engineering Company
Whelen Engineering Company B6LED Series installation guide

Bosch
Bosch LTC 8850 Series instruction manual