DTS FOS 100 POWER FC User manual

2
Le informazioni contenute in questo documento sono state attentamente redatte e
controllate. Tuttavia non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i
diritti sono riservati e questo documento non può essere copiato, fotocopiato, riprodotto
per intero o in parte senza previo consenso scritto della D.T.S .
D.T.S. si riserva il diritto di apportare senza preavviso cambiamenti e modifiche
estetiche, funzionali o di design a ciascun proprio prodotto. D.T.S non assume alcuna
responsabilità sull’uso o sull’applicazione dei prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked.
However, no responsibility will be taken for any errors. All rights are reserved and this
document cannot be copied, photocopied or reproduced, in part or completely, without
prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any
of its products without prior notice. D.T.S. assumes no responsibility for the use or
application of the products or circuits described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec
le plus grand soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles
inexactitudes. Tous droits réservés. Ce document ne peut être copié, photocopié ou
reproduit, dans sa totalité ou partiellement, sans le consentement préalable de D.T.S.
D.T.S. se réserve le droit d'apporter toutes modifications et améliorations esthétiques,
fonctionnelles ou de design, sans préavis, à chacun de ses produits. D.T.S. décline toute
responsabilité sur l'utilisation ou sur l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamente redactadas
y controladas. Con todo, no se asume ninguna responsabilidad por eventuales
inexactitudes. Todos los derechos han sido reservados y este documento no puede ser
copiado, fotocopiado o reproducido, total o parcialmente, sin previa autorización escrita
de D.T.S.
D.T.S. se reserva el derecho a aportar sin previo aviso cambios y modificaciones de
carácter estético, funcional o de diseño a cada producto suyo. D.T.S. no se asume
responsabilidad de ningún tipo sobre la utilización o sobre la aplicación de los productos
o de los circuitos descritos.

3
INDEX:
1- SYMBOLS.............................................................................................................. 4
2- GENERAL WARNING............................................................................................ 5
3- GENERAL WARRANTY CONDITIONS................................................................. 5
4- TECHNICAL FEATURES....................................................................................... 6
5- ACCESSORIES ................................................................................................... 10
6- IMPORTANT SAFETY INFORMATION............................................................... 11
6.1 Fire prevention....................................................................................................11
6.2 Prevention of electric shock................................................................................ 11
6.3 Safety.................................................................................................................. 11
6.4 Level of protection against the penetration of solid and liquid objects ................ 11
6.5 Waste Electrical and Electronic Equipment (WEEE) directive............................ 11
7- INSTALLATION ................................................................................................... 12
7.1 Floor mounting installation.................................................................................. 12
7.2 Ceiling mounting installation............................................................................... 12
8- INPUT / OUTPUT CONNECTIONS...................................................................... 13
9- DMX SIGNAL CONNECTION.............................................................................. 16
9.1 DMX Addresses..................................................................................................17
9.2 Selecting the DMX address ................................................................................ 17
10- RDM FUNCTIONS.............................................................................................. 18
11- FIRMWARE UPDATING .................................................................................... 20
12- DISPLAY FUNCTIONS ...................................................................................... 21
13- REC MODE.........................................................................................................24
14- UV PROTECTION SCREEN INSTALLATION ................................................... 24
15- DMX PROTOCOL............................................................................................... 25

4
1- SYMBOLS
Graphic symbols used on this manual:
THIS SYMBOL INDICATES A HOT SURFACE
THIS SYMBOL INDICATES ELECTRIC SHOCK RISK
THIS SYMBOL INDICATES GENERAL RISK
THIS SYMBOL INDICATES THE MAXIMUM
OPERATING AMBIENT TEMPERATURE
THIS SYMBOL MEANS “DO NOT STARE
AT THE OPERATING LIGHT SOURCE”
THIS SYMBOL INDICATES
PHOTOBIOLOGICAL SAFETY
THIS SYMBOL INDICATES THE MINIMUM
DISTANCE BETWEEN THE UNIT AND THE
ILLUMINATED OBJECT
THIS SYMBOL INDICATES THE EUROPEAN
COMMUNITY DIRECTIVE 2012/19/EC ON
WASTE ELECTRICAL AND ELECTRONIC
EQUIPMENT (WEEE)
!

5
2- GENERAL WARNING
Read the instruction contained in this user manual carefully, as they give important
information regarding safety during installation, use and maintenance.
The unit is not for household use and must be installed by a qualified electrician or
experienced person.
Always secure fixture with safety wire before suspending.
Always use two clamps to mount the fixture.
Do not open the unit. Always disconnect the projector from the mains before
maintenance.
The level of technology inherent in the unit requires the assistance of specialised
personnel for all servicing. Please refer to an authorised D.T.S. service centre.
No user serviceable parts inside.
In case lenses sets replacement is needed, frontal gasket must be replaced so as to
maintain IP 65 rate protection. LEDs are not replaceable.
The device must always be equipped with an efficient ground connection.
3- GENERAL WARRANTY CONDITIONS
The unit is guaranteed for 36 months from the date of purchase against manufacturing
material defects.
The warranty covers defects in materials and workmanship. The warranty is not appliable
where a defect is caused by misuse or unauthorised repair of the product.
Any functional or/and physical modification of the product is not allowed.

6
4- TECHNICAL FEATURES
FOS 100 POWER SOLO FC
Output
24 Full Color (RGBW) LEDs
8.864 Lumens
LEDs lifespan: 50.000 hours (70% lumen output)
Optical group
3 lenses sets available: Narrow, Medium, Wide
Holographic filters available on request
Color generation
16 million colors
Wide palette of pure uniform whites
Variable linear color temperature 2700K –8000K
Control
Multi-function 4-digit 7-segment LED Display + 4 soft keys
RDM / DMX 512 protocols
Internal operating system updatable via DTS Dongle Firmware Uploader
DMX
10 DMX channels (default)
Power supply
Integrated IP20 or IP65 PSU: full-range 100-240Vac 50-60 Hz
Power consumption: 200W max
Power Factor: PF > 0.95
Connections
IP20-rated PSU:
PowerCON IN/OUT panel connectors
XLR 5-pole IN/OUT panel connectors
IP65-rated PSU:
Power IN cable; Power OUT Harting panel connector
DMX IN/OUT cables with XLR 5-pole IP20 connectors
Operating temperature
-20° / 40°C
Physical
IP20 or IP65
Housing: Aluminium
Weight (IP20-rated): 7.3 Kg
Weight (IP65-rated): 7.9 Kg
Finishing: Black
Certifications

7
DIMENSIONS
FOS 100 POWER SOLO FC

8
4- TECHNICAL FEATURES
FOS 100 POWER FC
Output
24 Full Color (RGBW) LEDs
8.864 Lumens
LEDs lifespan: 50.000 hours (70% lumen output)
Optical group
3 lenses sets available: Narrow, Medium, Wide
Holographic filters available on request
Color generation
16 million colors
Wide palette of pure uniform whites
Variable linear color temperature 2700K –8000K
Power supply
External PSU:
DRIVENET 416 POWER (full-range 100-240Vac 50-60 Hz)
DRIVENET 832 POWER (range 180-240Vac 50-60 Hz)
Max out current: 1600mA
Power consumption: 200W
Connections
30 cm cable with M16 male connector
Operating temperature
-10° / 40°C
Physical
IP65
Housing: Aluminium
Weight: 5 Kg
Finishing: Black
Certifications

9
DIMENSIONS
FOS 100 POWER FC

10
5- ACCESSORIES
As standard (IP20-rated PSU)
1 x PowerCON IN female cable connector (code 0520P014)
1 x PowerCON OUT female cable connector (code 0520P029)
1 x XLR 5-pole male cable connector (code 0508B028)
1
x XLR 5-pole female cable connector (code 0508B027)
1 x Fit joint for joining bars inline (code 02M09519.46)
2
x M4 knob for fit joint (code 0511P014)
1 x User’s Manual
As standard (IP65-rated PSU)
1
x HARTING 5-pole female cable connector (code 02LD0033)
1 x Fit joint for joining bars inline (code 02M09519.46)
2
x M4 knob for fit joint (code 0511P014)
1 x User’s Manual
Optional (on request)
-
Flightcase for 4 units (code 0521C069)
-
UV protection screen (code 0511C283)
-
Lenses set Narrow (code 03.LK.107.N)
-
Lenses set Medium (code 03.LK.108.N)
-
Lenses set Wide (code 03.LK.109.N)
-
Barndoor and Holographic filter holder (code 03.LA.142)
-
Short bracket for wall installation (code 03.LA.025)
-
Outdoor DMX cable 2x0,25 sq mm –flame retardant (code 0509C158)
-
Permanent Installation Kit IP68 (only for IP65-rated PSU) (code 03.LA.216)
-
G60 ‘’C’’ Clamp – max. load 50 Kg (code 0521A004)
-
Safety cable 3 mm x 60 cm, max capacity load 60 Kg (code 0521A010)
-
DTS Dongle Firmware Uploader (code 03.LA.206)

11
6-IMPORTANT SAFETY INFORMATION
6.1 Fire prevention:
-Minimum distance from the closest illuminable surface: 0,5 m.
-Minimum distance of flammable materials from the surface 0.5 m.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
6.2 Prevention from electric shock:
-High voltage is present inside the unit.
-Unplug the unit prior to performing any operation which involves touching the inside of the unit.
Use only AC supplies 100-240V 50-60 Hz.
-The level of technology inherent in the FOS 100 POWER SOLO FC requires the assistance of
specialised personnel for all servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
6.3 Safety:
-Risk Group 2 product according to IEC 62471.
CAUTION. Do not look directly into the light output and do not view the light beam with optical
instruments or any device that may concentrate the beam.
May be harmful to the eyes and skin.
-Do not stare at the operating light source.
-The luminaire should be positioned so that prolonged staring into the luminaire at a distance of
9,11 m is not expected.
-The light source contained in this luminaire shall only be replaced by the manufacturer or his
service agent or a similar qualified person.
-The light source must be replaced if damaged or deformed by heat.
-Glass frontal protection screen must be mounted and, if visibly damaged, it must be replaced.
-The unit is not for household use and must be installed by a qualified electrician or experienced
person.
-The projector should always be installed with bolts, clamps and other tools that are capable of
supporting the weight of the unit.
-Always use a safety cable to sustain the weight of the unit in case of the failure of the main fixing
point.
-The external surface of the unit, at various points, may exceed 50°C.
Never handle the unit until at least 5 minutes have elapsed since the unit was turned off.
-Never install the fixture in an enclosed area lacking sufficient air flow.
The ambient temperature should not exceed 40°C.
6.4 Level of protection against the penetration of solid and liquid objects:
IP20-rated PSU: The unit is classified as an ordinary appliance and its protection level against the
penetration of solid and liquid objects is IP20. Suitable for dry locations only.
IP65-rated PSU: The unit is classified as an outdoor appliance and its protection level against the
penetration of solid and liquid objects is IP65. Suitable for wet locations.
6.5 Waste Electrical and Electronic Equipment (WEEE) directive:
The projector, accessories and packaging should be sorted for environmental-friendly recycling.
For EC countries: according to the European Directive 2012/19/EU for Waste Electrical and
Electronic Equipment and its implementation into national right, luminaires that are no longer
usable must be collected separately and disposed of in an environmentally correct manner.
!
!

12
7- INSTALLATION
FOS 100 POWER and FOS 100 POWER SOLO IP65 are suitable for wet locations.
FOS 100 POWER SOLO IP20 is suitable for dry locations only.
The unit may be either floor or ceiling mounted.
7.1 Floor mounting installation
For floor mounting installation, FOS 100 POWER is supplied with rubber mounting feet on
its brackets.
7.2 Ceiling mounting installation
For ceiling mounting installation, it is recommended the use of appropriate clamps to fix the
unit to the mounting surface.
The supporting structure from which the unit is hung should be capable of bearing the
weight of the unit, as should any clamps used to hung it.
Fixing clamps for truss are available on demand.
ATTENTION: two safety cables must be securely fixed to the unit and to the support
structure of the projector as shown in the picture.
A suitable safety cable (code 0521A010) is available on demand.

13
8- INPUT / OUTPUT CONNECTIONS
FOS 100 POWER SOLO IP20
MAINS IN
100-240Vac 50-60 Hz
PowerCON male panel connector
MAINS OUT
MAX 16A
PowerCON female panel connector
LED IN
Cable with M16
Male connector
LED OUT
Cable with M16
Female connector
DMX IN
XLR 5 poles male
panel connector
DMX OUT
XLR 5 poles female
panel connector
GORE
Valve

14
8- INPUT / OUTPUT CONNECTIONS
FOS 100 POWER SOLO IP65
3 poles terminal block or plug not included. Installation may require advice from a qualified person.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced
by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
DMX IN
Cable with XLR 5 poles male
IP20 connector (0.8 m length)
LED OUT
Cable with M16
female connector
LED IN
Cable with M16
male connector
MAINS IN
100-240Vac 50-60 Hz
3x1,5 sq mm power cord (1,5 m)
DMX OUT
Cable with XLR 5 poles female
IP20 connector (0.8 m length)
MAINS OUT
MAX 10A
HARTING female
panel connector
GORE
Valve
!
!
!

15
8- INPUT / OUTPUT CONNECTIONS
FOS 100 POWER (IP65)
LED IN
30 cm cable with M16 male connector

16
9- DMX SIGNAL CONNECTION
FOS 100 POWER SOLO IP20
FOS 100 POWER SOLO IP65
The unit operates using a digital DMX 512 signal.
Connection between the controller and the unit or between units must be carried out using a
two pair screened ø 0.5 mm.
Ensure that the conductors do not touch each other.
Do not connect the cable ground to the DMX connector chassis.
The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug
and connect it to the next projector by connecting the DMX OUT plug on the first unit to the
DMX IN plug of the second one.
In this way, all the projectors are cascade connected.
CONTROLLER
S TA N D A R D
D M X 5 1 2
UNIT 1 UNIT 2 UNIT 3
If the display showing the DMX address flashes, then one of the following errors has
occurred:
-
DMX signal not present
-
DMX reception problem
For Installations where long distance DMX cable connections are needed, we suggest to
use a DMX terminator.
The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor Between
pin 2 and 3.
The DMX terminator must be plugged into the last unit (DMX out panel connector) of the
DMX line.
5 1
4 2
3
OUT
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
PIN 3
120 ohm
PIN 2
3
2 3=DATA+
4
1=GND
2=DATA-
1
5

17
9.1 DMX addresses
FOS 100 POWER SOLO can be used in 10 DMX modes:
1. RGBW 6 channels
2. RGBW 10 channels (Default)
3. RGBW 15 channels 16 bit
4. WALL 6 channels
5. M4CH 5 channels
6. RGBW 4 channels
7. 1 channel
8. RGBW 10 channels 16 bit
9. DW 2 channels
10. PROM 11 channels
If you want to use the FOS 100 POWER SOLO in 10 DMX channels mode (Default), set
the following addresses on the mixer:
Projector 1 A001
Projector 2 A011 If you want to select the next projector, just add “10”
Projector 3 A021
….. A….
projector 6 A051
9.2 Selecting the DMX address
1)
Press the UP-DOWN key until you reach the required DMX address. The
numbers on the display will start to flash (but the new DMX address hasn't yet
been set).
2)
Press ENTER to confirm your selection. The numbers on the display will stop
flashing and the projector is now controlled by the new DMX address.
TIPS: if you keep pushed the UP or DOWN keys, the channels are calculated
more quickly and you get a faster selection.

18
10- RDM FUNCTIONS
By using a RDM controller it is possible to set DMX address, DMX mode and other
parameters. FOS 100 POWER SOLO accepts the following RDM commands:
RDM Device Model ID: 0x0D06
RDM PID DESCRIPTION
RDM PID VALUE
GET
SET
Category –Network Management
DISC_UNIQUE_BRANCH
0x0001
DISC_MUTE
0x0002
DISC_UN_MUTE
0x0003
Category - RDM Information
SUPPORTED_PARAMETERS
0x0050
X
PARAMETERS_DESCRIPTION
0x0051
X
Category –Product Information
DEVICE_INFO
0x0060
X
DEVICE_MODEL_DESCRIPTION
0x0080
X
MANUFACTURER_LABEL
0x0081
X
DEVICE_LABEL
0x0082
X
X
SOFTWARE_VERSION_LABEL
0x00C0
X
Category - DMX512 Setup
DMX_PERSONALITY
0x00E0
X
X
DMX_PERSONALITY_DESCRIPTION
0x00E1
X
DMX_START_ADDRESS
0x00F0
X
X
Category –Sensors
SENSOR_DEFINITION
0x0200
X
SENSOR_VALUE
0x0201
X
X
Category –Display Settings
DISPLAY_INVERT
0x0500
X
X
Category –Control
IDENTIFY_DEVICE
0x1000
X

19
10- RDM FUNCTIONS
RDM PID DESCRIPTION
RDM PID VALUE
GET
SET
Category –Manufacturer-Specific PIDs
DISPLAY STANDBY
0x903C
X
X
EMERGENCY MODE
0x9008
X
X
NO DMX ACTION
0x9002
X
X
RED NO DMX
0x9003
X
X
GREEN NO DMX
0x9004
X
X
BLUE NO DMX
0x9005
X
X
WHITE NO DMX
0x9006
X
X
INT NO DMX
0x900A
X
X
RED FINE NO DMX
0x9014
X
X
GREEN FINE NO DMX
0x9015
X
X
BLUE FINE NO DMX
0x9016
X
X
WHITE FINE NO DMX
0x9017
X
X
INT FINE NO DMX
0x9018
X
X
RED2 NO DMX
0x9019
X
X
GREEN2 NO DMX
0x901A
X
X
BLUE2 NO DMX
0x901B
X
X
WHITE2 NO DMX
0x901C
X
X
INT2 NO DMX
0x901D
X
X
RED2 FINE NO DMX
0x901E
X
X
GREEN2 FINE NO DMX
0x901F
X
X
BLUE2 FINE NO DMX
0x9020
X
X
WHITE2 FINE NO DMX
0x9021
X
X
INT2 FINE NO DMX
0x9022
X
X
RED3 NO DMX
0x9023
X
X
GREEN3 NO DMX
0x9024
X
X
BLUE3 NO DMX
0x9025
X
X
WHITE3 NO DMX
0x9026
X
X
INT3 NO DMX
0x9027
X
X
RED3 FINE NO DMX
0x9028
X
X
GREEN3 FINE NO DMX
0x9029
X
X
BLUE3 FINE NO DMX
0x902A
X
X
WHITE3 FINE NO DMX
0x902B
X
X
INT3 FINE NO DMX
0x902C
X
X
RED4 NO DMX
0x902D
X
X
GREEN4 NO DMX
0x902E
X
X
BLUE4 NO DMX
0x902F
X
X
WHITE4 NO DMX
0x9030
X
X
INT4 NO DMX
0x9031
X
X
RED4 FINE NO DMX
0x9032
X
X
GREEN4 FINE NO DMX
0x9033
X
X
BLUE4 FINE NO DMX
0x9034
X
X
WHITE4 FINE NO DMX
0x9035
X
X
INT4 FINE NO DMX
0x9036
X
X

20
10- RDM FUNCTIONS
RDM ADDITIONAL MESSAGEs:
ADDITIONAL MESSAGEs
DESCRIPTION
DISPLAY INVERT
0 = DISABLED (Default)
1 = ENABLED
RDM MANUFACTURER-SPECIFIC PIDs:
MANUFACTURER-SPECIFIC PID
DESCRIPTION
DISPLAY STANDBY
0 = DISABLED (Default)
1 = ENABLED
EMERGENCY MODE
0 = DISABLED (Default)
1 = ENABLED
NO DMX ACTION
1 = BLACK-OUT
2 = RGB 60%
3 = RGB 100%
4 = CUSTOM
5 = KEEP LAST (default)
6 = CUSTOM2
7 = CUSTOM3
8 = CUSTOM4
11- FIRMWARE UPDATING
To update the firmware release of the FOS 100 POWER SOLO you need:
- DTS Dongle Firmware Uploader (code 03.LA.206).
- “DTS Firmware Upgrade Utility v.2.02” program installed on PC.
- Latest firmware release available for FOS 100 POWER SOLO unit.
Updating the firmware release.
Please follow the procedure below to perform the update:
1. Connect the DTS Dongle Firmware Uploader to a spare USB port on the PC.
2. Connect the unit DMX input to the DTS Dongle Firmware Uploader DMX output with a
standard DMX cable and turn ON the unit.
3. Send the new firmware release into the unit by using “DTS Firmware Upgrade
Utility v.2.02” program. At the end of the procedure, the unit will reset.
For more information please refer to an authorised DTS service centre.
This manual suits for next models
1
Table of contents
Other DTS Floodlight manuals

DTS
DTS EVO User manual

DTS
DTS SCENA LED 200 CT FR User manual

DTS
DTS XR1200 WASH Fresnel User manual

DTS
DTS XR3000 SPOT CMY User manual

DTS
DTS Dmx Strobe 1500 User manual

DTS
DTS SCENA COMPACT HALOGEN 300W User manual

DTS
DTS SCENA LED 80 PC FC User manual

DTS
DTS MINI FOCUS LED PROJECTOR User manual

DTS
DTS XR7 WASH User manual

DTS
DTS FLASH 2000L User manual
Popular Floodlight manuals by other brands

Francis Searchlights
Francis Searchlights A7195 VL500 150w 24v LED User instruction & installation manual

EuroLite
EuroLite LED PFE-120 3000K user manual

ADJ
ADJ WiFly QA5 IP User instructions

Anslut
Anslut 019924 Original instructions

Renkforce
Renkforce Merida operating instructions

Milwaukee
Milwaukee M12 AL Operator's manual