manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DTS
  6. •
  7. Floodlight
  8. •
  9. DTS XR1200 WASH Fresnel User manual

DTS XR1200 WASH Fresnel User manual

Other manuals for XR1200 WASH Fresnel

1

Other DTS Floodlight manuals

DTS FLASH 2000L User manual

DTS

DTS FLASH 2000L User manual

DTS MINI FOCUS LED PROJECTOR User manual

DTS

DTS MINI FOCUS LED PROJECTOR User manual

DTS XR3000 SPOT CMY User manual

DTS

DTS XR3000 SPOT CMY User manual

DTS PHARUS User manual

DTS

DTS PHARUS User manual

DTS Dmx Strobe 1500 User manual

DTS

DTS Dmx Strobe 1500 User manual

DTS EVO User manual

DTS

DTS EVO User manual

DTS SCENA LED 200 CT FR User manual

DTS

DTS SCENA LED 200 CT FR User manual

DTS SCENA COMPACT HALOGEN 300W User manual

DTS

DTS SCENA COMPACT HALOGEN 300W User manual

DTS SCENA LED 80 PC FC User manual

DTS

DTS SCENA LED 80 PC FC User manual

DTS FOS 100 POWER FC User manual

DTS

DTS FOS 100 POWER FC User manual

DTS XR7 WASH User manual

DTS

DTS XR7 WASH User manual

DTS XR8 SPOT User manual

DTS

DTS XR8 SPOT User manual

DTS TITAN PLUS SOLO User manual

DTS

DTS TITAN PLUS SOLO User manual

Popular Floodlight manuals by other brands

V-TAC VT-5192S installation instructions

V-TAC

V-TAC VT-5192S installation instructions

Major tech HLF30CW instruction manual

Major tech

Major tech HLF30CW instruction manual

EuroLite LED Cube user manual

EuroLite

EuroLite LED Cube user manual

EuroLite LED IP FL-100 SMD user manual

EuroLite

EuroLite LED IP FL-100 SMD user manual

Cooper Wheelock XB12 specification

Cooper Wheelock

Cooper Wheelock XB12 specification

Allen + Roth 17624-000 user manual

Allen + Roth

Allen + Roth 17624-000 user manual

ADJ 4 STAGE PAK User instructions

ADJ

ADJ 4 STAGE PAK User instructions

Cooper Lighting EGL91SW233 Specification sheet

Cooper Lighting

Cooper Lighting EGL91SW233 Specification sheet

Max 37496 instruction manual

Max

Max 37496 instruction manual

BEGA 85 143 Instructions for use

BEGA

BEGA 85 143 Instructions for use

Cameo CLPST64Q8W user manual

Cameo

Cameo CLPST64Q8W user manual

Beamz 151.226 user manual

Beamz

Beamz 151.226 user manual

EuroLite LED IP FL-8 user manual

EuroLite

EuroLite LED IP FL-8 user manual

Ledj PERFORMER 36 RGB user manual

Ledj

Ledj PERFORMER 36 RGB user manual

Perel ELS3 user manual

Perel

Perel ELS3 user manual

Perel ELS3WD user manual

Perel

Perel ELS3WD user manual

Xtricity 4-80053 instructions

Xtricity

Xtricity 4-80053 instructions

Stahl 6521/4 Series operating instructions

Stahl

Stahl 6521/4 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

GB
Made in Italy
XR1200 WASH
User’s Manual Rel 3.0
D.T.S. Illuminazione srl - ITALY
http://www.dts-lighting.it
03.MW005.EB.L
XR1200 WASH FRESNEL
03.MW005.EB.PC.L
XR1200 WASH PC
Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso
scritto della D.T.S.
DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di
design a ciascun proprio prodotto. D.T.S. non assume alcuna responsabilità sull’uso o sull’applicazione dei
prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products
without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits
described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de D.T.S.
D.T.S. se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou
de design, sans préavis, à chacun de ses produits. D.T.S. décline toute responsabilité sur l'utilisation ou
sur l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y
controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.
Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado
o reproducido, total o parcialmente, sin previa autorizaciónescrita de D.T.S.
D.T.S. se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter
estético, funcional o de diseño a cada producto suyo. D.T.S. no se asume responsabilidad de
ningún tipo sobre la utilización o sobre la aplicació
n de los productos o de los circuitos descritos.
ARC 1200
2XR1200 WASH
ARC 1200
3
INDEX:
1- SYMBOLS 4
2- GENERAL WARNING 4
3- GENERAL WARRANTY CONDITION 4
4- TECHNICAL FEATURES 5
5- ACCESSORIES 6
6- IMPORTANT SAFETY INFORMATION 7
6.1 Fire prevention
6.2 Prevention of electric shock
6.3 Protection against ultraviolet radiation
6.4 Safety
6.5 Level of protection against the penetration of solid and liquid matter
7- MOUNTING THE LAMP 8
3.1 Lamp alignment
8- VOLTAGE AND FREQUENCY 9
9- INSTALLATION 9
9.1 Safety cable
9.2 Protection against liquids
9.3 Movement 10
9.4 Risk of fire
9.5 Forced ventilation
9.6 Ambient temperature
10- MAINS CONNECTION 10
10.1 Protection
11- DMX SIGNAL CONNECTION 11
11.1 DMX Addresses
11.2 Selecting the DMX address
12- FIRMWARE UPDATING 12
13- DISPLAY FUNCTIONS 13
14- ERROR MESSAGES 16
15- HIDDEN MENU 17
16- OPENING THE PROJECTOR HOUSING 18
17- PERIODIC CLEANING
17.1 Lenses and reflectors
17.2 Fans and air passages
18- PERIODIC CONTROLS
19- DMX PROTOCOLS 19
20-COLOUR WHEEL 24
21- 8 MOTORS CONTROL CARD 25
22- PAN & TILT CARD 26
23-CABLES RESEND CARD
24-DISPLAY CARD
25- LAMP ON-OFF CONTROL CARD
XR1200 WASH
1- SYMBOLS
Graphic symbols used on this manual
2- GENERAL WARNING
Read the instruction contained in this user manual carefully, as they give important information
regarding safety during installation , use and maintenance.
The device is not for domestic use and must be installed by a qualified electrician or experienced
person.
Always disconnect the device from the mains before replacing the lamp.
The lamp must be replaced if it has been damaged or deformed by prolonged use or overheating.
The device must always be equipped with an efficient ground connection.
3- GENERAL WARRANTY CONDITIONS
The unit is guaranteed for 36 months from the date of purchase against manufacturing material
defects.
THIS SYMBOL INDICATES A HOT SURFACE
THIS SYMBOL INDICATES ELECTRIC SHOCK RISK
THIS SYMBOL INDICATES GENERAL RISK
THIS SYMBOL MEANS “DO NOT PLACE THE UNIT ON
INFLAMMABLE SURFACES”
2M THIS SYMBOL INDICATES THE MINIMUM DISTANCE TO
BE KEPT BETWEEN THE DEVICE AND THE LIT OBJECT
F
THIS SYMBOL MEANS “RADIATION FROM THIS LAMP
CAN CAUSE DAMAGE TO EYES AND SKIN”
!
UV
ARC 1200
4XR1200 WASH
ARC 1200
5XR1200 WASH
4- TECHNICAL FEATURES
The XR1200 WASH is a moving head fitted with a Philips MSR Gold 1200W Fastfit discharge lamp
(95.000 Lumens) combined with a dichroic parabolic reflector.
The XR1200 WASH incorporates motorized zoom (20°- 45° FRESNEL LENS MODEL / 9°-19° PC LENS
MODEL), rotating indexable beam shaper (0°-180°), frost filter, CMY colour generation system, colour
wheel with linear selection for perfect 2-colour beams (6 dichroic filters + 2 colour conversion filters
3.200°K and 5.600°K +open) and electronic ballast. The XR1200 WASH also includes a new Pan / Tilt
locking system with recessed buttons. The XR1200 WASH is particularly suitable for all professional
applications, both mobile (concerts, shows, tours, special events) and fixed (clubs and other venues),
requiring a light with extremely luminous output capable of illuminating objects and large backgrounds
with an endless variety of colours.
Electronic ballast 90-260V 50/60 Hz• Black colour
All models are also available in white colour
Lamp
Lamp: Philips MSR Gold 1200 Fastfit . Automatic switching on of lamp in case of accidental switching off
Lamp on/off via DMX; reset via DMX.
Optical group
27.000 Lux at 5 m (20°). Fresnel lens Ø 200 mm.
.000 Lux at 5 m ( °). PC lens Ø 150 mm.
Borosilicate dichroic parabolic reflector
Zoom
Motorized zoom (20°- 45°)
Motorized zoom ( °- 19°)
Dimmer / shutter / strobo
Linear dimmer, Shutter, Strobe from 0,85 flash/sec to 10 flash/sec
Power saving mode (the lamp dims to 50% six seconds after shutter closure)
Colours
CMY color generation system with 3 palettes + colour wheel (6 colours + 2 colour conversion filters +
open) with linear selection for perfect 2-colour beams. Color change with blackout sync
Effects
Rotating and indexable beam shaper (0°-180°)
Pan / Tilt
Pan 540° (2,9 sec.). Tilt 270° (1,8 sec.). 16-bit resolution
8 selectable speed ranges (8 selectable pan/tilt speeds); extremely smooth and precise movements even
at the highest speeds. Pan / Tilt locking system with recessed buttons. Automatic Pan/Tilt repositioning
in case of knocks
16 DMX channels
Internal operating system updatable via DMX
INTERFACE
LCD backlit graphic display (128x64)
Connections
4 XLR connectors (3-pole In and Out; 5-pole In and Out) by Neutrik
Power supply
Electronic ballast: 90 - 260 V (50/60 Hz); power consumption: 1320 W
Thermal
Operating ambient temperature: -10° / 40°
XR 1200 WASH FRESNEL (Cod. 03.MW005.EB.L)
XR 1200 WASH PC (Cod. 03.MW005.EB.PC.L)
XR 1200 WASH FRESNEL:
XR 1200 WASH PC: 104 9
XR 1200 WASH FRESNEL:
XR 1200 WASH PC: 9
Weight
38 Kg (Electronic Ballast)
ARC 1200
6XR1200 WASH
490 mm 460 mm
60 mm
4
685 mm
430 mm 500 mm
270°
4- TECHNICAL FEATURES
Dimensions
5- ACCESSORIES
As standard
•1 x MSR Gold 1200 Fastfit lamp
•1 x POWERCONN male cable connector (cod. 0520P014)
•1 x XLR 5 Pins male cable connector (cod. 0508B028)
•1 x XLR 5 Pins female cable connector (cod. 0508B027)
•2 x “C” Clamp GQUICK with “Fast Lock” connection 1/4 turn (max. load. 80Kg) (cod. 0521A014)
•1 x FROST filter (cod. 0506V016 )
• User’s manual
Optional (on request)
• Wireless DMX receiver card (cod. 03.LA.012)
• “C” Clamp G60 black (max. load 50Kg) (cod. 0521A004)
• “C” Clamp G60 chrome (max. load. 50Kg) (cod. 0521A004.20)
• “C” Clamp GQUICK with “Fast Lock” connection 1/4 turn (max. load. 80Kg) (cod. 0521A014)
• “C” Clamp G100 black / professional (max. load. 200Kg) (cod. 0521A015)
• Omega clamp with “Fast Lock” connection 1⁄4 turn (cod. 02K00467)
• Safety wire (3mm x 60 cm), ring spring catch, max. capacity load 60Kg (cod. 0521A010)
Unit Dimensions (LxWxH)
500 x 490 x 685mm
Weight: 38 Kg
Packaging Dimensions (LxWxH)
580 x 490 x 800 mm
Weight: 43 Kg
7
6- IMPORTANT SAFETY INFORMATION
6.1 Fire prevention:
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with fuses of identical value. Refer to the wiring diagram if
there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
6.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves
touching the inside of the moving head, including lamp replacement.
-The level of technology present in the XR1200 requires the assistance of specialised personnel for all
servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
6.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses, filters or ABS covering is damaged. Their respective
shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
6.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of
supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main
fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at
least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should
not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
6.5 Level of protection against the penetration of solid and liquid matter:
-The projector is classified as an ordinary appliance and its protection level against the penetration of
solid and liquid matter is IP 20.
For outdoor use, D.T.S. reccomend the use of the dedicated raincovers:
• Raincover for XR1200 base (top) (cod. 03.MA009)
• Raincover for XR1200 base (bottom) (cod. 03.MA010)
XR1200 WASH uses a Philips MSR Gold 1200 Fastfit lamp.
XR1200 WASH
2M
F
!
!
UV
7- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
1) Using a screwdriver, loose the 3 screws A, B, C, (photo 1) and remove the metal cover .
2) Insert the lamp (photo2).
3)Rotate the lamp 1/4 turn clockwise (photo 3 and 4).
The lamp used on XR1200 is made in quartz glass and should be handled with care. Always follow the
instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided
in the lamp's packaging. The lamp socket is not symmetrical.
DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat
the procedure.
4) Replace the metal cover and tighten the screws A,B,C, which where previously removed.
WARNING: Never look directly at the lamp when it’s lit.
Discharge lamps emits UV rays; radiation from this lamp can cause damage to eyes and skin.
7.1 Lamp alignment
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic
filters and other components inside the unit. The lamp alignment is also essential to obtain the
maximum unifirmity and luminous performance by the projection.
3 adjusters X, Y and
Z (photo 5)
you will have an evenly projected light beam, with no shadows or
zones wich are brighter than others.
Philips MSR Gold 1200 Fastfit
Power 1200W
Luminous flux 95,000 lm
Colour temperature 6.300°K
Lampbase PGJX50
Rated life 750 hours
PGJX50
1) Mount the fixture in an orientation so that it may be squarely projected onto a smooth white surface
no less than 3 meters away. 2) Using a console or the menu system, focus an open (white) beam onto
the surface and observe the beam. 3) Using a phillips-head screw driver, rotate the
until you achieve a uniform flat field.
When the lamp is correctly optimized,
8
Photo 2Photo 1 Photo 4Photo 3
XR1200 WASH
UV
Photo 5
Lamp
Alignment
Normal Hot Spot
8- VOLTAGE AND FREQUENCY
The XR1200 with electronic ballast can operate at 90-260 VOLT 50 or 60 Hz.
9- INSTALLATION
XR1200 may be either floor or ceiling mounted.
For floor mounting installations, the XR1200 is supplied with four rubber mounting feet on the base.
For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the
mounting surface.
The supporting structure from which the unit is hung should be capable of bearing the weight of the
unit, as should any clamps used to hung it. The structure should also be sufficiently rigid so as not to
move or shake whilst the XR1200 is moving.
Eight quarter turn fast locks placed on the base of the units,allows by using the two fast lock C clamps
provided in the box, to fix the unit in any position.
.
9.1- Safety cable
We recommend the use of a safety cable or chain connected to the XR1200 and to the suspension truss
in order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron
cable or chain can bear the weight of the entire unit.
You may attach the safety chain to the two holes (A) located on the base of the fixture, as shown in the
picture below.
9.2- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come
into contact with oil, water or any other liquid. The proper unit functioning would be compromised
should this occur.
9XR1200 WASH
A
!
9.3- Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any
obstructions in the path of the projector's movement.
9.4- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended
distance from flammable material is 1 MT.
Minimum distance from the object being illuminated is 2 MT.
9.5- Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the
base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the
projector is in operation.
Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
9.6- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature
should NOT exceed 40°C.
10- MAINS CONNECTION
XR1200 with electronic ballast operate at 90-260 VOLT 50-60 Hz.
Prior to connecting the unit to your mains supply,
ensure that the model in your possession correctly matches
the mains supply available. For connection purposes,
ensure that your plug is capable of supporting 8 amps at 230V,
Or 16 amps at 100-120 V
Strict adherence to regulatory norms is strongly recommended.
10.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each XR1200.
A good earth connection is essential for the correct operation of the projector.
10
Electronic ballast
90-260V 50 / 60Hz
XR1200 WASH
540°
270°
F
!
WARNING
Do not place any object in the path
of the projector’s movement