If performance is reduced, adjust this setting
back to where it was originally set. If unsure
please contact our service department before
you alter any of the settings.
Heat Recovery. This automatically increases
the fan speed (air supply rate) when there
is enough heat to recover from the ceiling,
and the house is not yet at, or above the Set
Temperature (measured at the keypad).
Standard setting = 'ON' 7 segments.
Note: Heat Recovery and Heat Retention
settings automatically adjust fans speeds
once they are set. They can also be adjusted
at any time.
Hum. Settings. For adjusting the sensitivity
of the system to an air supply which is more
humid than the air inside the home.
Hum. Settings - Hum. Sens. Sets the level
of sensitivity of the system to the supply air
being more humid than the air inside the home.
Ranging from OFF, LOW, MED, Hi (high), V Hi
(very high).
Standard setting = 'Hi'.
Hum. Settings - Hum. Time. Sets the time the
system will allow supply air to be more humid
than the inside air. So; this setting creates
a delayed reaction, ranging from Instant, V
Hi (15mins), Hi (30mins), Med (45mins), Low
(60mins).
Standard setting = 'Instant'.
Note: Altering the Humidity Settings will alter
the behavior of your system. If performance is
reduced, adjust this setting back to where it
was originally set. If unsure please contact our
service department.
Fan Boost. When in Fan Boost, the system
will operate at maximum speed (max air supply
rate) for a set amount of time, and then it will
revert back to condensation control speed.
Utilities
For access to: Setting the System Clock,
turning the Backlight On/O, setting the
System Timer, Resetting the Filter Timer,
viewing Temperature and Humidity graphs and
System Diagnositics.
Optional Features
These includes the Tempervent Air warmer.
To access the optional features (if tted):
Press the MENU button. (This changes the
screen to the rst menu) Then move the
highlight by using the arrows to select
the desired option and press to select that
option.
Mode: The way you want the optional feature
to be activated. (Follow the prompts at the
bottom of each screen to help you set these.)
Recommended Settings
Air Warmer:
Cooler months = 'ON - Mode = Temp (8oC) +
Timer (ON 2100 / OFF 0700).
Fan Speed = (MED).
Note: This limits the time on and the air supply
temperature below which the feature will
operate.
Warmer months = 'OFF'.
Fan Speed: The Fan Speed the optional feature
will run at when it is on.
Remember: Where you leave the highlight is
the mode in which the feature will switch on. If
a feature is currently active, it will show on the
home screen in red.
Other Settings
You are able to choose alternative modes of
operation for the above optional feature. If
system performance reduces, please revert to
the recommended settings.