manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DVTEL
  6. •
  7. IP Camera
  8. •
  9. DVTEL CB-5222 User manual

DVTEL CB-5222 User manual

Other DVTEL IP Camera manuals

DVTEL Quasar CM-4221-00 Manual

DVTEL

DVTEL Quasar CM-4221-00 Manual

DVTEL CT-5322F Manual

DVTEL

DVTEL CT-5322F Manual

DVTEL 9501-M4-N/P User manual

DVTEL

DVTEL 9501-M4-N/P User manual

DVTEL CF-4221-00 Troubleshooting guide

DVTEL

DVTEL CF-4221-00 Troubleshooting guide

DVTEL ioi HD CB-5222 Manual

DVTEL

DVTEL ioi HD CB-5222 Manual

DVTEL 9540 User manual

DVTEL

DVTEL 9540 User manual

DVTEL Quasar Gen II CB-6204 User manual

DVTEL

DVTEL Quasar Gen II CB-6204 User manual

Popular IP Camera manuals by other brands

Challenger Smart Force ASFCAM2 quick start guide

Challenger

Challenger Smart Force ASFCAM2 quick start guide

Foscam FI8903W user manual

Foscam

Foscam FI8903W user manual

BenQ DVY22 user manual

BenQ

BenQ DVY22 user manual

Avigilon H4A-BO1-IR installation guide

Avigilon

Avigilon H4A-BO1-IR installation guide

Digital Watchdog DWCA-C128-64 manual

Digital Watchdog

Digital Watchdog DWCA-C128-64 manual

Ganz ZN8 Series user manual

Ganz

Ganz ZN8 Series user manual

ShareTech AV1 user manual

ShareTech

ShareTech AV1 user manual

HOME8 V33040US quick start guide

HOME8

HOME8 V33040US quick start guide

Ezviz C6C quick start guide

Ezviz

Ezviz C6C quick start guide

Melchioni UCAM 2015 manual

Melchioni

Melchioni UCAM 2015 manual

Zxtech Tropox user manual

Zxtech

Zxtech Tropox user manual

Arecont Vision MegaBall AV3146DN-3310-D-LG installation manual

Arecont Vision

Arecont Vision MegaBall AV3146DN-3310-D-LG installation manual

Mitel 6800i Series Administrator's guide

Mitel

Mitel 6800i Series Administrator's guide

Vitek VTC-IR403-212NP quick start guide

Vitek

Vitek VTC-IR403-212NP quick start guide

THOMSON DSC - 323W user guide

THOMSON

THOMSON DSC - 323W user guide

ACTi TCM-5311 Hardware user manual

ACTi

ACTi TCM-5311 Hardware user manual

Eneo MCB-64A0003M0A Quick installation guide

Eneo

Eneo MCB-64A0003M0A Quick installation guide

deView electronics CBDNI36F instruction manual

deView electronics

deView electronics CBDNI36F instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick Install Guide
CB-5222 Analytic Bullet IP Camera
1. From the navigation bar, select Settings > Camera > Misc.
2. From the TV System dropdown list, select the required video
format (PAL NTSC). The default video format is PAL.
3. Click SE to save settings. The unit resets and the new setting
is configured.
4. From the Live screen, adjust the Zoom so that it includes the
required Field of View.
5. Focus the lens automatically or manually.
NO E: Changing the video format restores the unit to factory
defaults and deletes any analytic configuration that was set
previously.
1. Select one of the following power connections:
• Connect the Ethernet cable on the system cable from the
camera to a PoE+ switch injector
(for operation at -40° to 50° C -40° to 122°F)
• Connect the camera’s power cable to a 12VDC (1.6 amps),
24 VDC (0.8 amps), or 24VAC (0.85 amps) power supply
(for operation at -40° to 50° C -40° to 122°F)
• Connect the Ethernet cable on the system cable from the
camera to a Power over Ethernet (PoE) switch injector
(for operation at -10° to 50°C 14° to 122°F)
2. Connect the analog video, audio in, audio out, alarm cables
as required for your system.
You can also select the video format in DNA from the context
menu by clicking Change Video Format, or from the Device
Properties screen of the Properties tab.
1. Download DNA from http: www.dvtel.com services-support firmware-
software .
2. Click the DNA icon and run the DNA utility (DNA.exe). DNA discovers all
devices on the same VLAN and displays the device’s current IP address. DNA
version 2.1.x.x and above supports CB-5222.
3. Do one of the following:
a. If you know the unit’s IP address, enter the IP address in your browser
(Internet Explorer 8 and above). The units’ Login window opens.
b. If you do not know the unit’s IP address, double-click the units in DNA’s
Discovery List. The unit’s Login window opens in your browser.
NO E: Refer to the DNA 2.1 User’s Manual for details how to use DNA.
PoE PoE+
AC DC
4. Enter the user name (“admin”) and password (“admin”). The device’s
web interface opens.
Notice: Failure in part or in hole of the installer, o ner, or user in any ay to follo the prescribed procedures or to heed arnings and cautions
provided in the installation and user manual shall absolve DVTEL and its agents from any resulting liability.
Warning: THIS EXAMPLE IS FOR DEMONSTRATION PURPOSES ONLY. For deployment in live applications, such as security, safety and loss prevention
programs, installers, owners and users should read and follow the installation and user manual prescribed procedures provided. Installation should
follow safety, standards, electrical codes and security best practices as well as the laws that apply where the units are being installed.
P N MA0605-30-00
CB-5222_QIG_Jan. 13_2016
DVTEL, Inc. 65 Challenger Road Ridgefield Park, NJ 07660
Tel: 201-368-9700 Fax: 201-386-2615 Order Fax: 201.712.0343
[email protected] www.dvtel.com
1. From the navigation bar, select LIVE.
2. Select ARM. The camera is ready to use.
From the navigation bar, select Analytic > Rules.
A rule for detecting humans or vehicles entering the
scene (blue masked area) is defined by default.
You can activate rules, modify settings, delete, or
add a new rule.
To create a new rule:
1. Click NEW.
2. Select the rule type by clicking the link.
3. Draw on the video scene where you want the
detection to take place.
4. Define the attributes for detection from the Basic
and Advanced tabs.
5. When finished, click APPLY to save the settings.
From the navigation bar, select the Settings > Analytics > Depth tab.
The web interface opens on the Depth > AU O screen.
Before starting, verify that the camera is installed at a height of at
least four meters (13 feet) and that the horizon is less than 30% of
the Field of View (FoV).
2. Select Set camera height and enter the estimated camera height.
NO E: Refer to the HTML Edition Units User’s Guide to learn how to use rules.
3. Click S AR . The camera automatically calibrates the depth. Be
sure that a person is walking along the Y (Vertical) axis of the FoV
while Auto Calibration is in process.
NO E:
• While Auto Calibration is in progress, you can proceed to steps
5 (select rule) and 6 (detection) below.
• The Auto Calibration finishes when the progress bar reaches
100%. If you stop the procedure before it finishes, the analytic
process will reset.
• If you change from Auto to Manual mode, you must wait until
the analytic process resets in order to use Manual mode.
NO E: Analytic performance is optimized only after the auto depth
calibration process is completed.
4. Verify that the horizon, camera height, and human marker
settings are correct.
1. From the Units drop-down list, select Feet or Meter.
5. Click MANUAL and finish configuring depth settings.