Dymec DY-HI8011-90bt User manual

DYMEC
User Manual-DY-HI8011-90bt
Hardened Industrial 802.3bt Gigabit POE Injector, 1 x 10/100/1000M TX 90W PSE + 1 x 10/100/1000M TX,
52-56 VDC input, Operating Temp.: -40°C to +75°C
FCC MARKING
This Equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received; including interference that may
cause undesired operation.
CE MARKING
This equipment complies with the requirements relating to electromagnetic
compatibility, EN 55032/24 class A for ITE, the essential protection requirement of
Council Directive 2014/30/EU on the approximation of the laws of the Member States
relating to electromagnetic compatibility.
DYMEC Inc. has an on-going policy of upgrading its products and it may be possible
that information in this document is not up-to-date. Please check with your local
distributors for the latest information. No part of this document can be copied or
reproduced in any form without written consent from the company.
Trademarks:
All trade names and trademarks are the properties of their respective companies.
Copyright © 2020 DYMEC, All Rights Reserved.
1

DYMEC
2
NOTE
Always make sure the total length of the TX cable DOES NOT exceed 100meter. Total
length is defined as length A + length B
Length A + Length B < 100 meters
POE signal attenuates every meter, the built-in transformer allows the attenuation to reach
100 meters to follow IEEE 802.3af/at/bt standards. The higher quality PD you connect to, the
more reliable the network will be. When connecting to a poor-quality PD, it cannot generate
a strong enough signal for the remote switch. Always make sure you have a high-quality PD
to perform your desired network.
Introduction
This ultrahigh power IEEE 802.3bt 90Watts POE Injector is equipped with one IEEE
802.3af/at/bt 90W Giga PSE port to power up 90Watts PD device for camera, WiFi AP, or
LoRa applications. This high power bt device is also backward compatible with both 95W
PoH and 60W uPoE to be used as a general usage high power PoE product. This means that
this unit can be used as a general purpose solution for many high power PoE applications.
This unit is designed for high-power broadband WIFI, 802.3bt, PoH, uPoE devices, and a
broad range of applications. This unit is designed for IP surveillance, traffic monitoring,
outdoor camera and for a broad range of applications. It can tolerate -40°C to +75°C in harsh
environment to perform a reliable network.
PD
Remote Switch
A
B

DYMEC
3
Installation package
This unit can be din-rail mounted or wall-mounted. Din-rail brackets and wall-mounted
brackets are included.
Power connection
This unit provides a 4 pin terminal block. It can be operated using 52-56VDC power source.
Always make sure your input voltage is within this supported voltage range.
To connect power: This unit supports two power inputs. Follow the printed polarity for +V1-,
+V2- and ground. Connect positive wires to V+, connect negative wires to V-, and connect a
neutral wire to the ground screw.
+V1- is for power input one connection.
+V2- is for power input two connection.
Power connecting procedure:
STEP 1 – Take out 4 pin terminal block located
in the included mounting kit package.
STEP 2 – Connect power wires to +V1- or +V2-
with corresponding polarity. Connect the
grounding wire to the ground screw.
STEP 3 – Plug into terminal block socket shown
above. Polarity needs to match V+ and V-.
WARNING -- Always SHUT OFF power source to connect power wire.
WARNING -- Any exceeded input voltage will not make this unit function and may
damage this unit.
+V1- +V2-

DYMEC
4
LED indicator
PoE (Amber)
ON – PD is detected on designated port.
OFF – no PD is detected
PW2 (Green)
ON – Power is detected
OFF – Power is not detected
PW1 (Green)
ON – Power is detected
OFF – Power is not detected

DYMEC
5
Specifications
IEEE Standard
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Fast Ethernet
IEEE 802.3ab 1000Base-T Gigabit Ethernet
IEEE 802.3af for POE
IEEE 802.3at for POE+
IEEE 802.3bt
Compliant with 60W uPoE standard
Compliant with 95W Power over HDBaseT (PoH)
standard
Network Connector
1xRJ-45 10M/100M/1000MBaseT(X) Data
1xRJ-45 10M/100M/1000MBaseT(X) Data with 90W POE
Output Power
Network Cable
UTP/STP above Cat.5e Cable
EIA/TIA-568 10-ohm (100m)
Protocol
CSMA/CD
LED
PW1 (Green): ON-Power is detected
PW2 (Green): ON-Power is detected
PoE (Amber): ON – 90W PSE is in active mode.
OFF – PSE is in idle mode.
POE Pin Assignment
Pin 1 (V-), 2 (V-), 3 (V+), 6 (V+)
Pin 4 (V+), 5 (V+), 7 (V-), 8 (V-)
Reverse polarity protection
Present
Overload current protection
Present
Power Supply
Redundant Dual DC 52V-56V Power Input
Power Consumption
1 W@52 VDC Without POE
POE power
Maximum POE power 90watts at 52VDC input
Removable Terminal Block
Provides 4 pin terminal block
Wire range: 0.34mm^2 to 2.5mm^2
Solid wire (AWG):12-24/14-22
Stranded wire(AWG): 12-24/14-22
Torque:5lb-In/0.5Nm/0.56Nm
Wire Strip length: 7-8mm
Operating Temperature
-40°C to 75°C
Operating Humidity
5% to 95% (Non-condensing)
Storage Temperature
-40°C to 85°C
MTBF (mean time between failure)
716,686 hrs (Telcordia (Bellcore), GB) at 40°C
Housing
Rugged Aluminum, IP30 Protection
Case Dimension (L X W X D) mm
103.5 x 32 x 81.5 mm (L x W x D)
Installation
DIN Rail Mount or Wall Mount
Certifications
Safety
LVD(EN60950-1)
EMC
CE, FCC, EN 55032/24

DYMEC
6
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 6KV; Air: 8KV
IEC 61000-4-4 EFT: Power: 2KV; Signal: 2KV
IEC 61000-4-5 Surge: Power: 2KV; Signal: 2KV
Vibration
EN 60068-2-6
Shock
EN 60068-2-27
Free Fall
EN 60068-2-32

DYMEC
7
Housing Dimension (mm)
NOTE:
Housing dimension is for purpose of showing product Length, Width, Height, din-rail, and
terminal block’s position and dimension. Please reference the LED Indicator Page for
correct port order.
Table of contents
Popular Laboratory Equipment manuals by other brands

Korona
Korona 1000 installation manual

Terra Universal
Terra Universal Smart Desiccator Installation and operating guide

Izon
Izon AUTOMATIC FRACTION COLLECTOR V1 quick start guide

Molecular Devices
Molecular Devices SkanStacker 300 user guide

Conrad
Conrad 97 52 27 operating instructions

Kulzer
Kulzer Technomat operating manual