- 7 -
§Check the configuration settings in the bridge,
-Bridge and EP have the same “Privacy
Key”.
-“Host Limit” for each EP is not zero.
-“HPNA” port for each EP is not disabled.
For unmatched “Privacy Key”, it is not possible
to send/receive data between the bridge and
each EP. (Web browser shows red background
for unmatched EP row in “EP Management”
configuration window).
If “Host Limit” of EP is 0 (zero) or “HPNA”
port is disabled, the EP is not allowed to
send/receive data.
§Check the physical connection quality between
the bridge and each EP by diagnosis tools.
§If the connection quality is not good enough,
please review the whole coax segment,
-Wiring topology: not across amplifier.
-Total path attenuation: including mixer,
combiner, splitter and tap.
-Noise sources: as cannot co-exist with
DOCSIS signal.
§Check the Firmware version of the bridge and
EPs.
Can not transmit/receive data between EPs:
§For security, it is intentionally designed to
block the communication between EPs.