E-Clear MK7/CF1-75 User manual

0"
USER MANUAL
POOLS • DRINKING WATER • POND
MK7/CF1-75 • MK7/CF1-75UV • Pools up to 75m3
MK7/CF1-150 • MK7/CF1/150UV • Pools up to 150m3
MK7/CF1-250 • MK7/CF1-250UV • Pools up to 250m3
MK7/CF1-500 • MK7/CF1-500UV • Pools up to 500m3
MK7/CF1-750 • MK7/CF1-750UV • Pools up to 750m3
MK7/CF1-1000 • MK7/CF1-1000UV • Pools up to 1000m3
On Request • Pools up to 10 000m3

1"
CONTENTS
"______________________________________________________________________________________""
Section 1: General Information .................................................................................... 3
1.1. Safety .......................................................................................................................... 3
1.2. Product Overview ......................................................................................................... 3
1.3. Model Description ......................................................................................................... 3
Section 2: Specifications ............................................................................................. 3
2.1. Electronic Box .............................................................................................................. 3
2.2. Electrode Chamber (inline and assembly versions) .......................................................... 3
2.3. Ultraviolet Chamber ...................................................................................................... 3
Section 3: Installation ................................................................................................. 4
3.1 Unpacking -
What's in the box
....................................................................................... 4
3.2 Switches Orientation .................................................................................................. 5-6
3.3 Connections ................................................................................................................. 6
3.3.1. Electrodes connections ................................................................................................. 6
3.3.2. Large Box and assembly ............................................................................................... 7
3.3.3. UV connections ............................................................................................................ 7
3.3.4. e-Clear water purification systems technical specifications ............................................... 8
3.3.4.1. General specifications ................................................................................................... 8
3.3.4.2. Specifications per model .......................................................................................... 9-11
Section 4: System Start-up ....................................................................................... 11
4.1 Controls Orientation ................................................................................................... 11
4.2 Controls Description ................................................................................................... 11
4.3 Large Box Control Orientation ..................................................................................... 12
4.4 Water Preparation - IMPORTANT ............................................................................. 12
4.4.1. Calcium ..................................................................................................................... 12
4.4.2. pH ............................................................................................................................. 12
4.4.3. Copper residual ..................................................................................................... 12-13
4.4.4. Filtration ............................................................................................................... 13-14
Section 5: Standard Operation .................................................................................. 14
5.1 Oxidation (black electrodes, white cable, 2 pin) ............................................................ 14
5.2 Ionization (pink electrodes, black cable, 3 pin) ............................................................. 14
5.3 Ultraviolet .................................................................................................................. 14
Section 6: Maintenance ............................................................................................. 14
6.1 General maintenance ................................................................................................... 14
6.2 Electrode cleaning .................................................................................................. 14-15
6.3 Electrode replacement ................................................................................................. 15
6.4 UV lamp replacement ................................................................................................... 15
6.5 Repair/ Spares service ................................................................................................. 16
Section 7: Certification and Limited Warranty .......................................................... 17
7.1 Patent ....................................................................................................................... 17
7.2 Limited Warranty ........................................................................................................ 17
Section 8: Installation and Maintenance guide for eClear pools .............................. 18
8.1. Installation Guide ....................................................................................................... 19
8.1.1. Physical Installation .................................................................................................... 20
8.1.2. Water Balancing ......................................................................................................... 21

2"
8.1.3. eClear Pump and Filter Guidelines ................................................................................ 22
8.1.4. Technical Installation Guidelines for eClear Water Sanitizers ..................................... 23-36
8.2. Maintenance Guide ..................................................................................................... 37
8.2.1. Weekly Maintenance ................................................................................................... 38
8.2.2. Annual Maintenance ................................................................................................... 38
8.2.3. Water parameters ...................................................................................................... 38
8.2.4. Do’s and Don’ts ..................................................................................................... 39-40
8.2.5. Common issues .......................................................................................................... 41
8.2.6. What can I add to my e-Clear pool? ............................................................................. 41
Section 9: Problem solving guide .............................................................................. 42
9.1 Problems with pool ....................................................................................................... 43
A. Water ......................................................................................................... 43-44
B. Walls .......................................................................................................... 45-46
C. Other .............................................................................................................. 46
D. Chemicals ........................................................................................................ 47
Section 10: Spare Parts ............................................................................................. 48
10.1. Spare parts .................................................................................................................. 49
10.2. Oxygenating, Ionization, and UV .................................................................................... 50
Section 11: Drinking water systems ......................................................................... 51
11.1. Can you trust e-Clear? .................................................................................................. 52
11.2. Eco-Fusion™ One-Tap Drinking Water System ................................................................ 54
11.2.1. 10ꞋꞋ Big Blue Filter housing ...................................................................................... 54-55
11.2.2. Melt blown 5 Micron pre-filter ........................................................................................ 55
11.2.3. 10ꞋꞋ Big Blue Carbon Block Filters .............................................................................. 55-56
11.2.4. UV T5 16W High output UVC with quartz sleeve .............................................................. 56
11.3. Eco-fusion whole house drinking water systems - Images System Components ................. 58
11.3.1. Eco-fusion drinking water systems – Technical specifications ............................................ 59
11.3.2. System Components ..................................................................................................... 59
11.3.2.1. 20ꞋꞋ Big Blue high flow filter housing ....................................................................... 59-60
11.3.2.2. Melt blown 5 Micron pre-filter ...................................................................................... 60
11.3.2.3. 20ꞋꞋ Big Blue carbon block filters .................................................................................. 61
11.3.3. KDF Filters ............................................................................................................... 62-63
11.3.3.1. KDF 55 ...................................................................................................................... 64
11.3.3.2. KDF 85 ...................................................................................................................... 64
11.3.4. Siliphos filter ................................................................................................................. 65
11.3.5. 55watt UVC high spectrotherm lamp ............................................................................... 66
11.3.6. e-Clear high output oxygen & copper ionization chambers – Science explanation ............... 67
11.4. e-Clear Eco-Fussion™ rainwater harvesting kit ................................................................... 69
11.4.1. Rainwater Harvesting Averages for South Africa .............................................................. 70
11.4.2. Specifications for Rainwater Harvesting kit ...................................................................... 70
11.4.3. 10 000L Storage tank .................................................................................................... 70
11.4.4. Davey 600KPA 90L/M Pump ........................................................................................... 70
11.4.5. Davey Rainbank/ Torrium sensor valve ........................................................................... 70
11.4.6. 3 Bag glass media filter ................................................................................................. 70
11.4.7. 0.75kw Pool pump ......................................................................................................... 70
11.4.8. Additional 5 000L storage tank ....................................................................................... 70
11.4.9. Additional Davey 0.75kw submersible pump .................................................................... 71
11.4.10. e-Clear high output oxygen & copper ionization chamber ............................................... 71

3"
SECTION 1: GENERAL INFORMATION
_________________________________________________
1.1 Safety
Please read this entire manual before unpacking, setting up or operating this equipment. Pay
attention to all danger and caution statements. Failure to do say could result in serious injury
to the operator or damage to the equipment. To ensure that the protection provided by this
equipment is not impaired, do not install this equipment in any manner other than that
specified in this manual.
1.2 Product Overview
The e-clear 100% Chlorine free New Generation 7 series- provides multiple forms of toxic free
oxygen which splits into 4 powerful oxidisers (01)- (02)- (OH)- (H2O2).
These chemically free oxidisers are produced from and delivered directly into, the water
stream, in grams per minute via Electronic Oxidation. This, combined with ultraviolet (optional)
and ionization, provides the most advanced, most efficient, toxic free purification technology
available for cleaning swimming pool water. Ensuring 100% chlorine free, bacteria free, algae
free, and salt free, crystal clear water.
1.3 Model Description
MK7/CF1-75 • MK7/CF1-75UV • Pools up to 75m3
MK7/CF1-150 • MK7/CF1/150UV • Pools up to 150m3
MK7/CF1-250 • MK7/CF1-250UV • Pools up to 250m3
MK7/CF1-500 • MK7/CF1-500UV • Pools up to 500m3
MK7/CF1-750 • MK7/CF1-750UV • Pools up to 750m3
MK7/CF1-1000 • MK7/CF1-1000UV • Pools up to 1000m3
On Request • Pools up to 10 000m3
SECTION 2: SPECIFICATIONS
_________________________________________________
2.1 Electronic Box
Enclosure: IP67, PVC, splash proof.
Power (external): 230v AC, 50/60Hz input4-12v DC output
-230v output to UV ballast (if in separate box)
Operating temperature: 0 - 60 °C
Weight: 1.0 kg
2.2 Electrode Chamber (inline and assembly versions)
Enclosure: Poly vinyl Chloride (PVC)
Oxygen electrode: Titanium Composite
Ionization Electrode: Copper composite
Silver Ionization electrode: 99.99% pure silver
Connecting bolts: 316 food grade stainless steel
Operating temperature: 0-50 °C
Weight: 1.5kg - 15kg
2.3 Ultraviolet Chamber
Enclosure: 316 food grade stainless steel
Other parts: PVC
Lamp: 55 W UVC high output ultraviolet germicidal fluorescent lamp.

"
4"
SECTION 3: INSTALLATION
_________________________________________________
3.1 Unpacking -
What's in the box

"
5"
DANGER: AC mains outlets in wet or potentially wet locations must always be provided with a
ground fault circuit interrupting circuit breaker (GFCI/GFI).
3.2 Switches Orientation
Mains ON/OFF - bottom of box
Side of box:
Power&Cable"
Mains"ON/OFF"

"
6"
UV ON/OFF
Oxidation"ON/OFF"
Ionization"ON/OFF"

"
7"
3.3 Connections
3.3.1 Electrodes connections
UV"ON/OFF"Switch"

"
8"
3.3.2 Large Box and Assembly
3.3.3 UV Connections
4-"
pin"connector"at"
bottom"of"Ebox""(pre-connected)""
UV"Chamber"with"Ebox"mounted"

8"
3.3.4. eClear Water Purification Systems Technical Specifications
3.3.4.1. GENERAL SPECIFICATIONS
ULTRAVIOLET CHAMBER
Extended chamber for longer contact time to water. Removes 99.9% of all waterborne parasites and
diseases-including the deactivation of cryptosporidium. Special long life high Spektrotherm germicidal
UV lamps. 10 000hrs.
ELECTRONIC MANAGEMENT UNIT
Microprocessor technology with integrated digital display. Auto boost for increased current dosing of
oxygen/ionization electrodes. Electronic UV lamp ignition and “lamp failure indicator. Digital display
indicators for dosing output of oxygen/ionization. Fully programmable SECAM system.
90mm Oxygen Assembly
Length: 220mm
Width: 45mm
Depth: 85mm
Weight: 600g
Lug size: M6
Material: Base material – Titanium
Coating material – Proprietary coating
Patented Technology 2003/02934
Surface area: 138600mm2=1386cm2
0.139m2
Current draw: 2.2 Amps - 9 Volts
Chemical Production:
Hydroxyl ions – OH
Atomic Oxygen – O1
Oxygen - O2
Hydrogen peroxide – H2O2
90mm Copper plate
Length: 120mmX75mmX40mm
Weight: 850g
Lug size: M6
Material: Cu
Characteristics:
Biostatic
Antimicrobial
Function: Release of copper ions
Lifespan: 1-3 years
63mm Oxygen Assembly
Length: 200mm
Width: 42mm
Depth: 54mm
Weight: 300g
Lug size: M6
Material: Base material – Titanium
Coating material – Proprietary coating
Patented Technology 2003/02934
Surface area: 55 500mm2=555cm2
0.0559m2
Current draw: 2.2 Amps - 9 Volts
Chemical Production:
Hydroxyl ions – OH
Atomic Oxygen – O1
Oxygen - O2
Hydrogen peroxide - H2O2
63mm Copper Plate
Length: 100mmX46mmX25mm
Weight: 450g
Lug size: M6
Material: Cu
Characteristics:
Biostatic
Antimicrobial
Function: Release of copper ions
Lifespan: 1-3 years

"
9"
3.3.4.2. SPECIFICATIONS PER MODEL
MK – 75
Size
Inline chamber: 63mm straight
(470mm x 100mm)
Electronic box: 300mm x 180mm x 150mm
Weight
Inline chamber: 2.25kg
Electronic box: 2.7 kg
Electrical
5v •40w•2.5A
12hrs=0.3kWh/day
Flow rate:
90ℓ/ min
0.5 m/sec
MK – 75UV
Size
Inline chamber: 63mm straight
(470mm x 100mm)
UV chamber & E-box: 360mm x 980mm
Weight
Inline chamber: 2.25kg
UV Chamber & E-box: 7.3 kg
Electrical
5v •40w•2.5A
12hrs=0.3kWh/day
Flow rate:
90ℓ/ min
0.5 m/sec
MK – 150
Size
Inline chamber: 90mm straight
(470mm x 130mm)
Electronic box: 300mm x 180mm x 150mm
Weight
Inline chamber:4.5 kg
Electronic box: 2.7 kg
Electrical
5v •40w•2.5A
12hrs=0.3kWh/day
Flow rate:
300ℓ/min
1 m/sec
MK – 150UV
Size
Inline chamber: 90mm straight
(470mm x 130mm)
UV chamber & E-box: 360mm x 980mm
Weight
Inline chamber: 4.5kg
UV Chamber & E-box: 16kg
Electrical
230v•150w•2.5A
12hrs=1.5kWh/day
Flow rate:
90ℓ/min
0.5 m/sec
MK – 250
Size
Inline chambers 4 x 470mm x 130mm
E-box:400mm x 300mm x 160mm
Weight
Inline chambers: 13.5kg
E-box: 6kg
Electrical
5v•160w•10A
12hrs=1.2kWh/day
Flow rate:
1800ℓ/ min
2 m/sec

"
10"
MK – 250UV
Size
Inline chamber:4 x 470mm x 130mm
UV chamber and E-box:
500mm x 1020mm x 400mm
Weight
Inline chambers: 13.5kg
UV chamber and E-box:23kg
Electrical
230v•380w•10A
12hrs=4kWh/day
Flow rate:
1800ℓ/ min
2 m/sec
MK – 500
Size
Inline chambers: 8 x 470mm x 130mm
E-box: 2 x 400mm x 300mm x 160mm
Weight
Inline chambers: 27kg
E-box:2 x 6kg
Electrical
5v•320w•20A
12hrs=2.5kWh/day
Flow rate:
3600ℓ/min
4 m/sec
MK – 500UV
Size
Inline chamber:8 x 470mm x 130mm
2 x UV chamber and 2 x E-box:
2 x 1020mm x 500mm x 400mm
Weight
Inline chambers: 27kg
2 x UV chamber and 2 x E-box:2 x 23kg
Electrical
230v•720w•20A
12hrs=8kWh/day
Chambers:8x470mm x130m
Flow rate:
3600ℓ/min
4 m/sec
MK – 750
Size
Inline chambers: 12 x 470mm x 130mm
Weight
Inline chambers: 40.5kg
E-box:3x6kg
Electrical
5v•480w•30A
12hrs=3.6kWh/day
Flow rate:
5200ℓ/min
6 m/sec
MK – 750UV
Size
Inline chamber:12 x 470mm x 130mm
3 x UV chamber and 3x E-box:
3 x 1020mm x 500mm x 400mm
Weight
Inline chambers: 40.5kg
3 x UV chamber & 3xE-Box: 3 x 23kg
Electrical
230v•1140w•30A
12hrs=12kWh/day
Flow rate:
5200ℓ/min
6 m/sec

"
11"
MK – 1000
Size
Inline chambers: 16 x 470mm x 130mm
E-box: 4 x 400mm x 300mm x 160mm
Weight
Inline chambers: 54kg
E-box:4 x 6kg
Electrical
5v•640w•40A
12hrs=5kWh/day
Flow rate:
7200ℓ/min
8 m/sec
MK – 1000UV
Size
Inline chamber:16 x 470mm x 130mm
4 x UV chamber and 4 x E-box:
4 x 500mm x 1020mm x 400mm
Weight
Inline chambers:54kg
4 x UV chambers and 4 x E-box:4x23kg
Electrical
230v•1450w•40A
12hrs=16kWh/day
Flow rate:
7200ℓ/min
8 m/sec
SECTION 4: SYSTEM START-UP
_________________________________________________
4.1 Controls Orientation
1. Oxygen Power Indicator
2. Ionization Power Indicator
3. UV on/off Switch
4. Oxygen Dosing Dial
5. Ionic Dosing Dial
6. Ionic Program Dial
7. Quick Setup Instructions
8. Ionic Dosing Indicator
9. Oxygen Dosing Indicator
4.2 Controls Description
1. Oxygen and ionization dosing meter
2. High/ low output switch
3. Increase/ decrease dosing dial
4. Ionization output indicator
5. Oxygen output indicator
6. Polarity indicator
7. Main power on/off switch
8. Electrode power on/off
9. UV on/off
10.White cable to oxygen plates and on/off switch
11.Black cable to copper plates and on/off switch

"
12"
4.3 Large Box Control Orientation
4.4 Water Preparation - IMPORTANT
4.4.1 Calcium
-A calcium hardness of at least
250ppm
in your pool water is essential when operating the e-clear
system. This is necessary to maintain the
conductivity
of the water, thereby ensuring operational
efficiency.
-The procedure of raising the calcium hardness in the pool water should be carried out by the
installer or by a qualified pool technician making use of the prescribed test equipment.
CAUTION-the e-clear system will not operate properly without this pre-requisite calcium hardness.
4.4.2 pH
-The correct operating pH in the pool water, for the e-clear system to operate efficiently, is in the
range of
6.8- 7.2.
If the pool water's pH is allowed to rise above 7.3 for longer than 48 hours, the
water may turn green.
-A pH range of 6.8- 7.2 must be maintained if the pool water is to clean and clear. pH may need to
be adjusted as often as, every second day, or as little as once a week. This is dependent on
individual swimming pool conditions (e.g. Amount of sun, leaves or people entering the pool)
-E-clear accepts no responsibility for staining due to irregular maintenance of pool PH levels.
4.4.3 Copper Residual and Silver Residual
-A copper residual of 0.5ppm in the pool water is necessary to maintain Bacteria/algae free
conditions and maximum performance of the oxidation process. For systems with silver electrodes, a
silver residual of 50ppb is necessary. The copper and silver electrodes are linked, thus if the copper
residual reaches 0.5ppm then the silver residual will be 50ppb.

"
13"
-Upon initial operation of the e-clear system, the copper residual will take a period of time to reach
0.5ppm. In the interim, additional help is required to ensure clean and clear pool water during this
'set-up' period it is necessary to
shock treat
the water with, either, chlorine or active oxygen (until
the copper residual reaches 0.5ppm) This initial set-up period may last a couple of weeks,
depending on individual conditions.
-Once the copper residual is 0.5ppm, it is no longer necessary to shock treat the water, the pool will
run only on the e-clear system- 100% chlorine free.
-In order to achieve a copper residual of 0.5ppm quicker, it may be necessary to run the pool's
circulation pump
24 hours
, along with the e-clear system. During this initial setting up period it will
be necessary to test the copper often, until 0.5ppm is achieved.
-Once this residual is achieved the ionization may be switched off at the side of the box. Only switch
on the ionization again, when the copper residual drops below 0.5ppm. Test the copper
weekly
to
note the residual.
To test copper:
•Switch off e-clear unit power.
•Backwash and rinse filter.
•
Test pH
if not between 6.8 and 7.2, readjust pH manually by adding pool acid (see instructions
on can label). Once the pH is in the range of
6.8-7.2,
the copper may be tested.
•CAUTION- A false copper reading will occur if the pH is out of the range of 6.8-7.2
•CAUTION- during initial start-up it is necessary to circulate the pool water 24 hours a day.
Thereafter adjust the pool's timer to run according to times detailed on face of e-clear electronic
box. See below- filtration times.
•Switch e-clear unit on
•If copper residual is 0.5ppm or higher, switch off ionization (on side of electronic box). If copper
is below 0.5ppm, switch on copper until 0.5ppm is achieved.
•NOTE- Oxidation always remains on.
•CAUTION- During winter months it may be necessary to ionize less.
4.4.4 Filtration
-Pool Volume
40 - 50m3 (40 000L- 50 000L)- 6 hours
55-75m3- 8 hours
80-100m3- 10 hours (12 in very hot weather)
105-125m3- 12 hours (15 in very hot weather)
130-150m3- 15 hours (18 in very hot weather)
-Above indicates the length of time necessary to operate the e-clear system. (oxidation always on
when e-clear unit on and ionization as necessary- see Above)
-If the swimming pool is heated and is circulating 24 hours a day, it is necessary to install a separate
timer controlling the eClear system, in order to operate the e-clear system only, for the periods
shown above
CAUTION- too much oxidation will cause the pool water to appear hazy. Too much copper may stain
pool walls. These must be maintained correctly.
Hazy water
-Glass media filter may be inadequate- a minimum of between 160kg and 300kg of high quality filter
glass media is required for the e-clear system to operate effectively.

"
14"
-A deep filter bed of between 800mm and 1000mm of filter glass media is ideal. If filter is adequate
and copper residual is 0.5ppm and water is hazy, then a filter flocculant or gel bloc may be
necessary (follow instructions for use on package)
-An algaecide may also be added (see package instructions). If hazy water persists, the flow rate
through the filter may be too weak.
-A turnover of the entire pool's volume every 4 hours is necessary. This may be achieved through
use of a stronger pool pump and bigger diameter circulation pipes.
SECTION 5: STANDARD OPERATION
_________________________________________________
5.1 Oxidation (black electrodes, white cable, 2 pin)
When the e-clear electronic box is powered, the oxygen plates should always be powered, i.e. They
need never be switched off independently of the mains power. The electronic box must only be
powered when the pool water is circulating see section 4.4.4.
5.2 Ionization (Copper- pink electrodes, black cable, 3 pin)
. (Silver- 10mm diameter silver grey rod electrode, bridged to copper)
During standard operation, it is necessary to carefully gauge usage of swimming pool i.e. Body load,
amount of sunshine pool water receives and amount of debris falling into water. These factors will
determine the length of time the ionization plates are to be on. This is done by regularly testing the
copper and maintaining the 0.5ppm residual by manually switching the copper on or off at the side of
the electronic box. This also switches silver on or off. Eventually an equilibrium will be reached. For
example, it might be necessary to run the ionization every 4 days out of 7 to maintain the copper
residual at 0.5ppm under current conditions. Silver residual will be 50ppb when copper is 0.5ppm
5.3 Ultraviolet
Lamp life is 10 000? Hours. UV runs when electronic box is powered.
Check UV lamp indicator on face of electronic box for operation. Replace after 10 000 hours of
operation.
SECTION 6: MAINTENANCE
_________________________________________________
6.1 General maintenance
It is extremely important to maintain a pH in the range of 6.8-7.2. This allows for most effective
operation of eClear's natural fresh water oxidation process.
It is extremely important to maintain a copper residual of 0.5ppm. This will ensure the cleanest,
safest pool water.
It is extremely important to maintain clean filter glass media for maximum filtration of all solid matter.
This is done by regularly backwashing and rinsing the filter and by changing or rejuvenating the filter
glass media annually.
Calcium hardness may need to be checked annually, especially in pool's that are topped up with new
water regularly. Ensure that this is carried out by a professional.
6.2 Electrode cleaning

"
15"
Both the oxygen and copper plates may, from time to time become caked with dirt. This will impede
proper performance of the e-clear system. It is therefore necessary to clean the plates or to have
them cleaned by a certified e-clear technician.
Method for cleaning plates:
•Switch off the pool pump and e-clear unit
•Undo nuts at plates to remove electrode cables
•Unscrew unions at each end of the copper chamber and at each end of the oxygen chamber.
•Dilute one part pool acid (hydrochloric acid) to five parts water, in a bucket. About a 20cm deep
solution.
•Immerse each chamber in the acid solution for about 5 minutes or until build-up has dissolved.
•Immediately rinse in clean water to remove acid residue.
•Replace both chambers inline so that water in circulation will flow through the oxygen chamber first
then the copper chamber.
•Replace electrode cables (white to oxygen plated)
6.3 Electrode replacement
Replacement of copper plates and silver electrodes is, preferably to be done by an e-clear certified
Technician.
Method to replace copper plates:
•Switch off pool pump and e-clear system
•Undo nuts at plates to remove electrode cables
•Unscrew unions at each end of copper chamber
•Remove copper/silver chamber
•Undo holding nuts (these may be re-used if o-rings intact)
•Slide out old copper plates, slide in new copper plates so that the plate lug sits over the hole in the
PVC. Screw in bolts tightly. Same process with silver
•Replace chamber and tighten unions
•If leaks occur at bolt o-rings, tighten slightly
•Replace electrode cables.
It is not necessary to change oxygen plates as they are not sacrificial.
6.4 UV lamp replacement
It is preferable for this to be carried out by a qualified electrician or e-clear Technician. Switch off
pool pump and unit
Carefully remove endcaps form UV chamber (be careful to not pull on wires.) Undo electrical wires
from 'chocolate blocks' using a screwdriver Carefully unscrew grey threaded bush, making sure to
retain o-rings. Slide out UV lamp from chamber.
Reconnect old chocolate block to new UV lamp and carefully slide new lamp into UV chamber.
Screw back grey threaded bushes making sure o-rings are re-seated. Re-attach electrical connections
as before
Switch on pool pump only NOT E-CLEAR UNIT, and check for leaks.
Return endcaps
Dispose of UV lamp in accord with government regulations.

16"
6.5 Repair/ Spares service
All local and international repairs contact:
E-clear Technologies South Africa
Phone: Jason +27 76 611 7803
Office: +27 21 854 6356
Fax: +27 21 854 6117
Email: jason@eclearsa.com
Mail: PO Box 2308
Somerset West
7129
South Africa
Download our new E-clear App to your smartphone/tablet
Available on the Available on the Android
App Store App Store

"
17"
SECTION 7:CERTIFICATION AND LIMITED WARRANTY
_________________________________________________
7.1 Patent
Patent number- 2003/2934
7.2 Limited Warranty
E-clear Technologies warrants its products to the original purchaser against any defects that are due
to faulty material or workmanship for a period of one year from date of shipment unless otherwise
noted in the product manual.
In the event that a defect is discovered during the warranty period E-clear agrees that, at its option,
it will repair or replace the defective product or refund the purchase price excluding original shipping
and handling charges.
Any product repaired or replaced under this warranty will be warranted, only for the remainder of the
original product warranty.
This warranty does not apply to consumable products such as lamps or Copper Electrodes.
Contact E-clear or your distributor to initiate warranty.
Products may not be returned without authorization from E-clear Tech.
Limitations:
This warranty does not cover:
Damage caused by natural disasters, labour unrest, acts of war (declared or undeclared), terrorism,
civil strife, or acts of any governmental jurisdiction.
Damage caused by misuse, neglect, accident or improper application or installation. Damage caused
by any repair or attempted repair not authorized by eClear Technologies Any product not used in
accordance with the instructions furnished by eClear.
Freight charges to return merchandise to eClear
Freight charges on expedited or express shipment or warranted parts or products
Travel fees associated with on-site warranty repair
This warranty contains the sole express warranty made by eClear Tech.
In connection with its products. All implied warranties, including without limitation, the warranties of
merchantability and fitness for a particular purpose, are expressly disclaimed.
This warranty constitutes the final, complete and exclusive statement of warranty terms and no
person is authorized to make any other warranties or representations on behalf of eClear
Technologies.
Limitations of Remedies
The remedies of repair, replacement or refund of purchase price as stated above are the exclusive
remedies for breach of this warranty. On the basis
Of strict liability or under any other legal theory, in no event shall E-clear Technologies be liable for
any incidental or consequential damages of any kind for breach of warranty or negligence.

"
18"
"
SECTION 8:
_________________________________________________
" "
INSTALLATION AND MAINTANCE
GUIDE FOR E-CLEAR POOLS
This manual suits for next models
11
Table of contents
Popular Lighting Equipment manuals by other brands

Georg Bechter Licht
Georg Bechter Licht System Dot 28 installation instructions

Safavieh
Safavieh TBL4182A quick start guide

Selecon
Selecon Pacific 19PACLMCOV installation guide

DOTLUX
DOTLUX HIGHFORCEabs 4776-040120 user manual

Triton Blue
Triton Blue TR-3256-250 user manual

LED-POL
LED-POL ORO-URAN-12W-DW Installation instruction

Hubbell
Hubbell Kim Lighting Lightvault LTV59 installation instructions

Leviton
Leviton JCC JC17065 installation instructions

Snowfall
Snowfall SD1000MM installation manual

Clark-Reliance
Clark-Reliance Jacoby-Tarbox Phaeton Series Installation, Operating and Maintenance Instruction

Robe
Robe Anolis Ambiane XP56 user manual

Aputure
Aputure amaran 150c product manual