E2S BExBG05D-P User manual

INSTRUCTION MANUAL
BExBG05D-P
Xenon Beacon
ATEx/IECEx & UKEx Gas & Dust
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D210-00-201-IS Issue 5 12-09-2022 Sheet 1 of 6
BExBG05D-P
1. Product Table
Unit Type Code Nominal
Input Voltage
Nominal
Input Current Max I/P Voltage
BExBG05DPDC012 12Vdc 750mA 14V
BExBG05DPDC024 24Vdc 300mA 28V
BExBG05DPDC048 48Vdc 180mA 54V
BExBG05DPAC115 115Vac 140mA 126V
BExBG05DPAC230 230Vac 55mA 253V
It is important that a suitable power supply is used to run the equipment. The power supply selected must have the necessary capacity
to provide the input current to all of the units.
The above table shows the input current taken by the various beacons and shows the maximum voltage at which the beacons can be
operated:
The input current will vary according to the voltage input level.
2. Warnings
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
DO NOT OPEN WHEN ENERGIZED
POTENTIAL ELECTROSTATIC CHARGING HAZARD – CLEAN ONLY WITH A DAMP CLOTH
COVER BOLTS CLASS A4-80
USE HEAT RESISTING CABLES AND CABLE GLANDS (RATED 110°C) AT AMB. TEMPERATURES OVER
40°C

European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D210-00-201-IS Issue 5 12-09-2022 Sheet 2 of 6
3. Marking & Rating Information
The BExBG05D-P comply with the following standards for hazardous
locations:
3.1 ATEX / IECEx & UKEx Ratings
Standards
EN60079-0:2018/IEC60079-0:2017 (ed.7): Explosive
Atmospheres - Equipment General Requirements.
EN60079-1:2014/IEC60079-1:2014 (ed.7): Explosive
Atmospheres - Equipment Protection by Flameproof Enclosures
“d”.
EN60079-31:2014/IEC60079-31:2013 (ed.2): Explosive
Atmospheres - Equipment Dust Ignition Protection by enclosure
“t”.
Model No: Rating
BExBG05D-P Ex db IIC T5 Gb Ta. -50°C to +40°C
Ex db IIB T4 Gb Ta. -50°C to +70°C
Ex tb IIIC T93°C Db Ta. -50°C to +40°C
Ex tb IIIC T108°C Db Ta. -50°C to +55°C
Ex tb IIIC T123°C Db Ta. -50°C to +70°C
See Product table for electrical ratings of each unit model
Certificate No. KEMA 00ATEX2006X
IECEx KEM 10.0002X
UL22UKEX2636X
Epsilon x
Equipment Group
and Category:
II 2G
II 2D
CE Marking and
Notified Body No. 2813
UKCA Marking and
Approval Body No.
0518
4. Zones, Gas Group, Category and
Temperature Classification
The units can be installed in locations with the following conditions:
A
rea Classification Gas
Zone 1 Explosive gas air mixture likely to occur in normal
operation.
Zone 2
Explosive gas air mixture not likely to occur in
normal operation, and if it does, it will only exist for
a short time.
Gas Groupings
Group IIA Propane
Group IIB Ethylene
Group IIC Hydrogen and Acetylene (up to 55°C ambient)
Temperature Classification for Gas Applications
T1 450
o
C
T2 300
o
C
T3 200
o
C
T4 135
o
C
T5 100° C (Ambient +40°C)
A
rea Classification Dust
Zone 21 Explosive dust air mixture likely to occur in normal
operation.
Zone 22
Explosive dust air mixture not likely to occur in
normal operation, and if it does, it will only exist for
a short time.
Dust Groupings
Group IIIA Combustible Dusts
Group IIIB Non-Conductive Dusts
Group IIIC Conductive Dusts
E
q
ui
p
ment Cate
g
or
y
2G, 2D
E
q
ui
p
ment Protection Level
Gb, Db,
Maximum Surface Tem
p
erature for Dust A
pp
lications
93°C at +40°C
108°C at +55°C
123°C at +70°C
A
mbient Temperature Range
-50°C to +70°C Gas Groups IIA, IIB and IIC
-50°C to +70°C Dust Grou
p
s IIIA, IIIB and IIIC
IP Rating
IP66/67 to EN/IEC60529 and
IP6X to EN/IEC60079-0, EN/IEC60079-31
The beacon must only be installed by suitably qualified personnel in
accordance with the latest issues of the relevant standards:
EN60079-14 / IEC60079-14: Explosive atmospheres - Electrical
installations design, selection and erection
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres -
Classification of areas. Explosive gas atmospheres
EN60079-10-2 / IEC60079-10-2: Explosive atmospheres -
Classification of areas. Explosive dust atmospheres
The installation of the beacon must also be in accordance with any local
codes that may apply and should only be carried out by a competent
electrical engineer who has the necessary training.

European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D210-00-201-IS Issue 5 12-09-2022 Sheet 3 of 6
5. Special Conditions for Safe Use
Repair of the flamepath / flameproof joints is not permitted.
The enclosure is non-conducting and may generate an
ignition-capable level of electrostatic charges under certain
extreme conditions (such as high-pressure steam). The user
should ensure that the equipment is not installed in a location
where it may be subjected to external conditions that might
cause a build-up of electrostatic charges on non-conducting
surfaces.
Additionally, cleaning of the equipment should be done only
with a damp cloth.
6. Product Mounting and Access
The location of the beacon should be made with due regard to
the area over which the warning signal must be visible. They
should only be fixed to services that can carry the weight of the
unit.
The BEx beacon should be secured to any flat surface using
at least two of the three 7mm fixing holes on the stainless steel
U shaped mounting bracket. See Figure 1. The required angle
can be achieved by loosening the two large bracket screws in
the side of the unit, which allow adjustment of the beacon in
steps of 18°. On completion of the installation then two large
bracket adjustment screws on the side of the unit must be fully
tightened to ensure that the unit cannot move in service.
This equipment has no restrictions on mounting orientation.
145,0
30,0
30,0
126,8
229,2
137,00
Fig. 1 Fixing Location for Beacon
7. Access to the Flameproof Enclosure
To access the Ex d chamber, remove the four M6 hexagon
socket head screws and withdraw the flameproof cover taking
extreme care not to damage the flameproof joints in the
process. M6 cover screws are Class A4-80 stainless steel and
only screws of this category can be used for the enclosure.
Fig. 2 Accessing the Explosion proof Enclosure.
On completion of the installation, the flameproof joints should
be inspected to ensure that they are clean and that they have
not been damaged during installation.
On completion of the installation, the flameproof joints should
be inspected to ensure that they are clean and that they have
not been damaged during installation.
Check that the earth bonding wire between the two castings is
secure and the ‘O’ ring seal is in place. When replacing the
flameproof cover casting ensure that it is square with the
flameproof chamber casting before inserting. Carefully push
the cover in place allowing time for the air to be expelled. Only
after the cover is fully in place should the four M6 Stainless
Steel A4-80 cover bolts and their spring washer be inserted
and tightened down. If the cover jams while it is being inserted,
carefully remove it and try again. Never use the cover bolts to
force the cover into position.
Warning – High voltage may be present,
risk of electric shock. DO NOT open when
energised, disconnect power before
opening.
Warning – Hot surfaces. External surfaces
and internal components may be hot after
operation, take care when handling the
equipment.
(Appropriate cable glands
to be customer su
pp
lied
)
Flameproof cover
M6 Cover
Screws
M6 Spring
Washer

European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D210-00-201-IS Issue 5 12-09-2022 Sheet 4 of 6
8. Selection of Cable. Cable Glands, Blanking
Elements & Adapters
When selecting the cable size, consideration must be given to
the input current that each unit draws (see table above), the
number of beacons on the line and the length of the cable runs.
The cable size selected must have the necessary capacity to
provide the input current to all of the beacons connected to the
line.
For ambient temperatures over +40ºC the cable entry
temperature may exceed +70ºC and therefore suitable heat
resisting cables and cable glands must be used, with a rated
service temperature of at least 110ºC
The dual cable gland entries have an M20 x 1.5 entry thread.
To maintain the ingress protection rating and mode of
protection, the cable entries must be fitted with suitably rated
ATEX / IECEx or UKEx certified cable glands and/or suitably
rated ATEX / IECEx or UKEx certified blanking devices during
installation according to EN / IEC60079-14.
If a high IP (Ingress Protection) rating is required then a
suitable sealing washer must be fitted under the cable glands
or blanking plugs.
For use in explosive dust atmospheres, a minimum ingress
protection rating of IP6X must be maintained.
The BEx beacon range can be supplied with the following
types of adapters:
M20 to ½” NPT
M20 to ¾” NPT
M20 to M25
It is important to note that stopping plugs cannot be fitted onto
adapters, only directly onto the M20 entries.
Any other adapters used must be suitably rated and ATEX /
IECEx or UKEx certified adapters.
9. Earthing
Both AC and DC beacon units must be connected to an earth.
The units are provided with internal and external earth
terminals which are both located on the terminal chamber
section of the unit.
Fig. 3 Internal View of Cover
When using the internal earth terminal ensure that the
stainless steel M4 flat washer is between the incoming earth
wire and the enclosure.
Internal earthing connections should be made to the Internal
Earth terminal in the base of the housing using a ring crimp
terminal to secure the earth conductor under the earth clamp.
The earth conductor should be at least equal in size and rating
to the incoming power conductors. Tighten M4 Earth screw to
1Nm.
External earthing connections should be made to the M5 earth
stud, using a ring crimp terminal to secure the earth conductor
to the earth stud. The external earth conductor should be at
least 4mm² in size. Tighten the Earth nut to 3Nm. Please firmly
tighten the external grounding terminal so that the stud does
not become loose and lay the ground wire so that it is not
caught by twisting and sagging.
10. Cable Connections
Electrical connections are to be made into the terminal blocks
on the PCBA located in the flameproof enclosure. See section
7 of this manual for access to the flameproof enclosure.
Wires having a cross sectional area between 0.5 mm² to
2.5mm² can be connected to each terminal way. If an input and
output wire is required the 2-off Live/Neutral or +/- terminals
can be used. If fitting 2-off wires to one terminal way the sum
of the 2-off wires must be a maximum cross sectional area of
2.5mm². Strip wires to 8mm. Wires may also be fitted using
ferrules. Terminal screws need to be tightened down with a
tightening torque of 0.45 Nm / 5 Lb-in. When connecting wires
to the terminals great care should be taken to dress the wires
so that when the cover is inserted into the chamber the wires
do not exert excess pressure on the terminal blocks. This is
particularly important when using cables with large cross
sectional areas such as 2.5mm².
External Earthing
Internal
Earthing
Internal
Bonding
Wire
Terminal
2-off M20
Cable
Entries

European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D210-00-201-IS Issue 5 12-09-2022 Sheet 5 of 6
11. AC Wiring
A 4-way terminal block is provided on the AC beacon. There
are 2-off Live and 2-off Neutral terminals in total.
11.1 Wiring Diagram
Fig. 4 AC Terminals
12. DC Wiring
A 4-way terminal block is provided on the AC beacon. There
are 2-off +ve, 2-off –ve, 1-off stage 2 & stage 3 terminals in
total.
12.1 Wiring Diagram
Fig. 5 DC Terminals
12.2 Line Monitoring
On BExBG05D-P DC units, dc reverse line monitoring can be
used if required. All DC beacons have a blocking diode fitted
in their supply input lines. An end of line monitoring diode or
an end of line monitoring resistor can be connected across the
+ve and –ve terminals. If an end of line resistor is used it must
have a minimum resistance value of 3k3Ω and a minimum
power rating of 0.5 watts or a minimum resistance value of
500Ω and a minimum power rating of 2 watts.
The resistor must be connected directly across the +ve and -
ve terminals as shown in the following drawing. The resistor
leads should be kept as short as possible.
Fig. 6 End of Line Resistor Placement
13. Settings
13.1 Synchronised Operation
All BExBG05D-P beacons that are connected to the same
supply line will have a synchronised flash rate at one flash
every second. To ensure that the units will be synchronised
check that the pin header is not fitted, i.e. the two header pins
are not shorted together (see Figure 7).
Fig. 7 Header Pin Settings
13.2 Flip-Flop Operation
Two beacons can be mounted close to each other to form a
flip-flop operation, where the beacons will flash alternately. To
achieve this mode of operation, fit a pin header to the flip- flop
header pins on the electronics board, i.e. the two header pins
are shorted together, (see figure 7) on one of the two beacons.
The first flash on the beacon that has the header fitted will be
delayed by ½ second. The two beacons will then flash
alternately every ½ a second.
Shorted
together
Not
shorted
together
End of Line Resisto
r
L L N N
--
++

European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D210-00-201-IS Issue 5 12-09-2022 Sheet 6 of 6
14. Interchangeable & Spare Parts
The beacon cover is interchangeable, contact E2S Ltd for a
replacement cover available in various colours.
To change the cover, unscrew the M5 socket head screws and
remove the M5 screws, M5 spring & flat washers.
Fig. 8 Removal of cover
Remove the guard and replace the old cover with the new
cover.
Fig. 9 Changing of cover
Fit the guard back on to the cover and casting, align the holes
of the guard, cover and casting. To reattach the cover, the
fixings MUST be in the order shown in figure 10.
Fig. 10 Cover and Guard Fixtures
15. Maintenance, Overhaul & Repair
Maintenance, repair and overhaul of the equipment should
only be carried out by suitably qualified personnel in
accordance with the current relevant standards:
EN60079-19
IEC60079-19
Explosive atmospheres - Equipment
repair, overhaul and reclamation
EN 60079-17
IEC60079-17
Explosive atmospheres - Electrical
installations inspection and maintenance
The acoustic horn is made out of ABS plastic, therefore to
avoid a possible ELECTROSTACTIC CHARGE the unit must
only be cleaned with a damp cloth.
Units must not be opened while an explosive atmosphere is
present.
If opening the unit during maintenance operations a clean
environment must be maintained and any dust layer removed
prior to opening the unit.
Warning – Hot surfaces. External surfaces
and internal components may be hot after
operation, take care when handling the
equipment.
M5x16 Hex Socket Screw
M5 Spring Washer
M5 Plain Washer
Guard
Cover
M5x16 Hex
Socket Screw
Old
Cover
New

warning signals
2S
BEx
EUROPEAN SAFETY SYSTEMS LTD
IMPRESS HOUSE
MANSELL ROAD
ACTON
LONDON W3 7QH
WWW.E2S.COM
C
THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE
MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND
IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY
SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY
BE DISCLOSED, LOANED, COPIED OR USED FOR
MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR
WRITTEN CONSENT.
EUROPEAN SAFETY SYSTEMS LTD.
AS PER LATEST DATE OF ISSUE SHOWN ABOVE
DRAWING TO BS8888:2000
GEOMETRIC TOLERANCES TO ISO1101:1983
LINEAR DIMENSIONAL TOLS
ANGULAR DIMENSIONAL TOLS
STANDARDS
MOD No. REASON - INITIAL - DATEISSUE
DATE
APPROVED
CHECKED DATE
DATE
DRAWN WEIGHT (Kg)
SURFACE FINISH
MATERIAL
ALTERNATIVE MATERIAL SHEETSCALE
TITLE
A3
IF IN DOUBT, ASK -
DO NOT SCALE
ALL DIMENSIONS IN MM
DRAWING NUMBER
A
B
C
D
E
F
G
109
G
F
E
78
6
5
D
C
134
2
A
B
D210-06-201
R.S.RAIT
B.ISARD
R.N.POTTS OF
NTS 1 1
OPTIONAL LINE MONITORING RESISTOR, CUSTOMER SUPPLIED,
500Ω MIN, 2W MIN OR 3K3Ω MIN, 0.5W MIN
MINIMUM VALUES:
R1
Single Stage Configuration Config.: 1
Optional Line Monitoring
Negative switching
Stage 1: Apply Power to +ve & -ve
24/03/2022
24/03/2022
24/03/2022
BExBG05D, BExBG10D, BExBG15D DC
BEACON WIRING DIAGRAM
INTRODUCTIONINTRODUCTION
1RSR - 24/03/2022
-ve
in
R1
-ve
out
+ve
in
+ve
out

warning signals
2S
BEx
EUROPEAN SAFETY SYSTEMS LTD
IMPRESS HOUSE
MANSELL ROAD
ACTON
LONDON W3 7QH
WWW.E2S.COM
C
THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE
MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND
IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY
SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY
BE DISCLOSED, LOANED, COPIED OR USED FOR
MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR
WRITTEN CONSENT.
EUROPEAN SAFETY SYSTEMS LTD.
AS PER LATEST DATE OF ISSUE SHOWN ABOVE
DRAWING TO BS8888:2000
GEOMETRIC TOLERANCES TO ISO1101:1983
LINEAR DIMENSIONAL TOLS
ANGULAR DIMENSIONAL TOLS
STANDARDS
MOD No. REASON - INITIAL - DATEISSUE
DATE
APPROVED
CHECKED DATE
DATE
DRAWN WEIGHT (Kg)
SURFACE FINISH
MATERIAL
ALTERNATIVE MATERIAL SHEETSCALE
TITLE
A3
IF IN DOUBT, ASK -
DO NOT SCALE
ALL DIMENSIONS IN MM
DRAWING NUMBER
A
B
C
D
E
F
G
109
G
F
E
78
6
5
D
C
134
2
A
B
D210-06-205
R.S.RAIT
B.ISARD
R.N.POTTS OF
NTS 1 1
Single Stage Configuration Config.: 1
Stage 1: Apply Power to Live & Neutral
24/03/2022
24/03/2022
24/03/2022
BExBG05D, BExBG10D, BExBG15D & BxBG21D
AC BEACON WIRING DIAGRAM
INTRODUCTIONINTRODUCTION
1RSR - 24/03/2022
Live
in out
Neutral
in out

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: s[email protected] www.e2s.com DC-004_Issue_N (BExBG) - Page 1 of 2 - QAF_252_Issue_5
EU Declaration of Conformity
Manufacturer: European Safety Systems Ltd.
Impress House, Mansell Road, Acton
London, W3 7QH
United Kingdom
Authorised Representative: E2S Warnsignaltechnik UG
Charlottenstrasse 45-51
72764 Reutlingen
Germany
Equipment Type: Electronic Beacons
Types BExBG05D(-P)(-SIL), BExBG10D(-P)(-SIL), BExBG15D(-P)(-SIL), BExBG21D(-P),
BExTBG05D(-P), BExBGL2D(-P), BExBG05E(-P), BExBG10E(-P) and BExBG15E(-P)
Directive 2014/34/EU: Equipment and Protective Systems for use in Potentially Explosive Atmospheres (ATEX)
Notified Body for EU type Examination (Module B):
Dekra Certification B.V.
Notified Body No.: 0344
Meander 1051, 6825 MJ Arnhem, The Netherlands
EU-type Examination Certificate (Module B):
KEMA 00ATEX2006X
Notified Body for Quality Assurance Notification / Conformity to EU-type
based on
quality assurance of the production process (Module D):
Sira Certification Service
Notified Body No.: 2813
CSA Group Netherlands B.V, Utrechtseweg 310, 6812 AR, Arnhem, Netherlands
Quality Assurance Notification (Module D):
SIRA 05 ATEX M342
Provisions fulfilled by the equipment:
I 2G Ex db IIC T6...T3 Gb
II 2G Ex db eb IIC T5...T4 Gb
II 2D Ex tb IIIC T60 ºC...T200 ºC Db
Standards applied:
EN IEC 60079-0 : 2018
EN 60079-1 : 2014
EN 60079-7 : 2015 + A1 : 2018
EN 60079-31 : 2014
Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)
Standards applied:
EN 61000-6-1:2007
EN 61000-6-2:2005
EN 61000-6-3:2007 / A1:2011 / AC: 2012
EN 61000-6-4:2007 / A1: 2011
Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic
equipment, including amendment by Directive 2015/863/EU.
Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
The product and all the components contained within it are free from substances of very high concern.
Other Standards and Regulations
EN 60529:1991 + A1:2000 + A2:2013. - Degrees of protection provided by enclosures (IP code) –enclosure rated IP66/67

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: s[email protected] www.e2s.com DC-004_Issue_N (BExBG) - Page 2 of 2 - QAF_252_Issue_5
Martin Streetz
Document No.:
DC-004_Issue_N
Quality Assurance Manager
Date and Place of Issue:
London, 20/04/2022
EU Declaration of Conformity
On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment
conforms with all technical and regulatory requirements of the above listed directives, regulations and standards.
This Declaration is issued under the sole responsibility of the manufacturer.

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sale[email protected] www.e2s.com DC-105_Issue_A (BExBG)- Page 1 of 2 - QAF_252_Issue_5
UKCA
Declaration of Conformity
Manufacturer: European Safety Systems Ltd.
Impress House, Mansell Road, Acton
London, W3 7QH
United Kingdom
Equipment Type: Electronic Beacons
Types BExBG05D(-P)(-SIL), BExBG10D(-P)(-SIL), BExBG15D(-P)(-SIL), BExBG21D(-P),
BExTBG05D(-P), BExBGL2D(-P), BExBG05E(-P), BExBG10E(-P) and BExBG15E(-P)
Directive UKSI 2016:1107 (as amended by UKSI 2019:696) – Schedule 3A, Part 1 : Product or Protective System Intended for use in Potentially Explosive Atmospheres
(UKCA)
Notified Body for UK type Examination (Module B):
UL International (UK) Ltd
Notified Body No.: 0843
Unit 1-3 Horizon Kingsland Business Park, Wade Road,
Basingstoke, Hampshire RG24 8AH UK
UK-type Examination Certificate (Module B):
UL21UKEX2636X
Notified Body for Quality Assurance Notification / Conformity to EU-type
based on
quality assurance of the production process (Module D):
Sira Certification Service
Notified Body No.: 0518
Rake Lane, Eccleston, Chester CH4 9JN, UK
Quality Assurance Notification (Module D):
CSAE 22UKQAN0046
Provisions fulfilled by the equipment:
II 2G Ex db IIC T6…T3 Gb
II 2G Ex db eb IIC T5…T4 Gb
II 2D Ex tb IIIC T60°C…T200° Db
IP6X Dust Protection to EN60079-0 / EN60079-31
Standards applied:
EN IEC 60079-0: 2018
EN 60079-1: 2014
EN IEC 60079-7: 2015 + A1: 2018
EN 60079-31: 2014
Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)
Standards applied:
EN 61000-6-1:2007
EN 61000-6-2:2005
EN 61000-6-3:2007 / A1:2011 / AC: 2012
EN 61000-6-4:2007 / A1: 2011
Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic
equipment, including amendment by Directive 2015/863/EU.
Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
The product and all the components contained within it are free from substances of very high concern.
Other Standards and Regulations
EN 60529:1991 / A1:2000 / A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sale[email protected] www.e2s.com DC-105_Issue_A (BExBG) - Page 2 of 2 - QAF_252_Issue_5
Martin Streetz
Document No.:
DC-105_Issue_A
Quality Assurance Manager
Date and Place of Issue:
London, 12/09/2022
UKCA
Declaration of Conformity
On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment
conforms with all technical and regulatory requirements of the above listed directives, regulations and standards.
This Declaration is issued under the sole responsibility of the manufacturer.
This manual suits for next models
5
Table of contents