7.6 Start the unit after a long period out of
service
Start-up the unit after out of service for a long period (includes
drive up a unit at the first time), you would see rust mix up water
in red, flow out from tap. Such that is a normal circumstance,
please be calmly and keep draining, after for a while rust will
disappear.
7.7 About power failure
In case power failure during the unit working, please stop all
operating actions.
At the next startup after power failure, the RUN indicator of
controller will blink slowly for several seconds for noting user.
Misoperation occur during unit working:
In case misoperation caused by lighting or vehicle radio, cut off
the manual power switch, and turn it on again, afterward press
RUN/STOP key.
It is forbidden to switch the power off if ambient temperature
below -7ć. In case of power failure or power need be cut
because of maintenance, please open the drainage valves at the
joints of water inlet and outlet pipes as soon as possible to
draining out all water. Otherwise, components inside of the units
may be damaged by freeze. Upon draining water, please close
the water drainage valves.
7.8 About RCCB
Outdoor unit must use RCCB,pleases install an RCCB between
in user power supply and the outdoor unit. In case the unit
cannot act but not attribute to power failure, please check these
RCCB switches at first. Before operate the RCCB, please
ensure that the user installing switch is break off.
After the RCCB has serviced for a period of time (Generally once
a month), it is necessary to press the test button at close circuit
to check whether the performance of RCCB is work normally
(Every time you press this button, RCCB would break-off once at
a time). In case malfunction occurs, but no causes were found, it
is permit to delivering power to RCCB to detect failure. If RCCB
did not work when being power, you must check out the cause by
feature test if necessary. If which detected and confirmed as its
self-malfunction, please consigning a professional personnel to
replace a new one or repair it immediately.
7.9 About shut-off memory
Every time when power is shut off, controller will save the current
operate status automatically. when power come on the next time,
controller would deliver ON/OFF signal to the unit according to its
memory before power failure. This function keeps unit always
working on the mode which was set in the last time before power
failure.
7.10 About upkeep and maintenance
Before leave the unit idle for a long period, please make sure the
followings:
Vacuum air completely inside the heat exchanger and water at
pipelines, and turn off all valves.
Check and clean the internal components of the unit at a regular
base
After leave the unit idle for a long period, please check the follow-
ings:
Inspect the air intake orifice or air outlet is blocked periodically. If
any, remove the foreign substance to let the air flow fluently.
Check whether pipes, valves have damaged or blocked, whether
connection sites have leakaged. If that so, please fix it.
7.11 About heating capacity
The heating process is a heat-pump mode that it absorbs heat
from outdoor and release to water, Once the outdoor tempera-
ture decrease the heating capacity will also decrease simultane-
ity.
Voltage
Prior to any operation, check that the voltage on the name plate
of the appliance corresponds to the mains voltage provided on
site.
7.12 Capacity and energy efficiency curve