MicroWedge MW12 Specifications group · S
INPUT PANEL
NOTES
TABULARDATA
1. Measurement/DataProcessing Systems: Primary -FChart:proprietary EAW software; Secondary- Brüel & Kjær2012.
2. MicrophoneSystems: EarthworksM30; Brüel&Kjær 4133
3. Measurements: Dualchannel FFT;length:32768 samples;samplerate: 48kHz;logarithmic sine wavesweep.
4. MeasurementSystem Qualification (includesalluncertainties):SPL: accuracy+/-0.2dB @1kHz, precision +/-0.5dB 20 Hzto20 kHz,resolution0.05 dB;Frequency:accuracy +/-1%,
precision+/-0.1Hz,resolution the largerof1.5Hz or 1/48octave;Time:accuracy +/-10.4 µs,precision+/-0.5µs, resolution 10.4µs;Angular:accuracy+/-1°,precision+/-0.5°,resolution0.5°.
5. Environment: Measurementstime-windowedandprocessed to eliminateroomeffects,approximatingananechoic environment. Dataprocessedasanechoic or fractionalspace,asnoted.
6. MeasurementDistance: 7.46m.Acousticresponsesrepresentcomplexsummationofthesubsystems at20m.SPLisreferencedtootherdistancesusingtheInverseSquareLaw.
7. EnclosureOrientation: For beamwidthandpolar specifications,asshown inMechanicalSpecification drawing.
8. Volts: Measuredrmsvalueof thetestsignal.
9. Watts: Peraudioindustrypractice,“loudspeaker watts”arecalculated as voltagesquared divided byrated nominal impedance. Thus,these are notTrue Wattunitsof energyasdefined
byInternationalStandard.
10. SPL: (SoundPressure Level) Equivalenttothe averagelevelof asignalreferenced to0dB SPL=20 microPascals.
11.Subsystem: This lists thetransducer(s)and theiracousticloading foreachpassband. Sub=Subwoofer,LF=LowFrequency,MF =MidFrequency,HF =HighFrequency.
12.Operating Mode: User selectable configurations.Betweensystemelements,acomma(,)=separateamplifier channels; a slash(/)=singleamplifierchannel.DSP=DigitalSignalProcessor.
IMPORTANT:To achieve thespecified performance, thelistedexternal signalprocessingmust beusedwith EAW-providedsettings.
13.Operating Range: Range wheretheprocessed FrequencyResponsestays within-10dB SPLofthe poweraveragedSPLwithinthis range; measuredon the geometricaxis.Narrow band
dipsareexcepted.
14.Nominal Beamwidth: Design angleforthe -6dBSPLpoints,referenced to 0dBSPLasthe highest level.
15.AxialSensitivity: PoweraveragedSPLovertheOperating Rangewithan inputvoltagethat wouldproduce1 Watthe nominal impedance;measured with noexternalprocessing onthe
geometricaxis,referenced to1m.
16.Nominal Impedance: Selected 4,8,or 16ohmresistance suchthatthe minimum impedancepoint is nomore than 20%belowthis resistanceoverthe OperatingRange.
17.AcceleratedLifeTest: Maximumtestinput voltage appliedwith an EIA-426Bdefined spectrum; measuredwithrecommended signalprocessingand RecommendedProtectionFilter.
18.CalculatedAxialOutput Limit: Highest averageandpeak SPLs possibleduring theAcceleratedLifeTest. The Peak SPLrepresentsthe2:1(6 dB)crestfactor of theLifeTest signal.
19.High Pass Filter: Thishelpsprotect theloudspeakerfrom excessiveinputsignal levelsatfrequencies below theOperating Range.
GRAPHICDATA
1.Resolution:To removeinsignificantfine details,1/12octave cepstral smoothingwas applied toacousticfrequency responsesand1/3 octavecepstralsmoothing wasappliedto the
beamwidth andimpedancedata. Other graphsareplotted using rawdata.
2.Frequency Responses: Variationinacousticoutputlevelwithfrequencyforaconstantinputsignal. Processed: normalized to0dBSPL.Unprocessedinputs:2V(4ohm nominal impedance),
2.83V(8 ohmnominalimpedance), or4V (16ohmnominal impedance) referencedto a distanceof1 m.
3.Processor Response: The variationinoutput levelwithfrequency for aconstant input signalof0.775 V=0 dBreference.
4.Beamwidth:Averageangle foreach1/3 octavefrequencyband where,startingfrom therearof the loudspeaker,the output firstreaches -6 dBSPLreferencedto0 dBSPLasthehighest
level.Thismethodmeans theoutputmay dropbelow-6 dB SPLwithinthebeamwidthangle.
5.Impedance: Variationin impedancemagnitude,in ohms,withfrequency withoutregardto voltage/currentphase.Thismeans the impedancevalues may not
beusedto calculateTrue Watts(see9 above).
6.Polar Data: Horizontalandvertical polarresponsesfor each1/3octave frequency band100 Hz to16 kHz orOperatingRange.
SIGNAL DIAGRAM
LEGEND
DSP: User-supplied Digital Signal Processor.
HPF: High Pass Filter for crossover or Recommended High Pass Filter.
LPF: Low Pass Filter for crossover.
LF/MF/HF: Low Frequency / Mid Frequency / High Frequency.
AMP: User-supplied PowerAmplifier.
XVR: Passive LPFs, HPFs, and EQ integral to the loudspeaker.
EasternAcoustic Works One Main Street Whitinsville, MA01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: 0011736-90 February 2008