EB TECHNOLOGY NOLOGO START-S4XL User manual

START-S4XL
START-S4XL_080915_VXX02_GB www.ebtechnology.it www.nologo.info
• Single phase for 230 Vac 2 motors.
• Universal control unit for 1 or 2 motors swing.
• 4 limit switches, Separate slow down.
Radio-receiver
-1-
-3-
-4-
-5-
-6-
-7-
-8-
-12-
-13-
-14-
-15-
-16-
-17-
-18-
-19-
-20-
-21-
230 Vac
230 Vac
230 Vac Signal light
230 Vac Signal light
Motor 1 COMMON
Motor 1 OPEN
Motor 1 CLOSE
CLS Mot 2
OLS Mot 2
CLS Mot 1
OLS Mot 1
Closing photocell
START
24 Vac
24 Vac / 12Vac elect. lock
12Vac elect. lock
STOP
-26-
-27-
Light / Lamp
Light / Lamp
-28-
-29-
Phototest 24 Vac
12 Vac
Lamp or courtesy light
230Vac
Ground Connection -2-
-9-
-10-
-11-
Motor 2 COMMON
Motor 2 OPEN
Motor 2 CLOSE
MOP
CL
COM
MOP
CL
COM
MOT 1
MOT 2
-22-
-23-
-24-
-25-
PEDESTRIAN
Photocell always working
COMMON contacts
+ Antenna
N.O. N.C.
N.O.
-30-
-31-
+ 24 Vdc
- 24 Vdc
24 V OUT24 V
RXTX
Photocells working
in closing
24 V OUT24 V
RXTX
Photo-beam
activated when
opening and closing.
*
*
*Connect this point to the terminal board no. 28
for the photo-test, otherwise connect it to
the terminal board no. 19

Premises
Thismanualprovidesallthespecicinformationyouneedtofa-
miliarize yourself with and correctly operate your unit. Read it
very carefully when you purchase the instrument and consult it
whenever you have doubts regarding use and before performing
any maintenance operations.
Safety precautions
Usingtheunitimproperlyandperformingrepairsormodications
personally will void the warranty. Nologo declines any respon-
sibility for damages due to inappropriate use of the product and
due to any use other than the use the product was designed for.
Nologo declines any responsibility for consequential damages
except civil liability for the products.
The gate should be conformed to the european law EN 60204-1,
EN 12445, EN 12453.
It is obliged to be conformed to the norms for the automated
closing devices EN 12453, EN 12445, EN 12978 and eventaully
nationa laws.
The adjust of the force of the motor should be measured with a
device according to the values of the norma EN 12453.
Environmental protection
measures
Information regarding the environment for custom-
ers within the European Union. European Directive
EC 2002/96 requires that units bearing this symbol
on the unit and/or on the packaging be disposed of
separatelyfromundierentiatedurbanwastes.
be disposed of with the ormal household wastes. The owner is
responsible for disposing of this product and other electrical and
electronicequipmentthroughspecicwastecollectionfacilities
indicated by the government or local public agencies. Correct
disposal and recycling help prevent any potentially negative
impact on the environment and human health. To receive more
detailed information regarding disposal of your unit, we recom-
mend that you contact the competent public agencies, the waste
collection service or the shop where you purchased the product.
Small legend
OLS Open limit switch
CLS Close limit switch
START Control to drive the gate
PEDESTRIAN in sliding units: control partial opening
Vac Alternate current
Vdc Direct current
NC Normally closed
NO Normally open
Isolated contact Isolated from power supply
START-S4XL Technical manual
-2-
Index
Par. Description Pag.
2 Description of the product 4
2.1 Working features
2.2 Fields of application
2.3 Technical features
3 Premises 5
3.1 Preliminary checks
3.2 Type of electrical wires
3.3 Connections
4 Installation of the control board 6
4.1 Scheme and electrical connections
4.2 Description of the electrical connections 7
4.3 Connection of the network tension 8
4.4 Motor connection
4.5 Connection of the signal light
4.6 Connection of a 24Vdc light
4.7 Connection of Courtesy light 9
4.8 Connection of ANTENNA
4.9 Connection of arrest devices STOP command
4.10 Connection of the LSO and LSC LIMIT SWITCHES
4.11 Connection of the commands START / PEDESTRIAN 10
4.12 Connection of LOCKING
4.13 Power supply of ACCESSORIES
4.14 Connection of the PHOTOCELLS A 11
4.15 Connection of the PHOTOCELLS A with phototest
4.16 Connection of the PHOTOCELLS B 12
4.17 Connection of the PHOTOCELLS B with phototest
4.18 Check of the CONNECTIONS
5 Functions and adjustments 13
5.1 Use of the DIP A
5.2 Setting up with DIP B 14
5.3 Diagram of PEDESTRIAN time and START 15
5.4 Setting up with DIP C
6 Using the remote controls 16
6.1 FULL CANCELLATION of the memory
6.2 Learning of the remote controls
7 Time learning 17
7.1 Time learning: NORMAL WAY
7.2 Time learning: ADVANCED SYSTEM 18
7.3 Time learning PEDESTRIAN WAY 19
7.4 Time learning: pause (fastest way)
7.5 Reset of the memory 20
8 Instruction for TEST
9 LED and adjust of
FORCE, DESPLACEMENT AND SLOWDOWN
21
10 Note 22
11 Declaration of CE conformity 23

START-S4XL Technical manual
-3-
Generic Danger
This is a warning and if it is not
respec it can provoque material
damage!
Equipement under electrical
tension
Installation only from qualied
installers.
Usingtheunitimproperlyandperformingrepairsormodicationspersonallywillvoidthewarranty.Theprodu-
cer declines any responsibility for damages due to inappropriate use of the product and due to any use other
than the use the product was designed for. The producer declines any responsibility for consequential damages
except civil liability for the products.
1.1 Safety precautions
Read carefully the manual
Read carefully the manual before
installing
1.2 Symbols and warning
1.3 Security System
1 Introduction
Itisimportanttoestablishthe“MACHINE“risksandtherequirementsofthenaluser.Inthephotothenal
userwillxthenumberofaccessoriestobeinstalled.Intheschemethecoupleofthephoto-beamsAOPEN
ithasnoeectwhileitinvertscompletelyafterclosing.“FOTOA2”istheserialconnectionofthefotoAorALT
connection. Check the synchronisation of the photo-beams which avoid interferences
We recommend to install a STOP command for the immediatelly stop of the gate. The switch is a normally
closed contact as shown in the par. 4.10.
Sliding gates
Swing gates
FOTO A
FOTO A2

START-S4XL Technical manual
-4-
Slow down
Self learning of working times
Eletrical adjust of the force of the motor
4 functions (apartment block included)
Functions set up throught a dip
Free contact for light indicating the open gate
Radio included which can manage codes rolling
Small dimensions
Pedestrian door (partial opening) with separate command
Electrical lock and selecting reversing stroke
Dip exclusion of all the safety inputs
TEST function compatible with TRANSCEIVER
2.1 Working features
2 Description of the product
The START-S4XL is the ongoing evolution of the START-S4 electronic control unit with a set of compatible
clamps. It was created to suit various needs: both for door gates and sliding gates. The design adopted the
mostadvancedtechniquestoguaranteetheutmostimmunityvs.noises,themaximumoperatingexibilityand
to create a wide choice of available functions.
The START S4XL control board is designed to move gates, overhead garage doors, rolling shutters and
automatic doors. It can be connected to an oleodinamic motor or to an electro-mechanical motor with a single-
phase motor, working on 230 Vac.
2.2 Fields of application
Dimensions 145 x 135 x 50 mm
Weight 500 g
MAX power of single motor 1
750
4
HP
W
A
MAX power of signal light 40 W
MAX absorption with clean contact 2 A
MAX absorption 24 Vac (clamps 18-19) 300 mA
MAX absorption 12 Vac (clamps 19-29) 600 mA
MAX absorption 24 Vdc (clamps 30-31) 100 mA
2.3 Technical features

START-S4XL Technical manual
-5-
3.2 Type of electrical wires
Depending on the installation, the type and number of devices installed, the number of cables needed can vary.
The table below shows the cables needed for a typical installation. The cables used in the installation must be
IEC 60335 compliant
Line of the power supply Cavo 3x1,5 mm2
Cable motor Cavo 4 x 1,5 mm2
Signal light Cavo 2x1,5 mm2
Radio antenna Cavo schermato tipo RG58
Key selector Cavo 3x0,5 o 0,75 mm2
Photo Rx Cavo 4x0,5 o 0,75 mm2
Photo Tx Cavo 2x0,5 o 0,75 mm2
3.3 Connections
To guarantee operator safety and to prevent damaging the components, never make connections or insert
wireless receiver boards while the control unit is powered.
•Powerthecontrolunitthrougha3x1.5mm2cable. If the distance between the control unit and the ground
systemconnection is more than 30 m, a ground plate must be installed in proximity to the control unit.
•Ifthemotorsdonothaveacable,usethe4x1.5mm2cable (open + close + common + ground).
•Inconnectingthepartwithanextremelylowsafetyvoltage,
use cables with a minimum section of 0.5 or 0.75 mm2.
•Useshieldedcablesifthelengthexceeds30mandconnectingthegroundbraidonly
from the side of the control unit.
•Donotconnectthecablesinundergroundcaseseveniftheyarewater-tight.
•Iftheyarenotused,theinputstotheNormallyClosed(NC)contactsmustbejumperedtothecommon.
•Ifthesameinputhasmorethanonecontact(NC),theyareplacedinseries.
•Iftheyarenotused,theinputstotheNormallyOpen(NO)contactsareleftloose.
•Ifthesameinputhasmorethanonecontact(NO),theyaretobeplacedinseries.
•Thecontactsmustbemechanicalandfreeofanypotential
Rememberthatsystemsforautomaticgatesanddoorsmustbeinstalledbyhighlyqualiedtechniciansonly
and in full compliance with current law.
Making the correct choice of installation is essential to ensuring adequate safety and good protection against
atmospheric agents. Remember that the control unit contains powered parts and electronic components which
bytheirverynaturearesensitivetoinltrationsandmoisture.Thecontrolunitissuppliedinacontainerwhich
guarantees an IP55 protection rating if adequately installed. Install the control unit on a permanent surface that
isperfectlyat,adequatelyprotectedagainstimpactsandatleast40cmotheground.Thecablesmustenter
the control unit from the bottom only; we recommend using wire leads and water-tight connections. When using
tubingthatcouldllupwithwaterorifthetubingcomesfromanundergroundwell,thewiresmustentera
rstshuntingboxplacedatthesameheightasthecontrolunitandthen,fromthere,thewiresmustbepassed
into the container holding the control unit, again entering from the bottom. This prevents any evaporation of the
water in the tubing from forming condensation inside the control unit itself.
3.1 Preliminary checks
3 Premises

Thecontrolboardhasseveralmicro-switchesthatactivatevariousfunctionsinordertondsuitablesolutions
for the user and to make the installation more safe.
4 Installation of the control board
4.1 Scheme and electrical connections
Neutral 230Vac
Ground
Phase 230Vac
Lamp 230Vac
Lamp 230Vac
MOT 1 COM
MOT 1 OPEN
MOT 1 CLOSE
MOT 2 COM
MOT 2 OPEN
MOT 2 CLOSE
LSC MOT 2
LSO MOT 2
LSC MOT 1
LSO MOT 1
Photo A only cl.
START
24 Vac
12 Vac lock
STOP
24 Vac lock
PEDESTRIAN
Photo b
Antena +
COMMON
START-S4XL Technical manual
-6-
26 27 28 29 30 31
Esclusion of the inputs
RESET OF THE CONTROL UNIT:
PRESSBUTTON“CODES”AND
“TIME”FOR10SEC CLOSE
CODES
FORCE DESPLACEMENT S.DOWN
OPEN

4.2 Description of the electrical connections
230 Vac Neutral 1230 Vac Power supply 50 Hz NEUTRAL
Ground 2Ground connection
230 Vac Phase 3230 Vac Power supply 50 Hz PHASE
Signal light
4OutputsforLAMP(ashinglightelectroniccard)or230Vac
COURTESY LIGHT, maximum power of the lamp 40 or 100W
5
M 1 Com 6Output for motor connection 1 COMMON pole
M 1 Open 7Output for motor connection 1 pole OPEN
M 1 Close 8Output for motor connection 1 pole CLOSE
M 2 Com 9Output for motor connection 2 COMMON pole
M 2 Open 10 Output for motor connection 1 pole OPEN
M 2 Close 11 Output for motor connection 1 pole CLOSE
LSC M2 12 Input Closing Limit Switches motor no.2
LSO M2 13 Input Opening Limit Switches motor no. 2
LSC M1 14 Input Closing Limit Switches motor no. 1
LSO M1 15 Input Opening Limit Switches motor no. 1
Photocell A 16 Input photocell A; working only by closing (see chapter 2.3)
START 17 Input command bi-stable START
24Vac 18 Output for 24Vac
24Vac / 12Vac 19 Output for electrical lock 12Vac 50Hz 1A
12Vac Serrat. 20 Output for electrical lock 12Vac 50Hz 1A
STOP 21 STOP input
PEDESTRIAN 22 Input for bi-stable function partial opening PEDESTRIAN
Photocell B 23 Input photocell B working in closing and in opening (see chap. 2.3)
Common 1 - 24 Common for all inputs:
services, Security devices, coaxial antenna cable sock.
Antenna + 25 Input for antenna (antenna cable)
Light 26 Contactforlight(forashinglightwithoutelectroniccard)
Light 27 Contactforlight(forashinglightwithoutelectroniccard)
PhotoTEST 28 Output 24Vac TEST (see chapter 6)
12Vac 29 Output 12Vac
24Vdc + 30 Output 24Vdc +
Common 24Vdc - 31 Output 24Vdc - Common for inputs: services and safety
START-S4XL Technical manual
-7-

4.3 Connection of the NETWORK TENSION
Network
230 Vac
230 Vac. The line of power supply towards the control board must
always be protected with an electromagnetic switch or with a 5Afuse
couple.
Adierentialswitchisrecommendedbutnotindispensableifitisalre-
ady present in the installation.
4.5 Connection of the SIGNAL LIGHT
4 5 6 4 5 6 26 27
Signal light complete with
intermittent electronic card
Signal light without
intermittent electronic card
If you are expecting to use the test on the
photocells or for a 24V light, you can’t use this
connection.
4.6 Connection of a 24Vdc light with an open and moving gate
28 29 30 31 20 21 If you are expecting to use the test on the photocells or
for a signal light, you can’t use this connection.
DIP 9 A
ON Fix Light
4.4 Motor connection
67
4
Be particularly careful in not mistaking the Opening pole with the
Closing pole.
In case you have doubts about the correct connections, put ma-
nually, if possible, the gate in the middle position of the course. Be
ready to block the system with the STOP command!
1 2 3
8 9 10 115
MOTOR 2
Common
Open
Close
MOTOR 1
Common
Open
Close
ON
CTS
2
143 6
587 10
9
START-S4XL Technical manual
-8-

4.9 Connection of arrest devices STOP command
20 21 22 23 24 25
Connection of the STOP command
Button: stops and inhibits temporarily the control unit until a
new command.
Switch: keeps the automation blocked until a new retrieval
is ordered.
If the STOP input is NOT
used put the DIP 6 C on ON.
You need to use any kind of button or contact -provided it is type N.O. (normally opened)
to connect the safety devices. If there are several safety devices they have to be connected in series.
23 24 25
4.7 Connection of Courtesy light
3 4 5
Light Group
230 Vac
DIP 4 A - ON
Ifyouareusingapieceofstiwireinsteadofanan-
tenna, to obtain a 433Mhz frequency you have to cut
itoto17cmeconnectittotheclampno.25
coaxial antenna
cable sock
4.8 Connection of ANTENNA
12 13 14 15 16 17 18 19 20 21 22 23 24 25
4.10 Connection of the LSO and LSC LIMIT SWITCHES
The picture shows the connection of both limit switches.
If the LSO or LSC inputs
aren’t in use, follow the
instructions you nd
in chapter n. 4.4
The contacts of the
limit switches must be type N.O
(normally opened)
OPENCLOSE OPENCLOSE
MOTOR 1
MOTOR 2
ON
CTS
2
143 6
587 10
9
START-S4XL Technical manual
-9-
ONLY CONNECT THE ANTENNA AFTER THE
MEMORIZATION OF THE RADIO CODES IS DONE!!!

16 17 18 19 20 21 22 23 24 25
4.11 Connection of the commands “START” and “PEDESTRIAN”
The connection of the opening command START can be
realized on every button or contact as soon as it is type
N.O. (normally opened). If you have several devices to
connect you need to connect them in parallel.
By using the clamps no. 17 and no. 24 you can connect a TIMER to program the openings of the gate. The con-
tact of your timer must be a type N.O. and must stay in a close mode the whole time the gate remains opened.
If there is an opening command connection on the clamp no. 17, connect in parallel.
The connection of the command for pedestrian
opening can be realized on every button or contact as
soon as it is type N.O. (normally opened).
4.12 Connection of LOCKING
Aside is the layout of the connection of the 12 Vac locking: 16 17 18 19 20 21 22 23 24 25
START-S4XL Technical manual
-10-
4.13 Power supply of ACCESSORIES
17 18 19 20 21 28 29 30 31
+ -
TERMINAL 18-19
Tension: 24 Vac
Max Absorption: 300mA TERMINAL 19-29
Tension: 12 Vac
Max Absorption: 600mA
TERMINAL 30-31
Tension: 24 Vdc
Max Absorption: 100mA
Below the layout of the connection for a correct power supply of the accessories. Keep in mind that between
the clamps from no.19 to no. 29 there is a tension of 12 Vac.

15 16 17 18 19 20 21 22 23 24 25
POWER SUPPLY
TX PHOTOCELL
4.14 Connection of the PHOTOCELLS A (only in closing mode) 24 Vac
Receiver photocell.
Clamps contact N.C.
The contact of the photocell’s
receiver must be:
- clean (isolated from the
power supply voltage)
- type N.C.
(normally closed).
If you are using several sets of
photocells the connection must
be done in series.
Se l’ ingresso FOTO A
non viene utilizzato,
porre in ON il DIP 5 C
4.15 Connection of the PHOTOCELLS A 24 Vac with phototest
28 29 30 31
The TEST on the photocells can only ensures the correct working of the automation if said photocells are
regularly working. The control board will perform a test before every opening. In case of malfunction of the
photocells the control board will turn on the signal light for 5 seconds and will not allow the automation.
To activate the TEST function read carefully and follow the instructions in chapter no. 7
The contact of the photo-
cell’s receiver must be:
- clean (isolated from the
power supply voltage)
- type N.C.
(normally closed).
POWER SUPPLY
RX PHOTOCELL
15 16 17 18 19 20 21 22 23 24 25
POWER SUPPLY
TX PHOTOCELL
POWER SUPPLY
RX PHOTOCELL
Receiver photocell.
Clamps contact N.C.
START-S4XL Technical manual
-11-

15 16 17 18 19 20 21 22 23 24 25
POWER SUPPLY
TX PHOTOCELL
4.16 Connection of the PHOTOCELLS B (both in closing and opening) 24 Vac
The contact of the photocell’s
receiver must be:
- clean (isolated from the
power supply voltage)
- type N.C.
(normally closed).
If you are using several sets of
photocells the connection must
be done in series.
If the input PHOTO B is
not used put the DIP 7 C in
ON mode
4.17 Connection of the PHOTOCELLS B - 24 Vac with phototest
The contact of the photo-
cell’s receiver must be:
- clean (isolated from the
power supply voltage)
- type N.C.
(normally closed).
POWER SUPPLY
RX PHOTOCELL
Receiver photocell.
Clamps contact N.C.
Whenthecontrolboardispowered,the“led”lights,thatareplacedontheinputs,
are lit up when there is a closed contact towards the common on the input.
The red leds on the inputs LSC - LSO - STOP- PHOTO are normally always switched ON,
the green leds on the command inputs START - PEDESTRIAN are normally switched OFF.
4.2 Check of the connections
LSC
MOT2
28 29 30 31
15 16 17 18 19 20 21 22 23 24 25
POWER SUPPLY
TX PHOTOCELL
POWER SUPPLY
RX PHOTOCELL
Receiver photocell.
Clamps contact N.C.
START-S4XL Technical manual
-12-
LSO
MOT2
LSC
MOT1
LSO
MOT1
PHOTO A
only closing
START STOP PEDESTRIAN PHOTO B
opening /
closing

Thecontrolboardhasseveralmicro-switchestoactivatealotoffunctionsinordertondsuitablesolutionsfor
the user and to make the installation more safe.
5 Functions and adjustments
5.1 Use of the DIP A
1-OFF
2-OFF Automatic 1 By every order it inverts: open and close.
It closes automatically at the end of the pause time
1-ON
2-OFF condominium In opening and pause time it doesn’t accept commands.
it re-closes automatically at the end of the pause time.
1-OFF
2-ON Semi automatic
By every command it follows the procedure
open-stop-close-stop-open etc.
It doesn’t re-close automatically
1-ON
2-ON Automatic 2
By every command it follows
open-stop-close-stop-open etc.
It recloses automatically at the end of the pause time
3-ON Reversing
stroke
This function starts a closing thrust at the beginning or
at the end of the manoeuvre to make easy the work of
the electronical lock.
4-ON Courtesy
light
In the output of the terminal board 4 and 5 there is
tension at the beginning of the opening till 2 minutes
before closing, useful to power the courtesy light.
5-ON Pre-lighting It ables the pre-lighting before each manouevre.
6-ON Crossing
detector
As the photocells detect a crossing, the control board
opens completely then closes but 1 sec. before
according to the pause time, when the obstacle is gone.
7-ON Lamp in pause The lamp is working in the pause time, too.
8-ON Phototest Activates the phototest (in presence of TRANSCEIVER,
see Chap no. 6)
9-ON Fix light Theoutputofthelampindicatingtheopeninggateisx
insteadofashing.
10-ON
Programming
time, advanced
system
It activates the time learning with an advanced system
(see Chapter no. 5.2)
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
START-S4XL Technical manual
-13-

5.2 Setting up with DIP B
1-ON Man present
This function can able the “ Man present” function, The
START command opens the closing PEDESTRIAN com-
mand. The motors stops when the command has been
released. To go back to the normal functioning: turn o the
control board and put the DIP1 in OFF again.
2-ON
Use for
Industrial
gate
The PEDESTRIAN command is closed while the START
COMMAND has the same function of the DIP 1 and DIP 2
3-ON Rolling-code
Activate the rolling code function. The control board ac-
cepts ONLY the HCS rolling code remote controls and it
checks the rolling code counter. The remote controls can-
notbecopied.Ifit’snotactiveitonlyacceptsthexedpart
of the code.
4-ON
Controlled
gradual
start
The motors has a minimum force for the start and they can
reach the planned values. This function is not compatible
with all gates, it should be evaluated according to the
installation.
5-ON 1 motor
It able the use of only one motor. The control board makes
all manoeuvre and the motor no. 2 works simultaneously
with motor no.1 The time learning is only for ONLY motor
no. 1
6-ON Opening
displacement
If you put the DIP SWITCH in ON the opening displacement
will be at 2 seconds. The closing displacement time can
bechosenwiththetrimmer“displacement”.
7XLeave in OFF
8-9-10
OFF
Time learning
planned from
the user
Leave in OFF when using the planning time set up from
the user, otherwise see the diagram below.
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
START-S4XL Technical manual
-14-

TIME “START“ IN OPENING
AND CLOSING
TIME “PEDESTRIAN“
IN OPENING AND CLOSING
8 ON
9-10 OFF 10”(seconds) 6”(seconds)
9 ON
8-10 OFF 14”(seconds) 8”(seconds)
8-9 ON
10 OFF 18”(seconds) 10”(seconds)
10 ON
8-9 OFF 22”(seconds) 12”(seconds)
8-10 ON
9 OFF 26”(seconds) 14”(seconds)
9-10 ON
8 OFF 32”(seconds) 18”(seconds)
8-9-10 ON 38”(seconds) 20”(seconds)
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
5.3 Diagram of PEDESTRIAN time and START time
1-ON LSC M2
12 Exclusion of the inputs closes limit switches motor no.2
2-ON LSO M2
13 Exclusion of the inputs opens limit switches motor n. 2
3-ON LSC M1
14
Exclusion of the inputs of the closing limit switches
motor no.1
4-ON LSO M1
15
Exclusion of the inputs of the opening limit switches
motor no.1
5-ON Photocell A
16 Exclusion of the input of photocell working in closing.
6-ON STOP
21 Exclusion of the input stop
7-ON Photocell B
23 Exclusion input photocell always activated.
8-ON Radio-
receiver It activates the radio-receiver
ON
CTS
2
143 6
587
ON
CTS
2
143 6
587
ON
CTS
2
143 6
587
ON
CTS
2
143 6
587
ON
CTS
2
143 6
587
ON
CTS
2
143 6
587
ON
CTS
2
143 6
587
5.4 Setting up with DIP C
ON
CTS
2
143 6
587
START-S4XL Technical manual
-15-

6 Using the remote controls
Thecontrolboardcanacceptdierenttypeofcodes,therstmemorizedremotecontroldenesthetype,consequently,other
typeofcodes(dierentfromtherstmemorizedremotecontrol)cannotbelearnt.Thecontrolboardacceptsstandardcodes
from12to64bitandonlythexedpartofthecodefortherollingcodeHCS©,butusingtheDIP3-Btherollingcodecounter
canbemonitored.Thiswaytheremotecontrolscannotbecopied.Thememorycapacityisabout200dierentrollingcodes.
The rst memorized remote control denes the type of code that the receiver shall learn, consequently, the subsequently
memorized remote controls must have the same type of code.
This operation cancels all previous memorized codes. It is not contemplated the cancellation of a single remote
controlcode.Itisnecessarytoresetthememorybeforelearningtherstremotecontroltoavoidtheremaining
of previously memorized codes that aren’t in use in the installation.
The cancellation of the memory (all codes) is possible only when the gate is closed.
1Make sure that the gate is in CLOSED position.
Press and keep pressed the codes button
2Wait for the L.E.D. CODES tostartashing,thenreleaseit.
Wait until the reset of the memory.
6.1 FULL CANCELLATION of the memory
CODES
CODES
6.2 Learning of the remote controls
The remote controls can be learnt ONLY when the gate is CLOSED.
PERFORM THE LEARNING WITHOUT CONNECTING THE ANTENNA TO THE CLAMPS NO. 17-18
- If you need to learn a new remote control repeat the same operation.
- When you push the remote control’s button and the L.E.D. codes is switched ON, it means that the remote control is not
compatible.
-Whenyoupushtheremotecontrol’sbuttonandtheL.E.D.codesashesslowly,itmeansthatthememoryisFULL.
- In this card is not previewed the cancellation of a single remote control ‘s code.
1Make sure that the gate is in CLOSED position.
> 2Press and release the CODES button, the LED CODES will stay lit.
3Press the button of the remote control, ex: button no.1:
if it is memorized L.E.D. CODESwillash
> 1Press and release the CODES button, the L.E.D. CODES will stay lit.
> 2Press again the CODES button, the LED CODESwillashandstaylit
3Press the button of the remote control, ex:
button no.2: if it is memorized L.E.D. CODESwillash
CODES
CODES
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
CODES
START-S4XL Technical manual
-16-
START
PEDESTRIAN

7 Time learning
The gate is in closed position
1Put in OFF the switch no. 10 of the DIP A The automation is in
CLOSED position.
2 * Push the button TIMES TherstmotorOPENS
... After the phase-deplacement,
automatically... ... the second motor OPENS
3Push the button TIMES (or START)
(If the opening limit switches are not available)
Therstmotorstops;
wait until the second motor stops.
... If the limit switches are available,
wait until both motors stop.
Let the PAUSE TIME you need pass.
4Press the TIMES button The second motor CLOSES
... after the phase-deplacement time... ...Il 1° parte motore in CHIUDE
5Press the TIMES button (or START)
(if the limit switches are not available)
The second motor stops,
waituntiltherstmotorstops.
END OF LEARNING TIME.
... if the limit switches are available wait until
both motors stop.
The second motor stop, wait until
therstmotorstops.
END OF LEARNING TIME
TIMES
7.1 Time learning: NORMAL WAY
*AftertherstpushoftheTIMESbuttonyoucanusetheSTARTcommandfromtheclampno.17orfrom
the learned remote control.
The control board START S4XL has two way to plan the working time.
NORMAL WAY: use this system when the doors are the same and the motors are the same.
ADVANCED SYSTEM: use this system when you want to set up the exact timing of slown down and/or the
doorshavedierentworkingtimes.
TIMES
TIMES
TIMES
CTS
87 10
9
START-S4XL Technical manual
-17-

The gate is in CLOSED position
1Put and leave in ON the DIP 10A The gate is in closed position
2 * Push the button TIMES TherstmotorOPENS
3
Push the button TIMES (or START)
If the slowing down is activated
trimmer see. Slow down) ...
Therstmotorslowsdown
when opening
4
Push the TIMES button (or START)
(if the opening limit switches of motor no.1 is not
available).
Motor no.1 stops,
then motor no. 2 OPENS
4 a ... If the limit switch is available
wait until the rst motor stops
Motor no.1 stops,
then motor no. 2 OPENS.
5Push the TIMES button (or START) if the slowing
down is activated (trimmer V. Slow down) ...
The second motor slows down
when opening
6
Push the button TIMES ( or START)
(if the opening limit switches motor no. 2
is not available)
The second motor stops, the
counting of the pause time starts
6 a ... If the limit switch is available wait until
motor no. 2 stops.
The second motor stops, the
counting of the pause time starts
Let the required pause time run…
7Push the TIMES button (or START) The second motor CLOSES.
8Push the TIMES button (or START) if the slowing
down is activated (trimmer see Slow down)
The second motor slows down
when closing
9Push the TIMES button (or START) (if the closing
limit switch of motor no.2 is not available)
The second motor stops,
therstmotorCLOSES
9 a ... if the limit switch is available wait until
motor no. 2 stops
The second motor stops,
therstmotorCLOSES
10 Push the TIMES button (or START) if the slowing
down is activated (trimmer see Slow down)
The motor no.1 slows down
when closing
11 Push the button TIMES (or START) if the closing
limit switches of motor no.1 is not available.
Motor no.1 stops. End of
ADVANCED LEARNING TIME.
11 a ... if the limit switches is available wait the
stop of motor no.1
Motor no.1 stops. End of
ADVANCED LEARNING TIME.
7.2 Time learning: ADVANCED SYSTEM
* After the fi rst push of the TIMES button you can use the START command from
the clamp no.17 or from the learned remote control
TIMES
TIMES
TIMES
TIMES
CTS
87 10
9
START-S4XL Technical manual
-18-

The gate is in closed position
1
Press and keep pressed the TIMES button till the
control board starts motor no. 1 in OPEN, then
release the TIMES button
Motor no.1 OPENS
2Press the TIMES button Motor no.1 CLOSES
Let the desired pause time run for the PEDESTRIAN OPENING
3Press the TIMES button Motor no.1 CLOSES
4Push the button TIMES (if the closing limit switches
of motor no.1 is not available)
Motor no.1 stops.
The pedestrian door is closed.
End
4 a ... If the limit switch is available wait until the
motor no.1 (pedestrian use) stops in its closing
Motor no.1 stops by closing limit
switches. The pedestrian door is
closed. End.
7.3 Time learning PEDESTRIAN WAY
TIMES
TIMES
TIMES
TIMES
7.4 Time learning: pause (fastest way)
The gate is in PAUSE
1Press and release the TIMES button THE L.E.D. lights for opening and
closing are witched ON
Let the new pause time run…
2Press and release the TIMES button The gate CLOSES. End of the fast
learning time and PAUSE TIME.
TIMES
TIMES
START-S4XL Technical manual
-19-

7.5 Reset of the memory
The reset of the memory programm the standard values of the remote controls. It doesn’t cancel the codes:
therearetwodierentmemories.
1Press the buttons CODES AND TIMES
LED OPEN, CLOSE and CODICI lit ON.
2Wait 10 seconds unitl LED OPEN, CLOSE and CODE will switch OFF
3Release the buttons CODES and TIMES
TIMES CODES
TIMES
OPEN CLOSE CODES
CODES
OPEN CLOSE CODES
8 Instruction for TEST
Now the control unit check ethe devices under TEST and the depart of the doors can be delayed
Connect for the TEST:
1When the control is switched OFF, put in OFF dip 8 of DIP A
2PowerthecontrolunitandwaitthestandardashoftheLed
3Put in ON DIP 8 of DIP A
4Let the gate open with a START
commande or the time learning if necessary (Par. 5.1)
The TEST function is compatible with devices with slow reponse ( for example TRANSCEIVER) so when those
devices are available the response time can be slower. You can test the devices in the STOP input.
Follow this procedure to know if some devices connected ot the inputs FOTO, FOTOSTOP (photocell B) and
STOP are under TEST.
ON
CTS
2
143 6
587 10
9
ON
CTS
2
143 6
587 10
9
LED
START
START-S4XL Technical manual
-20-
Table of contents