EcoForce Eliminator Elite Installation manual

Operations Manual
Electric Heat Systems
855-4-ECOFORCE
www.EcoForceHeatSystems.com
www.HotelBedBugHeaters.com
www.BuyBedbugHeaters.com
EcoForce Heat Systems, LLC®
855-432-6367
2432 W. Peoria Ave Ste 1187
Phoenix, AZ 85029
PLEASE READ AND SAVE THESE INSTRUCTIONS

INDEX:
Introduction ………………………………………………..………………………………………. 2
Safety Instructions .……………………………………………………………………………… 2,3
EcoForce Pro R-26 ……………………………………………………………………………… 4-6
EcoForce Eliminator …………………………………………………………………………….. 7-9
EcoForce Pro-R52 ……………………………………………………………………………. 10-12
Double Universal Air Mover Heater ……………………………………………………..……13,14
Temperature Settings ………………………………………………………………………….…..16
Best Practices …………………………………………………………………………………. 16,17
Warranty …………………………………………………………………………………………… 18
1

Introduction
Thank you for purchasing your EcoForce Heat Systems® heater! EcoForce Heat Systems is proud to bring a series
of innovative products geared toward fighting the ever growing bed bug population. Our goal is to incorporate the
most advanced technology in today’s market to provide property owners and service professionals alike the ability to
kill bed bugs with heat. Our bed bug heat systems offer affordability, excellent performance, compact design, and
ease of use.
Safety Instructions
Read this owner’s manual carefully before using your pest control electric system! Warning:
Ignoring these safety precautions may result in personal injury.
Never use your heater in conditions exceeding 140ºF.
Never set the thermostat control to higher than 140ºF.
Never use an extension cord smaller than 12 gauge or longer than 100’.
2

Safety Instructions (Cont’d)
Always check building circuits for proper grounding before plugging in your heater.
Never drop or bounce. Internal damage may occur.
Never clean or service your heater while plugged into a live electrical power source.
Never operate in standing water.
Always wear rubber gloves and boots when operating in damp conditions.
Always keep the air inlet & outlet clear of any obstructions and loose material. Never operate the EcoForce
Eliminator Elite or 52K without the fan on. Never operate the EcoForce Pro-R26 without the fan attached.
Never operate your heater with a loose cord connection or damaged power cord(s).
Never connect power from different buildings to the heater.
3

4
ECOFORCE Elite 8
Specifications:
NEC® Compliant
Yes
UL® Listed
Yes
Amps Per Heating Element
8
Total Amps
64
Volts
120VAC
WATTS Per Heating Element
960
Total WATTS
7,680
BTU’s
26,190
Fan
Yes
Air Volume
2,700 CFM’s
Adjustable Thermostat Controlled
Yes, Digital
Max Temperature Setting
132ºF
Weight
42lbs
EcoForce Elite 8

Operating Your EcoForce Elite 8
Unpack & inspect your EcoForce Elite 8 for damage – Do not use if damaged. Check all heating
elements to make sure everything works and nothing was damaged from shipping. If damaged from
shipping do not use and contact us immediately at 480-304-5649.
Your EcoForce Elite 8 heater has Eight (8) 120volt plug-ins for the heat elements, four (4) located on each
side of the heater. Each heating element is 8 amps or 960 watts. Two (2) heating elements can be plugged
into a 20 single amp circuit. With (4) 20 amp circuits you can achieve full power of your EcoForce Elite
8.
If needed, you can use a 240 volt single phase splitter box to supply power to the heater via a 240 volt
electric dryer or range outlet. You can also use our hotel air conditioner splitter (A/C Pro Splitter) to
power (4) of the heating elements. When using the hotel air conditioner splitter all four (4) receptacles
must be used and must draw identically equal power. Do not plug one of the connections from the
splitter into the inlet plug-in with the green indicator light. This plug-in also provides power to the
switches and thermostat controller and draws slightly more power than the rest.
5

Operating EcoForce Elite 8 (Cont’d)
Step 1- Using a 12 gauge extension cord, plug the heating element with the green indicator light into a
wall outlet. DO NOT plug A/C Splitter (if equipped) into the green indication element as this plug also
provides power to the Fan, ON/OFF switch and thermostat controller.
Step 2- Plug in the remaining heating elements to the power supply required for your application.
Step 3- Turn on fan via the green toggle switch on top of the heater. Note: This must be done before
turning the heater on!
Step 4- Turn on the heater by pressing the red toggle switch located on the top of the heater next to the
thermostat controller.
Step 5- Adjust thermostat setting to desired Maximum temperature. (See Instructions for Temperature
Controller on page 16)
6

7
EcoForce Eliminator Elite
ECOFORCE ELIMINATOR
Specifications:
NEC® Compliant
Yes (20 Amp Breaker)
UL® Listed
Yes
Amps Per Heating Element
12.5
Total Amps
48
Volts
120VAC
WATTS Per Heating Element
1,500
Total WATTS
6,000
BTU’s
20,460
Fan Speed
1 Speed
Air Volume
2700 CFM’s
Adjustable Thermostat Controlled
Yes, Digital
Max Temperature Setting
140ºF
Weight
39 lbs
Dimensions
21” x 11” x 22”
Heating Elements

Operating Your EcoForce Eliminator Elite
Unpack & inspect your EcoForce Eliminator Elite for damage – Do not use if damaged. Check all
heating elements to make sure everything works and nothing was damaged from shipping. If
damaged from shipping do not use and contact us immediately at 480-304-5649.
Your EcoForce Eliminator Elite has one (1) cord for the fan wrapped around the cord storage handle on
top of the unit. The power control plate located on the top left of the cord storage handle contains one (1)
Green switch for fan and thermostat operation, one (1) Red switch for activating the heating elements, and
one (1) digital thermostat. The heating element receptacle plate is located on the bottom left side of the
heater below the power control plate. There are four (4) 115volt 3 prong receptacles on the receptacle
plate for supplying power to the heating elements that are installed inside the heater in front of the fan.
Each heater receptacle is 1500 watts or 12.5 amps at 120 volts and can be safely connected to a 15 amp
120 volt circuit. If necessary, use a single phase 240 volt splitter box to supply power to the heater via a
240 volt electric dryer or range outlet. You can also use our hotel air conditioner splitter (Eliminator A/C
Splitter) to power two (2) of the heating elements. When using the hotel air conditioner splitter both plugs
MUST be used and MUST draw identically equal power. Do not plug A/C Splitter into anything other
than the heating element plug-ins or damage may occur.
8

Operating Your Eliminator (Cont’d)
Step 1 - Plug the black power cord attached to the heater into a wall outlet. This cord supplies power to
the fan and thermostat controller. You must have this cord plugged in or the unit will not operate.
Step 2 - Plug the four (4) heating elements into the appropriate power source for your application.
Important: You MUST use at least twelve (12) gauge extension cords when supplying power to the
heating elements on your Eliminator Elite heater.
Step 3 - Turn on the heaters fan by pressing the Green switch on the left side of the control plate.
Step 4 - Turn on the heating elements by pressing the red switch on the right side of the control plate.
Both indicator lights and the thermostat should be illuminated at this time.
Step 5 - Adjust thermostat setting to desired maximum temperature. (See Instructions for Temperature
Controller on page 16)
Important: If you block the inlet or the outlet of the unit the heating elements will shut-off or will not turn
on. This safety feature insures that proper minimum airflow must be maintained so the heating elements
do not overheat.
9

10
30 Amp Side
50 Amp Side
EcoForce 52K Elite Specifications:
NEC® Compliant
Yes
UL® Listed
Yes
Amps Per Heating Element
24 Amp 240 VAC (30Amp Circuit)
40 Amp 240 VAC (50 Amp Circuit)
Volts
240 Volts
Total Watts
15,360
BTU’s
Total: 52,377
1- heating element of 32,736 BTU’s
1- heating element of 19,641.6 BTU's
Fan
Included, Attaches to Heater
Air Volume
2700 CFM
Adjustable Thermostat Control
Yes
Max Temperature Setting
140ºF
Weight
42 lbs
Diminsions
24"x16"x24"
Warranty
1 Year on Parts and Labor
Additional Equipment Required
Yes
8 Gauge Cord/ 40 Amp Element
10 Gauge Cord/ 24 Amp Element
EcoForce 52K Elite

Operating Your EcoForce 52K Elite
Unpack & inspect your EcoForce 52K Elite heater for damage – Do not use if damaged. Check all
heating elements to make sure everything works and nothing was damaged from shipping. If
damaged from shipping do not use and contact us immediately at 480-304-5649.
Your EcoForce 52K Elite is equipped with one (1) power cord wrapped around the cord storage handle.
There are two (2) individual 240 volt heating element plug-ins on sides of the heater near the bottom. As
you are looking at the front of the heater, the supplied pigtail on the bottom left of the heater operates a 40
amp or 9,600 watt heating element, you will need a minimum circuit of 50 amps at 240 volts to operate
this element. The black control plate on the bottom right of the heater operates a 24 amp or 5,760 watt
heating element, you will need a minimum circuit of 30 amps at 240 volts to operate this element. The
heating elements can be run independently, but must be run together to achieve full power.
Step 1 - Plug the power cord for the fan into a 115 volt electrical outlet. Plug the heater’s 40 amp (left)
heating element into an approved 50 amp 240 volt power source via the supplied locking connecter. A
minimum of #8 gauge cable shall be used to operate this element up to one hundred (100) feet. Plug the
24 amp (right) heating element into an approved 30 amp 240 volt power source via the supplied L6-30
locking connector. A minimum of #10 gauge cable shall be used to operate this element up to one hundred
11

Operating Your EcoForce 52K Elite (Cont’d)
(100) feet. Be sure to fully seat and twist lock the connectors with a right hand (clockwise) twisting
motion. Important: If the connections are not fully seated and locked damage may occur.
Step 3 - Start the heater’s fan by pressing the Green switch on the top right control plate of the heater.
Note: This MUST be done prior to turning the heater on or the heater will not operate.
Step 4 - Turn the individual heating elements on via the Orange toggle switches on the top left control
plate just above the thermostats. All lights and thermostats should be illuminated at this time.
Step 5 - Adjust each thermostat setting to desired Maximum temperature. (See Instructions for
Temperature Controller on page 16)
12

Double Universal Air Mover Heater
13
Double Universal Air Mover
Specifications:
NEC® Compliant
Yes
UL® Listed
Yes
Amps
7.5 x 2 Amp
Total 15
Volts
115 Vac
Watts
862.5
BTU’s
2941 x 2
Total BTU’s
5,882
Fan
No
Adjustable Thermostat
Yes
Additional Equipment Required
Yes, Air Mover Fan

Operating Your Double Universal Air Mover Heater
Step 1- Attach the spring loaded heater body to virtually any axial or centrifugal air mover.
Step 2- Plug attached power cord(s) into acceptable power source. Each power cord operates a single
heating element and utilizes 7.5 amps of power at 115vac. If both elements are not required for your
application a single element can be used.
Step 3- Turn on air mover (Important: air MUST flow through the heater coils to ensure that proper
minimum airflow is maintained to prevent overheating and shut off)
Step 4- Move red power switch to Up/On position. Indicator light will be illuminated when on.
Step 5- Adjust thermostat setting to desired Maximum temperature. (See Instructions for Temperature
Controller on page 16)
14

Instructions for Temperature Controller
EcoForce Eliminator and EcoForce Pro series heaters come with a state of the art digital temperature
controller(s) built into the unit. Each controller is preset to 132ºF. There is no need to adjust the controller
to operate your heater unless you want to change the temperature settings above or below 132ºF.
To change the high temperature setting push the set button on the thermostat and use the arrows to adjust
temperature up or down. Push the set button again when finished.
Best Practices for Heating Rooms
1. Heat rises. Always try to seal the room(s) from escaping heat. Especially HVAC vents, bathroom exhaust fans,
bottoms of doors, wall air-conditioners, etc... Cover window pane with reflective material, blankets or
equivalent to minimize loss of energy from cold windows.
2. Remove heat sensitive items such as but not limited to: Candles, crayons, and other waxy or meltable items, soft
plastic or vinyl items (example: window blinds, vinyl records), all aerosols, lighters, fire extinguishers,
medications, photographs in open areas, fresh fruits and vegetables, carbonated beverages, wines, liquors, etc…
15

3. Unplug all household electrical items and do not place electrical items directly in front of the heater. Electrical
items are rated for higher temperatures than you are heating, just avoid the direct heat coming out of the heater.
4. It is best to bag clothes, sheets, etc... and run in the clothes dryer for 20 minutes on high. Never leave clothes
laying on the floor or other surfaces or they will act as an insulator and it will be difficult to heat under them
sufficiently.
5. Open all drawers and separate all items so hot air can get everywhere easily.
6. Stand or block box spring and mattress so hot air can contact all sides.
7. Place all fans blowing in the same direction along the walls in the area you are heating to circulate the hot air
into every nook and cranny. If possible place at least one fan per wall. Turn on fans to ensure air movement is
sufficient. Add more fans if it does not feel like a whirl wind (tornado type effect).
8. Place heater(s) so that the air is being immediately swept up by the fans and the hot air coming directly out of
the heater is not directly hitting any furniture or building materials before being blown about by the fans.
9. For maximum performance use no less than 1 heater for every 225 sq. ft in a normal room with a ceiling height
of 9’ or less (2,025 cu ft). You can never have too much equipment, only not enough.
16

10. Always check for fire sprinkler’s installed in a building. Keep temperatures at the fire sprinkler head a
minimum of 30ºF below the trigger temperature of the fire sprinkler.
11. Walls and ceilings made of block or concrete require more heat because they are more conductive of energy
than drywall. This means 1 heater will heat less space when you have walls and/or ceilings with block or
concrete. 50% more power is a general rule for these rooms. All buildings are not created equal and more
conductive materials take more energy to heat.
17

Limited Warranty
K & J Products, LLC’s Limited Warranty covers the unit from defects in material and craftsmanship. The warranty
covers normal use for a term of one year from the original date of purchase including parts, labor and one way
shipping. Non-contiguous states must pay for roundtrip freight. A purchase receipt must be provided.
IMPORTANT!
This warranty does not cover or apply to defects due directly or indirectly to misuse, abuse, disassembly, alteration,
corrosive chemicals, improper voltage, fire, flood, negligence, accident, improperly or incorrectly performed
maintenance or repair, failure to perform necessary maintenance or repair, or if the use of this product is not in
compliance with the instructions and specifications for its use.
In order to receive service or replacement parts under warranty, you must:
1) Contact us before warranty expiration
2) Call 855-432-6367 for return merchandise authorization number (RMA#)
3) Provide original, legible proof or purchase, and
4) Ship to: K & J Products, 6677 Inter Cal Way, Prescott, AZ 86301 PH: 602-478-1473
18

Copyright EcoForce Heat Systems, LLC® 2014
All Rights Reserved
Manual Ver.12.16.16