ECOheat ES806 User manual

© Eco Heat Equipment – January 2016 1 of 2
ES806 Passive Infrared (PIR) Dual Technology Ceiling
Mount Motion Sensor User Manual
General
The ES806 is a ceiling mount motion sensor with PIR and Microphone dual
technology. The combination allows the sensor to detect motion and sound (if
enabled).
This sensor is ideal for larger areas, such as open plan offices and large rooms.
Once the primary detector (PIR) senses motion, the lights will be switched ON –
should the motion be insufficient the microphone (if enabled) will continue to keep
the lights on when detecting sound.
When the area is vacated and the sensor detects either no motion or sound the
light/s will remain on until such time as the pre set time delay has lapsed.
If, after reviewing this guide, you require additional information or assistance
please contact Eco Heat Equipment at info@ecosensor.co.za, +27 (0)861 999 887,
or www.ecosensor.co.za.
Technical Specifications
§Voltage: 220 – 240V/AC
§Frequency: 50/60Hz
§Load: Incandescent max: 1 000W
Fluorescent max: 600W
LED max: 300W
§Detection Angle: 360 °
§Detection Range: 1 – 10m radius
§Light level: 10 – 2 000 LUX
§Time setting: 10 seconds – 30 minutes
§Installation height: 2.5m – 3.5m
§Working temperature: -10°C to 40°C
§Dimensions: 115mm diameter x 54.9mm(H)
Safety
Any incorrect use or installation procedure not recommended by the
manufacturer may cause fire, electrical shock or injury to persons.
Box Contents
Your box should contain the following items:
§Sensor
WARNING:
Controlling a load in excess of the specified ratings will damage the unit and lights
and could pose risk of fire and electric shock.
Do not install this unit to control a power socket.
Installation Instructions
WARNING: ALL WIRING MUST BE DONE IN ACCORDANCE WITH NATIONAL AND
LOCAL ELECTRICAL CODES AND STANDARDS.
Note: motion sensors respond to rapid changes in temperature so care should be
taken not to mount the device near a climate control source (i.e. heaters or air
conditioners). Hot or cold draughts will seem like body motion to the sensor and will
trigger the device. Recommended distance from climate control devices is 2m.
1. Turn power off at circuit breaker or fuse
2. Remove top cover from base of sensor
3. Connect wires as per diagram
4. Sensor can be secured onto ceiling with M5 butterfly screws/spring toggle
5. Restore power at circuit breaker or fuse
Sensor calibration:
Note: Allow up to 1 minute for the motion sensor to recalibrate after it has been
connected for the very first time. This is only necessary during installation or when
the mains supply is disconnected.
Operation and Field of View
The motion sensor detects motion within its coverage area and controls the
associated lighting connected to the sensor. The passive infra red (PIR) sensor is
sensitive to the heat emitted by the human body. In order to trigger the sensor the
source of heat must move from one zone of detection to another. The device is
most effective in sensing motion across its field of view and less effective sensing
motion towards or away from its field of view.
Installation wire diagram
Sensor detection range from side: large motion
Sensor detection range from top: large motion
Motion Sensor Settings and Adjustments
The motion sensor is a Passive Infra Red (PIR) type electronic occupancy detector,
which in turn switches the lights when connected to the motion sensor. There are
four adjustments that can be made to influence the operation of the motion
sensor:
1. RANGE: motion detection range
2. TIME: time delay after motion/sound until shut off
3. LUX/LIGHT: level of ambient light sensitivity
4. MICROPHONE: use of sound as backup to motion detection to keep the
device on.
The four adjustments settings are as follows:
Detection range: 1m to 10m radius
Time setting range: 10 sec to 30 min
Lux (light) sensitivity: 10 to 2 000 LUX
Microphone: On/Off
Manual Override
For manual control, the ES806 motion sensor features a convenient push button
switch.
If the lights are OFF, pressing the button will turn the lights ON for as long as the
room is occupied. The lights will turn OFF once the room is vacant, after the
delayed OFF time expires.
If the lights are ON, pressing the button will turn the lights OFF and keep them OFF
even if the room is occupied. This feature is particular useful when the automatic
motion sensor settings need to be overridden. The lights can be turned back ON
by simply pressing the button. The sensor will return to normal operation.

© Eco Heat Equipment – January 2016 2 of 2
Motion Sensor Adjustments
The motion sensor’s settings can be adjusted as follows:
Step 1 – Adjust the TIME setting to minimum
Turn the TIME control fully anti-clockwise to set to the 10 second testing setting.
Step 2 – Adjust the LUX/LIGHT setting to maximum
Turn the LUX/LIGHT fully clockwise to set to maximum (sensor functioning in all
lighting conditions).
Step 3 – Adjust the RANGE setting
Turn the RANGE control fully anti-clockwise. Move away from the sensor until the
LED stops blinking. This will be the minimum detection range for the setting. To
increase the range, turn the control clockwise until the desired distance is reached
(1m – 8m maximum).
Step 4 – Adjust the LUX/LIGHT setting
If the LUX/LIGHT control is set to maximum (fully clockwise), the lights will turn ON
whenever the room is occupied, even in full daylight.
Alternatively, turn the LUX/LIGHT anti-clockwise until the desired LUX setting is
achieved.
Step 5 – Adjust the TIME setting
Turn the TIME control clockwise until the desired delay is reached (10sec (testing)
to 30mins).
Factory time out is pre set to 10 seconds.
NOTE: All the time intervals are within approximately 10 seconds of the stated time
out interval.
Step 6 – Microphone (audio sensor)
To disconnect the microphone, press the Push button once to activate the manual
override (sensor will turn OFF). Then hold down the Push button until the LED starts
to blink (approximately 5sec). Press the Push button once more to deactivate the
manual override (sensor will turn back ON). The PIR will continue to operate when
the microphone is disconnected.
To reconnect the microphone, repeat steps above.
Disabling the microphone is ideal for areas where there are high ambient sound
levels, such as near a busy road or in a shopping center.
NOTE: Sensor must first detect motion (PIR) to switch the device on. Sensor will NOT
switch the device on if no motion is detected.
OTHER CAUTIONS:
Disconnect power when working on electrical outlets or components.
Do not push on the surface of the lens.
Cleaning
Carefully wipe sensor with a soft damp cloth. Do not apply pressure to the lens.
Recycling
Please recycle all packaging material that came with the motion sensor.
Warranty
The sensor has a three (3) year warranty after the date of the original purchase.
Please keep your original receipt, as this will be required for any claims under this
warranty. The warranty is a strictly carry in policy. (The sensor/s must be returned to
Eco Heat offices for a claim to be processed).
The warranty does not cover:
§damage from misuse,
§neglect or abuse,
§products that have been modified in any way,
§shipping and handling cost associated with the product,
§damage resulting from accidents, lightning, fire, water, power surges,
natural disasters and/or incorrect installation
For more information, view the Return/Refund Policy at www.ecosensor.co.za.
Optional Remote Control
The sensor LED will flash 3 times to
confirm each setting applied
ON=Always on. After about
six hours turns to “AUTO”
mode.
OFF=Always off. After about
six hours turns to “AUTO”
mode.
Automatic ON/OFF
Test mode: Light level will not
influence the operation in this
mode. Use to test and setup
detection range.
Reset: Resetting of all
functions to:
Time: 10sec
Range: Max
Lux: Max
Microphone ON/OFF (if
applicable)
Automatic reading and
saving of the actual light
level
Permanent tamper
protection: Lock all settings
to avoid tampering. Only
On and Off buttons will be
functional.
Lux/Light settings (10 to 2000
Lux).
Recommendation: rooms
with daylight 500 Lux, without
daylight 2000 Lux.
Time settings (10 secs to 30
mins)
Range settings (2m to Max)
Trouble Shooting
Malfunction
Possible Cause
Remedy
The unit will
not switch
“on”
a. No mains power
b. No movement is
detected (in detection
zone)
c. Wrong LUX/LIGHT level
setting
d. Electrical circuitry faulty
e. Electrical Installation not
done correctly
f. Unit may be faulty
a. Check mains power is on
b. Move towards the unit (in
detection zone) or increase the
detection range settings
c. Adjust setting on the LUX/LIGHT
settings
d. Refer to the ‘Electrical
Installation’ section to ensure
correct installation
e. Have a certified electrician
disconnect and test the unit
f. Contact Eco Heat Equipment
Unit stays
“on”
permanently
g. Continuous movement in
detection zone
h. The sensor is not
mounted correctly for
reliable operation
i. Wrong LUX/LIGHT level
setting
j. Time setting control is set
too far
k. Unit may be faulty
g. Check detection range setting
and reduce detection range
sensitivity
h. Check detection range setting
and mounting procedure
i. Adjust setting on the LUX/LIGHT
settings
j. Adjust the time setting control
k. Contact Eco Heat Equipment
Due to minor improvements in design or otherwise, the product you purchase
may differ from the one shown in this leaflet. For more information or advice on
this or any other Eco Heat Equipment products, visit www.ecosensor.co.za or
phone +27 (0)861 999 887.
Indemnity: The Author, and supplier, shall not be held liable for any loss, injury or
damage, of whatsoever nature, whether consequential or not, either contractual
sustained to, or caused by, or which may arise through the use of any comments,
suggestions, circuitry, services or equipment offered for purchase. The User,
indemnifies the author and supplier, and agrees not to hold him/her responsible
for any damages, losses and/or liabilities (including legal costs on a scale as
between attorney and user) arising from, or through the use of circuit diagrams,
equipment and services, whether such circuit diagrams, equipment and services
were used with the consent of the User or not. All risks attached to the use of
circuit diagrams, equipment and the connection thereof to the User’s equipment
shall be deemed to have passed onto the User, once having purchased such
equipment from the author or supplier.
!
!
OFF
ON
!
AUTO
!
TEST
!
RESET
!
!
!
!
2000
LUX
!
500
LUX
!
!
10SEC
30MIN
!
!
2M
8M
Other ECOheat Security Sensor manuals