ECOLOBLUE 30 Series User manual

1
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
EcoloBlue™30 Series
Atmospheric Water Generator

1
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
TABLE OF CONTENTS
INTRODUCTION .................................................................................................................... 4
SAFETY ................................................................................................................................. 4
WARRANTY ..........................................................................................................................6
MODEL 30 SERIES GENERATOR DESCRIPTION ..................................................................7
How the Atmospheric Water Generator Works.............................................................7
Key features of the Atmospheric Water Generator ......................................................8
Components of the Atmospheric Water Generator ......................................................8
Display Description – Model 30 Series ....................................................................... 11
Additional Display Options and Settings.....................................................................12
SET-UP................................................................................................................................14
Preparation and Location............................................................................................14
INSTALLATION CHECKLIST ........................................................................................15
Reverse Osmosis Filter Installation............................................................................16
Cleaning.......................................................................................................................17
Flushing the System....................................................................................................17
Optional Connection to Municipal (City) Water ...........................................................18
OPERATION.........................................................................................................................20
Turning Generator ON/OFF.........................................................................................20
Dispensing water.........................................................................................................20
Heating and Cooling Water .........................................................................................20
MAINTENANCE...................................................................................................................21
Parts Replacement .............................................................................................................22
A. To replace a filter: ...................................................................................................22
B. Replace the top UV lamp.........................................................................................24
C. Replace the cool water out UV lamp.......................................................................24
D. Replace the Bottom Tank UV Lamp........................................................................26

2
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
CLEANING...........................................................................................................................27
Cleaning the Air Filter.................................................................................................27
Cleaning the water collector.......................................................................................29
Cleaning the bottom tank............................................................................................31
SANITIZING .........................................................................................................................31
CO2 Operation Model 30s ...................................................................................................33
TROUBLESHOOTING...........................................................................................................35
CERAMIC MINERAL FILTER ...............................................................................................37
TECHNICAL SPECIFICATIONS............................................................................................39
MAINTENANCE LOG ...........................................................................................................40
NOTICE: The EcoloBlue Life & Energy Atmospheric Water Generator 30 Series is intended for INDOOR
USE ONLY in homes or small office.
3109 Grand Avenue - Suite 423, Miami, Florida 33133
5702 Marsh Drive -Unit K, Pacheco, California 94553
800-691-6043 Outside U.S. +1-925-231-0206
Technical Support: 9:00 a.m. - 5:00 p.m. Pacific Time, M-F
www.EcoloBlue.com
E-mail: info@EcoloBlue.com

3
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
INTRODUCTION
Thank you for purchasing the EcoloBlue Atmospheric Water Generator. This Atmospheric Water
Generator is a state-of-the-art water generating Appliance using the latest technology available to the
industry. EcoloBlue designed your Atmospheric Water Generator with one objective in mind: produce
the maximum amount of high quality drinking water using only a minimum amount of electricity. In
addition to atmospheric water production, the Appliance can also be used as a conventional water
purifier by connecting it to an external municipal (city) water source.
SAFETY

4
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
Do not, under any circumstances, cut, remove, or bypass the grounding
prong.
WARNING! Your EcoloBlue must be plugged directly into a properly grounded and
polarized three-prong receptacle. lf the wall receptacle you intend to
use will not accept a three-prong plug, or if you are not sure the outlet is
adequately grounded or protected by a time delay fuse or circuit breaker,
have a qualified electrician install the proper outlet according to the Na-
tional Electrical Code and applicable local codes and ordinances. Do not
use an extension cord or an adapter plug.
Avoid fire hazard or electric shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong from the power cord.
Do not use the Water Generator if it’s electrical plug or power cables have
been damaged. Assure there are no knots in the power cord.
Always unplug the power cord before performing any maintenance on
your unit.
Do not connect the Water Generator to a circuit operating other high pow-
er consuming Appliances, such as a toaster, hot plate or refrigerator.
Avoid prolonged direct eye exposure to the ultraviolet (UV) devices in this
Appliance, as UV light can damage the eye. Do not look at the bulb.
WARNING! Do not insert or unplug the power cord with wet hands or while in contact
with another grounded device, Appliance, or radiator.
Operating voltage must not drop below 10% of standard Power supply.
When the unit operates below this level, the unit becomes noisy and may
overheat. If this occurs, immediately switch the unit off until the voltage
returns to normal.
If there is any damage to the power cables (crushing or abrasion), the
cables must be repaired or replaced by an authorized person before use
is continued.
Always protect the unit from contact with poisonous gas, vapors or liquids.
When relocating applaince, unplug the power cord and empty all water
from the Appliance’s tanks.
WARNING!
Keep small children away from the Water Generator. Children play-
ing with the HOT dispensing button or hot water drain cap can result in
scalding injuries!

5
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
Do not tilt or tip the Appliance more than 20° from vertical when moving
the Appliance.
Operate the unit only when it is on a solid floor and properly leveled in the
vertical or standing position.
If installed on an uneven surface, a shim or other leveling device(s) must
be used and be properly adjusted to ensure proper and safe operation.
Do not place the unit too close to the wall. Best performance is obtained
when the unit is placed at least 12 inches (30 cm) from the wall.
Do not place any object on top of the Appliance. Good ventilation is re-
quired to ensure optimum performance.
Never install or attempt to use the Water Generator outdoors, even if an
awning or covered space is available. This model of Water Generator is not
designed for or warranted for operation outdoors, regardless of whether
it will be fitted by the owner with a cover.
Avoid exposing the unit to direct sunlight.
If the ambient temperature of the installation location is anticipated to fall
below 32°F (0°C), be certain to completely drain all water and unplug the
Appliance in order to prevent damage to the Appliance caused by freezing.
Similarly, empty and unplug the Water Generator if it will not be used for
5 (FIVE) or more consecutive days.
Always use the correct replacement and maintenance parts specified by
the manufacturer. Failure to do so may void the warranty.
EcoloBlue 30s ONLY CO2 Canisters. Contents under high pressure. Handle with care!
Do not drop the cylinder, throw it, or carry it in a way that it may strike
objects or surfaces while being carried.
CAUTION! Store in a cool location, away from sunlight and all heat sources. Keep
cylinder cool at all times, but do not refrigerate.
Do not store near explosives, gasoline or other fuels, chemicals, or flam-
mable substances or goods.
Do not use any other water supply lines, tubing or hoses other than those
supplied by the manufacturer.

6
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
WARRANTY
Disclaimer of Implied Warranties; Limitation of Remedies
Implied warranties, including, to the extent applicable, warranties of merchantability or fitness for a
particular purpose, are excluded to the extent legally permissible under the laws of the user's jurisdic-
tion. Any implied warranties that may be imposed by law are limited to one year, or the shortest period
allowed by law. Some states and Canadian provinces do not allow limitations or exclusions on the du-
ration of an implied warranty of merchantability or fitness. In such locations, the above limitations or
exclusions may not apply to you.
If this product fails to perform as warranted, customers’ sole and exclusive remedy shall be repair or
replacement, according to the terms of the limited warranty of EcoloBlue, Inc. EcoloBlue, Inc. does not
assume any responsibility or liability for incidental or consequential damages arising or resulting from
the use of the EcoloBlue Life & Energy Atmospheric Water Generator, Model 30 Series. This warranty
gives you specific legal rights; you may also have other rights, which vary from state to state or province
to province.

7
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
EcoloBlue 30 Series AWG Water Cooler
How the Atmospheric Water Generator Works
The Atmospheric Water Generator is a humidity and temperature-driven Appliance. This means the
Appliance’s ability to generate water depends entirely on the level of humidity and atmospheric tem-
perature. To achieve optimum performance, the indicated relative humidity should be at least 50% or
more. In regions with lower humidity levels, the Appliance will produce water at a slower rate and with
less volume than that of a higher humidity environment. In a residential environment, higher levels of
humidity tend to be found in kitchen areas, near bathrooms used for bathing, near open windows (in
warmer weather), or in more spacious rooms.
This unit also performs well in an air-conditioned room or homes. Because air-conditioning reduces
relative humidity, it is recommended to open the window at night to increase the humidity in the room.
Because the Atmospheric Water Generator works by converting humidity in the air to water, this unit
also acts as an effective dehumidifier. To ensure high quality of the drinking water produced, the Atmo-
spheric Water Generator utilizes multiple filtration technologies (see below).
When the air is dry and cold, water generation may become slow and inefficient. It is recommended
that the Appliance be connected to a municipal water supply allowing the Appliance to serve as a water
purifier using its filtration system.
Key features of the Atmospheric Water Generator
Energy Saving Features
To conserve electricity, electronic sensors have been placed in the storage tanks to automatically stop
the heating, cooling and production capacity of the Appliance when they have reached their desired
levels or settings.
Child-Resistant Hot Water Lockout
The hot water lockout is to prevent accidental operation which may result in from scalding/burning
upon touching the water or water nozzle.
Ultraviolet Filter Treatment
The ultraviolet lamps help to sanitize and prevent growth of bacteria and other microorganisms in the
system. The UV sanitization process is automatically controlled by the microprocessor.
Multi-Stage Filtration System
EcoloBlue’s high-quality, great tasting water is the result of our unique multi-stage filtration system.
1. Air Filtration
Prevents micro-particles and dust from entering the Appliance.
2. Carbon Bottom Tea Bag
Removes ammonia, chlorine residues, organic compounds, soil particles, dirt, etc.

8
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
3. Bottom Tank UV Lamp
Impedes contamination and growth of bacteria and other microorganisms in the lower tank.
4. Funnel filter
Removes micro-particles to protect the water pump.
5. Sediment EF1 Filter
Removes organic compounds, free chlorine, heavy metals, etc.
6. Pre-Carbon EF2 Filter
Removes organic compounds, free chlorine, heavy metals, etc.
7. Reverse Osmosis Filter
Removes dangerous bacteria, viruses, mineral salts, heavy metals, organic compounds, etc.
8. Mineral Filter
Adds minerals to water removed by the Reverse Osmosis Filter.
9. Post Carbon EF3 Filter
Removes volatile organic compounds and improves water taste and smell.
10. Top Tank UV Sanitizing
Minimizes bacteria levels in the upper “allotment” tank to the least possible number.
11. Inline UV Sanitizing
Ensures clean and safe water is dispensed from the cool water tank.
12. Molecular Sieve Faucet Filters
The Nozzle is equipped with two molecular sieves (screens) to trap any fine particles that may
be suspended in the water.
Components of the Atmospheric Water Generator
Refer to Figures 1 and 2 for more information.
Novel and Attractive Cabinet Style
The EcoloBlue Atmospheric Water Generator has a smaller and sleeker design compared to other Gen-
erators on the market. The unit is more compact and more versatile.
Microcomputer
The unit is equipped with a microcomputer that helps control the systematic operation of internal parts
and mechanisms. The computer regulates water temperature and water level settings.
Electronic Sensors
Electronic feedback and control sensors are attached to many of the Appliance's components and stor-
age tanks- These sensors ensure that important parts are working properly, that water levels are cor-
rect and serve to warn you in the event of a malfunction, leak or performance irregularity.
Centrifugal Fan
Sturdy, quiet and reliable fan that increases production efficiency and greatly reduces noise during operation.

9
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
Water Leak Detector
In case of any unexpected water leak, the Appliance will automatically stop water production, pumping,
cooling and heating. A warning sound (seven fast beeps) will occur and a "warning" icon on the display
will illuminate.
Condensing Coils
The condenser is designed with a special food-contact grade coating to prevent any direct metal contact
with water and improves water production efficiency.
Electrostatic Air Filters
The electrostatic air filters effectively prevents micro-particles and dust from entering the Appliance,
as well as deterring formation of bacterial and fungal growth introduced to the Appliance by the outside
environment.
Overheat Protector
In the event that the hot water tank overheats during the heating process, the overheat protector will
automatically shut off the heating device.
1 Motherboard
2 Exhaust
3 Air Filter
4 Collection Tray
5 Collection Tank
6 Air Filter
7 Hot Water
Drain
8 RO Water Drain
9 Water Inlet
10 Overflow Cup
1 EF1
2 EF2
3 RO
4 Mineral
5 EF3
Figure 1

10
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
Figure 2

11
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
Display
13. Cold Water Temperature - the indicator displays current
temperature of cold water
14. Info Display Icon - Displays the current relative humidity,
temperature and time.
15. Cold Water Out Icon - Press AND HOLD the button to
dispense the cold water.
16. Water Leak Warning icon - System is detecting a leak when
this icon flashes. Please see Troubleshooting page.
17. defrost Icon - The unit is in the defrosting process when this
icon flashes (frost can occur because of low temperature and or
dry air in some areas).
18. Water recirculation/Reflux Icon - Water is recirculating in
the top tank when this icon flashes.
19. Cooling Water Icon - Cooling function is activated when the
icon is lit. A flashing icon indicates a change in temperature is
occuring.
20. Heating Icon - Heating function is activated when the icon is
lit. A flashing icon indicates a change in temperature is occuring.
21. Booster Pump Icon – The pump is on when this icon spins.
22. Filter Replace Warning – Normally the icon stays lit.
23. Water Generation Icon – The unit is generating water when
this icon in animated (raindrops falling). When the icon is
flashing the water generation is off. When icon stays on (no
flashing), the generation is on but water is not generating.
1. UV1 Warning Icon – This icon will flash when the UV1 light
needs replacement. This icon will light when the UV1 is on.
2. UV2 Warning Icon – This icon will flash when the UV2 light
needs replacement. This icon will light when the UV2 is on.
3. UV3 Warning Icon – This icon will flash when the UV3 light
needs replacement. This icon will light when the UV3 is on.
4. Top Tank Water Level Indicator – The level increases as the
amount in the tank increases. .
5. Hot Water Dispenser Icon – When flashes, the hot is
UNLOCKED. Press and Hold the button to dispense the hot
water.
6. Bottom Tank Water Level Indicator – The level increases as
the amount in the tank increases .
7. Hot Water Temperature – the indicator displays current
temperature of hot water .
8. Power ON/OFF Icon – Press and HOLD to start-up or shut off
the Appliance .
9. Hot Water Lock Icon – Press and HOLD until you hear a beep
to “UNLOCK” the hot water dispense .
10.Mode Selection Icon - Press and HOLD until a beep sounds.
Press mode to scroll through options .
11.Setting Button – In the Mode Menu, use Set to change the
selected option. Also used as a -/decrease button in selected
settings.
12.Setting Button – In the Mode Menu, use Set to change the
selected option. Also used as a +/increase button in selected
settings.

12
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
Press and HOLD the MODE button to enter the OPTION MENU.
After beep, press MODE button to scroll through the OPTION MENU.
Change the OPTION you choose by pressing SET button.
Inactivity will result in OPTION MENU exit.
1. Change the Time.
00-00: Press SET button until hour flashes. To change the HOUR press SET button.
Switch to MINUTE by pressing the MODE button and change the MINUTE by pressing
SET button.
2. Timer - To Set Water Generation Time.
T-ON/OFF: By default the timer is set to off and will continue to generate water. To
schedule water generation press SET button to change setting to T--ON. See 3&4 for
time programming.
NOTE: To initiate Timer Option, Water Generation must be set to OFF. See 5.
3. **-** Displays START TIME for pre-set automatic water generation. Press SET
button until hour flashes. To change the HOUR press SET button. Switch to MINUTE by
pressing the MODE button and change the MINUTE by pressing SET button.
4. **/** Displays END TIME for pre-set automatic water generation. Press SET but-
ton until hour flashes. To change the HOUR press SET button. Switch to MINUTE by
pressing the MODE button and change the MINUTE by pressing SET button.
5. W--ON: water generation function ON. W-OFF: water generation function OFF.
6. H--ON: heating function is ON. H-OFF: heating function is OFF.
7. C--ON: cooling function ON. C-OFF: cooling function OFF.
8. H-075~095: displays the pre-set Celsius temperature of hot water.
Can be changed to Fahrenheit see 11. Adjust the temperature by pressing the SET but-
ton. The temperature is ranges between 75°~95° Celsius; 167°~203° Fahrenheit.
9. C-004~010: displays the pre-set temperature of cold water.
Adjust the temperature by pressing the SET button. The temperature is limited be-
tween 4°~10° Celsius; 39°~50° Fahrenheit.
10. FD***: displays filter use. Press SET button to reset filter counter.
11. C/F-C: Temperature in Celcius. C/F-F: Temperature in Fahrenheit. This option is
located after all of the Temperature options.
12. RESET: Press SET button to reset to factory settings.
(10)
+
(11)
Additional Display Options

13
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
(8)
Press and hold to start up or shut down the Appliance.
(9)
+
(5)
Press and hold HOT button to dispense hot water.
(18)
Press and hold COLD button to dispense the cold water.
Press and hold LOCK button after beep

14
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
SET-UP
Setting up the EcoloBlue Atmospheric Water Generator involves proper Preparation and Location; RO Filter
Installation; Cleaning; and Flushing the System prior to use. Setup usually requires approximately 2 hours to
complete. The wrench, tubing coil, and pipe tape supplied with the Generator are for optional connection to a
municipal water supply.
Preparation and Location
CAUTION!
Do not tilt the unit more than 20°; if it is tipped greater than 20°, unit must stand undis-
turbed for 24 hours BEFORE it is operated.
Move unit with a wheeled hand cart where possible. If manual lifting is required, use two
people.
Place the unit on solid and level flooring and located it with adequate air circulation on
all sides.
The unit should be placed no less than 12 inches (30cm) from the wall.
Do NOT connect the unit to the power source within the first half hour after set-up. Leave
the Appliance in a standing position to make sure all refrigerant drains to the compressor.
Immediately connecting the Appliance to its power source after un-packing may damage
the compressor and void its warranty.
The power cord plug must be inserted into an electrical outlet rated to deliver no less than
10 Amperes continuous. Check the panel box breaker rating for the outlet serving the
unit. Consult a licensed electrician if you are not certain.
1 Carefully unpack the EcoloBlue Appliance from the packaging. Note that there are
important parts in the bottom foam packaging under the Appliance.
2 Confirm that the parts provided in the package constitute a complete set by comparing
them with the images shown in Figures 1 and 2. If any parts are missing contact
EcoloBlue or your local distributor.
3 Place the Appliance in the desired location noting the Cautions above.
4 Verify that the brake levers on the front wheels have been pushed down and locked
after the Appliance is in its desired location.
5 Allow the Appliance to stand undisturbed for no less than 30 minutes after relocation if
not tipped (if tipped let stand 24 hours).

15
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
INSTALLATION CHECKLIST
Unpack the unit from its packaging
Confirm all the parts are there (Refer to Figures 1 and 2)
Place the unit in desired location
Lock brake levers
Install Reverse Osmosis Filter
Clean the bottom storage tank
Flush the system
Connect to Municipal (City) Water (optional)

16
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
CAUTION!
Always wash your hands thoroughly and wear latex or other hygienic gloves when
performing maintenance on the Appliance to minimize the risk of contamination of internal
parts.
Reverse Osmosis Filter Installation
1 Install the Reverse Osmosis Filter (found in the foam packaging) as described below:
2 Open the bottom front panel of the Appliance by carefully opening the front panel from
the left. (Figure 3).
3 Locate the empty filter space. (Figure 4).
4 Gently pull filter cap towards you. (Figure 5).
5 Remove the RO filter from the packaging.
6 Install the RO Filter in the proper orientation. (Figure 6-8).
7 Close the front panel
Figure 3 Figure 4
Remove RO filter from packaging. Push RO filter up into cap.
Open the bottom front panel. Gently pull filter cap towards you.
Figure 5 Figure 6

17
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
Cleaning
Clean the bottom storage tank. See detailed instructions in cleaning the bottom tank on page 29.
Flushing the System
1 Fill the bottom tank until full with municipal water. Plug in the Appliance. Appliance
should power on, if not, turn the power ON by pressing the POWER button on the front
display of the Appliance.
2 The pump will switch on and pump the water until the bottom tank depletes to a level 2.
3 MAKE SURE TO TURN OFF THE APPLIANCE EVERYTIME YOU FILL THE BOTTOM TANK
OR IT MIGHT RESULT IN A LEAK WARNING. Overfilling the bottom tank also
might result in a leak triggering the leak detector.
4 Turn the power OFF by pressing and holding POWER button.
5 Drain water from the rear HOT Water Drain outlet. The HOT Water drain has a screw
cap and a rubber plug, please remove both. When draining complete, replace plug and
cap.
6 Turn the power ON and the Appliance will now begin generating water. Maximum
generation may take up to 72 hours.
. Rotate RO Filter counter-clockwise. Lower Reverse Osmosis into place.
Figure 7 Figure 8

18
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
Optional Connection to Municipal (City) Water
The Atmospheric Water Generator will purify municipal (city) water if it is connected to a city water
source. Connect the city water to the Connector as shown in Figure 11, 12 and described below.
Some parts are optional. Please contact your local retailer for purchase. Use the enclosed munici-
pal water kit to connect with city water input.
1 Shut off the city water supply.
2 Remove the included Water Tap adaptor. If no threaded tap source is available contact
your local plumber for assistance. Clean the threaded end to remove any debris.
Thread the Tee Connector to the city water supply. Place the enclosed pipe tape on the
threads before making the connection. Secure with the enclosed wrench.
3 Connect the tap to the Tee Connector and water supply line. Place pipe tape on the
threads before making the connection. If no tap is needed, use the enclosed threaded
plug and pipe tape to plug the supply at the end of the Tee Connector. Secure with the
enclosed wrench.
4 Place thread tape on the threads of the Appliance’s Input Valve and then connect the
valve to threaded Tee Connector. Secure with the enclosed wrench.
5 Cut the water tube to the length needed for your application.
6 Remove the nut from the Input Valve.
7 Slide the nut over the water tube so that the threads face the end of the tube.
8 Place pipe tape on the threads of the Input Valve.
9 Slide the water tube over the ridge on the end of the input valve and secure the Input
Valve nut using the enclosed wrench.(Figure 11)
10 Connect the water tube to the optional filter(s) as needed.
11 At the cut end of the tube, slide the plastic connector over the end of the water tube with
the threads facing the end of the tube.
12 Insert the plastic sleeve into the end of the water tube.
13 Connect the water tube to the Appliance connection labeled WATER INLET. There is a
rubber plug inside the inlet that must be removed before connecting the tube to the
Appliance. Turn the power OFF (Figure 12).
14 Drain out all remaining water from the rear HOT Water Drain outlet.
15 Secure water tube hand tight.
16 Turn ON the water supply and check for leaks. Tighten fittings as necessary.

19
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
Figure 9
Figure 11 Figure 12
Figure 10
Plastic Sleeve
Plastic Nut
Tee Connector
Water Tube
Nut
Input Valve
Plug
Table of contents
Popular Water System manuals by other brands

Grunbeck
Grunbeck GENO-VARIO mini Operation manual

Ofs
Ofs Softcontrol Data/F manual

Sterling
Sterling HE Series Installation instructions & owner's manual

Watts Premier
Watts Premier 5 SV DELUXE Installation, operation and maintenance manual

Kenmore
Kenmore ULTRAFILTER 300 625.384720 owner's manual

Puro
Puro 35T Installation, operation & service manual

Katadyn
Katadyn Steripen Ultra user guide

Horizon Reverse Osmosis
Horizon Reverse Osmosis Seafari Quest Compact 200 owner's manual

Everpure
Everpure Scalekleen EV9796-20 Specification sheet

Beretta
Beretta IDRA DS 200 N Installation and operation manual

MECHLINE
MECHLINE AQUAJET AJPR50-2 INSTALLATION & CARE INSTRUCTIONS

YSI
YSI 600DW-B user manual